Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Gynaecol Obstet ; 91(3): 246-51, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16242695

RESUMO

OBJECTIVE: To compare the cure rate and confirm the clinical efficacy of the 3 most frequently performed surgical procedures for stress urinary incontinence (SUI). METHODS: Between January 2001 and May 2003, 92 women with SUI were randomly assigned to undergo the Burch colposuspension (n=33), pubovaginal sling (n=28), or tension-free vaginal tape (n=31) at the Department of Obstetrics and Gynecology, Yonsei Medical Center, Seoul, Korea. Patient characteristics, urodynamic study results, cure rates at 3, 6, and 12 months, and complication rates were compared using the chi2 test. RESULTS: There were no statistically significant differences in the cure rates initially, but after 12 months the cure rate of the pubovaginal sling procedure was found to be significantly higher than those of the tension-free vaginal tape or Burch colposuspension procedures. CONCLUSION: The cure rate of the pubovaginal sling procedure was significantly higher after 1 year, but no difference in efficacy was observed between the 2 other procedures. A randomized prospective study of a larger population should be conducted.


Assuntos
Bexiga Urinária/cirurgia , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Próteses e Implantes , Resultado do Tratamento , Urodinâmica
2.
Med Phys ; 16(5): 800-2, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2509871

RESUMO

Measurements have been made to determine scatter factor corrections for elongated fields of Cobalt-60 and for nominal linear accelerator energies of 6 MV (Siemens Mevatron 67) and 18 MV (AECL Therac 20). It was found that for every energy the collimator scatter factor varies by 2% or more as the field length-to-width ratio increases beyond 3:1. The phantom scatter factor is independent of which collimator pair is elongated at these energies. For 18 MV photons it was found that the collimator scatter factor is complicated by field-size-dependent backscatter into the beam monitor.


Assuntos
Radioterapia de Alta Energia , Espalhamento de Radiação , Física Médica , Humanos , Modelos Estruturais , Radiometria , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa