Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Microsc ; 264(2): 159-174, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27238911

RESUMO

A new method based on nonlinear least squares regression (NLLSR) is formulated to estimate signal-to-noise ratio (SNR) of scanning electron microscope (SEM) images. The estimation of SNR value based on NLLSR method is compared with the three existing methods of nearest neighbourhood, first-order interpolation and the combination of both nearest neighbourhood and first-order interpolation. Samples of SEM images with different textures, contrasts and edges were used to test the performance of NLLSR method in estimating the SNR values of the SEM images. It is shown that the NLLSR method is able to produce better estimation accuracy as compared to the other three existing methods. According to the SNR results obtained from the experiment, the NLLSR method is able to produce approximately less than 1% of SNR error difference as compared to the other three existing methods.

2.
J Microsc ; 263(1): 64-77, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26871742

RESUMO

A new technique to quantify signal-to-noise ratio (SNR) value of the scanning electron microscope (SEM) images is proposed. This technique is known as autocorrelation Levinson-Durbin recursion (ACLDR) model. To test the performance of this technique, the SEM image is corrupted with noise. The autocorrelation function of the original image and the noisy image are formed. The signal spectrum based on the autocorrelation function of image is formed. ACLDR is then used as an SNR estimator to quantify the signal spectrum of noisy image. The SNR values of the original image and the quantified image are calculated. The ACLDR is then compared with the three existing techniques, which are nearest neighbourhood, first-order linear interpolation and nearest neighbourhood combined with first-order linear interpolation. It is shown that ACLDR model is able to achieve higher accuracy in SNR estimation.

3.
J Microsc ; 260(3): 352-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26292081

RESUMO

A new technique based on nearest neighbourhood method is proposed. In this paper, considering the noise as Gaussian additive white noise, new technique single-image-based estimator is proposed. The performance of this new technique such as adaptive slope nearest neighbourhood is compared with three of the existing method which are original nearest neighbourhood (simple method), first-order interpolation method and shape-preserving piecewise cubic hermite autoregressive moving average. In a few cases involving images with different brightness and edges, this adaptive slope nearest neighbourhood is found to deliver an optimum solution for signal-to-noise ratio estimation problems. For different values of noise variance, the adaptive slope nearest neighbourhood has highest accuracy and less percentage estimation error. Being more robust with white noise, the new proposed technique estimator has efficiency that is significantly greater than those of the three methods.

4.
J Microsc ; 258(2): 140-50, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25676007

RESUMO

A new technique based on cubic spline interpolation with Savitzky-Golay smoothing using weighted least squares error filter is enhanced for scanning electron microscope (SEM) images. A diversity of sample images is captured and the performance is found to be better when compared with the moving average and the standard median filters, with respect to eliminating noise. This technique can be implemented efficiently on real-time SEM images, with all mandatory data for processing obtained from a single image. Noise in images, and particularly in SEM images, are undesirable. A new noise reduction technique, based on cubic spline interpolation with Savitzky-Golay and weighted least squares error method, is developed. We apply the combined technique to single image signal-to-noise ratio estimation and noise reduction for SEM imaging system. This autocorrelation-based technique requires image details to be correlated over a few pixels, whereas the noise is assumed to be uncorrelated from pixel to pixel. The noise component is derived from the difference between the image autocorrelation at zero offset, and the estimation of the corresponding original autocorrelation. In the few test cases involving different images, the efficiency of the developed noise reduction filter is proved to be significantly better than those obtained from the other methods. Noise can be reduced efficiently with appropriate choice of scan rate from real-time SEM images, without generating corruption or increasing scanning time.

5.
J Microsc ; 253(1): 1-11, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24164248

RESUMO

A new technique based on cubic spline interpolation with Savitzky-Golay noise reduction filtering is designed to estimate signal-to-noise ratio of scanning electron microscopy (SEM) images. This approach is found to present better result when compared with two existing techniques: nearest neighbourhood and first-order interpolation. When applied to evaluate the quality of SEM images, noise can be eliminated efficiently with optimal choice of scan rate from real-time SEM images, without generating corruption or increasing scanning time.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica de Varredura/métodos , Razão Sinal-Ruído , Animais , Culicidae/ultraestrutura , Extremidades/anatomia & histologia
6.
J Microsc ; 248(2): 120-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22900970

RESUMO

A new technique for estimation of signal-to-noise ratio in scanning electron microscope images is reported. The method is based on the image noise cross-correlation estimation model recently developed. We derive the basic performance limits on a single image signal-to-noise ratio estimation using the Cramer-Rao inequality. The results are compared with those from existing estimation methods including the nearest neighbourhood (the simple method), the first order linear interpolator, and the autoregressive based estimator. The comparisons were made using several tests involving different images within the performance bounds. From the results obtained, the efficiency and accuracy of image noise cross-correlation estimation technique is considerably better than the other three methods.

7.
Eur Rev Med Pharmacol Sci ; 26(3): 828-845, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35179749

RESUMO

Sutures are used to facilitate wound healing and play an important role in ensuring the success of surgical interventions in healthcare facilities. Suture-associated surgical site infection (SSI) may develop when bacterial contaminants colonize the suture surface and establish biofilms that are highly resistant to antibiotic treatment. The outcome of SSI affects postoperative care, leading to high rates of morbidity and mortality, prolonged hospitalization, and increased financial burden. Antimicrobial sutures coated with antiseptics such as triclosan and chlorhexidine have been used to minimize the occurrence of SSI. However, as the efficacy of antiseptic-based sutures may be affected due to the emergence of resistant strains, new approaches for the development of alternative antimicrobial sutures are necessary. This review provides an update and outlook of various approaches in the design and development of antimicrobial sutures. Attaining a zero SSI rate will be possible with the advancement in suturing technology and implementation of good infection control practice in clinical settings.


Assuntos
Anti-Infecciosos Locais , Anti-Infecciosos , Triclosan , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Anti-Infecciosos Locais/uso terapêutico , Humanos , Infecção da Ferida Cirúrgica/tratamento farmacológico , Suturas , Triclosan/farmacologia , Triclosan/uso terapêutico
8.
J Microsc ; 237(2): 111-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20096041

RESUMO

Interpolation techniques that are used for image magnification to obtain more useful details of the surface such as morphology and mechanical contrast usually rely on the signal information distributed around edges and areas of sharp changes and these signal information can also be used to predict missing details from the sample image. However, many of these interpolation methods tend to smooth or blur out image details around the edges. In the present study, a Lagrange time delay estimation interpolator method is proposed and this method only requires a small filter order and has no noticeable estimation bias. Comparing results with the original scanning electron microscope magnification and results of various other interpolation methods, the Lagrange time delay estimation interpolator is found to be more efficient, more robust and easier to execute.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica de Varredura/métodos , Areca/ultraestrutura
9.
J Microsc ; 238(1): 44-56, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20384837

RESUMO

An exponential contrast stretching (ECS) technique is developed to reduce the charging effects on scanning electron microscope images. Compared to some of the conventional histogram equalization methods, such as bi-histogram equalization and recursive mean-separate histogram equalization, the proposed ECS method yields better image compensation. Diode sample chips with insulating and conductive surfaces are used as test samples to evaluate the efficiency of the developed algorithm. The algorithm is implemented in software with a frame grabber card, forming the front-end video capture element.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica de Varredura/métodos , Algoritmos , Animais , Culicidae/ultraestrutura , Olho/ultraestrutura
10.
Adv Exp Med Biol ; 680: 593-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20865544

RESUMO

Electroencephalogram (EEG) serves as an extremely valuable tool for clinicians and researchers to study the activity of the brain in a non-invasive manner. It has long been used for the diagnosis of various central nervous system disorders like seizures, epilepsy, and brain damage and for categorizing sleep stages in patients. The artifacts caused by various factors such as Electrooculogram (EOG), eye blink, and Electromyogram (EMG) in EEG signal increases the difficulty in analyzing them. Discrete wavelet transform has been applied in this research for removing noise from the EEG signal. The effectiveness of the noise removal is quantitatively measured using Root Mean Square (RMS) Difference. This paper reports on the effectiveness of wavelet transform applied to the EEG signal as a means of removing noise to retrieve important information related to both healthy and epileptic patients. Wavelet-based noise removal on the EEG signal of both healthy and epileptic subjects was performed using four discrete wavelet functions. With the appropriate choice of the wavelet function (WF), it is possible to remove noise effectively to analyze EEG significantly. Result of this study shows that WF Daubechies 8 (db8) provides the best noise removal from the raw EEG signal of healthy patients, while WF orthogonal Meyer does the same for epileptic patients. This algorithm is intended for FPGA implementation of portable biomedical equipments to detect different brain state in different circumstances.


Assuntos
Eletroencefalografia/estatística & dados numéricos , Algoritmos , Artefatos , Encéfalo/fisiologia , Encéfalo/fisiopatologia , Biologia Computacional , Epilepsia/diagnóstico , Epilepsia/fisiopatologia , Humanos , Valores de Referência , Processamento de Sinais Assistido por Computador
11.
J Microsc ; 236(1): 18-34, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19772533

RESUMO

A new and robust parameter estimation technique, named Gaussian-Taylor interpolation, is proposed to predict the signal-to-noise ratio (SNR) of scanning electron microscope images. The results of SNR and variance estimation values are tested and compared with piecewise cubic Hermite interpolation, quadratic spline interpolation, autoregressive moving average and moving average. Overall, the proposed estimations for noise-free peak and SNR are most consistent and accurate to within a certain acceptable degree compared with the others.

12.
J Microsc ; 234(3): 243-50, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19493101

RESUMO

An improvement to the previously proposed Canny optimization technique for scanning electron microscope image colorization is reported. The additional process is adaptive tuning, where colour tuning is performed adaptively, based on comparing the original luminance values with calculated luminance values. The complete adaptive Canny optimization technique gives significantly better mechanical contrast on scanning electron microscope grey-scale images than do existing methods.


Assuntos
Cor , Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica de Varredura/métodos
13.
Microsc Res Tech ; 71(4): 315-24, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18172898

RESUMO

The mixed Lagrange time-delay estimation autoregressive (MLTDEAR) model is proposed as a solution to estimate image noise variance. The only information available to the proposed estimator is a corrupted image and the nature of additive white noise. The image autocorrelation function is calculated and used to obtain the MLTDEAR model coefficients; the relationship between the MLTDEAR and linear prediction models is utilized to estimate the model coefficients. The forward-backward prediction is then used to obtain the predictor coefficients; the MLTDEAR model coefficients and prior samples of zero-offset autocorrelation values are next used to predict the power of the noise-free image. Furthermore, the fundamental performance limit of the signal and noise estimation, as derived from the Cramer-Rao inequality, is presented.


Assuntos
Aumento da Imagem , Microscopia Eletrônica de Varredura/métodos , Modelos Biológicos , Processamento de Imagem Assistida por Computador , Software , Madeira/ultraestrutura
14.
J Microsc ; 232(2): 313-34, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19017231

RESUMO

Images of scanning electron microscope are usually in the monochrome mode. A simple and user-friendly approach is proposed to improve the mechanical contrast of the scanning electron microscope grey images. Also, most colourization techniques involve image segmentation or region tracking, which tend to degrade the image with fuzzy or complex region boundaries. A technique is proposed, which is a hybrid between the Canny edge detection technique and the optimization technique. Compared with existing methods, the new Canny optimization technique gives satisfactory results for scanning electron microscope images.

15.
Microsc Res Tech ; 70(11): 919-27, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17661362

RESUMO

A new filter is developed for the enhancement of scanning electron microscope (SEM) images. A mixed Lagrange time delay estimation auto-regression (MLTDEAR)-based interpolator is used to provide an estimate of noise variance to a standard Wiener filter. A variety of images are captured and the performance of the filter is shown to surpass the conventional noise filters. As all the information required for processing is extracted from a single image, this method is not constrained by image registration requirements and thus can be applied in real-time in cases where specimen drift is presented in the SEM image.


Assuntos
Aumento da Imagem , Microscopia Eletrônica de Varredura/métodos , Software , Processamento de Imagem Assistida por Computador , Madeira/ultraestrutura
16.
Scanning ; 38(6): 842-856, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27302216

RESUMO

According to the statistic from World Health Organization (WHO), stroke is one of the major causes of death globally. Computed tomography (CT) scan is one of the main medical diagnosis system used for diagnosis of ischemic stroke. CT scan provides brain images in Digital Imaging and Communication in Medicine (DICOM) format. The presentation of CT brain images is mainly relied on the window setting (window center and window width), which converts an image from DICOM format into normal grayscale format. Nevertheless, the ordinary window parameter could not deliver a proper contrast on CT brain images for ischemic stroke detection. In this paper, a new proposed method namely gamma correction extreme-level eliminating with weighting distribution (GCELEWD) is implemented to improve the contrast on CT brain images. GCELEWD is capable of highlighting the hypodense region for diagnosis of ischemic stroke. The performance of this new proposed technique, GCELEWD, is compared with four of the existing contrast enhancement technique such as brightness preserving bi-histogram equalization (BBHE), dualistic sub-image histogram equalization (DSIHE), extreme-level eliminating histogram equalization (ELEHE), and adaptive gamma correction with weighting distribution (AGCWD). GCELEWD shows better visualization for ischemic stroke detection and higher values with image quality assessment (IQA) module. SCANNING 38:842-856, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Infarto Encefálico/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Encéfalo/diagnóstico por imagem , Meios de Contraste , Humanos , Intensificação de Imagem Radiográfica
17.
Scanning ; 38(2): 148-63, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26235517

RESUMO

Noise on scanning electron microscope (SEM) images is studied. Gaussian noise is the most common type of noise in SEM image. We developed a new noise reduction filter based on the Wiener filter. We compared the performance of this new filter namely adaptive noise Wiener (ANW) filter, with four common existing filters as well as average filter, median filter, Gaussian smoothing filter and the Wiener filter. Based on the experiments results the proposed new filter has better performance on different noise variance comparing to the other existing noise removal filters in the experiments.

18.
Scanning ; 38(6): 502-514, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26618491

RESUMO

An improvement to the existing technique of quantifying signal-to-noise ratio (SNR) of scanning electron microscope (SEM) images using piecewise cubic Hermite interpolation (PCHIP) technique is proposed. The new technique uses an adaptive tuning onto the PCHIP, and is thus named as ATPCHIP. To test its accuracy, 70 images are corrupted with noise and their autocorrelation functions are then plotted. The ATPCHIP technique is applied to estimate the uncorrupted noise-free zero offset point from a corrupted image. Three existing methods, the nearest neighborhood, first order interpolation and original PCHIP, are used to compare with the performance of the proposed ATPCHIP method, with respect to their calculated SNR values. Results show that ATPCHIP is an accurate and reliable method to estimate SNR values from SEM images. SCANNING 38:502-514, 2016. © 2015 Wiley Periodicals, Inc.

19.
Scanning ; 38(6): 492-501, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26618303

RESUMO

This paper introduces new development technique to improve the Scanning Electron Microscope (SEM) image quality and we name it as sub-blocking multiple peak histogram equalization (SUB-B-MPHE) with convolution operator. By using this new proposed technique, it shows that the new modified MPHE performs better than original MPHE. In addition, the sub-blocking method consists of convolution operator which can help to remove the blocking effect for SEM images after applying this new developed technique. Hence, by using the convolution operator, it effectively removes the blocking effect by properly distributing the suitable pixel value for the whole image. Overall, the SUB-B-MPHE with convolution outperforms the rest of methods. SCANNING 38:492-501, 2016. © 2015 Wiley Periodicals, Inc.

20.
Scanning ; 27(3): 147-53, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15934507

RESUMO

In this paper, we propose to use the autoregressive (AR)-based interpolator with Wiener filter and apply the idea to scanning electron microscope (SEM) images. The concept for combining the AR-based interpolator with Wiener filtering comes from the essential requirement of Wiener filtering for accurate and consistent estimation of the power of the noise in images prior to filter implementation. The resultant filter is called AR-Wiener filter. The proposed filter is embedded onto the frame grabber card of the scanning electron microscope (SEM) for real-time image processing. Different images are captured using SEM and used to compare the performances of the conventional Wiener and the proposed AR-Wiener technique.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa