Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
World J Surg Oncol ; 20(1): 215, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35751053

RESUMO

BACKGROUND: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is an established diagnostic procedure for solid pancreatic mass. However, the diagnostic yield between fine-needle aspiration (FNA) and fine-needle biopsy (FNB) remains unclear. We aimed to evaluate and compare the diagnostic yields between FNA and FNB using conventional FNA and Franseen needles of the same size 22-gauge needle, in patients with solid pancreatic mass who underwent EUS-TA without rapid onsite cytopathology evaluation (ROSE). METHODS: All cases of EUS-TA by FNA or FNB for solid pancreatic mass between January 2017 and October 2020 in a single-centre university hospital were retrospectively reviewed. All procedures were performed without an onsite cytologist. Before the endoscopist finished the procedure, macroscopic onsite evaluation (MOSE) was confirmed. The diagnostic yield and the average number of needle passes between FNB and FNA were then compared. RESULTS: A total of 151 patients (FNA, n = 77; FNB, n = 74) with solid pancreatic mass detected by cross-sectional imaging underwent EUS-TA. The mean age was 62.3 ± 12.8 years, with 88 (58.3%) males. Age, sex, mass location, tumour size and disease stage from imaging were not significantly different between the two groups. The diagnostic performance was higher in EUS-FNB (94.6%) than in EUS-FNA (89.6%). The mean number of needle passes was clearly fewer in FNB than in FNA (2.8 vs. 3.8, p < 0.001). The total procedure time was shorter in FNB (34.7 min) than in FNA (41 min). The adverse event rate between FNB and FNA was not significantly different. CONCLUSIONS: The diagnostic yield of solid pancreatic mass was higher in FNB using the Franseen needle than in FNA using the conventional FNA needle in a centre where ROSE is unavailable, without serious adverse event. In addition, FNB had fewer needle passes and shorter total procedure time.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas , Idoso , Endossonografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Avaliação Rápida no Local , Estudos Retrospectivos
2.
Gastrointest Endosc ; 86(6): 1059-1065, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28392365

RESUMO

BACKGROUND AND AIMS: ERCP with stone removal is the standard treatment for common bile duct stones (CBDSs). Radiation exposure is a risk to the endoscopist and patient. EUS-guided ERCP without fluoroscopy (EGEWF) in patients with CBDSs is feasible, but the efficacy and safety compared with ERCP is unknown. We aimed to compare the efficacy and safety of EGEWF with ERCP in CBDS removal. METHODS: A prospective randomized study was done in 114 patients with CBDSs who met inclusion criteria. These patients were equally randomized into the EGEWF and ERCP groups. In the EGEWF group, ERCP was performed by cannulation without fluoroscopy. Balloon sweeping was done after sphincterotomy to clear the stones until the number of stones matched the number detected by EUS and the stone clearance (SC) was confirmed by cholangiography. In the ERCP group, ERCP was performed in the standard manner. The cannulation rates, SC rates, total procedure and fluoroscopic times, and adverse event rates were analyzed. RESULTS: After exclusion of 3 patients, 55 were in the EGEWF group and 56 in the ERCP group. Demographic data, laboratory data, stone characteristics, CBD diameter, and number of patients with periampullary diverticulum were not different between the 2 groups. The cannulation success rates in the EGEWF (96.35%) and ERCP (100%) groups were similar (P = .243). The SC rate in the EGEWF group (85.5%) was inferior to the ERCP group (100%) (P = .002). The SC rate based on the number of stones retrieved that matched the number by EUS was correct in 94%. More than 2 stones may increase the failure rate of SC in EGEWF. The adverse event rates and the total procedure times were not different between the groups. CONCLUSIONS: EGEWF was inferior to ERCP in terms of SC; however, no radiation exposure is beneficial for selected patients. (Clinical trial registration number: NCT02870686.).


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/diagnóstico por imagem , Cálculos Biliares/cirurgia , Adulto , Idoso , Cateterismo , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Endossonografia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Esfinterotomia Endoscópica , Resultado do Tratamento , Ultrassonografia de Intervenção
3.
BMC Gastroenterol ; 16: 4, 2016 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-26762316

RESUMO

BACKGROUND: The association of minimal change esophagitis (MCE) with GERD is controversial. i-Scan endoscopy (SE) provides high resolution and modulation of images that may improve minimal change lesion (MCL) detection. We aimed to assess the efficacy of SE in detecting MCL in dyspeptic patients with GERD compared with patients without GERD by GerdQ or by endoscopy with 24-h pH monitoring (PHM) and in normal volunteers. METHODS: This is a cohort study conducted at a tertiary center. All dyspeptic patients were prospectively recruited. All patients completed a validated Thai version of GerdQ and then underwent endoscopy. Forty normal volunteers as a control group were recruited for endoscopy. The distal esophagus was examined by high definition endoscopy and SE sequentially. All had PHM done. GERD was diagnosed by Los Angeles classification A-D and/or by a positive PHM. MCE was diagnosed when MCL or combination of MCL was present. RESULTS: Of 174 patients, 144 completed the study protocol. After the exclusion of 6 patients, 138 remained for analysis. Overlapping GERD symptoms were found in 44.2 % and 26.8 % had confirmed GERD. Group A was comprised of 61 patients with a positive GerdQ and 77 patients in group B had a negative GerdQ. Twenty-four in group A, 28 in group B and 7 in the control group had MCE that was not significantly different. MCE in GERD was significantly higher (51.45 %) than in non-GERD (32.7 %) (p = 0.047) and in the control group (20.58 %) (p = 0.007). The sensitivity, specificity, positive predictive value, and negative predictive value of SE were 51.35 %, 67.33 %, 36.54 % and 79.06 %, respectively. CONCLUSION: In dyspeptic patients, SE detected more MCE in GERD than in non-GERD patients and in the control group. TRIAL REGISTRATION: ClinicalTrials.gov number NCT01742377.


Assuntos
Dispepsia/complicações , Esofagite/diagnóstico , Esofagoscopia/métodos , Refluxo Gastroesofágico/complicações , Adulto , Idoso , Estudos de Casos e Controles , Dispepsia/fisiopatologia , Monitoramento do pH Esofágico/métodos , Esofagite/etiologia , Esofagite/fisiopatologia , Esôfago/química , Esôfago/fisiopatologia , Feminino , Refluxo Gastroesofágico/fisiopatologia , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Inquéritos e Questionários , Adulto Jovem
4.
Diagnostics (Basel) ; 14(2)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38248049

RESUMO

BACKGROUND: The treatment of chronic pancreatitis (CP) and symptomatic pancreatic duct (PD) calculi often involves techniques like endoscopic retrograde cholangiopancreatography (ERCP), extracorporeal shock wave lithotripsy (ESWL), or a combination of both. However, identifying predictive factors for the successful removal of these calculi remains variable. This study aimed to determine the factors predicting successful ESWL and endoscopic removal in CP and PD calculi patients. METHODS: We examined data from CP patients who underwent complete PD calculi removal via ESWL combined with ERCP between July 2012 and 2022, and assessed baseline characteristics, imaging findings, and treatment details. Patients were categorized into early- and late-endoscopic complete removal groups (EER and LER groups, respectively). RESULTS: Of the 27 patients analyzed, 74.1% were male with an average age of 44 ± 9.6 years. EER was achieved in 74% of the patients. Patients in the EER group exhibited smaller PD calculi diameter (8.5 vs. 19 mm, p = 0.012) and lower calculus density (964.6 vs. 1313.3 HU, p = 0.041) compared to the LER group. Notably, PD stricture and the rate of PD stent insertion were not different between the groups. A calculus density threshold of 1300 HU on non-contrast CT demonstrated 71% sensitivity and 80% specificity in predicting EER. CONCLUSIONS: Smaller and low-density PD calculi may serve as predictors for successful EER, potentially aiding in the management of CP patients with PD calculi.

5.
Clin Endosc ; 55(5): 645-654, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36071005

RESUMO

BACKGROUND/AIMS: Narrow Band Imaging (NBI) International Colorectal Endoscopic (NICE) and Workgroup Serrated Polyps and Polyposis (WASP) classifications were developed for optical diagnosis of neoplastic and sessile serrated polyps, respectively. Near-focus NBI with NICE combined with WASP criteria for optical diagnosis of colonic polyps has not yet been evaluated. We aimed to compare the accuracy of near-focus NBI (group A) with normal-focus NBI (group B) in real-time optical diagnosis of colorectal polyps using combined NICE and WASP criteria. METHODS: Among 362 patients, 118 with 227 polyps were recruited. Groups A and B included 62 patients with 130 polyps (three lost polyps) and 56 patients with 106 polyps (six lost polyps), respectively. Optical diagnoses were compared with pathological reports. RESULTS: The accuracy of optical diagnosis of neoplastic polyps in groups A and B was not significantly different (76% vs. 71%, p=0.52). WASP criteria provided all false positive diagnoses of sessile polyps as serrated polyps in 31 (16.2%) patients. CONCLUSION: Near-focus NBI was not superior to normal-focus NBI in optical diagnostics of neoplastic polyps using NICE criteria. In our study, WASP classification yielded all false positives in the diagnosis of sessile serrated adenomas/polyps. Routine real-life optical diagnosis of polyps is still unadvisable.

6.
J Neurogastroenterol Motil ; 25(1): 15-26, 2019 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-30504528

RESUMO

The management of dyspepsia in limited-resource areas has not been established. In 2017, key opinion leaders throughout Thailand gathered to review and evaluate the current clinical evidence regarding dyspepsia and to develop consensus statements, rationales, levels of evidence, and grades of recommendation for dyspepsia management in daily clinical practice based on the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach. This guideline is mainly focused on the following 4 topics: (1) evaluation of patients with dyspepsia, (2) management, (3) special issues (overlapping gastroesophageal reflux disease/irritable bowel syndrome and non-steroidal anti-inflammatory drug/aspirin use), and (4) long-term follow-up and management to provide guidance for physicians in Thailand and other limited-resource areas managing such patients.

7.
J Med Case Rep ; 12(1): 33, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-29444709

RESUMO

BACKGROUND: Mucinous cystic neoplasm of the liver with extrahepatic growth is a rare benign epithelial neoplasm of the biliary system that presents with a mass effect or is incidentally found on imaging. The tumor affects mostly the common hepatic duct, which is difficult to diagnose preoperatively by radiology, endoscopy, or cystic fluid analysis. Endoscopic ultrasound is a noninvasive tool for the evaluation of features of a cystic lesion and the extent of disease. Optimal treatment is complete tumor resection. CASE PRESENTATION: A 27-year-old Thai woman was referred to our hospital for investigation and treatment of clinical symptoms of obstructive jaundice and ascending cholangitis, as well as an unknown cause of obstruction. Multiple investigations were performed, including endoscopic retrograde cholangiography and magnetic resonance imaging. Endoscopic ultrasound showed a multiloculated cystic lesion with internal septations without communication to the bile duct, which helped to support a diagnosis of mucinous cystic neoplasm. Eventually, the pathological diagnosis made was mucinous cystic neoplasm of the bile duct. A follow-up clinical examination with imaging at 6 months revealed that the patient was asymptomatic and without recurrence. CONCLUSIONS: We report a rare case of a patient with a large mucinous cystic neoplasm of the liver with extrahepatic growth causing biliary obstruction, which was diagnosed on the basis of endoscopic ultrasound features. Following definitive diagnosis, treatment with complete surgical resection using a multidisciplinary approach was successful.


Assuntos
Colangite/complicações , Endossonografia/métodos , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Colangiopancreatografia Retrógrada Endoscópica/métodos , Diagnóstico Diferencial , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos
8.
Gut Pathog ; 9: 65, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29177012

RESUMO

BACKGROUND: Many bacteria and archaea possess a defense system called clustered regularly interspaced short palindromic repeats (CRISPR) associated proteins (CRISPR-Cas system) against invaders such as phages or plasmids. This system has not been demonstrated in Helicobacter pylori. The numbers of spacer in CRISPR array differ among bacterial strains and can be used as a genetic marker for bacterial typing. RESULTS: A total of 36 H. pylori isolates were collected from patients in three hospitals located in the central (PBH) and southern (SKH) regions of Thailand. It is of interest that CRISPR-like sequences of this bacterium were detected in vlpC encoded for VacA-like protein C. Virulence genes were investigated and the most pathogenic genotype (cagA vacA s1m1) was detected in 17 out of 29 (58.6%) isolates from PBH and 5 out of 7 (71.4%) from SKH. vapD gene was identified in each one isolate from PBH and SKH. CRISPR-like sequences and virulence genes of 20 isolates of H. pylori obtained in this study were analyzed and CRISPR-virulence typing was constructed and compared to profiles obtained by the random amplification of polymorphic DNA (RAPD) technique. The discriminatory power (DI) of CRISPR-virulence typing was not different from RAPD typing. CONCLUSION: CRISPR-virulence typing in H. pylori is easy and reliable for epidemiology and can be used for inter-laboratory interpretation.

10.
Clin Transl Gastroenterol ; 8(8): e113, 2017 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-28796231

RESUMO

OBJECTIVES: The Asia-Pacific Colorectal Screening (APCS) scoring system was developed to identify high-risk subjects for advanced neoplasia. However, the appropriate fecal immunochemical test (FIT) cutoff for high-risk population may be different from that of average-risk population. We aimed to evaluate the FIT performance at different cutoffs in high-risk subjects undergoing colorectal cancer (CRC) screening. METHODS: We prospectively enrolled asymptomatic subjects aged 50-75 years. Using the APCS score, subjects were stratified into either the average-risk or high-risk groups. All subjects were tested with one-time quantitative FIT and underwent colonoscopy. We compared the FIT performance for advanced neoplasia between two groups using different cutoffs (5 (FIT5), 10 (FIT10), 20 (FIT20), 30 (FIT30), and 40 (FIT40) µg Hb/g feces). RESULTS: Overall, 1,713 subjects were recruited, and 1,222 (71.3%) and 491 (28.7%) were classified as average-risk and high-risk, respectively. Advanced neoplasia was detected in 90 (7.4%) of the average-risk subjects and 65 (13.2%) of the high-risk subjects. In the high-risk group, by decreasing the cutoff from FIT40 to FIT5, the sensitivity increased by 33.8 percentage points with decreased specificity by 11 percentage points. In the average-risk group, the sensitivity increased by 20 percentage points with decreased specificity by 9.6 percentage points. At the lowest cutoff (FIT5), the number of needed colonoscopies to find one advanced neoplasia was 2.8 and 6.1 for the high-risk and average-risk groups, respectively. CONCLUSIONS: Using an appropriate FIT cutoff for CRC screening in high-risk subjects could improve CRC screening performance and reduce the unnecessary colonoscopies. To maintain high sensitivity and specificity for advanced neoplasia, the optimal cutoff FIT in the high-risk subjects should be lower than that in the average-risk subjects.

11.
Asian Pac J Cancer Prev ; 18(2): 405-412, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28345822

RESUMO

Background: Selecting the cut-off point for the fecal immunochemical test (FIT) for colorectal cancer (CRC) screening programs is of prime importance. The balance between the test performance for detecting advanced neoplasia and the available colonoscopy resources should be considered. We aimed to identify the optimal cut-off of FIT for advanced neoplasia in order to minimize colonoscopy burden. Methods: We conducted a multi-center study in 6 hospitals from diverse regions of Thailand. Asymptomatic participants, aged 50-75 years, were tested with one-time quantitative FIT (OC-SENSOR, Eiken Chemical Co.,Ltd., Tokyo, Japan) and all participants underwent colonoscopy. We assessed test performance in detecting advanced neoplasia (advanced adenoma and CRC) and measured the burden of colonoscopy with different cut-offs [25 (FIT25), 50 (FIT50), 100 (FIT100), 150 (FIT150), and 200 (FIT200)ng/ml]. Results: Among 1,479 participants, advanced neoplasia and CRC were found in 137 (9.3%) and 14 (0.9%), respectively. From FIT25 to FIT200, the positivity rate decreased from 18% to 4.9%. For advanced neoplasia, an increased cut-off decreased sensitivity from 42.3% to 16.8% but increased specificity from 84.2% to 96.3%. The increased cut-off increased the positive predictive value (PPV) from 21.5% to 31.5%. However, all cut-off points provided a high negative predictive value (NPV) (>90%). For CRC, the miss rate for FIT25 to FIT 150 was the same (n=3, 21%), whereas that with FIT200 increased to 35% (n=5). Conclusions: In a country with limited-colonoscopy resources, using FIT150 may be preferred because it offers both high PPV and NPV for advanced neoplasia detection. It could also decrease colonoscopy workload, while maintaining a CRC miss rate similar to those with lower cut-offs.

12.
Diagn Ther Endosc ; 2016: 9371878, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27293368

RESUMO

Aim. To study the efficacy and other treatment outcomes of Ovesco clip closure of iatrogenic perforation. Methods. Retrospective study from 3 tertiary-care hospitals in Thailand. Patients with iatrogenic perforation who underwent immediate endoscopic closure by Ovesco clip were included. Patients' demographic data, perforation size, number of Ovesco clips used, fasting day, length of hospital stay, success rates, and complication rate were recorded. Technical success was defined as closure achievement during endoscopic procedure and clinical success was defined as the patient can be discharged without the need of additional surgical or radiological intervention. Results. There were 6 iatrogenic perforations in 2 male and 4 female patients. The median age was 59 years (range 39-78 years). The locations of perforation were 5 duodenal walls and 1 rectosigmoid junction. The median perforation size was 13 mm (range 10-40 mm). The technical success was 100% and the clinical success was 83.3%. The success rates per locations were 100% in colon and 80% in duodenum, respectively. The median fasting time was 5 days (range 1-10 days) and the median length of hospital stay was 10 days (range 2-22 days). There was no mortality in any. Conclusion. Ovesco clip seems to be an effective and safe tool for a closure of iatrogenic perforation.

13.
Endosc Ultrasound ; 5(3): 165-72, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27386473

RESUMO

BACKGROUND AND OBJECTIVES: Endoscopic ultrasound (EUS) achieves results comparable to endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of common bile duct (CBD) stone, but studies from the western have shown EUS to be less expensive in patients with intermediate risk for CBD stones. The aim of this study was to compare the costs of EUS and ERCP in the diagnosis of CBD stones in a developing country. MATERIALS AND METHODS: A prospective study was done with 141 patients with suspected CBD stones, categorized as having high or intermediate risk for CBD stone. All underwent EUS, and the high-risk patients had ERCP after the EUS. For intermediate-risk patients, an ERCP was done at the discretion of the attending physician. The CBD stone was confirmed by ERCP in patients who underwent both EUS and ERCP. Patients who received EUS only were followed up every 3 months for 1 year. The false negative rate in patients with EUS and ERCP was estimated in the clinical follow-up. RESULT: One hundred and forty-one patients (141: 83 females, 58 males) with a mean age ± standard deviation (SD) of 55.71 ±18.68 years were recruited. Ninety-four (94) patients underwent both EUS and ERCP. ERCP confirmed the diagnosis in 83 of 85 patients (97.6%) with CBD stone detected by EUS. Forty-seven (47) patients with a negative EUS and no ERCP done were symptom-free during the follow-up. The overall sensitivity, specificity, positive predictive value, and negative predictive value of EUS were 97.6%, 80%, 97.6%, and 80% respectively. An EUS-based strategy for high-risk patients was 15% more expensive than an ERCP-based strategy, but the EUS-based strategy reduced the cost to 37.78% less than the ERCP-based strategy in intermediate-risk patients. The EUS-based strategy was cost-saving when the CBD stone prevalence was less than 52.5%. CONCLUSION: EUS is safer and less costly than ERCP for CBD stone diagnosis in patients with intermediate risk.

14.
Asian Pac J Cancer Prev ; 17(5): 2351-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27268597

RESUMO

Management of Helicobacter pylori infection is an important aspect of many upper gastrointestinal tract diseases, such as chronic gastritis, peptic ulcer disease, gastric cancer and mucosa-associated lymphoid tissue (MALT) lymphoma. The Thailand Consensus on H. pylori treatment 2015 consisted of 22 national experts who took active roles, discussed all important clinical information and investigated clinical aspects in four workshops, focuising on: (1) Diagnosis (2) Treatment (3) Follow-up after eradication and (4) H. pylori infection and special conditions. Experts were invited to participate on the basis of their expertise and contribution to H. pylori works and/or consensus methodology. The results of each workshop were taken to a final consensus vote by all experts. Recommendations were developed from the best evidence and availability to guide clinicians in management of this specific infection associated with variety of clinical outcomes.


Assuntos
Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori/isolamento & purificação , Consenso , Infecções por Helicobacter/microbiologia , Humanos , Tailândia
15.
Gastroenterol Res Pract ; 2012: 680753, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22654900

RESUMO

Background and Aim. EUS-guided intervention (EGI) for biliary therapy has been increasingly used in recent years. This report aims to describe the spectrum and experience of EUS-guided interventions in biliary diseases in a single-tertiary center. Methods. All patients with EGI were analyzed retrospectively by retrieving data from a prospectively stored endoscopic database between January 2006 and September 2010. Results. There were 31 cases with EGIs (17 female, 14 male) with a mean age ± SD of 58.03 ± 16.89 years. The majority of cases (17/31; 55%) were ampullary or pancreatic cancers with obstructive jaundice. The major indications for EGI were obstructive jaundice (n = 16) and cholangitis (n = 9). The EGIs were technically successful in 24 of the 31 cases (77%). The success rate for the first 3 years was 8 of 13 procedures (61.5%) as compared to that of the last 2 years (16/18 procedures (89%); P = 0.072). Twenty-three of the 24 cases (96%) with technical success for stent placement also had clinical success in terms of symptom improvement. The complications were major in 4 (13%) and minor in 7 (23%) patients. Conclusion. The EUS-guided drainage for biliary obstruction, acute cholecystitis, bile leak, and biloma was an attractive alternative and should be handled in expert centers.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa