Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Neurourol Urodyn ; 38(1): 248-253, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30311667

RESUMO

AIMS: This paper presents 4-year follow-up results for patients enrolled in a pivotal study conducted to support an FDA premarket approval application (PMAA). The study evaluated the safety and efficacy of the ProACT Adjustable Continence Therapy for the treatment of post-prostatectomy stress urinary incontinence (SUI). METHODS: The clinical study involved 11 clinical sites and enrolled 160 subjects, all male. A total of 124 subjects met study criteria and 123 were implanted with ProACT. Baseline and outcomes for 68 patients who completed 4-year follow-up visits are reported. Endpoints included 24-h pad weight, Incontinence Quality of Life Questionnaire (I-QOL), UCLA Prostate Cancer Index-Urinary Function (PCI-UF), residual volume, and incidence and severity of device or procedure-related adverse events. RESULTS: Statistically significant improvements during follow-up were observed in 24-h pad weight, for which the mean pre-implant urine loss was 293 g, which was reduced at 4 years to 73 g (P < 0.001). Reductions in pad weight were observed across all levels of pre-implant SUI severity. Significant improvements were also seen in quality of life as measured by the I-QOL (P < 0.001) as well as measures of urinary function and pad use. One procedure-related SAE (retention) was reported among the 68 subjects; the SAE was resolved without clinical meaningful sequalae. CONCLUSIONS: These results confirm the long-term safety and efficacy of this newly FDA-approved therapy, showing significant improvements in both objective and subjective measures of SUI in mild, moderate, and severely incontinent male patients. The implant procedure is minimally invasive, and complications are generally mild and easily resolvable.


Assuntos
Prostatectomia/efeitos adversos , Próteses e Implantes , Incontinência Urinária por Estresse/cirurgia , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Neoplasias da Próstata/cirurgia , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento , Incontinência Urinária por Estresse/etiologia
2.
Neurourol Urodyn ; 37(8): 2854-2859, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30178536

RESUMO

AIMS: This paper presents 18-month follow-up results for patients enrolled in a pivotal study conducted to support an FDA premarket approval application (PMAA). The trial evaluated the safety and efficacy of the ProACT Adjustable Continence Therapy for the treatment of post-prostatectomy stress urinary incontinence (SUI). METHODS: The clinical study involved 11 clinical sites and enrolled 160 subjects. A total of 124 subjects met study criteria and 123 underwent ProACT implantation from July 2005 through June 2007, of whom 98 completed 18-month follow-up. Endpoints included 24-h pad weight, Incontinence Quality of Life Questionnaire (I-QOL), UCLA Prostate Cancer Index-Urinary Function (PCI-UF), residual volume, and device or procedure-related adverse events (AEs). RESULTS: The mean surgical time was 32 min. Statistically significant improvements during follow-up were observed in 24-h pad weight, for which the cohort mean pre-implant urine loss was 399 g, which was reduced at 18 months to 160 g (P < 0.001). Reductions in pad weight were observed across all levels of pre-implant SUI severity. Significant improvements were also seen in quality of life as measured by the I-QOL (P < 0.001) as well as measures of urinary function and pad count. One procedure-related serious adverse event (SAE), retention, was reported among the 124 subjects; the SAE was resolved without clinical meaningful sequalae. CONCLUSIONS: These results demonstrate the safety and efficacy of this newly FDA-approved therapy, showing significant improvements in objective and subjective measures of SUI in mild, moderate, and severely incontinent male patients. The duration of the implant procedure is short, and complications are mild and easily resolvable.


Assuntos
Complicações Pós-Operatórias/cirurgia , Prostatectomia/efeitos adversos , Próteses e Implantes , Incontinência Urinária por Estresse/cirurgia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Neoplasias da Próstata/cirurgia , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento , Incontinência Urinária por Estresse/etiologia
3.
World J Urol ; 29(2): 249-53, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20959993

RESUMO

INTRODUCTION: Treatment of recurrent stress incontinence after a failed surgical procedure is more complicated, and repeat surgeries have higher rates of complications and limited efficacy. We determined the technical feasibility, efficacy, adjustability, and safety of adjustable continence therapy device for treatment of moderate to severe recurrent urinary incontinence after failed surgical procedure. MATERIALS AND METHODS: Female patients with moderate to severe recurrent stress urinary incontinence who had at least one prior surgical procedure for incontinence were enrolled. All patients underwent percutaneous placement of adjustable continence therapy (ACT) device (Uromedica, Plymouth, Minnesota). Baseline and regular follow-up tests to determine subjective and objective improvement were performed. RESULTS: A total of 89 patients have undergone implantation with 1-3 years of follow-up. Data are available on 77 patients at 1 year. Of the patients, 47% were dry at 1 year and 92% improved after 1-year follow-up. Stamey score improved from 2.25 to 0.94 at 1 year (P < 0.001). IQOL questionnaire scores improved from 33.9 to 71.6 at 1 year (P < 0.001). UDI scores reduced from 60.7 to 33.3 (P < 0.001) at 1 year. IIQ scores reduced from 57.0 to 21.6 (P < 0.001) at 1 year. Diary incontinence episodes per day improved from 8.1 to 3.9 (P < 0.001) at 1 year. Diary pads used per day improved from 4.3 to 1.9 (P < 0.001). Explantation was required in 21.7% of patients. CONCLUSION: The ACT device is an effective, simple, safe, and minimally invasive treatment for moderate to severe recurrent female stress urinary incontinence after failed surgical treatment.


Assuntos
Equipamentos e Provisões , Índice de Gravidade de Doença , Incontinência Urinária por Estresse/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Equipamentos e Provisões/efeitos adversos , Estudos de Viabilidade , Feminino , Seguimentos , Procedimentos Cirúrgicos em Ginecologia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Prevenção Secundária , Falha de Tratamento , Resultado do Tratamento , Procedimentos Cirúrgicos Urológicos
4.
J Urol ; 181(5): 2187-91, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19296967

RESUMO

PURPOSE: We determined the efficacy, safety, adjustability and technical feasibility of the adjustable continence therapy device (Uromedica, Plymouth, Minnesota) for the treatment of recurrent female stress urinary incontinence. MATERIALS AND METHODS: Female patients with recurrent stress urinary incontinence were enrolled in the study and a defined set of exclusionary criteria were followed. Baseline and regular followup tests to determine eligibility, and to measure subjective and objective improvement were performed. A trocar was passed fluoroscopically and with digital vaginal guidance to the urethrovesical junction through small incisions between the labia majora and minora. The adjustable continence therapy device was delivered and the balloons were filled with isotonic contrast. The injection ports for balloon inflation were placed in a subcutaneous pocket in each labia majora. Device adjustments were performed percutaneously in the clinic postoperatively. An approved investigational device exemption Food and Drug Administration protocol was followed to record all adverse events. RESULTS: A total of 162 subjects underwent implantation with 1 year of data available on 140. Mean Stamey score improved by 1 grade or more in 76.4% (107 of 140) of subjects. Improvement in the mean incontinence quality of life questionnaire score was noted at 36.5 to 70.7 (p <0.001). Reductions in mean Urogenital Distress Inventory (60.3 to 33.4) and Incontinence Impact Questionnaire (54.4 to 23.4) scores also occurred (p <0.001). Mean provocative pad weight decreased from 49.6 to 11.2 gm (p <0.001). Of the patients 52% (67 of 130) were dry at 1 year (less than 2 gm on provocative pad weight testing) and 80% (102 of 126) were improved (greater than 50% reduction on provocative pad weight testing). Complications occurred in 24.4% (38 of 156) of patients. Explantation was required in 18.3% (28 of 153) of the patients during 1 year. In terms of the complications 96.0% were considered to be mild or moderate. CONCLUSIONS: The Uromedica adjustable continence therapy device is an effective, simple, safe and minimally invasive treatment for recurrent female stress urinary incontinence. It can be easily adjusted percutaneously to enhance efficacy and complications are usually easily manageable. Explantation does not preclude later repeat implantation.


Assuntos
Próteses e Implantes , Implantação de Prótese/instrumentação , Qualidade de Vida , Incontinência Urinária por Estresse/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Satisfação do Paciente , Probabilidade , Desenho de Prótese , Implantação de Prótese/métodos , Recidiva , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Cateterismo Urinário , Incontinência Urinária por Estresse/diagnóstico , Urodinâmica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa