J Ultrasound Med ; 43(4): 629-641, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38168739

RESUMO

Over the last 20 years, scientific literature and interest on chest/lung ultrasound (LUS) have exponentially increased. Interpreting mixed-anatomical and artifactual-pictures determined the need of a proposal of a new nomenclature of artifacts and signs to simplify learning, spread, and implementation of this technique. The aim of this review is to collect and analyze different signs and artifacts reported in the history of chest ultrasound regarding normal lung, pleural pathologies, and lung consolidations. By reviewing the possible physical and anatomical interpretation of these artifacts and signs reported in the literature, this work aims to present the AdET (Accademia di Ecografia Toracica) proposal of nomenclature and to bring order between published studies.


Assuntos
Pneumopatias , Pulmão , Humanos , Pulmão/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Tórax , Ultrassonografia/métodos , Artefatos
2.
J Ultrasound Med ; 42(2): 279-292, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36301623

RESUMO

Although during the last few years the lung ultrasound (LUS) technique has progressed substantially, several artifacts, which are currently observed in clinical practice, still need a solid explanation of the physical phenomena involved in their origin. This is particularly true for vertical artifacts, conventionally known as B-lines, and for their use in clinical practice. A wider consensus and a deeper understanding of the nature of these artifactual phenomena will lead to a better classification and a shared nomenclature, and, ultimately, result in a more objective correlation between anatomo-pathological data and clinical scenarios. The objective of this review is to collect and document the different signs and artifacts described in the history of chest ultrasound, with a particular focus on vertical artifacts (B-lines) and sonographic interstitial syndrome (SIS). By reviewing the possible physical and anatomical interpretation of the signs and artifacts proposed in the literature, this work also aims to bring order to the available studies and to present the AdET (Accademia di Ecografia Toracica) viewpoint in terms of nomenclature and clinical approach to the SIS.


Assuntos
Artefatos , Pulmão , Humanos , Pulmão/diagnóstico por imagem , Síndrome , Ultrassonografia
3.
J Ultrasound Med ; 42(2): 309-344, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35993596

RESUMO

Following the innovations and new discoveries of the last 10 years in the field of lung ultrasound (LUS), a multidisciplinary panel of international LUS experts from six countries and from different fields (clinical and technical) reviewed and updated the original international consensus for point-of-care LUS, dated 2012. As a result, a total of 20 statements have been produced. Each statement is complemented by guidelines and future developments proposals. The statements are furthermore classified based on their nature as technical (5), clinical (11), educational (3), and safety (1) statements.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Consenso , Pulmão/diagnóstico por imagem , Testes Imediatos , Ultrassonografia
4.
J Ultrasound Med ; 41(10): 2637-2641, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34964991

RESUMO

With the emergence of the Covid-19 pandemic, pleuropulmonary ultrasound has become a very common tool in clinical practice, even in the pediatric field. Therefore, the clinicians' need to speak a common ultrasound language becomes increasingly necessary. The Italian scientific society AdET (Academy of Thoracic Ultrasound) has been carrying out the study and dissemination of pulmonary ultrasound in medical practice in Italy for years. With this article, the pediatric AdET group wants to propose a report model of pediatric pulmonary ultrasound as a useful tool in daily clinical practice to interpret the images and reach a diagnostic conclusion, aiming to share a standardized approach that may also support the sharing of research findings.


Assuntos
COVID-19 , Pediatria , Criança , Humanos , Pulmão/diagnóstico por imagem , Pandemias , Ultrassonografia
5.
J Ultrasound Med ; 40(10): 2235-2238, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33231895

RESUMO

Lung ultrasound (LUS) is currently being extensively used for the evaluation of patients affected by coronavirus disease 2019. In the past months, several imaging protocols have been proposed in the literature. However, how the different protocols would compare when applied to the same patients had not been investigated yet. To this end, in this multicenter study, we analyzed the outcomes of 4 different LUS imaging protocols, respectively based on 4, 8, 12, and 14 LUS acquisitions, on data from 88 patients. Results show how a 12-area acquisition system seems to be a good tradeoff between the acquisition time and accuracy.


Assuntos
COVID-19 , Humanos , Pulmão/diagnóstico por imagem , Estudos Multicêntricos como Assunto , SARS-CoV-2 , Ultrassonografia
6.
J Ultrasound Med ; 40(3): 521-528, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32815618

RESUMO

OBJECTIVES: The 2019 novel coronavirus (severe acute respiratory syndrome coronavirus 2) is causing cases of severe pneumonia. Lung ultrasound (LUS) could be a useful tool for physicians detecting a bilateral heterogeneous patchy distribution of pathologic findings in a symptomatic suggestive context. The aim of this study was to focus on the implications of limiting LUS examinations to specific regions of the chest. METHODS: Patients were evaluated with a standard sequence of LUS scans in 14 anatomic areas. A scoring system of LUS findings was reported, ranging from 0 to 3 (worst score, 3). The scores reported on anterior, lateral, and posterior landmarks were analyzed separately and compared with each other and with the global findings. RESULTS: Thirty-eight patients were enrolled. A higher prevalence of score 0 was observed in the anterior region (44.08%). On the contrary, 21.05% of posterior regions and 13.62% of lateral regions were evaluated as score 3, whereas only 5.92% of anterior regions were classified as score 3. Findings from chest computed tomography performed in 16 patients with coronavirus disease 2019 correlated with and matched the distribution of findings from LUS. CONCLUSIONS: To assess the quantity and severity of lung disease, a comprehensive LUS examination is recommended. Omitting areas of the chest misses involved lung.


Assuntos
COVID-19/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , SARS-CoV-2 , Índice de Gravidade de Doença
7.
J Ultrasound Med ; 40(8): 1627-1635, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33155689

RESUMO

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection can generate severe pneumonia associated with high mortality. A bedside lung ultrasound (LUS) examination has been shown to have a potential role in this setting. The purpose of this study was to evaluate the potential prognostic value of a new LUS protocol (evaluation of 14 anatomic landmarks, with graded scores of 0-3) in patients with SARS-CoV-2 pneumonia and the association of LUS patterns with clinical or laboratory findings. METHODS: A cohort of 52 consecutive patients with laboratory-confirmed SARS-CoV-2 underwent LUS examinations on admission in an internal medicine ward and before their discharge. A total LUS score as the sum of the scores at each explored area was computed. We investigated the association between the LUS score and clinical worsening, defined as a combination of high-flow oxygen support, intensive care unit admission, or 30-day mortality as the primary end point. RESULTS: Twenty (39%) patients showed a worse outcome during the observation period; the mean LUS scores ± SDs were 20.4 ± 8.5 and 29.2 ± 7.3 in patients without and with worsening, respectively (P < .001). In a multivariable analysis, adjusted for comorbidities (>2), age (>65 years), sex (male), and body mass index (≥25 kg/m2 ), the association between the LUS score and worsening (odds ratio, 1.17; 95% confidence interval, 1.05 to 1.29; P = .003) was confirmed, with good discrimination of the model (area under the receiver operating characteristic curve, 0.82). A median LUS score higher than 24 was associated with an almost 6-fold increase in the odds of worsening (odds ratio, 5.67; 95% confidence interval, 1.29 to 24.8; P = .021). CONCLUSIONS: Lung ultrasound can represent an effective tool for monitoring and stratifying the prognosis of patients with SARS-CoV-2 pulmonary involvement.


Assuntos
COVID-19 , Pneumonia , Idoso , Humanos , Pulmão/diagnóstico por imagem , Masculino , SARS-CoV-2 , Ultrassonografia
8.
J Acoust Soc Am ; 149(5): 3626, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34241100

RESUMO

In the current pandemic, lung ultrasound (LUS) played a useful role in evaluating patients affected by COVID-19. However, LUS remains limited to the visual inspection of ultrasound data, thus negatively affecting the reliability and reproducibility of the findings. Moreover, many different imaging protocols have been proposed, most of which lacked proper clinical validation. To address these problems, we were the first to propose a standardized imaging protocol and scoring system. Next, we developed the first deep learning (DL) algorithms capable of evaluating LUS videos providing, for each video-frame, the score as well as semantic segmentation. Moreover, we have analyzed the impact of different imaging protocols and demonstrated the prognostic value of our approach. In this work, we report on the level of agreement between the DL and LUS experts, when evaluating LUS data. The results show a percentage of agreement between DL and LUS experts of 85.96% in the stratification between patients at high risk of clinical worsening and patients at low risk. These encouraging results demonstrate the potential of DL models for the automatic scoring of LUS data, when applied to high quality data acquired accordingly to a standardized imaging protocol.


Assuntos
COVID-19 , Aprendizado Profundo , Humanos , Pulmão/diagnóstico por imagem , Reprodutibilidade dos Testes , SARS-CoV-2 , Ultrassonografia
9.
J Acoust Soc Am ; 150(6): 4118, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34972274

RESUMO

Ultrasound in point-of-care lung assessment is becoming increasingly relevant. This is further reinforced in the context of the COVID-19 pandemic, where rapid decisions on the lung state must be made for staging and monitoring purposes. The lung structural changes due to severe COVID-19 modify the way ultrasound propagates in the parenchyma. This is reflected by changes in the appearance of the lung ultrasound images. In abnormal lungs, vertical artifacts known as B-lines appear and can evolve into white lung patterns in the more severe cases. Currently, these artifacts are assessed by trained physicians, and the diagnosis is qualitative and operator dependent. In this article, an automatic segmentation method using a convolutional neural network is proposed to automatically stage the progression of the disease. 1863 B-mode images from 203 videos obtained from 14 asymptomatic individual,14 confirmed COVID-19 cases, and 4 suspected COVID-19 cases were used. Signs of lung damage, such as the presence and extent of B-lines and white lung areas, are manually segmented and scored from zero to three (most severe). These manually scored images are considered as ground truth. Different test-training strategies are evaluated in this study. The results shed light on the efficient approaches and common challenges associated with automatic segmentation methods.


Assuntos
COVID-19 , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Pandemias , SARS-CoV-2 , Tomografia Computadorizada por Raios X
10.
Am J Obstet Gynecol ; 223(1): 9-11, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32360111

RESUMO

Lung ultrasound examination has been demonstrated to be an accurate imaging method to detect pulmonary and pleural conditions. During pregnancy, there is a need for rapid assessment of the maternal lung in patients with suspected coronavirus disease 2019. We report our experience on lung ultrasound examination in the diagnosis of coronavirus disease 2019 pneumonia in a pregnant woman. Typical ultrasound features of this pulmonary pathology, including diffuse hyperechoic vertical artifacts with thickened pleural line and "white lung" with patchy distribution, were observed. We suggest point-of-care lung ultrasound examination as a diagnostic imaging tool in pregnant women with suspected coronavirus disease 2019.


Assuntos
Infecções por Coronavirus/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Complicações Infecciosas na Gravidez/diagnóstico por imagem , Betacoronavirus , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Feminino , Humanos , Pandemias , Gravidez , Complicações Infecciosas na Gravidez/virologia , Radiografia Torácica , SARS-CoV-2 , Ultrassonografia
11.
Respiration ; 99(2): 171-176, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31927551

RESUMO

INTRODUCTION: Thoracic ultrasound is accurate in the diagnosis of a wide range of respiratory diseases. Yet the extent of its use is unknown. Through a national survey, we aimed to explore the clinical use of thoracic ultrasound and the barriers to the diffusion of the technique in Italy. METHODS: Accademia di Ecografia Toracica (AdET) developed a self-administered survey which was sent by email to Italian pulmonologists via national scientific societies and networks. RESULTS: Of the 2010 physicians invited, 514 completed the survey (26% response rate). According to 99% of responders, thoracic ultrasound had a relevant clinical role. Seventy-nine percent of the responders used thoracic ultrasound at least once a month. The main settings were: 53% pulmonology ward, 15% outpatient clinic, 15% interventional pulmonology room, 10% internal medicine ward, 4% respiratory intensive care units, and 9% other. Thoracic ultrasound was primarily used: (1) with both diagnostic and interventional aims (72%), (2) as diagnostic imaging (17%), and (3) as guidance for interventional procedures (11%). The main clinical applications were: (1) diagnosis and management of pleural effusion, (2) pneumothorax, (3) pneumonia, (4) cardiac failure, and (5) acute dyspnea. Twenty-one percent of the responders do not use thoracic ultrasound. The main reported bar-riers were: (1) availability of an ultrasound system (52%), (2) lack of protected time and training (22%), and (3) use of the technique by other specialists (15%). CONCLUSION: Thoracic ultrasound is widely used by Italian pulmonologists and considered a clinically relevant tool. The availability of dedicated ultrasound systems seems to be a major limit of the use of the technique.


Assuntos
Derrame Pleural/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Pneumotórax/diagnóstico por imagem , Padrões de Prática Médica , Pneumologistas , Ultrassonografia/métodos , Adulto , Assistência Ambulatorial , Dor no Peito/diagnóstico por imagem , Diafragma/diagnóstico por imagem , Difusão de Inovações , Dispneia/diagnóstico por imagem , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Hospitalização , Humanos , Itália , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pleura/diagnóstico por imagem , Derrame Pleural/terapia , Embolia Pulmonar/diagnóstico por imagem , Inquéritos e Questionários , Parede Torácica/diagnóstico por imagem , Fatores de Tempo , Ultrassonografia/instrumentação
12.
J Ultrasound Med ; 39(12): 2483-2489, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32395910

RESUMO

Coronavirus disease 2019 (COVID-19) represents a very heterogeneous disease. Some aspects of COVID-19 pneumonia question the real nature of ground glass opacities and its consolidative lesions. It has been hypothesized that COVID-19 lung involvement could represent not only a viral effect but also an immune response induced by the infection, causing epithelial/endothelial lesions and coagulation disorders. We report 3 cases of COVID-19 pneumonia in which contrast-enhanced ultrasound was suggestive of consolidations with perfusion defects, at least in part caused by ischemic or necrotic changes and not only by inflammatory or atelectasis events.


Assuntos
COVID-19/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade
13.
J Ultrasound Med ; 39(12): 2379-2388, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32468627

RESUMO

OBJECTIVES: Lung ultrasound (LUS) has gained a primary role in the diagnosis and management of pleuropulmonary disorders in pediatric practice. However, normal and pathologic patterns are translated from adult studies and have never been specifically studied in children, particularly in infants. This was a prospective observational pilot study aiming to define the normal LUS pattern in healthy infants during the first 6 months of life. METHODS: We recruited healthy neonates at 7 to 10 days of life, and these were followed until the sixth month of life (times: 7-10 days, 1 month, 3 months, and 6 months). We excluded neonates with a gestational age before 33 weeks and neonates with cardiac or lung abnormalities or diseases, immune deficiencies, metabolic or genetic conditions, and acute or chronic respiratory diseases. A LUS evaluation was performed by a single certified pediatrician. The chest wall was examined in 18 areas, addressing A-lines, short and long B-lines, pleural abnormalities, and subpleural consolidations. RESULTS: Thirty-seven neonates were enrolled and followed until the sixth month of life, 27 (73%) of whom were born at term (≥37 weeks) and 10 (27%) of whom were born preterm (33-36 weeks). Most of the patients at 7 to 10 days showed multiple B-lines (long and short) with a progressive normalization toward a normal A pattern at 6 months (P < .00001; 95% confidence interval, 13.75-23.24). No infants showed subpleural consolidations or pleural abnormalities. CONCLUSIONS: This study has implications for the interpretation of LUS during the first 6 months of life. Most healthy infants show a diffuse pattern of vertical artifacts (B-lines), and the LUS pattern tends to be similar to the physiologic pattern (A-lines) after the sixth month of life. The only pathologic LUS findings were pleural irregularities and effusion and subpleural consolidations, which have never been described in healthy infants.


Assuntos
Pulmão , Pleura , Adulto , Criança , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia
14.
J Ultrasound Med ; 39(7): 1413-1419, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32227492

RESUMO

Growing evidence is showing the usefulness of lung ultrasound in patients with the 2019 new coronavirus disease (COVID-19). Severe acute respiratory syndrome coronavirus 2 has now spread in almost every country in the world. In this study, we share our experience and propose a standardized approach to optimize the use of lung ultrasound in patients with COVID-19. We focus on equipment, procedure, classification, and data sharing.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Ultrassonografia/normas , Pontos de Referência Anatômicos , Inteligência Artificial , COVID-19 , Bases de Dados Factuais , Previsões , Humanos , Processamento de Imagem Assistida por Computador , Internacionalidade , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , SARS-CoV-2
15.
J Acoust Soc Am ; 148(2): 998, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32872996

RESUMO

Lung ultrasound imaging is a fast-evolving field of application for ultrasound technologies. However, most diagnoses are currently performed with imaging protocols that assume a quasi-homogeneous speed of sound in the volume of interest. When applied to the lung, due to the presence of air, this assumption is unrealistic. Consequently, diagnoses are often based on imaging artifacts and thus qualitative and subjective. In this paper, we present an image formation protocol that is capable of capturing the frequency dependence of well-known artifacts (B-lines) and visualizing it in real time, ultimately providing a quantitative assessment of the signals received from the lung. Previous in vitro studies have shown the potential of B-lines native-frequency for the characterization of bubbly medium, but this paper presents the first results on clinical data. The image formation process has been designed to work on lung tissue, and ultrasound images generated with four orthogonal bands centered at 3, 4, 5 and 6 MHz can be acquired and displayed in real time. Results show that B-lines can be characterized on the basis of their native frequency in vivo and open the way toward real-time quantitative lung ultrasound imaging.


Assuntos
Artefatos , Pulmão , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Som , Ultrassonografia
19.
Gynecol Obstet Invest ; 82(4): 398-403, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27701165

RESUMO

BACKGROUND/AIMS: The normal lung ultrasound (US) pattern during a regular pregnancy has not been evaluated extensively in the current literature. Pregnancy-related changes in the respiratory tract affect maternal predisposition to several respiratory complications; consequently, it is important to differentiate between a physiologic pattern during pregnancy and a pathologic lung pattern, due to respiratory failure. The goal of our study was to assess the normal US lung pattern in women without known comorbidities in the last weeks of pregnancy. METHODS: We conducted a prospective cross-sectional observational pilot study. Chest wall was examined in 8 areas, 1 scan for each area with women in supine position. RESULTS: One hundred fifty parturients were enrolled during the 36th-38th gestational weeks. None of the participants showed pleural effusion, pneumothorax or lung consolidation. None presented an interstitial syndrome US pattern. One hundred thirteen participants out of 150 (75%) showed A-lines in all the regions. The remaining 25% showed 1 or 2 B-lines in at least 3 regions. Only 2 participants showed 2 positive regions also. CONCLUSIONS: We found that, in the majority of the women examined, the lung US pattern matches the physiological pattern in non-pregnant patients. Lung US assessment is a feasible and a helpful diagnostic tool during pregnancy.


Assuntos
Pulmão/diagnóstico por imagem , Complicações na Gravidez/diagnóstico por imagem , Trimestres da Gravidez/fisiologia , Insuficiência Respiratória/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Pulmão/fisiologia , Projetos Piloto , Gravidez , Estudos Prospectivos
20.
Toxicol Ind Health ; 33(6): 537-546, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28162043

RESUMO

OBJECTIVES: Exposure to asbestos fibers can lead to different lung diseases, such as pleural thickening and effusion, asbestosis, mesothelioma, and lung cancer. These diseases are expected to peak in the next few years. The aim of the study was to validate ultrasonography (US) as a diagnostic tool in the management of lung diseases in subjects with a history of occupational exposure to asbestos. METHODS: Fifty-nine retired male workers previously exposed to asbestos were enrolled in the study. Chest US was performed in all the subjects. The US operator was blinded to earlier performed computed tomography (CT) scan reports and images. The sonographic pathological findings were pleural thickening (with or without calcifications), peripheral lung consolidation, and focal sonographic interstitial syndrome and diffuse pneumogenic sonographic interstitial syndrome (pulmonary asbestosis). Significant US findings were recorded, stored, and subsequently compared with CT scans. RESULTS: With some patients falling into more than one category, on CT scan, pleural thickening was reported in 33 cases (56%, 26 with calcifications), focal interstitial peripheral alterations in 23 (39%), asbestosis in 6 (10%), and peripheral lung consolidation in 13 cases (22%). Comparing each pathological condition to CT scan reports, US findings had high levels of sensitivity, specificity, positive, and negative predictive values. US did not prove effective for the detection of central lung nodules or diaphragmatic pleural thickenings. Chest US was considered to be the best technique to detect minimal pleural effusions (six subjects, 10%). CONCLUSIONS: Chest US might be considered an additional tool to follow up subjects occupationally exposed to asbestos who have already undergone CT scan examination and whose pathology is detectable by US as well.


Assuntos
Amianto/toxicidade , Asbestose/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Exposição Ocupacional/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Estudos de Coortes , Humanos , Pulmão/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia