Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Musculoskelet Disord ; 15: 189, 2014 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-24885741

RESUMO

BACKGROUND: The importance of the tip-apex distance (TAD) to predict the cut-out risk of fixed angle hip implants has been widely discussed in the scientific literature. Intra-operative determination of TAD is difficult and can be hampered by image quality, body habitus, and image projection. The purpose of this paper is to evaluate, through a cadaveric study, a novel computer assisted surgery system (ADAPT), which is intended for intraoperative optimisation of lag screw positioning during antegrade femoral nailing. A 3D measure for optimal lag screw position, the tip-to-head-surface distance (TSD), is introduced. METHODS: 45 intra-medullary hip screw procedures were performed by experienced and less experienced surgeons in a cadaveric test series: in 23 surgeries the ADAPT system was used, and in 22 it was not used. The position of the lag screw within the femoral head and neck was evaluated using post-operative CT scans. TAD, TSD, fluoroscopy as well as procedure time and variability were assessed. RESULTS: The use of the ADAPT system increased accuracy in TSD values (i.e. smaller variability around the target value) for both groups of surgeons (interquartile range (IQR) of experienced surgeons: 4.10 mm (Conventional) vs. 1.35 mm (ADAPT) (p = 0.004)/IQR of less experienced surgeons: 3.60 mm (Conventional) vs. 0.85 mm (ADAPT) (p = 0.002)). The accuracy gain in TAD values did not prove to be significant in the grouped analysis (p = 0.269 for experienced surgeons; p = 0.066 for less experienced surgeons); however, the overall analysis showed a significant increase in accuracy (IQR: 4.50 mm (Conventional) vs. 2.00 mm (ADAPT) (p = 0.042)). The fluoroscopy time was significantly decreased by the use of the ADAPT system with a median value of 29.00 seconds (Conventional) vs. 17.00 seconds (ADAPT) for the less experienced surgeons (p = 0.046). There was no statistically significant impact on the procedure time (p = 0.739). CONCLUSIONS: The ADAPT system improved the position of the lag screw within the femoral head, regardless of the surgeon's level of clinical experience, and at the same time decreased overall fluoroscopy usage. These positive effects are achieved without increasing procedure time.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Cirurgia Assistida por Computador/métodos , Pontos de Referência Anatômicos , Parafusos Ósseos , Cadáver , Competência Clínica , Fraturas do Fêmur/diagnóstico por imagem , Fluoroscopia , Fixação Interna de Fraturas/instrumentação , Humanos , Duração da Cirurgia , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X
2.
J Trauma ; 67(1): 8-13; discussion 13, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19590301

RESUMO

BACKGROUND: Chest wall implosion injuries secondary to side impact are unusual but devastating injuries. The purpose of this series is to describe the clinical entity, present a surgical technique to reduce and repair the thoracic cage deformity without thoracotomy, and report outcomes in nine patients. STUDY: Institutional review board approved retrospective case series, surgical technique. SETTING: Level I Trauma Center. METHODS: Twenty-two patients were admitted during 7-year period with thoracic cage implosion injuries and multiple segmental rib fractures from a side impact mechanism. All patients' required mechanical ventilation and had an implosion deformity along the posterolateral thoracic cage, pulmonary contusion, and clavicular fractures. Nine patients underwent repair of rib fractures through a paramidline posterior approach without thoracotomy using standard 2.4-mm titanium plates. Seven patients with similar fracture pattern treated nonoperatively were used as a historical control. Total intubation time, intensive care unit (ICU) length of stay (LOS), and final shoulder function using the Constant Murley scoring system were compared between the two groups. RESULTS: Average age, male to female ratio, and injury severe score were comparable for both cohorts (p > 0.6). Average follow-up was 16 months versus 12 months for the operative and nonoperative groups, respectively, (p = 0.11). In the operative group, 8 of 9 (89%) patients were extubated within 24 hours of surgery; 3 of 9 (33%) were extubated in the operating room. In the operative group, seven patients underwent internal fixation of the clavicle and progressed to union with a mean Constant score of 93. Nine patients had nonoperative treatment of the clavicle with a mean Constant score of 75 (p = 0.04). Total intubation time (1.9 days) was significantly shorter in the operative group than the nonoperative controls at 13.3 days (p < 0.01) and length of ICU stay was also shortened at 5.7 (4-8) days versus 16.7 (10-26) days, respectively, (p < 0.01). CONCLUSION: Chest wall implosion injuries with fixed deformities of the thoracic cage, multiple segmental rib fractures, and clavicular injury are a distinct clinical entity, which can be effectively managed with a posterior paramidline approach without thoracotomy. Reduction of the deformity and repair of the rib fractures led to a dramatic reduction in time to extubation, ICU LOS, and in-hospital complications including pneumonia and sepsis. Repair of the clavicular fracture appeared to be beneficial.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas das Costelas/cirurgia , Parede Torácica/lesões , Ferimentos não Penetrantes/cirurgia , Acidentes de Trânsito , Adulto , Placas Ósseas , Seguimentos , Hemotórax/diagnóstico , Hemotórax/etiologia , Hemotórax/cirurgia , Humanos , Masculino , Radiografia Torácica , Estudos Retrospectivos , Fraturas das Costelas/complicações , Fraturas das Costelas/diagnóstico por imagem , Parede Torácica/diagnóstico por imagem , Parede Torácica/cirurgia , Toracotomia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem
3.
Clin Orthop Relat Res ; 467(4): 929-33, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18800211

RESUMO

UNLABELLED: The optimal surgical approach for combined femoral head and acetabular fractures (Pipkin IV) is controversial because of their rarity and lack of definitive reports. Surgical dislocation with trochanteric flip osteotomy (TFO) allows simultaneous exposure of the acetabulum and femoral head. We protected the obturator internus and inferior capsule during repair with a heavy suture at the inferior extent of the traumatic capsulotomy. We retrospectively reviewed 12 patients with Pipkin IV fractures treated using this approach during a 6-year period. The minimum followup was 24 months (mean, 47 months; range, 24-71 months). Clinical outcomes were measured using the Merle d'Aubigné-Postel and Thompson-Epstein scoring scales. Radiographically, all patients achieved healing of their acetabular fractures; 11 achieved healing of the femoral head fracture and osteonecrosis developed in one patient. The average Merle d'Aubigné-Postel score was 15.6 of 18; using the Thompson-Epstein score, 10 of the 12 patients had good or excellent outcomes, one had a fair outcome, and one had a poor outcome. Trochanteric flip osteotomy allowed for simultaneous exposure and repair of both lesions in Pipkin IV fractures. Using a uniform surgical protocol with TFO rendered clinical results comparable to previously reported outcomes in series of isolated femoral head fractures. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/cirurgia , Cabeça do Fêmur/cirurgia , Consolidação da Fratura , Fraturas do Quadril/cirurgia , Osteotomia/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Atividades Cotidianas , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/lesões , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Osteotomia/efeitos adversos , Medição da Dor , Complicações Pós-Operatórias , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Caminhada
4.
J Orthop Trauma ; 23(2): 113-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19169103

RESUMO

OBJECTIVES: The use of locked plates in repairing osteopenic 3- and 4-part proximal humerus fractures remains controversial. The purpose of this article was to report the outcomes of open reduction and internal fixation in low-energy proximal humerus fractures treated with locked plating in patients older than 55 years and stratify risk of failure or complication based on initial radiographic features. DESIGN: Retrospective. SETTING: Level I Trauma Center. METHODS: Seventy patients older than 55 years undergoing locked plate fixation for Neer 3- or 4-part proximal humerus fractures were studied retrospectively. All patients had standardized, true size digital radiographs of the injured and normal shoulder in the axillary, scapular Y, and 20-degree external rotation views with a minimum of 18 months' clinical follow-up. Two groups were identified based on the initial direction of the humeral head deformity: varus or valgus impaction. There were no statistical differences between treatment groups with regard to age, sex, Neer classification, follow-up, or dislocation. Radiographic measurements included humeral head angulation, tuberosity displacement, and length of the intact metaphyseal segment. Clinical outcomes measured Constant scores (CS) using active range of motion at latest follow-up. RESULTS: Twenty-four patients with initial varus fracture patterns healed with an average of 16-degree varus head angulation and an overall CS of 63 at an average of 34 months' follow-up. Forty-six patients with initial valgus fracture patterns healed with an average of 6 degrees of varus angulation and an overall CS of 71 at an average of 37 months' follow-up (P < 0.01). Complications of avascular necrosis, humeral head perforation, loss of fixation, tuberosity displacement >5 mm, and varus subsidence >5 degrees were encountered in 19 of 24 (79%) in the varus group compared with 9 of 46 (19%) in the valgus group (P < 0.01). Final CSs for 3-part fractures were 65 versus 72 (P < 0.01) for varus and valgus groups, respectively, and 61 versus 69 (P = 0.19) for 4-part fractures. CONCLUSIONS: Neer 3- and 4-part proximal humeral fractures in older patients with initial varus angulation of the humeral head had a significantly worse clinical outcome and higher complication rate than similar fracture patterns with initial valgus angulation. Two factors had significant influence on final outcome in these fracture patterns: initial direction of the humeral head angulation and length of the intact metaphyseal segment attached to the articular fragment. The best clinical outcomes were obtained in valgus impacted fractures with a metaphyseal segment length of greater than 2 mm, and this was independent of Neer fracture type. Humeral head angulation had the greatest effect on final outcomes (P < 0.001), whereas metaphyseal segment length of less than 2 mm was predictive of developing avascular necrosis (P < 0.001).


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Fraturas do Ombro/cirurgia , Idoso , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Luxação do Ombro , Fraturas do Ombro/diagnóstico por imagem
5.
J Bone Joint Surg Am ; 91(7): 1689-97, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19571092

RESUMO

BACKGROUND: Optimal surgical management of three and four-part proximal humeral fractures in osteoporotic patients is controversial, with many advocating prosthetic replacement of the humeral head. Fixed-angle locked plates that maintain angular stability under load have been proposed as an alternative to hemiarthroplasty for the treatment of some osteoporotic fracture types. METHODS: The records of 122 consecutive patients who were fifty-five years of age or older and in whom a Neer three or four-part proximal humeral fracture had been treated surgically between January 2002 and November 2005 were studied retrospectively. After exclusions, thirty-eight patients treated with a locked-plate construct were compared with forty-eight patients who had undergone hemiarthroplasty. All patients had radiographic and clinical follow-up at a minimum of twenty-four months and an average of thirty-six months. Reduction and implant placement were evaluated radiographically. Clinical outcomes were measured with use of the Constant-Murley system. RESULTS: The mean Constant score (and standard deviation) at the time of final follow-up was significantly better in the locked-plate group (68.6 +/- 9.5 points) than in the hemiarthroplasty group (60.6 +/- 5.9 points) (p < 0.001). The Constant scores for the three-part fractures in the locked-plate and hemiarthroplasty groups were 71.6 and 60.4 points (p < 0.001), respectively, and the scores for the four-part fractures in those groups were 64.7 and 60.1 points (p = 0.19), respectively. Patients with an initial varus extension deformity in the locked-plate group had significantly worse outcomes than those with a valgus impacted pattern (Constant score, 63.8 compared with 74.6 points, respectively; p < 0.001). Complications in the group treated with locked-plate fixation included osteonecrosis in six patients, screw perforation of the humeral head in six patients, loss of fixation in four patients, and wound infection in three patients. Loss of fixation was seen only in patients with >20 degrees of initial varus angulation of the humeral head. Complications in the hemiarthroplasty group included nonunion of the tuberosity in seven patients and wound infection in three patients. CONCLUSIONS: In this series, open repair with use of a locked plate resulted in better outcome scores than did hemiarthroplasty in similar patients, especially in those with a three-part fracture, despite a higher overall complication rate. Open reduction and internal fixation of fractures with an initial varus extension pattern should be approached with caution.


Assuntos
Fraturas do Ombro/cirurgia , Idoso , Artroplastia/efeitos adversos , Placas Ósseas/efeitos adversos , Feminino , Fixação Interna de Fraturas , Humanos , Fixadores Internos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Radiografia , Fraturas do Ombro/complicações , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/patologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa