Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Cardiothorac Vasc Anesth ; 31(5): 1702-1706, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28826847

RESUMO

OBJECTIVE: The objective of the study was to investigate if the main pulmonary artery (mPA)-to-ascending aorta (AscAo), (mPA:AscAo) ratio could serve as a screening tool in identifying pulmonary artery hypertension (PAH). DESIGN: A prospective observational study. SETTING: Tertiary care center, university hospital. PARTICIPANTS: Fifty-four adult patients undergoing off-pump coronary artery bypass grafting surgery (OPCAB). INTERVENTIONS: mPA and AscAo transverse diameters were measured by transesophageal echocardiography (TEE) and the mean pulmonary arterial pressures (mPAP) were recorded simultaneously using a pulmonary artery catheter. MEASUREMENTS AND MAIN RESULTS: mPA:AscAo ratio demonstrated significant linear correlation with mPAP measured by pulmonary artery catheterization (ie, r = 0.61, confidence interval [CI] = 0.5352-0.6736, p < 0.0001). Receiver operating characteristic curves were performed to evaluate sensitivity and specificity of mPA:AscAo ratio ≥1 for diagnosing PAH (mPAP ≥25 mmHg). Area under the curve for mPA:AscAo ratio was 0.91 (95% CI, 0.869-0.936, p < 0.0001), with a sensitivity of 84.27%, specificity of 83.92%, positive-predictive value of 87.6% and negative-predictive value of 81.1% for a mPAP ≥25 mmHg. CONCLUSIONS: The ratio of mPA:AscAo is a simple, reliable, and reproducible method that can be obtained through TEE, which guides the clinician to screen patients with PAH.


Assuntos
Aorta/diagnóstico por imagem , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Ecocardiografia Transesofagiana/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Ann Card Anaesth ; 26(4): 380-385, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861570

RESUMO

Aim: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON ® with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. Materials and Methods: A prospective observational study was conducted in 25 pediatric patients with age < 10 years who underwent elective cardiac surgery. Data Analysis: BlandAltman plot was constructed for interchangeability and Polar plot was constructed to know trending ability. Results: A total of 250 datasets were analyzed. Spearman's correlation coefficient for CO between ICON ® and TTE showed good positive correlation (r = 0.850, 95% confidence interval 0.81 to 0.881, P <.0001). Moderate positive correlation was observed between ICON ® and TTE for CI (r = 0.60, 95% confidence interval 0.515 to 0.674, P <.0001). Linear regression equations for CO and CI between ICON ® and TTE were: y = 0.5230 + 0.8078 X (R2 = 0.6597, P <.001) and y = 1.8350 + 0.5869 X (R2 = 0.3985, P <.001) [y- ICON ®; X - TTE], respectively. BlandAltman plot for CO between ICON ® and TTE showed a bias of 0.3012 with limits of agreement (LOA) being -0.69 to 1.3 and for CI bias was 0.6939 with LOA-2.1 to 3.5. Polar plot analysis showed an angular bias of 8.1750, with radial LOA being -13.74° to 30.08° for CO and angular bias of 6.6931, with radial LOA being -15.69° to 29.07° for CI. Conclusion: ICON ® monitor-derived parameters are not interchangeable with the values derived from TTE. However, the ICON ® monitor demonstrated a good trending ability for both CO and CI.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia , Criança , Humanos , Débito Cardíaco , Coração , Monitorização Fisiológica , Reprodutibilidade dos Testes , Estudos Prospectivos
3.
Ann Card Anaesth ; 26(2): 155-159, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37706379

RESUMO

Background: Low cardiac output is a common complication following cardiac surgery and it is associated with higher mortality in the pediatric population. A gold standard method for cardiac output (CO) monitoring in the pediatric population is lacking. The present study was conducted to validate cardiac output and cardiac index measured by transthoracic echocardiography and Pressure recording analytical method, a continuous pulse contour method, MostCareUp in postoperative pediatric cardiac surgical patients. Materials and Methods: This was a prospective observational clinical study conducted at a tertiary care hospital. A total of 23 pediatric patients weighed between 2 and 20 kg who had undergone elective cardiac surgery were included in the study. Results: Spearman's correlation coefficient of CO between transthoracic echocardiography (TTE) and Pressure Recording Analytical Method (PRAM) showed of positive correlation (r = 0.69, 95% Confidence interval 0.59-0.77, P < 0.0001) Linear regression equations for CO between TTE and PRAM were y = 0.55 + 0.88x (R2 = 0.46, P < 0.0001). (y = PRAM, x = TTE), respectively. Bland- Altman plot for CO between TTE and PRAM showed a bias of -0.397 with limits of the agreement being -2.01 to 1.22. Polar plot analysis showed an angular bias of 6.55° with radial limits of the agreement being -21.46 to 34.58 for CO and angular bias of 6.22° with radial limits of the agreement being -22.4 to 34.84 for CI. Conclusion: PRAM has shown good trending ability for cardiac output. However, values measured by PRAM are not interchangeable with the values measured by transthoracic echocardiography.


Assuntos
Baixo Débito Cardíaco , Ecocardiografia , Humanos , Criança , Débito Cardíaco , Ecocardiografia/métodos , Monitorização Fisiológica/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Ann Card Anaesth ; 25(1): 26-33, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35075017

RESUMO

OBJECTIVE: Thoracic Epidural Analgesia (TEA) was compared with ultrasound-guided bilateral erector spinae plane (ESP) block in aorto-femoral arterial bypass surgery for analgesic efficacy, hemodynamic effects, and pulmonary rehabilitation. DESIGN: Prospective randomized. SETTING: Tertiary care centre. PARTICIPANTS: Adult patients, who were scheduled for elective aorto-femoral arterial bypass surgery. INTERVENTIONS: It was a prospective pilot study enrolling 20 adult patients who were randomized to group A (ESP block = 10) and group B (TEA = 10). Monitoring of heart rate (HR) and mean arterial pressure (MAP) and pain assessment at rest and deep breathing using visual analog scale (VAS) were done till 48-h post-extubation. Rescue analgesic requirement, Incentive spirometry, oxygenation, duration of ventilation and stay in Intensive Care Unit (ICU) were reported as outcome measures. Statistical analysis was performed using unpaired Student T-test or Mann-Whitney U test. A value of P < 0.05 was considered significant. RESULTS: HR was lower in group B than group A at 1 and 2 h post- surgery and at 0.5, 16, 20, and 32 h post-extubation (P < 0.05). MAP were lower in group B than A at 60, 90, 120, 150, 180, 210, 240, 270 minutes and at 0 hour post-surgery and at 4 hours, every 4 hours till 32 hours post-extubation (P < 0.05). Intraoperative midazolam and fentanyl consumption, ventilatory hours, VAS at rest, incentive spirometry, oxygenation, and ICU stay were comparable between the two groups. VAS during deep breathing was more in group A than B at 0.5, 4 hours and every 4 hours till 44 hours post-extubation. The time to receive the first rescue analgesia was shorter in group A than B (P < 0.05). CONCLUSION: Both ESP block and TEA provided comparable analgesia at rest. Further studies with larger sample size are required to evaluate whether ESP block could be an alternative to TEA in aorto-femoral arterial bypass surgery.


Assuntos
Analgesia Epidural , Bloqueio Nervoso , Adulto , Humanos , Dor Pós-Operatória/tratamento farmacológico , Projetos Piloto , Estudos Prospectivos , Ultrassonografia de Intervenção
6.
Ann Card Anaesth ; 25(3): 330-334, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35799562

RESUMO

Aim: To determine the factors associated with an inadequate response to adenosine infusion during cardiac stress magnetic resonance imaging (MRI). Study Design: It is a retrospective cohort study. Introduction: Stress cardiac MRI is a highly accurate and non-invasive method to diagnose coronary artery disease (CAD). Stress MRI is performed by inducing stress with adenosine infusion. There is an increase in systemic and myocardial blood flow (MBF) with vasodilator agents. Capillaries are maximally dilated in a diseased artery and cannot sustain increased myocardial oxygen demand. It results in delayed delivery of contrast, which leads to an area of perfusion defect in the myocardium. These perfusion defects can be accurately seen by cardiovascular magnetic resonance (CMR) and help in the prognosis of patients. Methods: A retrospective study on patients subjected to cardiac stress MRI was conducted in a Tertiary Care Cardiac Center from January 2019 to January 2022. In total, 99 patients underwent adenosine stress perfusion cardiac MRI. All patients received an adenosine infusion of 140 mcg/kg/min for 2 min. Subsequently, the dosage was increased by 20 mcg/kg/min every 2 min to a maximum of 210 mcg/kg/min until an adequate stress response was achieved. Adequate stress was defined as two or more of the following criteria: 1) Increase in heart rate >/= 10 beats per minute. 2) Decrease in systolic blood pressure SBP by >/= 10 mm Hg Symptoms like chest discomfort, breathlessness, and headache. Patients who satisfied two or more of the above criteria were labeled as responders and the patients who did not satisfy the above criteria with the maximum dose of 210 mcg/kg/min of adenosine infusion were labeled as non-responders. Multivariable logistic regression analysis with forward and backward stepwise selection was used to identify predictors in non-responders. Basic demographic variables with P value

Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Adenosina/farmacologia , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Humanos , Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos , Vasodilatadores
7.
Ann Card Anaesth ; 23(1): 39-42, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929245

RESUMO

Background: Right ventricular (RV) has a vital role in maintaining optimal tissue perfusion. Assessment of portal venous flow characteristics can be alternative and emerging technique to assess RV function. Aims: To investigate if portal venous pulsatility fraction (PF) could serve as effective and complementary tool in identifying RV dysfunction. Materials and Methods: Thirty adult patients aged 18-65 years undergoing cardiac surgery under general anesthesia were enrolled in study. Intraoperative transesophageal echocardiographic examination was performed. Tricuspid annular plane systolic excursion (TAPSE), RV fractional area change (FAC), RV ejection fraction (EF), and portal vein flow pulsatility were assessed. Portal vein PF was used to quantify degree of pulsatility. Results: Portal vein was demonstrated in 27 patients (90%). 27 values of portal vein PF, RV EF, FAC, and TAPSE were analyzed. Portal vein PF demonstrated significant linear correlation with TAPSE (r = -0.55, P = 0.003), RV FAC (r = -0.44, P = 0.02), and RV EF (r = -0.53, P = 0.004). ROC curve was constructed to calculate sensitivity and specificity of portal vein PF for assessing RV function. Portal vein PF value of ≥45% indicated RV dysfunction with sensitivity of 92.3%, specificity of 71.4%, positive predictive value of 75%, and negative predictive value of 90.9%. Area under ROC curve was 0.819 (95% confidence interval = 0.624 - 0.939, P = 0.0006). Conclusion: Portal vein PF is simple and feasible method for assessment of RV function. It complements the existing echocardiographic measures to diagnose RV dysfunction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana/métodos , Veia Porta/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Sensibilidade e Especificidade , Adulto Jovem
8.
Ann Card Anaesth ; 23(2): 165-169, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32275030

RESUMO

Background: Pectoral nerve (PECS1) block has been used for patients undergoing cardiac implantable electronic device (CIED) insertions, however, PECS1 block alone may lead to inadequate analgesia during tunneling and pocket creation because of the highly innervated chest wall. Transversus thoracis muscle plane (TTM) block targeting the anterior branches of T2-T6 intercostal nerves can be effectively used in combination with PECS1 for patients undergoing CIED insertion. The present study hypothesized that combined PECS1 and TTM blocks would provide effective analgesia for patients undergoing CIED insertion compared to PECS1 block alone. Materials and Methods: Thirty adult patients between the age group of 18-85 years undergoing CIED insertion were enrolled in the study. A prospective, randomized, comparative, pilot study was conducted. A total of 30 patients were enrolled, who were randomized to either Group P: PECS1 block (n = 15) or Group PT: PECS1 and TTM blocks (n = 15). The intraoperative requirement of midazolam and local anesthetic and level of sedation by Ramsay sedation score were noted. The pain was assessed by visual analog scale (VAS) at rest and during a cough or deep breathing at 0 h, 3 h, 6 h, 12 h, and 24 h after the procedure. Results: VAS scores at rest were significantly lower in group PT at 0, 3, 6, and 12 h postprocedure, and during cough at 0, 6, and 12 h after the procedure (P < 0.05). At 24 h, VAS scores were comparable between both groups. Intraoperative midazolam consumption was higher in group P compared to group PT (P= 0.002). Fourteen patients in group P received local anesthetic supplementation in comparison to only one patient in group PT (P = 0.0001). Thirteen patients in group P received the first rescue analgesia in comparison to three patients in group PT (P = 0.0003). Conclusion: Combined PECS1 and TTM blocks provide superior analgesia, reduced net consumption of local anesthetic, sedative agents, and rescue analgesics compared to PECS1 block alone in patients undergoing CIED insertion.


Assuntos
Desfibriladores Implantáveis , Bloqueio Nervoso/métodos , Marca-Passo Artificial , Nervos Torácicos/efeitos dos fármacos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
9.
Ann Card Anaesth ; 23(2): 189-192, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32275034

RESUMO

Background: Cardiac output (CO) assessment is a corner stone in advanced haemodynamic management, especially in critical ill patients. The present study was conducted to validate cardiac index and cardiac output by NICaS™ with the thermodilution technique using pulmonary artery catheter in post-operative cardiac surgical patients. Materials and Methods: This was a prospective observational clinical study conducted at a tertiary care hospital. 23 adult patients in the age range of 18-65 years who had undergone for elective coronary artery bypass grafting were included in the study. Results: Spearman's correlation coefficient of cardiac index between continuous Thermodilution (cTD) and Non-Invasive Cardiac System (NICaS™) showed a good correlation (r = 0.765, 95% confidence interval 0.70 to 0.82, P < 0.0001). There was a good correlation between cTD and NICaS™ for cardiac output (r = 0.759, 95% confidence interval 0.69 to 0.81, P < 0.0001), Bland-Altman plot for cardiac index between cTD and NICaS™ showed a mean bias of -0.66 ± 0.6919 with limits of agreement being -2.02 to 0.6936. Bland-Altman plot for cardiac output between cTD and NICaS™ showed a mean bias of -1.0386 ± 1.17 with limits of agreement being -3.34 to + 1.26. Percentage error for cardiac index and cardiac output were 64.78% and 64% respectively. Polar plot analysis showed an angular bias of 6.32° with radial limits of agreement being -8.114° to 20.75° for cardiac index and angular bias of 5.6682° with radial limits of agreement being -9.1422° to 20.4784° for cardiac output. Conclusion: NICaS™ demonstrated a good trending ability for both CI and CO. However, NICaS™ derived parameters are not interchangeable with the values derived from continuous thermodilution technique.


Assuntos
Débito Cardíaco/fisiologia , Procedimentos Cirúrgicos Cardíacos , Cardiografia de Impedância/métodos , Monitorização Intraoperatória/métodos , Adolescente , Adulto , Idoso , Cateterismo de Swan-Ganz , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Termodiluição , Adulto Jovem
10.
Ann Card Anaesth ; 23(3): 327-331, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32687091

RESUMO

Aims and Objectives: The objective of the study was to determine the preconditioning myocardial protective effects of intralipid (IL) in off-pump coronary artery bypass (OPCAB) surgery by measuring highly sensitive troponin T (hsTnT) and cardiac-specific creatine kinase (CK-MB) as markers of myocardial injury. Materials and Methods: : Thirty patients, scheduled to undergo elective OPCAB surgery, were randomly assigned to the IL group (n = 15) or control (C) group (n = 15); the IL group received an infusion of 20% IL 2 ml/kg, 30 min prior to revascularization and the control group received an equivalent volume of normal saline. Serum levels of hsTnT and CK-MB were measured before surgery and at 6 h, 24 h, 48 h, and 72 h postoperatively. Also, intraoperative hemodynamic parameters, inotrope use, ventilatory hours, ICU stay, postoperative left ventricular ejection fraction, postoperative lipid profile, renal and hepatic function tests were measured. Results: The hsTnT values at the 24 h, 48 h, and 72 h in IL group were significantly lower as compared with the control group. The decline in plasma levels of CK-MB mirrored the hsTnT levels post revascularization at 24 h and 48 h in the IL group compared with the control group; however, at 72 h, level was comparable in both the groups. None of the treated patients had abnormal lipid metabolism, deranged renal, and hepatic function. Conclusion: The study revealed Intralipid as a safe pharmacological preconditioning agent for OPCAB surgeries which can reduce the postischemic myocardial injury indicated by the reduction in postischemic cardiac enzymes hsTnT and CK-MB.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Emulsões Gordurosas Intravenosas/administração & dosagem , Precondicionamento Isquêmico Miocárdico/métodos , Fosfolipídeos/administração & dosagem , Óleo de Soja/administração & dosagem , Biomarcadores/sangue , Creatina Quinase Forma MB/sangue , Emulsões/administração & dosagem , Emulsões Gordurosas Intravenosas/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fosfolipídeos/sangue , Óleo de Soja/sangue , Troponina I/sangue
11.
Ann Card Anaesth ; 23(1): 34-38, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929244

RESUMO

Background: The deceleration time of the pulmonary venous diastolic flow has been well-correlated with invasive pulmonary capillary wedge pressure in several studies regardless of left ventricular systolic function. This study was conducted to correlate deceleration time of pulmonary venous diastolic wave, DT(D), and left atrial pressure (LAP), obtained noninvasively from mitral early diastolic inflow velocity-to-early diastolic mitral annulus velocity ratio (E/e'), and to assess the ease of each method in patients with coronary artery disease undergoing off-pump coronary artery bypass grafting (OPCAB) by transesophageal echocardiography. Methods: Forty-five adult patients with coronary artery disease, with left ventricular ejection fraction of ≥50% posted for elective OPCAB were enrolled in the study. Results: Forty values of LAP and DT(D) were analyzed. A significant linear correlation (r = -0.64) was found between DT(D) and LAP. Area under the curve of DT(D) of ≤183 ms for predicting elevated LAP (>15) was 0.903 (95% confidence interval: 0.767 to 0.974, P < 0.0001). Conclusion: Deceleration time of pulmonary venous flow diastolic waveform, DT(D), feasible promising echocardiographic measure in determining elevated LAP and DT(D)≤183 ms predicts elevated LAP.


Assuntos
Pressão Atrial/fisiologia , Ponte de Artéria Coronária , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Ecocardiografia Transesofagiana/métodos , Veias Pulmonares/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Reprodutibilidade dos Testes
12.
Ann Card Anaesth ; 23(1): 43-47, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929246

RESUMO

Background: Medullary hypoxia is the initial critical event for kidney injury during cardiopulmonary bypass, and therefore urinary PO2 with its potential of detecting medullary oxygenation for its management. Therefore, we tested the role of urinary PO2 in predicting kidney injury in those undergoing conventional versus combined (conventional and modified) ultrafiltration during cardiac surgery in adults. Methodology: We prospectively evaluated 32 adults between 18 and 65 years of age undergoing elective on-pump cardiac surgery with ejection fraction >35% by conventional (group C) versus combined ultrafiltration (group CM). Urine samples were analyzed for PO2 after induction, 30 min, 3 h, and 6 h post filtration along with blood urea and serum creatinine after induction, at 6 h, 24 h, and 48 h post filtration. Demographic variables, cardiopulmonary bypass duration, flow rates, inotropic score, ventilation duration, diuretic use, and intensive care unit (ICU) stay were assessed between two groups. Results: Both the groups (16 in each group) had comparable urinary PO2 after induction (P = 0.387) with significant decrease in group C at 30 min, 3 h, and 6 h post filtration (P < 0.05). There was a statistically significant increase in serum creatinine (mg/dL) at 48 h in group C compared with group CM (1.57 vs. 1.25, respectively; P ≤ 0.05). There was an increased diuretic usage and length of ICU stay in group C. Conclusion: Combined ultrafiltration technique had renoprotective effect in cardiac surgery analyzed by urinary PO2 levels.


Assuntos
Injúria Renal Aguda/urina , Procedimentos Cirúrgicos Cardíacos , Hipóxia/urina , Oxigênio/urina , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrafiltração/métodos , Adulto Jovem
13.
Ann Card Anaesth ; 22(1): 101-106, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30648692

RESUMO

Background: : Autonomic dysfunction (AD) is infrequently evaluated preoperatively despite having profound perioperative implications. The ANSiscope™ is a monitoring device that quantifies AD. This study aims to determine the potential of the device to predict hypotension following anesthetic induction, occurrence of arrhythmias, and inotrope requirement for patients undergoing off-pump coronary artery bypass surgery (OPCAB). Study Design: : Prospective observational double-blinded study. Materials and Methodology: Seventy-five patients undergoing OPCAB had their autonomic function assessed by ANSiscope™. They were classified into four groups based on their AD and compared to perioperative adverse events. Results: Patients with diabetes had a higher ANSindex (P = 0.0263). They had a greater decrease in systolic blood pressure (P = 0.001) and mean arterial pressure (P = 0.004) postinduction, had an increased incidence of arrhythmias (P = 0.009), required higher inotropic support immediately (P = 0.010) and at 24 h after surgery (P = 0.018), and longer duration of postoperative ventilation (P < 0.001). They also had a higher incidence of emergency conversion of OPCAB to on-pump surgery (P = 0.009). Conclusions: An increased association between AD as quantified by the ANSiscope™ and perioperative adverse outcomes was observed. An increased rate of emergency conversion of OPCAB to on-pump surgery with higher dysfunction was noted. The authors opine that the threshold for conversion must be lower in patients deemed to be at a higher risk. Proper evaluation of the autonomic nervous system empowers the anesthesiologist to anticipate and adequately prepare for complications.


Assuntos
Anestesia em Procedimentos Cardíacos , Doenças do Sistema Nervoso Autônomo/diagnóstico , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Idoso , Doenças do Sistema Nervoso Autônomo/complicações , Doenças do Sistema Nervoso Autônomo/terapia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos
14.
Ann Card Anaesth ; 22(1): 73-78, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30648683

RESUMO

Objective: Allogeneic blood product transfusions are associated with an increased morbidity and mortality risk in cardiac surgery. At present, a few transfusion risk scores have been proposed for cardiac surgery patients. The present study is aimed to develop a new score and to compare with preexisting scores - Transfusion Risk and Clinical Knowledge (TRACK) and Transfusion Risk Understanding Scoring Tool (TRUST) score. Methodology: A total of 1014 adult patients undergoing cardiac surgery were enrolled in the retrospective study. Independent predictors of allogeneic blood transfusions were selected from TRACK and TRUST scores. A predictive score was developed from six variables using logistic regression analysis, and new score was compared to the other existing scores - TRACK and TRUST. Results: The new score had following predictors: age >58 years, weight <63 kg for males and <49 kg for females, gender (female), complex surgery, hemoglobin <13.5 g/dl, and creatinine >1.36 mg/dl. Validation of new score demonstrated an acceptable predictive power (area under the curve [AUC] 0.749) and a good calibration at the Hosmer-Lemeshow test. New score was comparable with TRACK score with P = 0.578 (AUC of TRACK 0.756 and AUC of new score 0.749). There was a significant difference between new score and TRUST score, P = 0.01 (AUC of TRUST 0.72 and AUC of new score 0.749). Conclusion: New score is a simple risk model based on six predictors having a similar accuracy and calibration in predicting the transfusion rate in cardiac surgery as compared to TRACK score.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Reação Transfusional , Adulto , Idoso , Calibragem , Creatinina/sangue , Transfusão de Eritrócitos/efeitos adversos , Feminino , Hemoglobinas/análise , Humanos , Conhecimento , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco
15.
Indian J Anaesth ; 62(2): 136-138, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29491520

RESUMO

Eventration of the diaphragm is a rare entity, characterised by abnormal elevation of a dome of diaphragm. In this condition, the diaphragm is composed of fibrous tissue with few or no interspersed muscle fibres. Eventration can be congenital or acquired. Congenital eventration results from inadequate development of muscles or absence of phrenic nerve. The common cause of acquired eventration is injury to the phrenic nerve from traumatic birth injury or surgery for heart disease. The perioperative anaesthetic management of diaphragmatic eventration along with ventricular septal defect with severe pulmonary hypertension makes this case both challenging and unique.

16.
Ann Card Anaesth ; 21(4): 455-459, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30333349

RESUMO

BACKGROUND: Acute kidney injury (AKI) is a strong predictor of morbidity and mortality after cardiac surgery. Lack of valid early biomarkers for predicting AKI has hampered the ability to take therapeutic measures for preventive cause. Hyperphosphatemia that occurs in AKI due to renal excretion defect was not studied in this context and could be simple marker of AKI. Therefore, we tested role of serum phosphorus in prediction of AKI as a biomarker after cardiac surgery in children. METHODOLOGY: We prospectively evaluated 51 children aged between 3 weeks and 12 years undergoing elective cardiac surgery. Serum creatinine and phosphorus were measured preoperatively and postoperatively at 24 and 48 h. As per the Kidney Disease Improving Global Outcomes criteria, patients were grouped into AKI and non-AKI on the basis of the development of AKI within 48 h postsurgery. The postoperative diagnostic performance of phosphorus thresholds was analyzed by the area under receiver operating characteristic curves (AUC-ROC). RESULTS: From 51 children included, 10 developed AKI. In AKI group, serum phosphorus increased significantly from 4.47 ± 0.43 baseline to 6.29 ± 0.32 at 24 h postsurgery (P = 0.01) while serum creatinine increased from baseline 0.33 (0.24-0.46) to 0.49 (0.26-0.91) at 24 h which is statistically insignificant (P = 0.16). ROC analysis showed that serum phosphorus at 24 h, the AUC was 0.84 with sensitivity 0.75 and specificity 0.93 for a cutoff value of 6.4 mg/dl. Whereas serum phosphorus at 48 h, the AUC was 0.86 with sensitivity 66.67% and specificity 97.62% for a cutoff value of 5.4 mg/dl. CONCLUSION: Serum phosphorus can be an alternative biomarker as early as 24 h for early prediction of AKI in pediatric cardiac surgery.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/diagnóstico , Biomarcadores/sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fósforo/sangue , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico , Criança , Pré-Escolar , Creatinina/sangue , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Ann Card Anaesth ; 21(3): 323-327, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30052229

RESUMO

OBJECTIVE: Continuous thoracic epidural analgesia (TEA) is compared with erector spinae plane (ESP) block for the perioperative pain management in patients undergoing cardiac surgery for the quality of analgesia, incentive spirometry, ventilator duration, and intensive care unit (ICU) duration. METHODOLOGY: A prospective, randomized comparative clinical study was conducted. A total of 50 patients were enrolled, who were randomized to either Group A: TEA (n = 25) or Group B: ESP block (n = 25). Visual analog scale (VAS) was recorded in both the groups during rest and cough at the various time intervals postextubation. Both the groups were also compared for incentive spirometry, ventilator, and ICU duration. Statistical analysis was performed using the independent Student's t-test. A value of P < 0.05 was considered statistically significant. RESULTS: C: omparable VAS scores were revealed at 0 h, 3 h, 6 h, and 12 h (P > 0.05) at rest and during cough in both the groups. Group A had a statistically significant VAS score than Group B (P ≤ 0.05) at 24 h, 36 h, and 48 h but mean VAS in either of the Group was ≤4 both at rest and during cough. Incentive spirometry, ventilator, and ICU duration were comparable between the groups. CONCLUSION: ESP block is easy to perform and can serve as a promising alternative to TEA in optimal perioperative pain management in cardiac surgery.


Assuntos
Analgesia Epidural/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Bloqueio Nervoso/métodos , Manejo da Dor/métodos , Nervos Espinhais , Adulto , Idoso , Analgesia Controlada pelo Paciente , Cuidados Críticos , Feminino , Humanos , Período Intraoperatório , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Respiração Artificial , Espirometria , Esternotomia , Ultrassonografia de Intervenção
18.
Ann Card Anaesth ; 21(3): 333-338, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30052231

RESUMO

BACKGROUND: Good postoperative analgesia in cardiac surgical patients helps in early recovery and ambulation. An alternative to parenteral, paravertebral, and thoracic epidural analgesia can be pectoralis nerve (Pecs) block, which is novel, less invasive regional analgesic technique. AIMS: We hypothesized that Pecs block would provide superior postoperative analgesia for patients undergoing cardiac surgery through midline sternotomy compared to parenteral analgesia. MATERIALS AND METHODS: Forty adult patients between the age groups of 25 and 65 years undergoing coronary artery bypass grafting or valve surgeries through midline sternotomy under general anesthesia were enrolled in the study. Patients were randomly allocated into two groups with 20 in each group. Group 1 patients did not receive Pecs block, whereas Group 2 patients received bilateral Pecs block postoperatively. Patients were extubated once they fulfilled extubation criteria. Ventilator duration was recorded. Patients were interrogated for pain by visual analog scale (VAS) scoring at rest and cough. Inspiratory flow rate was assessed using incentive spirometry. RESULTS: Pecs group patients required lesser duration of ventilator support (P < 0.0001) in comparison to control group. Pain scores at rest and cough were significantly low in Pecs group at 0, 3, 6, 12, and 18 h from extubation (P < 0.05). At 24 h, VAS scores were comparable between two groups. Peak inspiratory flow rates were higher in Pecs group as compared to control group at 0, 3, 6, 12, 18, and 24 h (P < 0.05). Thirty-four episodes of rescue analgesia were given in control group, whereas in Pecs group, there were only four episodes of rescue analgesia. CONCLUSION: Pecs block is technically simple and effective technique and can be used as part of multimodal analgesia in postoperative cardiac surgical patients for better patient comfort and outcome.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Bloqueio Nervoso , Dor Pós-Operatória/tratamento farmacológico , Nervos Torácicos , Adulto , Idoso , Analgesia Controlada pelo Paciente , Ponte de Artéria Coronária , Tosse/complicações , Tosse/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Respiração Artificial , Espirometria , Esternotomia
19.
Indian J Anaesth ; 61(8): 676-678, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28890565

RESUMO

First described in 1908, anomalous origin of left coronary artery from pulmonary artery is a very rare congenital anomaly. Here, the right coronary artery is usually enlarged and has a normal origin from aorta. Numerous collaterals connect the two coronary arteries over right ventricular outflow tract or interventricular septum. It is one of the most common causes of myocardial ischaemia and infarction in children.

20.
Anesth Essays Res ; 11(1): 228-232, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28298790

RESUMO

BACKGROUND: Radial artery cannulation is a skillful procedure. An experienced anesthesiologist might also face difficulty in cannulating a feeble radial pulse. AIM: The purpose of the study was to determine whether periradial subcutaneous administration of papaverine results in effective vasodilation and improvement in the palpability score of radial artery. SETTINGS AND DESIGN: Prospective, double-blinded trial. METHODOLOGY: Thirty patients undergoing elective cardiac surgery were enrolled in the study. 30 mg of papaverine with 1 ml of 2% lignocaine and 3 ml of normal saline were injected subcutaneously 1-2 cm proximal to styloid process of the radius. Radial artery diameter before and after 20 min of injection papaverine was measured using ultrasonography. The palpability of the radial pulse was also determined before the injection of papaverine and 20 min later. Patients were monitored for hemodynamics and any complications were noted. STATISTICAL ANALYSIS USED: Student's t-test for paired data. RESULTS: Radial artery diameter increased significantly (P < 0.0001), and the pulse palpability score also showed statistically significant improvement (P < 0.0001) after periradial subcutaneous administration of papaverine. There was no statistically significant difference in heart rate, mean arterial blood pressure before and after papaverine injection. No complications were noted in 24 h of follow-up. CONCLUSION: Periradial subcutaneous administration of papaverine significantly increased the radial artery diameter and pulse palpability score, which had an impact on ease of radial artery cannulation essential for hemodynamic monitoring in cardiac surgical patients.

SELEÇÃO DE REFERÊNCIAS