1.
J Korean Med Sci ; 37(38): e280, 2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36193637

RESUMO

BACKGROUND: It is essential to understand the mechanism of the various causes of laser fiber damage and an ideal method of reducing endoscope damage induced by laser emission in multiple sites. This study classified the different patterns of laser fiber degradation according to laser settings and analyzed the role of cavitation bubbles to find a desirable way of minimizing endoscope damage. METHODS: A total of 118 laser fibers were analyzed after 1-,3-, and 5-min laser emission to artificial stones under the settings of 1 J-10 Hz, 1 J-20 Hz, 1 J-30 Hz, and 2 J-10 Hz. Every 3 cm from the fiber tip was marked and examined with a digital microscope and a high-speed camera. The images of the fibers and the movement of cavitation bubbles were taken with a distance of 1 to 5 mm from the gel. RESULTS: Seven types of fiber damage (charring, limited and extensive peeled-off, bumpy, whitish plaque, crack, and break-off) coincided during laser emission. Damages rapidly increased with emission time > 3 minutes regardless of the laser settings. The damaged lengths covered 5 mm on average, and the fibers at 5-min emission were significantly shorter than others. The fiber durability of 1J-10Hz setting was better than other settings after 3-min laser emission. Backward movement of the cavitation bubbles was found at the 1-mm distance from the gel, and the damaged lengths were longer than the diameters of the cavitation bubbles because of their proximal movement. CONCLUSION: The damage patterns of the laser fiber tips were classified into seven types. The heat damage around the surface of the laser fiber can be increased according to the high-energy or high-frequency laser setting, a short distance to the stone, a short distance from the tips of flexible ureteroscopes, no cutting laser fiber procedures, and the inappropriate use of irrigation fluid or laser fiber jacket.


Assuntos
Terapia a Laser , Humanos , Lasers
2.
Ultrasonography ; 42(2): 249-258, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36935599

RESUMO

PURPOSE: High-contrast tissue characterization of thermal ablation has been desired to evaluate therapeutic outcomes accurately. This paper presents a photoacoustic (PA) characterization of thermal tissue ablation in the visible spectrum, in which higher light absorbance can produce spectral contrast starker than in the near-infrared range. METHODS: Ex vivo experiments were performed to measure visible PA spectra (480-700 nm) from fresh porcine liver tissues that received a thermal dose in a range of cumulative equivalent minutes at 43°C (CEM43). The local hemoglobin lobe area between 510-600 nm and wholespectral area under the curve were evaluated to represent the transition of hemoglobin into methemoglobin (MetHb) in the target tissue. RESULTS: The thermal process below an estimated therapeutic CEM43 threshold (80-340 minutes) presented a progressive elevation of the PA spectrum and an eventual loss of local hemoglobin peaks in the visible spectrum, closer to the MetHb spectrum. Interestingly, an excessive CEM43 produced a substantial drop in the PA spectrum. In the spectral analysis, the visible spectrum yielded 13.9-34.1 times higher PA sensitivity and 1.42 times higher contrast change than at a near-infrared wavelength. CONCLUSION: This novel method of PA tissue characterization in the visible spectrum could be a potential modality to evaluate various thermal therapeutic modalities at high-contrast resolution.

3.
Investig Clin Urol ; 63(4): 385-393, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35670003

RESUMO

Shock waves are commonly used in the field of urology. They have two phases, positive and negative, and the bubble generation is roughly classified into acoustic cavitation (AC) and laser-induced cavitation (LIC). We evaluated the occurrence of cavitation, its duration, the area of interest, and the maximal diameter of the cavitation bubbles. Changes in AC occurred at 0.2 ms with the highest number of bubbles and disappeared at 0.6 ms. The bubble size was 2 mm in diameter. Changes in LIC bubbles were observed in three pulse modes. The short pulse showed an initial bubble starting at 0.005 ms, which reached its largest size at 0.4 to 0.6 ms. The long pulse showed an initial bubble starting at 0.005 ms, which reached its largest size at 0.4 ms with the formation of an additional lagena-shaped bubble at 0.6 ms. The distance mode of MOSES showed two signal peaks with the formation of two consecutive bubbles at 0.2 and 0.6 ms. The main difference in the laser beams between the long-pulse and the MOSES modes was the continuity and the peak power of the laser beam. The diameters parallel to the laser direction were 6.8, 8.6, and 9.7 mm at 1, 2, and 3 J, respectively, in the short pulse. While the cavitation bubbles rupture, ejectile force occurs in numerous directions, transmitting high enough energy to break the targets. Cavitation bubbles should be regarded as energy and the mediators of energy for stone fragmentation and tissue destruction.


Assuntos
Urologia , Humanos , Lasers