Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Radiology ; 312(2): e233234, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39162632

RESUMO

Background CT-derived fractional flow reserve (CT-FFR) and dynamic CT myocardial perfusion imaging enhance the specificity of coronary CT angiography (CCTA) for ruling out coronary artery disease (CAD). However, evidence on comparative diagnostic value remains scarce. Purpose To compare the diagnostic accuracy of CCTA plus CT-FFR, CCTA plus CT perfusion, and sequential CCTA plus CT-FFR and CT perfusion for detecting hemodynamically relevant CAD with that of invasive angiography. Materials and Methods This secondary analysis of a prospective study included patients with chest pain referred for invasive coronary angiography at nine centers from July 2016 to September 2019. CCTA and CT perfusion were performed with third-generation dual-source CT scanners. CT-FFR was assessed on-site. Independent core laboratories analyzed CCTA alone, CCTA plus CT perfusion, CCTA plus CT-FFR, and a sequential approach involving CCTA plus CT-FFR and CT perfusion for the presence of hemodynamically relevant stenosis. Invasive coronary angiography with invasive fractional flow reserve was the reference standard. Diagnostic accuracy metrics and the area under the receiver operating characteristic curve (AUC) were compared with the Sign test and DeLong test. Results Of the 105 participants (mean age, 64 years ± 8 [SD]; 68 male), 49 (47%) had hemodynamically relevant stenoses at invasive coronary angiography. CCTA plus CT-FFR and CCTA plus CT perfusion showed no evidence of a difference for participant-based sensitivities (90% vs 90%, P > .99), specificities (77% vs 79%, P > .99) and vessel-based AUCs (0.84 [95% CI: 0.77, 0.91] vs 0.83 [95% CI: 0.75, 0.91], P = .90). Both had higher participant-based specificity than CCTA alone (54%, both P < .001) without evidence of a difference in sensitivity between CCTA (94%) and CCTA plus CT perfusion (P = .50) or CCTA plus CT-FFR (P = .63). The sequential approach combining CCTA plus CT-FFR with CT perfusion achieved higher participant-based specificity than CCTA plus CT-FFR (88% vs 77%, P = .03) without evidence of a difference in participant-based sensitivity (88% vs 90%, P > .99) and vessel-based AUC (0.85 [95% CI: 0.77, 0.93], P = .78). Compared with CCTA plus CT perfusion, the sequential approach showed no evidence of a difference in participant-based sensitivity (P > .99), specificity (P = .06), or vessel-based AUC (P = .54). Conclusion There was no evidence of a difference in diagnostic accuracy between CCTA plus CT-FFR and CCTA plus CT perfusion for detecting hemodynamically relevant CAD. A sequential approach combining CCTA plus CT-FFR with CT perfusion led to improved participant-based specificity with no evidence of a difference in sensitivity compared with CCTA plus CT-FFR. ClinicalTrials.gov registration no.: NCT02810795 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Idoso , Imagem de Perfusão do Miocárdio/métodos , Hemodinâmica/fisiologia , Sensibilidade e Especificidade
2.
Eur Radiol ; 34(7): 4273-4283, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38177617

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA). METHODS: Consecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 × 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 ("excellent") to 5 ("non-diagnostic"), and assessed all coronary stents for the presence of in-stent stenosis (≥ 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference. RESULTS: A total of 44 coronary stents in 18 participants (mean age, 83 years ± 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen's kappa value of 0.72. CONCLUSIONS: UHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: Ultra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis. KEY POINTS: • CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution. • Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography. • Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Sensibilidade e Especificidade , Stents , Humanos , Feminino , Masculino , Angiografia Coronária/métodos , Idoso de 80 Anos ou mais , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Idoso , Fótons
3.
Radiology ; 307(5): e223305, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338354

RESUMO

Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Radiologe ; 60(12): 1131-1141, 2020 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-33185699

RESUMO

BACKGROUND: Coronary CT angiography (cCTA) has a high negative predictive value for ruling out significant coronary stenoses. However, it is limited in determining hemodynamic significance of a stenosis and hence to prove the indication for therapy. OBJECTIVES: When and how is cCTA used according to current guidelines? Which functional CT techniques are available to test for hemodynamic significance of coronary stenoses? MATERIALS AND METHODS: The value of cCTA is explained on the basis of current guidelines by the European Society of Cardiology (ESC) for the diagnosis of chronic coronary syndromes. Functional CT techniques which test for hemodynamic significance of coronary stenoses are myocardial CT-perfusion (CT­P) and CT-based fractional flow reserve (CT-FFR). RESULTS: The new ESC guidelines classify cCTA as a class 1 recommendation for diagnosing coronary artery disease in symptomatic patients with low clinical likelihood. If clinical likelihood is high or an at least moderate stenosis is detected with cCTA, noninvasive functional (stress) imaging is preferred. There is a large body of evidence for CT­P and CT-FFR as functional tests. CONCLUSION: In the current guidelines, cCTA is highly recommended for the diagnosis of coronary artery disease. The functional CT techniques CT­P and CT-FFR have shown high diagnostic accuracy for myocardial ischemia of coronary stenoses in many clinical studies. However, these methods are not part of current guidelines yet and clinical adoption is still low.


Assuntos
Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico , Constrição Patológica , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
5.
Eur J Nucl Med Mol Imaging ; 43(5): 889-897, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26592938

RESUMO

PURPOSE: Multiparametric magnetic resonance imaging (mpMRI) is widely used in radiation treatment planning of primary prostate cancer (PCA). Focal dose escalation to the dominant intraprostatic lesions (DIPL) may lead to improved PCA control. Prostate-specific membrane antigen (PSMA) is overexpressed in most PCAs. (68)Ga-labelled PSMA inhibitors have demonstrated promising results in detection of PCA with PET/CT. The aim of this study was to compare (68)Ga-PSMA PET/CT with MRI for gross tumour volume (GTV) definition in primary PCA. METHODS: This retrospective study included 22 patients with primary PCA analysed after (68)Ga-PSMA PET/CT and mpMRI. GTVs were delineated on MR images by two radiologists (GTV-MRIrad) and two radiation oncologists separately. Both volumes were merged leading to GTV-MRIint. GTVs based on PET/CT were delineated by two nuclear medicine physicians in consensus (GTV-PET). Laterality (left, right, and left and right prostate lobes) on mpMRI, PET/CT and pathological analysis after biopsy were assessed. RESULTS: Mean GTV-MRIrad, GTV-MRIint and GTV-PET were 5.92, 3.83 and 11.41 cm(3), respectively. GTV-PET was significant larger then GTV-MRIint (p = 0.003). The MRI GTVs GTV-MRIrad and GTV-MRIint showed, respectively, 40 % and 57 % overlap with GTV-PET. GTV-MRIrad and GTV-MRIint included the SUVmax of GTV-PET in 12 and 11 patients (54.6 % and 50 %), respectively. In nine patients (47 %), laterality on mpMRI, PET/CT and histopathology after biopsy was similar. CONCLUSION: Ga-PSMA PET/CT and mpMRI provided concordant results for delineation of the DIPL in 47 % of patients (40 % - 54 % of lesions). GTV-PET was significantly larger than GTV-MRIint. (68)Ga-PSMA PET/CT may have a role in radiation treatment planning for focal radiation to the DIPL. Exact correlation of PET and MRI images with histopathology is needed.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Oligopeptídeos , Compostos Organometálicos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Carga Tumoral
6.
J Clin Med ; 13(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38673658

RESUMO

Background: The goal of our study is to evaluate a method to quantify aortic valve calcification (AVC) in contrast-enhanced computed tomography for patients with suspected severe aortic stenosis pre-interventionally. Methods: A total of sixty-five patients with aortic stenosis underwent both a native and a contrast-enhanced computed tomography (CECT) scan of the aortic valve (45 in the training cohort and 20 in the validation cohort) using a standardized protocol. Aortic valve calcification was semi-automatically quantified via the Agatston score method for the native scans and was used as a reference. For contrast-enhanced computed tomography, a calcium threshold of the Hounsfield units of the aorta plus four times the standard deviation was used. Results: For the quantification of aortic valve calcification in contrast-enhanced computed tomography, a conversion formula (691 + 1.83 x AVCCECT) was derived via a linear regression model in the training cohort. The validation in the second cohort showed high agreement for this conversion formula with no significant proportional bias (Bland-Altman, p = 0.055) and with an intraclass correlation coefficient in the validation cohort of 0.915 (confidence interval 95% 0.786-0.966) p < 0.001. Conclusions: Calcium scoring in patients with aortic valve stenosis can be performed using contrast-enhanced computed tomography with high validity. Using a conversion factor led to an excellent agreement, thereby obviating an additional native computed tomography scan. This might contribute to a decrease in radiation exposure.

7.
Eur J Radiol ; 173: 111360, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342061

RESUMO

PURPOSE: To determine the diagnostic accuracy of volumetric interpolated breath-hold examination sequences with fat suppression in Dixon technique (VIBE-Dixon) for cardiac thrombus detection. METHOD: From our clinical database, we retrospectively identified consecutive patients between 2014 and 2022 who had definite diagnosis or exclusion of cardiac thrombus confirmed by an independent adjudication committee, serving as the reference standard. All patients received 2D-Cine plus 2D-Late-Gadolinium-Enhancement (Cine + LGE) and VIBE-Dixon sequences. Two blinded readers assessed all images for the presence of cardiac thrombus. The diagnostic accuracy of Cine + LGE and VIBE-Dixon was determined and compared. RESULTS: Among 141 MRI studies (116 male, mean age: 61 years) mean image examination time was 28.8 ± 3.1 s for VIBE-Dixon and 23.3 ± 2.5 min for Cine + LGE. Cardiac thrombus was present in 49 patients (prevalence: 35 %). For both readers sensitivity for thrombus detection was significantly higher in VIBE-Dixon compared with Cine + LGE (Reader 1: 96 % vs.73 %, Reader 2: 96 % vs. 78 %, p < 0.01 for both readers), whereas specificity did not differ significantly (Reader 1: 96 % vs. 98 %, Reader 2: 92 % vs. 93 %, p > 0.1). Overall diagnostic accuracy of VIBE-Dixon was higher than for Cine + LGE (95 % vs. 89 %, p = 0.02) and was non-inferior to the reference standard (Delta ≤ 5 % with probability > 95 %). CONCLUSIONS: Biplanar VIBE-Dixon sequences, acquired within a few seconds, provided a very high diagnostic accuracy for cardiac thrombus detection. They could be used as stand-alone sequences to rapidly screen for cardiac thrombus in patients not amenable to lengthy acquisition times.


Assuntos
Meios de Contraste , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Gadolínio , Estudos Retrospectivos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Trombose/diagnóstico por imagem , Aumento da Imagem/métodos
8.
Diagn Interv Radiol ; 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39463047

RESUMO

PURPOSE: The study aimed to assess the feasibility and image quality of dual-source photon-counting detector computed tomography (PCD-CT) in evaluating small-sized coronary artery stents with respect to different acquisition modes in a phantom model. METHODS: Utilizing a phantom setup mimicking the average patient's water-equivalent diameter, we examined six distinct coronary stents inflated in a silicon tube, with stent sizes ranging from 2.0 to 3.5 mm, applying four different CT acquisition modes of a dual-source PCD-CT scanner: "high-pitch," "sequential," "spiral" (each with collimation of 144 × 0.4 mm and full spectral information), and "ultra-high-resolution (UHR)" (collimation of 120 × 0.2 mm and no spectral information). Image quality and diagnostic confidence were assessed using subjective measures, including a 4-point visual grading scale (4 = excellent; 1 = non-diagnostic) utilized by two independent radiologists, and objective measures, including the full width at half maximum (FWHM). RESULTS: A total of 24 scans were acquired, and all were included in the analysis. Among all CT acquisition modes, the highest image quality was obtained for the UHR mode [median score: 4 (interquartile range (IQR): 3.67-4.00)] (P = 0.0015, with 37.5% rated as "excellent"), followed by the sequential mode [median score: 3.5 (IQR: 2.84-4.00)], P = 0.0326 and the spiral mode [median score: 3.0 (IQR: 2.53-3.47), P > 0.05]. The lowest image quality was observed for the high-pitch mode [median score: 2 (IQR: 1- 3), P = 0.028]. Similarly, diagnostic confidence for evaluating stent patency was highest for UHR and lowest for high-pitch (P < 0.001, respectively). Measurement of stent dimensions was accurate for all acquisition modes, with the UHR mode showing highest robustness (FWHM for sequential: 0.926 ± 0.061 vs. high-pitch: 0.990 ± 0.083 vs. spiral: 0.962 ± 0.085 vs. UHR: 0.941 ± 0.036, P = non-significant, respectively). CONCLUSION: Assessing small-sized coronary stents using PCD-CT technology is feasible. The UHR mode offers superior image quality and diagnostic confidence, while all modes show consistent and accurate measurements. CLINICAL SIGNIFICANCE: These findings highlight the potential of PCD-CT technology, particularly the UHR mode, to enhance non-invasive coronary stent evaluation. Confirmatory research is necessary to influence the guidelines, which recommend cardiac CT only for stents of 3 mm or larger.

9.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
10.
Clin Res Cardiol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39230714

RESUMO

AIMS: To quantify greyzone fibrosis (GZF) in patients after acute myocardial infarction (MI) and to evaluate its correlation with MI-free survival and improvements in left ventricular ejection fraction (LVEF) compared with the established risk factors high-sensitivity cardiac troponin T (hs-cTnT) and Late Gadolinium Enhancement (LGE). METHODS AND RESULTS: The study involved 176 patients who experienced acute MI and underwent cardiac magnetic resonance (CMR) prior to hospital discharge, followed by a second CMR on average six months later. LGE was quantified in both examinations, a separate analysis of the GZF was conducted only in the follow-up CMR after resolution of the initial infarct edema. LVEF was measured in both CMR. hs-cTnT levels were assessed at hospital admission, as well as 8, 16, 24, 48 and 72 h after coronary intervention. Telephone follow-ups were conducted annually for up to 8 years. LGE measurements showed better correlation with MI-free survival (Harrell's C of 0.711 of LGE mass) compared to GZF (0.579 of GZF mass). Additionally, hs-cTnT outperformed GZF (Harrell's C of 0.645). As an univariable predictor for MI-free survival, only hs-cTnT reached significance (p < 0.05). With regard to improvements in ejection fraction, both hs-cTnT and LGE measurements showed acceptable correlation with improvement in ejection fraction (p < 0.05), while GZF measurements showed no correlation (p > 0.5). CONCLUSIONS: In CMR, the assessment of GZF demonstrated inferior p correlation compared to hs-cTnT and LGE in patients after acute MI with respect to the endpoint of MI-free survival. Furthermore, GZF showed no correlation with the improvement of LVEF.

11.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360986

RESUMO

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Substituição da Valva Aórtica Transcateter/instrumentação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Exposição à Radiação , Tomada de Decisão Clínica , Fótons , Tomografia Computadorizada Multidetectores
12.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
13.
Thorac Cardiovasc Surg Rep ; 12(1): e7-e9, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36851994

RESUMO

Coronary artery fistula (CAF), complicated by the aneurysmal formation of the coronary sinus (CS), is a very rare form of CAF. Here we report a case of a 60- year-old woman with a giant aneurysm of the CS resulting from the right coronary artery (RCA) fistula. The patient was highly symptomatic with dyspnea due to compression of cardiac chambers. CS reconstruction was performed using a pericardial patch after directly closing the fistula from the RCA to the CS.

14.
Radiol Case Rep ; 18(6): 2180-2182, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37101893

RESUMO

The incidence of vascular and especially aortic pathologies is increasing, which leads to a higher frequency of vascular imaging. As renal pathologies also become more frequent, especially in an aging population, the need for effective preventative scan protocols with reduced contrast material is pressing. An 81-year-old female patient in our institution required a follow-up imaging of an incidental, asymptomatic abdominal aortic aneurysm. Although the patient was suffering from incipient chronic renal failure, a contrast-enhanced aortoiliac computed tomography angiography was performed using a first generation, clinical photon-counting detector computed tomography scanner. This scanner allows a modified scan protocol with a significant reduction of contrast agent while preserving diagnostic confidence. Technically, this is feasible by dual-source spectral image acquisition and dynamic monochromatic reconstruction near the K-edge of Iodine without loss of temporal or spatial resolution. The results are promising, allowing vascular imaging with significantly less risk of renal damage. In this regard, further research into optimal scan-protocols and post-processing is needed.

15.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370957

RESUMO

BACKGROUND: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. METHODS: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. RESULTS: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. CONCLUSIONS: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

16.
J Thorac Cardiovasc Surg ; 165(3): 958-965.e4, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34001355

RESUMO

OBJECTIVE: To evaluate the long-term incidence and outcome of aortic interventions for medically managed uncomplicated thoracic aortic dissections. METHODS: Between January 2012 and December 2018, 91 patients were discharged home with an uncomplicated, medically treated aortic dissection (involving the descending aorta with or without aortic arch involvement, no ascending involvement). After a median period of 4 (first quartile: 2, third quartile: 11) months, 30 patients (33%) required an aortic intervention. Patient characteristics, radiographic, treatment, and follow-up data were compared for patients with and without aortic interventions. A competing risk regression model was analyzed to identify independent predictors of aortic intervention and to predict the risk for intervention. RESULTS: Patients who underwent aortic interventions had significantly larger thoracic (P = .041) and abdominal (P = .015) aortic diameters, the dissection was significantly longer (P = .035), there were more communications between both lumina (P = .040), and the first communication was significantly closer to the left subclavian artery (P = .049). A descending thoracic aortic diameter exceeding 45 mm was predictive for an aortic intervention (P = .001; subdistribution hazard ratio: 3.51). The risk for aortic intervention was 27% ± 10% and 36% ± 11% after 1 and 3 years, respectively. Fourteen patients (47%) underwent thoracic endovascular aortic repair, 11 patients (37%) thoracic endovascular aortic repair and left carotid to subclavian bypass, 3 patients (10%) total arch replacement with the frozen elephant trunk technique, and 2 patients (7%) thoracoabdominal aortic replacement. We observed no in-hospital mortality. CONCLUSIONS: The need for secondary aortic interventions in patients with initially medically managed, uncomplicated descending aortic dissections is substantial. The full spectrum of aortic treatment options (endovascular, hybrid, conventional open surgical) is required in these patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção da Aorta Torácica , Procedimentos Endovasculares , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
17.
Eur Heart J Cardiovasc Imaging ; 24(12): 1672-1681, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37409579

RESUMO

AIMS: To determine the conditions under which early hypoattenuated leaflet thickening (HALT) after transcatheter aortic valve implantation (TAVI) becomes haemodynamically relevant. METHODS AND RESULTS: The study included 100 patients (age: 81.5 ± 5.5 years; female 63%), thereof 50 patients with HALT. After anonymization and randomization, blinded readers measured maximum thrombus thickness per prosthesis (MT_pr) and movement restriction (MR_pr) on electrocardiogram (ECG)-gated whole heart cycle computed tomography angiography. These measurements were compared with echocardiographic mean pressure gradient (mPG), its increase from baseline (ΔmPG), and Doppler velocity index (DVI). Haemodynamic valve deterioration (HVD) was defined as mPG > 20 mmHg. Age, body mass index, valve type, valve size, left ventricular ejection fraction, and atrial fibrillation were considered as influencing factors. Multiple regression analysis revealed that only valve size (P = 0.001) and MT_pr (P = 0.02) had a significant influence on mPG. In an interaction model, valve size moderated the effect of MT_pr on mPG significantly (P = 0.004). Sub-group analysis stratified by valve sizes showed a strong correlation between MT_pr and echocardiographic parameters for 23 mm valves (mPG: r = 0.57, ΔmPG: r = 0.68, DVI: r = 0.55, each with P < 0.001), but neither for 26 nor 29 mm valves (r < 0.2, P > 0.2 for all correlations). Six of seven prostheses with HVD had a 23 mm valve diameter, while one had 29 mm (P = 0.02). CONCLUSION: Early HALT rarely causes significant mPG increase. Our study shows that valve size is a key factor influencing the haemodynamic impact of HALT. In small valve sizes, mPG is more likely to increase. Our study is the first to offer in vivo evidence supporting previous in vitro findings on this topic.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Volume Sistólico , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Masculino
18.
J Clin Med ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959289

RESUMO

Background: We aimed to evaluate the feasibility of a non-contrast time-of-flight magnetic resonance angiography (TOF-MRA) protocol for the pre-procedural access route assessment of transcatheter aortic valve implantation (TAVI) in comparison with contrast-enhanced cardiac dual-source computed tomography angiography (CTA). Methods and Results: In total, 51 consecutive patients (mean age: 82.69 ± 5.69 years) who had undergone a pre-TAVI cardiac CTA received TOF-MRA for a pre-procedural access route assessment. The MRA image quality was rated as very good (median of 5 [IQR 4-5] on a five-point Likert scale), with only four examinations rated as non-diagnostic. The TOF-MRA systematically underestimated the minimal effective vessel diameter in comparison with CTA (for the effective vessel diameter in mm, the right common iliac artery (CIA)/external iliac artery (EIA)/common femoral artery (CFA) MRA vs. CTA was 8.04 ± 1.46 vs. 8.37 ± 1.54 (p < 0.0001) and the left CIA/EIA/CFA MRA vs. CTA was 8.07 ± 1.32 vs. 8.28 ± 1.34 (p < 0.0001)). The absolute difference between the MRA and CTA was small (for the Bland-Altman analyses in mm, the right CIA/EIA/CFA was -0.36 ± 0.77 and the left CIA/EIA/CFA was -0.25 ± 0.61). The overall correlation between the MRA and CTA measurements was very good (with a Pearson correlation coefficient of 0.87 (p < 0.0001) for the right CIA/EIA/CFA and a Pearson correlation coefficient of 0.9 (p < 0.0001) for the left CIA/EIA/CFA). The feasibility agreement between the MRA and CTA for transfemoral access was good (the right CIA/EIA/CFA agreement was 97.9% and the left CIA/EIA/CFA agreement was 95.7%, Kohen's kappa: 0.477 (p = 0.001)). Conclusions: The TOF-MRA protocol was feasible for the assessment of the access route in an all-comer pre-TAVI population. This protocol might be a reliable technique for patients at an increased risk of contrast-induced nephropathy.

19.
Rofo ; 195(4): 293-296, 2023 04.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-36796410

RESUMO

BACKGROUND: Structured reporting allows a high grade of standardization and thus a safe and unequivocal report communication. In the past years, the radiological societies have started several initiatives to base radiological reports on structured reporting rather than free text reporting. METHODS: Upon invitation of the working group for Cardiovascular Imaging of the German Society of Radiology, in 2018 an interdisciplinary group of Radiologists, Cardiologists, Pediatric Cardiologists and Cardiothoracic surgeons -all experts on the field of cardiovascular MR and CT imaging- met for interdisciplinary consensus meetings at the University Hospital Cologne. The aim of these meetings was to develop and consent templates for structured reporting in cardiac MR and CT of various cardiovascular diseases. RESULTS: Two templates for structured reporting of CMR in ischemia imaging and vitality imaging and two templates for structured reporting of CT imaging for planning Transcatheter Aortic Valve Implantation (TAVI; pre-TAVI-CT) and coronary CT were discussed, consented and transferred to a HTML 5/IHR MRRT compatible format. The templates were made available for free use on the website www.befundung.drg.de. CONCLUSION: This paper suggests consented templates in German language for the structured reporting of cross-sectional CMR imaging of ischemia and vitality as well as reporting of CT imaging pre-TAVI and coronary CT. The implementation of these templates is aimed at providing a constant level of high reporting quality and increasing the efficiency of report generation as well as a clinically based communication of imaging results. KEY POINTS: · Structured reporting offers a constant level of high reporting quality and increases the efficiency of report generation as well as a clinically based communication of imaging results.. · For the first time templates in German language for the structured reporting of CMR imaging of ischemia and vitality and CT imaging pre-TAVI and coronary CT are reported.. · These templates will be made available on the website www.befundung.drg.de and can be commented via strukturierte-befundung@drg.de.. ZITIERWEISE: · Soschynski M, Bunck AC, Beer M et al. Structured Reporting in Cross-Sectional Imaging of the Heart: Reporting Templates for CMR Imaging of Ischemia and Myocardial Viability and for Cardiac CT Imaging of Coronary Heart Disease and TAVI Planning. Fortschr Röntgenstr 2023; 195: 293 - 296.


Assuntos
Estenose da Valva Aórtica , Doença das Coronárias , Substituição da Valva Aórtica Transcateter , Criança , Humanos , Coração , Tomografia Computadorizada por Raios X/métodos , Miocárdio , Isquemia , Valva Aórtica
20.
Radiologie (Heidelb) ; 62(11): 947-953, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-36006439

RESUMO

CLINICAL/METHODICAL ISSUE: Cardiac diseases are the leading cause of death. Many diseases can be specifically treated once a valid diagnosis is established. Cardiac magnetic resonance imaging (MRI) plays a central role in the workup of many cardiac pathologies. However, image acquisition as well as interpretation and related secondary image evaluation are time-consuming and complex. STANDARD RADIOLOGICAL METHODS: Cardiac MRI is becoming increasingly established in international guidelines for the evaluation of cardiac function and differential diagnosis of a wide variety of cardiac diseases. METHODOLOGICAL INNOVATIONS: Cardiac MRI has limited reproducibility due to the acquisition technique and interpretation of findings with complex secondary measurements. Artificial intelligence techniques and radiomics offer the potential to improve the acquisition, interpretation, and reproducibility of cardiac MRI. PERFORMANCE: Research suggests that artificial intelligence and radiomic analysis can improve cardiac MRI in terms of image acquisition and also diagnostic and prognostic value. Furthermore, the implementation of artificial intelligence and radiomics may result in the identification of new biomarkers. ACHIEVEMENTS AND PRACTICAL RECOMMENDATIONS: The implementation of artificial intelligence in cardiac MRI has great potential. However, the current level of evidence is still limited in some aspects; in particular there are too few prospective and large multicenter studies available. As a result, the algorithms developed are often not sufficiently validated scientifically and are not yet applied in clinical routine.


Assuntos
Inteligência Artificial , Cardiopatias , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Cardiopatias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa