Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Europace ; 24(5): 796-806, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35079787

RESUMO

AIMS: To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120-150 ms). METHODS AND RESULTS: Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups. CONCLUSION: Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group. CLINICAL TRIAL REGISTRATION NUMBER: Clinicaltrials.gov: NCT02529410.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 32(3): 802-812, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484216

RESUMO

BACKGROUND: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades. METHODS: Patients undergoing LV lead upgrade underwent ECG-gated cardiac CT dyssynchrony and LV scar assessment. Target American Heart Association segment selection was determined using latest non-scarred mechanically activating segments overlaid onto real-time fluoroscopy with image co-registration to guide optimal LV lead implantation. Hemodynamic validation was performed using a pressure wire in the LV cavity (dP/dtmax) ). RESULTS: 18 patients (male 94%, 55.6% ischemic cardiomyopathy) with RV pacing burden 60.0 ± 43.7% and mean QRS duration 154 ± 30 ms underwent cardiac CT. 10/10 ischemic patients had CT evidence of scar and these segments were excluded as targets. Seventeen out of 18 (94%) patients underwent successful LV lead implantation with delivery to the CT target segment in 15 out of 18 (83%) of patients. Acute hemodynamic response (dP/dtmax ≥ 10%) was superior with LV stimulation in CT target versus nontarget segments (83.3% vs. 25.0%; p = .012). Reverse remodeling at 6 months (LV end-systolic volume improvement ≥15%) occurred in 60% of subjects (4/8 [50.0%] ischemic cardiomyopathy vs. 5/7 [71.4%] nonischemic cardiomyopathy, p = .608). CONCLUSION: Intraprocedural integration of cardiac CT to guide optimal LV lead placement is feasible with superior hemodynamics when pacing in CT target segments and favorable volumetric response rates, despite a high proportion of patients with ischemic cardiomyopathy. Multicentre, randomized controlled studies are needed to evaluate whether intraprocedural integration of cardiac CT is superior to standard care.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
4.
J Electrocardiol ; 68: 117-123, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34416669

RESUMO

AIMS: Electrocardiographic imaging (ECGi) and the ECG belt are body surface potential mapping systems which can assess electrical dyssynchrony in patients undergoing cardiac resynchronization therapy (CRT). ECGi-derived dyssynchrony metrics are calculated from reconstructed epicardial potentials based on body surface potentials combined with a thoracic CT scan, while the ECG belt relies on body surface potentials alone. The relationship between dyssynchrony metrics from these two systems is unknown. In this study we aim to compare intra-ventricular and inter-ventricular dyssynchrony metrics between ECGi and the ECG belt. METHODS: Seventeen patients underwent ECGi after CRT. A subsample of 40 body surface potentials was used to simulate the ECG belt. ECGi dyssynchrony metrics, calculated from reconstructed epicardial potentials, and ECG belt dyssynchrony metrics, calculated from the sampled body surface potentials were compared. RESULTS: There was a strong positive correlation between ECGi left ventricular activation time (LVAT) and ECG belt left thorax activation time (LTAT) (R = 0.88 ; P < 0.001) and between ECGi standard deviation of activation times (SDAT) and ECG belt-SDAT (R = 0.76; P < 0.001) during intrinsic rhythm. The correlation for both pairs was also strong during biventricular pacing. Ventricular electrical uncoupling, a well validated ECGi inter-ventricular dyssynchrony metric, correlated strongly with ECG belt-SDAT during intrinsic rhythm (R = 0.76; P < 0.001) but not biventricular pacing (R = 0.29; P = 0.26). Cranial or caudal displacement of the simulated ECG belt did not affect LTAT or SDAT. CONCLUSION: ECGi- and ECG belt-derived intra-ventricular and inter-ventricular dyssynchrony metrics were strongly correlated. The ECG belt may offer comparable dyssynchrony assessment to ECGi, with associated practical and cost advantages.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos
5.
Pacing Clin Electrophysiol ; 43(7): 737-745, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32469085

RESUMO

BACKGROUND: Antitachycardia pacing (ATP), which may avoid unnecessary implantable cardioverter-defibrillator (ICD) shocks, does not always terminate ventricular arrhythmias (VAs). Mean entropy calculated using cardiac magnetic resonance texture analysis (CMR-TA) has been shown to predict appropriate ICD therapy. We examined whether scar heterogeneity, quantified by mean entropy, is associated with ATP failure and explore potential mechanisms using computer modeling. METHODS: A subanalysis of 114 patients undergoing CMR-TA where the primary endpoint was delivery of appropriate ICD therapy (ATP or shock therapy) was performed. Patients receiving appropriate ICD therapy (n = 33) were dichotomized into "successful ATP" versus "shock therapy" groups. In silico computer modeling was used to explore underlying mechanisms. RESULTS: A total of 16 of 33 (48.5%) patients had successful ATP to terminate VA, and 17 of 33 (51.5%) patients required shock therapy. Mean entropy was significantly higher in the shock versus successful ATP group (6.1 ± 0.5 vs 5.5 ± 0.7, P = .037). Analysis of patients receiving ATP (n = 22) showed significantly higher mean entropy in the six of 22 patients that failed ATP (followed by rescue ICD shock) compared to 16 of 22 that had successful ATP (6.3 ± 0.7 vs 5.5 ± 0.7, P = .048). Computer modeling suggested inability of the paced wavefront in ATP to successfully propagate from the electrode site through patchy fibrosis as a possible mechanism of failed ATP. CONCLUSIONS: Our findings suggest lower scar heterogeneity (mean entropy) is associated with successful ATP, whereas higher scar heterogeneity is associated with more aggressive VAs unresponsive to ATP requiring shock therapy that may be due to inability of the paced wavefront to propagate through scar and terminate the VA circuit.


Assuntos
Cicatriz/fisiopatologia , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/terapia , Simulação por Computador , Desfibriladores Implantáveis , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
6.
Pacing Clin Electrophysiol ; 43(9): 966-973, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32330307

RESUMO

BACKGROUND: Endocardial pacing may be beneficial in patients who fail to improve following conventional epicardial cardiac resynchronization therapy (CRT). The potential to pace anywhere inside the left ventricle thus avoiding myocardial scar and targeting the latest activating segments may be particularly important. The WiSE-CRT system (EBR systems, Sunnyvale, CA) reliably produces wireless, endocardial left ventricular (LV) pacing. The purpose of this analysis was to determine whether this system improved symptoms or led to LV remodeling in patients who were nonresponders to conventional CRT. METHOD: An international, multicenter registry of patients who were nonresponders to conventional CRT and underwent implantation with the WiSE-CRT system was collected. RESULTS: Twenty-two patients were included; 20 patients underwent successful implantation with confirmation of endocardial biventricular pacing and in 2 patients, there was a failure of electrode capture. Eighteen patients proceeded to 6-month follow-up; endocardial pacing resulted in a significant reduction in QRS duration compared with intrinsic QRS duration (26.6 ± 24.4 ms; P = .002) and improvement in left ventricular ejection fraction (LVEF) (4.7 ± 7.9%; P = .021). The mean reduction in left ventricular end-diastolic volume was 8.3 ± 42.3 cm3 (P = .458) and left ventricular end-systolic volume (LVESV) was 13.1 ± 44.3 cm3 (P = .271), which were statistically nonsignificant. Overall, 55.6% of patients had improvement in their clinical composite score and 66.7% had a reduction in LVESV ≥15% and/or absolute improvement in LVEF ≥5%. CONCLUSION: Nonresponders to conventional CRT have few remaining treatment options. We have shown in this high-risk patient group that the WiSE-CRT system results in improvement in their clinical composite scores and leads to LV remodeling.


Assuntos
Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Endocárdio/fisiopatologia , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Falha de Tratamento , Remodelação Ventricular
7.
J Electrocardiol ; 58: 96-102, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31805438

RESUMO

INTRODUCTION: Cardiac resynchronisation therapy (CRT) corrects electrical dyssynchrony. However, the temporal changes in the electrical timing according to substrate are unclear. We used electrocardiographic imaging (ECGi) for serial non-invasive assessment of the underlying electrical substrate and its response to resynchronisation. MATERIAL AND METHODS: ECGi activation maps were constructed 1 day and 6 months post CRT implant. ECGi maps were analysed offline to determine the total ventricular activation time (TVaT) and the time for the bulk of ventricular activation (10th to 90th percentile activation; VaT10-90 Index). Statistical analysis was performed using repeated measures ANOVA with post-hoc pairwise comparisons using paired t-tests. The % relative change within each time point was also calculated and compared between the two time points. RESULTS: Eleven CRT patients were studied. Both total and bulk ventricular activation significantly decreased with CRT turned ON at day 1. Intrinsic (CRT OFF) TVaT and VaT10-90 Index at day 1 were 143 ± 23 and 84 ± 20 ms, respectively, and they significantly decreased post CRT to 115 ± 26 ms (P < 0.001) and 49 ± 17 ms (P < 0.05), respectively. The relative change at day 1 was also statistically significant for TVaT (19 ± 12%, P < 0.001) and VaT10-90 Index (39 ± 25%, P < 0.001). After 6 months, the relative decrease in TVaT with CRT ON remained stable (19% vs. 18% at day 1 and 6 months, respectively) whereas reduction the in VaT10-90 Index was decreased 39% vs. 26% at day 1 and 6 months, respectively. In non-ischaemic patients both total and bulk activation times reduced following CRT. Volumetric responders exhibited an electrical remodelling for bulk activation not apparent in Non-responders, after 6 months of CRT ON. CONCLUSIONS: Intrinsic bulk myocardium activation becomes more rapid and synchronous with CRT. The bulk activation time is more susceptible to improvement by CRT in ischaemic patients and volumetric responders. These observations are consistent with CRT causing reverse electrophysiological remodelling in the bulk myocardium, but not in late-activating ischaemic or fibrotic regions.


Assuntos
Remodelamento Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Eletrocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Resultado do Tratamento , Remodelação Ventricular
8.
Biophys J ; 117(12): 2375-2381, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31547974

RESUMO

Cardiac resynchronization therapy (CRT) is an important treatment for heart failure. Low female enrollment in clinical trials means that current CRT guidelines may be biased toward males. However, females have higher response rates at lower QRS duration (QRSd) thresholds. Sex differences in the left ventricle (LV) size could provide an explanation for the improved female response at lower QRSd. We aimed to test if sex differences in CRT response at lower QRSd thresholds are explained by differences in LV size and hence predict sex-specific guidelines for CRT. We investigated the effect that LV size sex difference has on QRSd between male and females in 1093 healthy individuals and 50 CRT patients using electrophysiological computer models of the heart. Simulations on the healthy mean shape models show that LV size sex difference can account for 50-100% of the sex difference in baseline QRSd in healthy individuals. In the CRT patient cohort, model simulations predicted female-specific guidelines for CRT, which were 9-13 ms lower than current guidelines. Sex differences in the LV size are able to account for a significant proportion of the sex difference in QRSd and provide a mechanistic explanation for the sex difference in CRT response. Simulations accounting for the smaller LV size in female CRT patients predict 9-13 ms lower QRSd thresholds for female CRT guidelines.


Assuntos
Terapia de Ressincronização Cardíaca , Simulação por Computador , Guias de Prática Clínica como Assunto , Caracteres Sexuais , Idoso , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Tamanho do Órgão
9.
Heart Fail Rev ; 24(1): 41-54, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30143910

RESUMO

Heart failure is a complex clinical syndrome associated with a significant morbidity and mortality burden. Reductions in left ventricular (LV) function trigger adaptive mechanisms, leading to structural changes within the LV and the potential development of dyssynchronous ventricular activation. This is the substrate targeted during cardiac resynchronisation therapy (CRT); however, around 30-50% of patients do not experience benefit from this treatment. Non-response occurs as a result of pre-implant, peri-implant and post implant factors but the technical constraints of traditional, transvenous epicardial CRT mean they can be challenging to overcome. In an effort to improve response, novel alternative methods of CRT delivery have been developed and of these endocardial pacing, where the LV is stimulated from inside the LV cavity, appears the most promising.


Assuntos
Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Endocárdio/metabolismo , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pericárdio/metabolismo , Fatores Sexuais , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
10.
Europace ; 21(6): 928-936, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590509

RESUMO

AIMS: Transvenous lead extraction (TLE) may be necessary due to system infection/erosion or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may be at greater risk due to increased comorbidities. We examined whether patients with CRT systems undergoing TLE had more comorbidities and higher 30-day mortality than those with non-CRT devices. METHODS AND RESULTS: All TLEs between October 2000 and December 2016 were prospectively collected. During this period 925 TLEs occurred (CRT group 231, non-CRT group 694). Cardiac resynchronization therapy patients were older (68.1 ± 10.8 years vs. 64.3 ± 16.1 years, P = 0.024); more likely male (85.7% vs. 69%, P < 0.001); had lower mean left ventricular ejection fraction (34.1 ± 12.7% vs. 48.3 ± 12.9%, P < 0.001); had higher prevalence of renal impairment (33.8% vs. 13.7%, P < 0.001) and were more likely to have ≥2 comorbidities (84% vs. 40.1%, P < 0.001). Mean lead dwell time was lower in the CRT group (5.6 ± 5.5 years vs. 7.6 ± 7.1 years, P = 0.002). There was no significant difference in all-cause 30-day mortality rates between CRT (3.0%, n = 7) and non-CRT patients (2.0%, n = 14) (P = 0.443). The majority of deaths in both groups were due to sepsis. Univariate and multivariate analysis showed age, renal impairment and sepsis were associated with increased risk of 30-day mortality. Transvenous lead extraction of a CRT system did not predict 30-day mortality. CONCLUSION: Transvenous lead extraction in CRT patients was not associated with increased 30-day mortality when compared with non-CRT patients. Age, renal impairment and sepsis were independent predictors of 30-day mortality. Sepsis was the main cause of 30-day mortality.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo , Mortalidade/tendências , Idoso , Causas de Morte , Comorbidade , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
11.
Pacing Clin Electrophysiol ; 42(10): 1355-1364, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31433064

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be performed by superior approach using the original implant vein or via a femoral approach; however, limited comparative data exists. We compare outcomes between femoral versus nonfemoral TLE approaches and determine predictors of bailout transfemoral lead extraction in patients undergoing initial TLE via the original implant vein by a superior approach. METHODS: All consecutive TLEs between October 2000 and March 2018 were prospectively collected (n = 1052). Patients were dichotomized into femoral (n = 118) and nonfemoral (n = 934) groups. RESULTS: Demographics were balanced between femoral vs nonfemoral groups. Patients in the femoral group had significantly higher mean lead dwell times (11.6 ± 9.7 vs 6.6 ± 6.6 years, P < .001), mean number of leads extracted (2.7 ± 1.3 vs 2.0 ± 1.0, P < .001), 30-day procedure related major complications (including deaths) (8.5% vs 1.1%, P < .001) and emergency thoracotomy rates (4.2% vs 0.7%, P = .007). All-cause 30-day mortality rates were similar between groups (3.4% vs 2.0%, P = .315). Prolonged lead dwell time and increased number of leads extracted were predictive of a bailout transfemoral approach at multivariable analysis. CONCLUSION: Femoral approach TLE is associated with increased risk of 30-day procedure related major complications but not 30-day all-cause mortality. Prolonged lead dwell time and increased number of leads extracted are independent predictors for bailout transfemoral lead extraction. Such patients should be considered high risk of major complications and performed by high-volume lead extraction centers with experience in multiple approaches and techniques including experience with transfemoral lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Idoso , Desenho de Equipamento , Falha de Equipamento , Veia Femoral , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo
12.
Pacing Clin Electrophysiol ; 42(1): 73-84, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30411817

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be necessary due to infective and noninfective indications. We aim to identify predictors of 30-day mortality and risk factors between infective versus noninfective groups and systemic versus local infection subgroups. METHODS: A total of 925 TLEs between October 2000 and December 2016 were prospectively collected and dichotomized (infective group n = 505 vs noninfective group n = 420 and systemic infection n = 164 vs local infection n = 341). RESULTS: All-cause major complication including deaths was significantly higher (5.1%, n = 26 vs 1.2%, n = 5, P = 0.001) as well as 30-day mortality (4.0%, n = 20 vs 0.2%, n = 1, P < 0.001) in the infective group compared to the noninfective group. Both subgroups (systemic vs local infection) were balanced for demographics. All-cause major complication including deaths was significantly higher (9.1%, n = 15 vs 3.2%, n = 11, P = 0.008) as well as all-cause 30-day mortality (7.9%, n  = 13 vs 2.1%, n = 7, P = 0.003) in the systemic infection subgroup compared to the local infection subgroup. CONCLUSION: Patients undergoing TLE for infective indications are at greater risk of 30-day all-cause mortality compared to noninfective patients. Patients undergoing TLE for systemic infective indications are at greater risk of 30-day all-cause mortality compared to patients with local infection. Renal impairment, systemic infection, and elevated preprocedure C-reactive protein are independent predictors of 30-day all-cause mortality in patients undergoing TLE for an infective indication.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/mortalidade , Idoso , Causas de Morte , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco
13.
J Cardiovasc Electrophysiol ; 29(12): 1675-1681, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30106206

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is typically delivered via quadripolar leads that allow stimulation using either true bipolar pacing, where stimulation occurs between two electrodes (BP) on the quadripolar lead, or extended bipole (EBP) left ventricular (LV) pacing, with the quadripolar electrodes and right ventricular coil acting as the cathode and anode, respectively. True bipolar pacing is associated with reductions in mortality and it has been postulated that these differences are the result of enhanced electrical activation. MATERIALS AND METHODS: Patients undergoing a CRT underwent an electrocardiographic imaging study where electrical activation data were recorded while different LV pacing vectors were temporarily programmed. RESULTS: There were no differences in the total electrical activation times or dispersion of electrical activation between biventricular pacing with bipolar or corresponding EBP LV vector configurations (left ventricular total activation time [LVtat] BP 74.70 ± 18.07 vs EBP 72.4 ± 22.64; P = 0.45). When dichotomized according to etiology, no difference was observed in the activation time with either BP or EBP pacing (LVtat BP ischemic cardiomyopathy 72.2 ± 17.4 vs BP dilated cardiomyopathy 79.9 ± 18.9; P = 0.38). CONCLUSIONS: Bipolar pacing alters the mechanical activation sequence of the LV and is associated with reductions in all-cause mortality. It has been postulated these benefits derive from improvements in electromechanical activation of the LV. Our study would suggest that true bipolar pacing does not necessarily result in more favorable activation of the LV or improved electrical resynchronization and other mechanisms should be explored.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Cardiopatias/fisiopatologia , Cardiopatias/cirurgia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 20(11): 1733-1740, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29452360

RESUMO

Cardiac implantable electronic devices implantation rates have increased over the past decade due to broader indications and an ageing population. Similarly, device and lead complications have also risen. The management of pacemaker/defibrillator leads that are no longer required (redundant) or malfunctioning, can be contentious. There is a need to balance the risk of transvenous lead extraction (TLE) against those of lead abandonment. The recently published European Lead Extraction ConTRolled Registry (ELECTRa) study provides contemporary outcomes for TLE across Europe with important implications for the management of redundant and/or malfunctioning leads. This review article discusses the potential complications for each interventional approach when managing redundant or malfunctioning pacemaker leads.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Falha de Equipamento , Marca-Passo Artificial/efeitos adversos , Arritmias Cardíacas/terapia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Europa (Continente) , Humanos , Resultado do Tratamento
15.
Europace ; 20(12): 1989-1996, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29688340

RESUMO

Aims: The optimal site for biventricular endocardial (BIVENDO) pacing remains undefined. Acute haemodynamic response (AHR) is reproducible marker of left ventricular (LV) contractility, best expressed as the change in the maximum rate of LV pressure (LV-dp/dtmax), from a baseline state. We examined the relationship between factors known to impact LV contractility, whilst delivering BIVENDO pacing at a variety of LV endocardial (LVENDO) locations. Methods and results: We compiled a registry of acute LVENDO pacing studies from five international centres: Johns Hopkins-USA, Bordeaux-France, Eindhoven-The Netherlands, Oxford-United Kingdom, and Guys and St Thomas' NHS Foundation Trust, London-UK. In all, 104 patients incorporating 687 endocardial and 93 epicardial pacing locations were studied. Mean age was 66 ± 11 years, mean left ventricular ejection fraction 24.6 ± 7.7% and mean QRS duration of 163 ± 30 ms. In all, 50% were ischaemic [ischaemic cardiomyopathy (ICM)]. Scarred segments were associated with worse haemodynamics (dp/dtmax; 890 mmHg/s vs. 982 mmHg/s, P < 0.01). Delivering BiVENDO pacing in areas of electrical latency was associated with greater improvements in AHR (P < 0.01). Stimulating late activating tissue (LVLED >50%) achieved greater increases in AHR than non-late activating tissue (LVLED < 50%) (8.6 ± 9.6% vs. 16.1 ± 16.2%, P = 0.002). However, the LVENDO pacing location with the latest Q-LV, was associated with the optimal AHR in just 62% of cases. Conclusions: Identifying viable LVENDO tissue which displays late electrical activation is crucial to identifying the optimal BiVENDO pacing site. Stimulating late activating tissue (LVLED >50%) yields greater improvements in AHR however, the optimal location is frequently not the site of latest activation.


Assuntos
Potenciais de Ação , Terapia de Ressincronização Cardíaca/métodos , Endocárdio/fisiopatologia , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Contração Miocárdica , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Europa (Continente) , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Ventricular
16.
Pacing Clin Electrophysiol ; 41(2): 155-160, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29314081

RESUMO

BACKGROUND: A proportion of patients who undergo an initial lead extraction procedure will require a second, repeat extraction. Data regarding this clinical entity are scarce and neither the predisposing risk factors for, nor outcomes from, these procedures have been described previously. We sought to determine the incidence, risk factors, and outcomes of repeat lead extraction. METHODS: A database of extraction procedures from 2001 to 2015 was analyzed. Repeat extraction procedures were identified and the indication for extraction was dichotomized into infection and lead-related problems. Univariate and multivariate analyses were performed to identify predictors of repeat extraction. RESULTS: 807 extraction procedures were identified in 755 patients of whom 6% required a repeat extraction. At multivariate analysis, only suffering a major complication at the initial extraction procedure (odds ratio [OR] 21.5, 95% confidence interval [CI] 2.69-171.92; P < 0.01), complexity of device (cardiac resynchronization devices/implantable cardioverter defibrillators) (OR 2.58, 95% CI 1.2-5.2; P = 0.01), and age (OR 1.02 per year, 95% CI 1.0-1.4; P  =  0.03) were significant predictors of repeat extraction. When repeat extraction was required for infection there was a significant increase in mortality compared with those who did not require a second procedure (36% vs 23%; P  =  0.02). CONCLUSIONS: Repeat lead extraction is required in 6% of cases. Complexity of device, age at extraction, and a major complication at the first extraction were predictors of repeat extraction. Mortality is significantly increased where the repeat procedure is for infection. Clinicians should alert patients to the potential need for further extraction and the increased risks of repeat procedures when indicated for infection.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Idoso , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
J Electrocardiol ; 51(4): 714-719, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29997019

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is now generally delivered via quadripolar leads. Assessment of the effect of different vector programs from quadripolar leads on ventricular activation can be now done using non-invasive electrocardiographic mapping (ECM). MATERIAL AND METHODS: In nineteen patients with quadripolar LV leads, activation maps were constructed. The total ventricular activation time (TVaT) and the time for the bulk of ventricular activation (VaT10-90) were calculated. RESULTS: CRT delivered via a quadripolar lead significantly reduced TVaT and VaT10-90 by a mean of 16 ms and 31 ms, respectively, compared to baseline. There was a marked reduction in ventricular activation between the most and least synchronous vectors: 28% difference in baseline TVaT and 37% difference in VaT10-90. CONCLUSION: Changes in the configuration of an LV quadripolar lead significantly affected ventricular activation timings in both ischaemic and non-ischaemic subjects. This suggests that programming of the optimal pacing vector may need to be individually tailored.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Curr Heart Fail Rep ; 15(2): 61-69, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29435789

RESUMO

PURPOSE OF REVIEW: We review the trials that have demonstrated potentially harmful effects from right ventricular (RV) apical pacing as well as reviewing the evidence of alternative RV pacing sites and cardiac resynchronization therapy (CRT) for patients who have heart failure and atrioventricular (AV) block. RECENT FINDINGS: The role of CRT in patients with AV block and impaired left ventricular function remains an important consideration. The BLOCK HF trial demonstrated better outcomes with CRT pacing over RV pacing in patients with left ventricular systolic dysfunction (LVSD) and AV block who were expected to have a high RV pacing burden, but failed to demonstrate a mortality benefit. CRT seems to have a beneficial effect on left ventricular reverse remodeling, systolic function, and clinical outcomes in patients with New York Heart Association (NYHA) functional class I-III heart failure, moderate to severe LVSD, and AV block compared to RV pacing. However, it is less clear whether there is a similar benefit from CRT in patients with a high percentage of RV pacing who have normal or mild LVSD in the treatment of AV block.


Assuntos
Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Resultado do Tratamento
19.
Curr Heart Fail Rep ; 15(1): 1-9, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29404975

RESUMO

PURPOSE OF REVIEW: To give an update on the emerging role of cardiac magnetic resonance imaging in the evaluation of patients with heart failure with preserved ejection fraction (HFpEF). This is important as the diagnosis of HFpEF remains challenging and cardiac imaging is pivotal in establishing the function of the heart and whether there is evidence of structural heart disease or diastolic dysfunction. Echocardiography is widely available, although the gold standard in quantifying heart function is cardiac magnetic resonance (CMR) imaging. RECENT FINDINGS: This review includes the recently updated 2016 European Society of Cardiology guidelines on diagnosing HFpEF that define the central role of imaging in identifying patients with HFpEF. Moreover, it includes the pathophysiology in HFpEF, how CMR works, and details current CMR techniques used to assess structural heart disease and diastolic function. Furthermore, it highlights promising research techniques that over the next few years may become more used in identifying these patients. CMR has an emerging role in establishing the diagnosis of HFpEF by measuring the left ventricular ejection fraction (LVEF) and evidence of structural heart disease and diastolic dysfunction.


Assuntos
Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos
20.
J Cardiovasc Electrophysiol ; 28(7): 785-795, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28485545

RESUMO

INTRODUCTION: The role of implantable cardioverter defibrillators (ICDs) in nonischemic cardiomyopathy is unclear and better risk-stratification is required. We sought to determine if T1 mapping predicts appropriate defibrillator therapy in patients with nonischemic cardiomyopathy. We studied a mixed cohort of ischemic and nonischemic patients to determine whether different cardiac magnetic resonance (CMR) applications (T1 mapping, late gadolinium enhancement, and Grayzone) were selectively predictive of therapies for the different arrhythmic substrates. METHODS AND RESULTS: We undertook a prospective longitudinal study of consecutive patients receiving defibrillators in a tertiary cardiac center. Participants underwent CMR myocardial tissue characterization using T1 mapping and conventional CMR scar assessment before device implantation. QRS duration and fragmentation on the surface electrocardiogram were also assessed. The primary endpoint was appropriate defibrillator therapy. One-hundred thirty patients were followed up for a median of 31 months (IQR ± 9 months). In nonischemic patients, T1_native was the sole predictor of the primary endpoint (hazard ratio [HR] 1.12 per 10 millisecond increment in value [95% confidence interval [CI] 1.04-1.21; P ≤ 0.01]). In ischemic patients, Grayzone_2SD-3SD was the strongest predictor of appropriate therapy (HR 1.34 per 1% left ventricular increment in value [95% CI 1.03-1.76; P = 0.03]). QRS fragmentation correlated well with myocardial scar core (receiver operating characteristic area under the curve [ROC AUC] 0.64; P = 0.02) but poorly with T1_native (ROC AUC 0.4) and did not predict appropriate therapy. CONCLUSIONS: In the medium-long term, T1_native mapping was the only independent predictor of therapy in nonischemic patients, whereas Grayzone was a better predictor in ischemic patients. These findings suggest a potential role for T1_native mapping in the selection of patients for ICDs in a nonischemic population.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Desfibriladores Implantáveis , Eletrocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos , Fibrilação Ventricular/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/fisiopatologia , Desfibriladores Implantáveis/tendências , Eletrocardiografia/tendências , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Imagem Cinética por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa