Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Respir Res ; 25(1): 179, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664685

RESUMO

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Assuntos
Impedância Elétrica , Tomografia , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia/métodos , Monitorização Fisiológica/métodos , Adulto , Respiração Artificial/métodos , Respiração , Idoso de 80 Anos ou mais , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia
2.
Curr Opin Crit Care ; 30(1): 28-34, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38062927

RESUMO

PURPOSE OF REVIEW: To summarize the key concepts, physiological rationale and clinical evidence for titrating positive end-expiratory pressure (PEEP) using transpulmonary pressure ( PL ) derived from esophageal manometry, and describe considerations to facilitate bedside implementation. RECENT FINDINGS: The goal of an esophageal pressure-based PEEP setting is to have sufficient PL at end-expiration to keep (part of) the lung open at the end of expiration. Although randomized studies (EPVent-1 and EPVent-2) have not yet proven a clinical benefit of this approach, a recent posthoc analysis of EPVent-2 revealed a potential benefit in patients with lower APACHE II score and when PEEP setting resulted in end-expiratory PL values close to 0 ±â€Š2 cmH 2 O instead of higher or more negative values. Technological advances have made esophageal pressure monitoring easier to implement at the bedside, but challenges regarding obtaining reliable measurements should be acknowledged. SUMMARY: Esophageal pressure monitoring has the potential to individualize the PEEP settings. Future studies are needed to evaluate the clinical benefit of such approach.


Assuntos
Pulmão , Respiração com Pressão Positiva , Humanos , Manometria , Esôfago/fisiologia
3.
Curr Opin Crit Care ; 28(1): 66-73, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34772836

RESUMO

PURPOSE OF REVIEW: To summarize the current knowledge about the application of advanced monitoring techniques in coronavirus disease 2019 (COVID-19). RECENT FINDINGS: Due to the heterogeneity between patients, management of COVID-19 requires daily monitoring of and/or aeration and inspiratory effort. Electrical impedance tomography can be used to optimize positive end-expiratory pressure, monitor the response to changes in treatment or body position and assess pulmonary perfusion and ventilation/perfusion matching. Lung ultrasound is more readily available and can be used to measure and monitor recruitment, provide an indication of diaphragm function and pulmonary perfusion disturbances. Esophageal pressure measurements enable the calculation of the transpulmonary pressure and inspiratory effort in order to prevent excessive stress on the lung. While esophageal pressure measurements are the golden standard in determining inspiratory effort, alternatives like P0.1, negative pressure swing during a single airway occlusion and change in central venous pressure are more readily available and capable of diagnosing extreme inspiratory efforts. SUMMARY: Although there is little data on the effectiveness of advanced monitoring techniques in COVID-19, regular monitoring should be a central part of the management of COVID-19-related acute respiratory distress syndrome (C-ARDS).


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Humanos , Respiração com Pressão Positiva , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/terapia , SARS-CoV-2
4.
Crit Care ; 26(1): 272, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36096837

RESUMO

RATIONALE: It is unknown how to titrate positive end-expiratory pressure (PEEP) in patients with COVID-19-related acute respiratory distress syndrome (ARDS). Guidelines recommend the one-size-fits-all PEEP-FiO2 table. In this retrospective cohort study, an electrical impedance tomography (EIT)-guided PEEP trial was used to titrate PEEP. OBJECTIVES: To compare baseline PEEP according to the high PEEP-FiO2 table and personalized PEEP following an EIT-guided PEEP trial. METHODS: We performed an EIT-guided decremental PEEP trial in patients with moderate-to-severe COVID-19-related ARDS upon intensive care unit admission. PEEP was set at the lowest PEEP above the intersection of curves representing relative alveolar overdistention and collapse. Baseline PEEP was compared with PEEP set according to EIT. We identified patients in whom the EIT-guided PEEP trial resulted in a decrease or increase in PEEP of ≥ 2 cmH2O. MEASUREMENTS AND MAIN RESULTS: We performed a PEEP trial in 75 patients. In 23 (31%) patients, PEEP was decreased ≥ 2 cmH2O, and in 24 (32%) patients, PEEP was increased ≥ 2 cmH2O. Patients in whom PEEP was decreased had improved respiratory mechanics and more overdistention in the non-dependent lung region at higher PEEP levels. These patients also had a lower BMI, longer time between onset of symptoms and intubation, and higher incidence of pulmonary embolism. Oxygenation improved in patients in whom PEEP was increased. CONCLUSIONS: An EIT-guided PEEP trial resulted in a relevant change in PEEP in 63% of patients. These results support the hypothesis that PEEP should be personalized in patients with ARDS.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , COVID-19/complicações , COVID-19/terapia , Impedância Elétrica , Humanos , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia , Estudos Retrospectivos
5.
Crit Care ; 24(1): 243, 2020 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-32448370

RESUMO

BACKGROUND: Heterogeneity of acute respiratory distress syndrome (ARDS) could be reduced by identification of biomarker-based phenotypes. The set of ARDS biomarkers to prospectively define these phenotypes remains to be established. OBJECTIVE: To provide an overview of the biomarkers that were multivariately associated with ARDS development or mortality. DATA SOURCES: We performed a systematic search in Embase, MEDLINE, Web of Science, Cochrane CENTRAL, and Google Scholar from inception until 6 March 2020. STUDY SELECTION: Studies assessing biomarkers for ARDS development in critically ill patients at risk for ARDS and mortality due to ARDS adjusted in multivariate analyses were included. DATA EXTRACTION AND SYNTHESIS: We included 35 studies for ARDS development (10,667 patients at risk for ARDS) and 53 for ARDS mortality (15,344 patients with ARDS). These studies were too heterogeneous to be used in a meta-analysis, as time until outcome and the variables used in the multivariate analyses varied widely between studies. After qualitative inspection, high plasma levels of angiopoeitin-2 and receptor for advanced glycation end products (RAGE) were associated with an increased risk of ARDS development. None of the biomarkers (plasma angiopoeitin-2, C-reactive protein, interleukin-8, RAGE, surfactant protein D, and Von Willebrand factor) was clearly associated with mortality. CONCLUSIONS: Biomarker data reporting and variables used in multivariate analyses differed greatly between studies. Angiopoeitin-2 and RAGE in plasma were positively associated with increased risk of ARDS development. None of the biomarkers independently predicted mortality. Therefore, we suggested to structurally investigate a combination of biomarkers and clinical parameters in order to find more homogeneous ARDS phenotypes. PROSPERO IDENTIFIER: PROSPERO, CRD42017078957.


Assuntos
Biomarcadores/análise , Síndrome do Desconforto Respiratório/mortalidade , Angiopoietina-2/análise , Angiopoietina-2/sangue , Antígenos de Neoplasias/análise , Antígenos de Neoplasias/sangue , Humanos , Proteínas Quinases Ativadas por Mitógeno/análise , Proteínas Quinases Ativadas por Mitógeno/sangue , Análise Multivariada , Síndrome do Desconforto Respiratório/fisiopatologia
6.
Purinergic Signal ; 14(3): 215-221, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29752619

RESUMO

Recent research suggested an important role for pulmonary extracellular adenosine triphosphate (ATP) in the development of ventilation-induced lung injury. This injury is induced by mechanical deformation of alveolar epithelial cells, which in turn release ATP to the extracellular space. Measuring extracellular ATP in exhaled breath condensate (EBC) may be a non-invasive biomarker for alveolar deformation. Here, we study the feasibility of bedside ATP measurement in EBC. We measured ATP levels in EBC in ten subjects before and after an exercise test, which increases respiratory parameters and alveolar deformation. EBC lactate concentrations were measured as a dilution marker. We found a significant increase in ATP levels in EBC (before 73 RLU [IQR 50-209] versus after 112 RLU [IQR 86-203]; p value 0.047), and the EBC ATP-to-EBC lactate ratio increased as well (p value 0.037). We present evidence that bedside measurement of ATP in EBC is feasible and that ATP levels in EBC increase after exercise. Future research should measure ATP levels in EBC during mechanical ventilation as a potential biomarker for alveolar deformation.


Assuntos
Trifosfato de Adenosina/análise , Testes Respiratórios/métodos , Testes Imediatos , Lesão Pulmonar Induzida por Ventilação Mecânica/diagnóstico , Adulto , Biomarcadores/análise , Testes Respiratórios/instrumentação , Exercício Físico/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Int J Mol Sci ; 19(4)2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29652806

RESUMO

Stretching the alveolar epithelial type I (AT I) cells controls the intercellular signaling for the exocytosis of surfactant by the AT II cells through the extracellular release of adenosine triphosphate (ATP) (purinergic signaling). Extracellular ATP is cleared by extracellular ATPases, maintaining its homeostasis and enabling the lung to adapt the exocytosis of surfactant to the demand. Vigorous deformation of the AT I cells by high mechanical power ventilation causes a massive release of extracellular ATP beyond the clearance capacity of the extracellular ATPases. When extracellular ATP reaches levels >100 μM, the ATP receptors of the AT II cells become desensitized and surfactant impairment is initiated. The resulting alteration in viscoelastic properties and in alveolar opening and collapse time-constants leads to alveolar collapse and the redistribution of inspired air from the alveoli to the alveolar ducts, which become pathologically dilated. The collapsed alveoli connected to these dilated alveolar ducts are subject to a massive strain, exacerbating the ATP release. After reaching concentrations >300 μM extracellular ATP acts as a danger-associated molecular pattern, causing capillary leakage, alveolar space edema, and further deactivation of surfactant by serum proteins. Decreasing the tidal volume to 6 mL/kg or less at this stage cannot prevent further lung injury.


Assuntos
Trifosfato de Adenosina/metabolismo , Lesão Pulmonar/etiologia , Respiração Artificial/efeitos adversos , Animais , Humanos , Lesão Pulmonar/metabolismo , Lesão Pulmonar/patologia , Proteínas Associadas a Surfactantes Pulmonares/metabolismo , Receptores Purinérgicos P2X4/metabolismo , Receptores Purinérgicos P2Y2/metabolismo , Transdução de Sinais
11.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697210

RESUMO

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Assuntos
Artefatos , Impedância Elétrica , Processamento de Sinais Assistido por Computador , Tomografia , Humanos , Tomografia/métodos , Razão Sinal-Ruído , Adulto , Análise de Ondaletas , Sistema Cardiovascular , Recém-Nascido
12.
Intensive Care Med Exp ; 12(1): 30, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502268

RESUMO

BACKGROUND: Mechanical power (MP) is the energy delivered by the ventilator to the respiratory system and combines factors related to the development of ventilator-induced lung injury (VILI). Flow-controlled ventilation (FCV) is a new ventilation mode using a constant low flow during both inspiration and expiration, which is hypothesized to lower the MP and to improve ventilation homogeneity. Data demonstrating these effects are scarce, since previous studies comparing FCV with conventional controlled ventilation modes in ICU patients suffer from important methodological concerns. OBJECTIVES: This study aims to assess the difference in MP between FCV and pressure-controlled ventilation (PCV). Secondary aims were to explore the effect of FCV in terms of minute volume, ventilation distribution and homogeneity, and gas exchange. METHODS: This is a physiological study in post-cardiothoracic surgery patients requiring mechanical ventilation in the ICU. During PCV at baseline and 90 min of FCV, intratracheal pressure, airway flow and electrical impedance tomography (EIT) were measured continuously, and hemodynamics and venous and arterial blood gases were obtained repeatedly. Pressure-volume loops were constructed for the calculation of the MP. RESULTS: In 10 patients, optimized FCV versus PCV resulted in a lower MP (7.7 vs. 11.0 J/min; p = 0.004). Although FCV did not increase overall ventilation homogeneity, it did lead to an improved ventilation of the dependent lung regions. A stable gas exchange at lower minute volumes was obtained. CONCLUSIONS: FCV resulted in a lower MP and improved ventilation of the dependent lung regions in post-cardiothoracic surgery patients on the ICU. Trial registration Clinicaltrials.gov identifier: NCT05644418. Registered 1 December 2022, retrospectively registered.

13.
Respir Med Case Rep ; 25: 225-227, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30245971

RESUMO

Spontaneous breathing efforts during mechanical ventilation can lead to patient self-inflicted lung injury (P-SILI). In order to prevent P-SILI, patients are generally heavily sedated and receive muscle relaxation, resulting in a slower weaning process. We present a case in which we applied partial neuromuscular blockage in order to prevent P-SILI while allowing spontaneous breathing but with limited efforts during assist mechanical ventilation.

14.
Respir Med Case Rep ; 20: 141-144, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28224077

RESUMO

Preserving spontaneous breathing during mechanical ventilation prevents muscle atrophy of the diaphragm, but may lead to ventilator induced lung injury (VILI). We present a case in which monitoring of trans-pulmonary pressure and ventilation distribution using Electrical Impedance Tomography (EIT) provided essential information for preventing VILI.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa