1.
BMC Musculoskelet Disord ; 25(1): 449, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844899

RESUMO

BACKGROUND: Patient-specific aiming devices (PSAD) may improve precision and accuracy of glenoid component positioning in total shoulder arthroplasty, especially in degenerative glenoids. The aim of this study was to compare precision and accuracy of guide wire positioning into different glenoid models using a PSAD versus a standard guide. METHODS: Three experienced shoulder surgeons inserted 2.5 mm K-wires into polyurethane cast glenoid models of type Walch A, B and C (in total 180 models). Every surgeon placed guide wires into 10 glenoids of each type with a standard guide by DePuy Synthes in group (I) and with a PSAD in group (II). Deviation from planned version, inclination and entry point was measured, as well as investigation of a possible learning curve. RESULTS: Maximal deviation in version in B- and C-glenoids in (I) was 20.3° versus 4.8° in (II) (p < 0.001) and in inclination was 20.0° in (I) versus 3.7° in (II) (p < 0.001). For B-glenoid, more than 50% of the guide wires in (I) had a version deviation between 11.9° and 20.3° compared to ≤ 2.2° in (II) (p < 0.001). 50% of B- and C-glenoids in (I) showed a median inclination deviation of 4.6° (0.0°-20.0°; p < 0.001) versus 1.8° (0.0°-4.0°; p < 0.001) in (II). Deviation from the entry point was always less than 5.0 mm when using PSAD compared to a maximum of 7.7 mm with the standard guide and was most pronounced in type C (p < 0.001). CONCLUSION: PSAD enhance precision and accuracy of guide wire placement particularly for deformed B and C type glenoids compared to a standard guide in vitro. There was no learning curve for PSAD. However, findings of this study cannot be directly translated to the clinical reality and require further corroboration.


Assuntos
Artroplastia do Ombro , Curva de Aprendizado , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/instrumentação , Fios Ortopédicos , Cavidade Glenoide/cirurgia , Modelos Anatômicos , Articulação do Ombro/cirurgia
2.
J Anat ; 238(3): 669-678, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33084063

RESUMO

Cortical bone and its microstructure are crucial for bone strength, especially at the long bone diaphysis. However, it is still not well-defined how imaging procedures can be used as predictive tools for mechanical bone properties. This study evaluated the capability of several high-resolution imaging techniques to capture cortical bone morphology and assessed the correlation with the bone's mechanical properties. The microstructural properties (cortical thickness [Ct.Th], porosity [Ct.Po], area [Ct.Ar]) of 11 female tibial diaphysis (40-90 years) were evaluated by dual-energy X-ray absorptiometry (DXA), high-resolution peripheral-quantitative-computed-tomography (HR-pQCT), micro-CT (µCT) and histomorphometry. Stiffness and maximal torque to failure were determined by mechanical testing. T-Scores determined by DXA ranged from 0.6 to -5.6 and a lower T-Score was associated with a decrease in Ct.Th (p ≤ 0.001) while the Ct.Po (p ≤ 0.007) increased, and this relationship was independent of the imaging method. With decreasing T-Score, histology showed an increase in Ct.Po from the endosteal to the periosteal side (p = 0.001) and an exponential increase in the ratio of osteons at rest to those after remodelling. However, compared to histomorphometry, HR-pQCT and µCT underestimated Ct.Po and Ct.Th. A lower T-Score was also associated with significantly reduced stiffness (p = 0.031) and maximal torque (p = 0.006). Improving the accuracy of Ct.Po and Ct.Th did not improve prediction of the mechanical properties, which was most closely related to geometry (Ct.Ar). The ex-vivo evaluation of mechanical properties correlated with all imaging modalities, with Ct.Th and Ct.Po highly correlated with the T-Score of the tibial diaphysis. Cortical microstructural changes were underestimated with the lower resolution of HR-pQCT and µCT compared to the histological 'gold standard'. The increased accuracy did not result in an improved prediction for local bone strength in this study, which however might be related to the limited number of specimens and thus needs to be evaluated in a larger collective.


Assuntos
Osso Cortical/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Diáfises/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Microtomografia por Raio-X
3.
Calcif Tissue Int ; 101(3): 271-279, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28432379

RESUMO

Fractures of the proximal humerus are highly related to age and osteoporotic bone remodeling. Previous studies have highlighted the cortex as a major side of the bone loss, but the microstructural changes of the humerus have not been evaluated entirely. Sixty-four (n = 64) humeri of a representative collective (18-100 years) were scanned with high-resolution peripheral quantitative computed tomography (82 µm). Bone mineral density (BMD), trabecular bone volume fraction (Tb.BV/TV), cortical thickness (Ct.Th), and cortical porosity (Ct.Po) were determined with respect to four age groups. The BMD (r = -0.42), Ct.Th (r = 0.57), and Tb.BV/TV (r = 0.68) showed an age group-related decrease, while the Ct.Po increased (r = -0.55). The oldest group (80-100 years) revealed an extensively higher Ct.Po of +87% compared to the youngest group (18-44 years), while the Ct.Th and Tb.BV/TV were significantly lower by -35 and -49% (p < 0.05). The main cortical bone loss occurred after 65 years with the Ct.Th (-34%) and Tb.BV/TV (-40%) being clearly lower and the Ct.Po (+93%) clearly higher compared to the youngest group. In summary, osteoporosis leads to an age-related higher Ct.Po and reduced Ct.Th at the humeral cortex of the surgical neck. The bone loss of the cortex predominantly occurs around the age of 65 years and is very likely to reduce the mechanical strength and highly increases the fracture risk.


Assuntos
Envelhecimento/patologia , Densidade Óssea , Osso Cortical/patologia , Úmero/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Osso Cortical/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Porosidade , Tomografia Computadorizada por Raios X , Adulto Jovem
4.
Arch Orthop Trauma Surg ; 136(9): 1331-1335, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27450194

RESUMO

INTRODUCTION: Primary press fit and secondary osteointegration is a precondition for component anchoring in articular surface replacements, also in the case of proximal interphalangeal (PIP) joint. Nevertheless, many existing prostheses for the PIP joint have failed to show sufficient osteointegration. CapFlex-PIP(©) implant is a modular metal-polyethylene surface replacement for the PIP joint consisting of a proximal and distal component each having a titanium pore backside, which allows secondary osteointegration at the bone-implant interface. To evaluate osseous integration of this implant, we report a histological analysis of an explantation of a CapFlex-PIP(©) finger implant. CASE PRESENTATION: We present a case of a removed CapFlex-PIP(©) implant due to a soft tissue complication in an 84-year-old woman. The patient received bisphosphonate medication as treatment for osteoporosis. For the histological analysis, the bone-implant contact (BIC) was measured on all stained sections using a Zeiss Axioplan microscope. The summated BIC was 40.7 % for the proximal component and 46.5 % for the distal component of the implant. Histology showed that the implant was in direct contact with the bone at various locations, with no signs of wear or degradation. CONCLUSIONS: This case demonstrates successful osteointegration of the CapFlex-PIP(©) implant. Both components of the investigated implant show osseous integration to an extent which is comparable to that of other load-bearing and articulating implants at different locations in the human body.


Assuntos
Artroplastia de Substituição de Dedo , Articulações dos Dedos/cirurgia , Prótese Articular , Osseointegração , Idoso de 80 Anos ou mais , Feminino , Humanos , Osteoartrite/cirurgia , Polietileno , Titânio
5.
ACS Biomater Sci Eng ; 10(7): 4575-4586, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38839046

RESUMO

Vertebroplasty is a minimally invasive surgical procedure used to treat vertebral fractures, which conventionally involves injecting poly(methyl methacrylate) (PMMA) bone cement into the fractured vertebra. A common risk associated with vertebroplasty is cement leaking out of the vertebra during the injection, which may occur due to a lack of understanding of the complex flow behavior. Therefore, experiments to quantify the cement's flow properties are necessary for understanding and proper handling of the bone cement. In this study, we aimed to characterize the behavior of PMMA bone cement in its curing stages to obtain parameters that govern the flow behavior during injection. We used rotational and oscillatory rheometry for our measurements, as well as a custom-made injector setup that replicated a typical vertebroplasty setting. Our results showed that the complex viscoelastic behavior of bone cement is significantly affected by deformations and temperature. We found that the results from rotational tests, often used for characterizing the bone cement, are susceptible to measurement artifacts caused by wall slip and "ridge"-like formations in the test sample. We also found the Cox-Merz rule to be conditionally valid, which affects the use of oscillatory tests to obtain the shear-thinning characteristics of bone cement. Our findings identify important differences in the measured flow behavior of PMMA bone cement when assessed by different rheological methods, an understanding that is crucial for its risk-free usage in downstream medical applications.


Assuntos
Cimentos Ósseos , Polimetil Metacrilato , Reologia , Vertebroplastia , Polimetil Metacrilato/química , Cimentos Ósseos/química , Vertebroplastia/métodos , Teste de Materiais/métodos , Viscosidade , Humanos , Temperatura
6.
Arch Orthop Trauma Surg ; 133(3): 381-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23224427

RESUMO

PURPOSE: Rotator cuff (RC) repair-especially in the elderly population-is problematic since the patients suffer to a high extent from bone mineral density loss at the reattachment site. Therefore, the study was primarily driven by the question whether it is possible to reach more or qualitatively better cancellous bone and thus a more stable postoperative result if anchors with greater length are used for RC repair and/or the conventional anchors are screwed deeper into the bone. In anatomical terms, the question is raised whether cancellous bone is of better quality close to or far off the RC enthesis. METHODS: Axial HRqCT scans (X-tremeCT, Scanco Medical) of 36 human cadaveric humeral heads (75 ± 11 years) were performed to determine the ratio of bone volume to total volume (BV/TV), trabecular thickness (Trab Th), number of trabecles (Trab N), trabecular separation (Trab Sp) as well as non-metric indices such as connectivity density (Conn Dens) and structure model index (SMI). Within the greater tuberosity (GT), 6 volumes of interest (VOI) (A1, B1, C1, A2, B2, C2), in the lesser tuberosity (LT) 2 VOIs (D1, D2) and one control VOI in the subchondral bone were set. The analyzed bone cylinder of each VOI was divided into a superficial and a deep portion. RESULTS: The parameters BV/TV, Trab N, Trab Th and Conn Dens in all volumes of the GT and LT revealed higher values in the superficial portion reaching different levels of significance (p < 0.001/<0.05). The only parameter presenting a higher value in the deep portion was Trab Sp, but this was the case for all GT and LT regions. Interestingly, the difference between the superficial and deep portion reached significance for the non-metric parameter SMI in no volume of the GT/LT, although the higher values were found superficially. CONCLUSIONS: Our data show that cancellous bone presents with decreasing bone quality when analyzing increasingly deeper portions of the bone cylinders of the GT and LT starting at the articular surface. This information seems to be crucial for shoulder surgeons, especially when treating elderly patients. Our results clearly prove that screwing in anchors to a deeper extent will not improve stability, since the deeper bone stock is of worse quality.


Assuntos
Úmero/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Feminino , Humanos , Úmero/cirurgia , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Osteoporose/cirurgia , Tomografia Computadorizada por Raios X
7.
BMC Musculoskelet Disord ; 13: 221, 2012 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-23148627

RESUMO

BACKGROUND: Age-dependent trabecular changes of the humeral head might weaken the fixation of suture anchors used for rotator cuff (RC) repair. This might lead to suture anchor loosening and thus compromise the integrity of the repair. The aim of this study was to analyze whether the trabecular microstructure within the RC footprint is influenced by age, gender or handedness. METHODS: Axial HR-pQCT scans (Scanco Medical) of 64 freshly frozen cadaveric human humeral head specimens (age 72.3 ± 17.4 years) were analyzed to determine the bone volume-to-total volume ratio (BV/TV), trabecular thickness (Trab Th), trabecular number (Trab N) and connectivity density (Conn Dens). Within the RC footprint, 2 volumes of interest (VOI), posteromedial (PM) and anterolateral (AL) and one control VOI in the subarticular bone (SC) were set. RESULTS: The highest BV/TV was found in SC: 0.22 ± 0.06% vs. PM: 0.04 ± 0.05% vs. AL: 0.02 ± 0.04%; p < 0.05. Trab Th accounted for 0.26 ± 0.05 µm in SC, 0.23 ± 0.09 µm in AL and 0.21 ± 0.05 µm in PM. In parallel, Trab N and Conn Dens were found to be the highest in SC. Gender analysis yielded higher values for BV/TV, Trab Th, Trab N and Conn Dens for PM in males compared to females (p < 0.05). There were no significant findings when comparing both sides. We furthermore found a strong inverse correlation between age and BV/TV, which was more pronounced in the female specimens (r = -0.72, p < 0.00001). CONCLUSIONS: The presented microarchitectural data allow for future subtle biomechanical testing comprising knowledge on age- and sex-related changes of the tuberosities of the humeral head. Furthermore, the insights on the trabecular structure of the humeral head of the elderly may lead to the development of new fixation materials in bone with inferior bone quality.


Assuntos
Envelhecimento/fisiologia , Densidade Óssea/fisiologia , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/fisiologia , Caracteres Sexuais , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Knee Surg Sports Traumatol Arthrosc ; 20(6): 1036-41, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21971940

RESUMO

PURPOSE: The nature and the distribution of fibrocartilage at the human glenoid labrum are unclear, and a better understanding may help to restore its function in open and arthroscopic Bankart repair. Aim of this study was to describe the fibrocartilage extent within the labrum at clinically relevant sites of the glenoid in order to relate the molecular composition of the labrum to its mechanical environment. METHODS: Twelve fresh frozen human cadaveric shoulders (mean age 38 years) were obtained, and sections perpendicular to the glenoid rim at the 12, 2, 3, 4, 6 and 9 o' clock position were labelled with antibodies against collagen I and II, aggrecan and link protein. RESULTS: A fibrocartilaginous transition zone with a characteristic collagen fibre orientation was found in 81% of cases, evenly distributed (83-92%) around the glenoid rim. The percentage of labrum cross-sectional area comprised of fibrocartilage averaged 28% and ranged from 26% at 12 o'clock on the glenoid clock face to 30% at 3 o'clock. The highest amount of fibrocartilage (82%) was found in the region neighbouring the hyaline articular cartilage. In the region beyond the bony edge of the glenoid, fibrocartilage cross-sectional area did not exceed 12-17%. CONCLUSION: Fibrocartilage is present at all examined positions around the glenoid rim and constitutes up to 1/3 of the cross-sectional area of the labrum. In turn, the percentage of fibrocartilage in different regions of its cross-section varies considerably. The findings suggest that the penetration of fibrocartilaginous tissue may be reduced by avoiding the highly fibrocartilage transition zone during restoration of labral detachment.


Assuntos
Fibrocartilagem/anatomia & histologia , Cavidade Glenoide , Articulação do Ombro/anatomia & histologia , Agrecanas/metabolismo , Biomarcadores/metabolismo , Colágeno Tipo I/metabolismo , Colágeno Tipo II/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Fibrocartilagem/metabolismo , Humanos , Imuno-Histoquímica , Proteoglicanas/metabolismo , Articulação do Ombro/metabolismo
9.
Eur Spine J ; 20(10): 1644-9, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21748494

RESUMO

STUDY DESIGN: Retrospective clinical study in patients with dorso-ventral thoraco-lumbar spondylodesis. OBJECTIVE: To investigate whether the ratio between graft cross sectional area and the surface area of the adjacent endplates has any effect on the midterm stability of the spondylodesis. Dorso-ventral spondylodesis in the region of the thoraco-lumbar spine is one of the most frequent operations in orthopaedic surgery. Anterior stabilization with autologous iliac crest graft currently is a standard approach in many hospitals. Although numerous recommendations are given how to perform this technique, no clinical advice is available with regard to minimum graft size. METHODS: Sixty-four-slice CT-scans were obtained from 82 patients 4-12 months after posterior spondylodesis with anterior implantation of iliac crest graft and stabilization with an internal fixator. The scans were analyzed using image analysis software. First, the cross sectional area of the graft was calculated and then the surface area of the adjacent endplates. The ratio between graft cross sectional area and endplate surface area was then calculated from these two values. The grafts were then evaluated in sagittal reconstruction for signs of fracture. RESULTS: The probability for graft fracture in autologous tricortical grafts was >0.1% (p < 0.001) if the graft cross sectional area exceeded 23.9% of the surface area of the adjacent endplates. Patients with lower ratio values had a higher fracture risk and below a value of 10% all grafts fractured. CONCLUSION: The relationship between graft cross sectional area and adjacent endplate area has an important effect on graft midterm stability in ventral spondylodesis of the thoraco-lumbar spine. In our opinion, the risk of graft fractures in dorso-ventral spondylodesis can be reduced by implantation of an appropriately sized graft without any additional procedures or instrumentation.


Assuntos
Transplante Ósseo/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Doenças da Coluna Vertebral/epidemiologia , Doenças da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/epidemiologia , Fusão Vertebral/efeitos adversos , Adolescente , Adulto , Idoso , Transplante Ósseo/métodos , Feminino , Humanos , Fixadores Internos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Fatores de Risco , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fusão Vertebral/normas , Vértebras Torácicas/cirurgia , Adulto Jovem
10.
Arch Osteoporos ; 16(1): 33, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33594610

RESUMO

Cortical thickness determined at the humerus can serve as an easy and reliable screening tool to predict the local bone status when quantitative bone mineral density (BMD) measurements are not available. It can therefore serve as a rapid screening tool in fragility fractures to identify patients requiring further diagnostic or osteoporosis treatment. INTRODUCTION: Quantitative bone mineral density (BMD) of the humerus is difficult to determine but relevant for osteoporosis and fracture treatment. Dual-energy X-ray absorptiometry (DXA) of the femur and lumbar spine overestimates the humeral BMD and is not ubiquitously available. Therefore, this study evaluated whether the cortical bone thickness (CBT) of the humerus or DXA of the forearm is able to predict humeral BMD. METHODS: Humeral BMD of 54 upper cadaver extremities (22 pairs, 10 single) (19-90 years) was determined by high-resolution peripheral-quantitative-computed-tomography (HR-pQCT) (volumetric BMD (vBMD)) and DXA (areal BMD (aBMD)) of the proximal humerus and distal forearm. Average and gauge cortical bone thickness (CBTavg/ CBTg) of the humeral diaphysis was determined from standard radiographs (XR) and computed-tomography (CT) and compared to the humeral BMD. Pearson (r) and intraclass-correlation-coefficients (ICC) were used to compare results and rater-reliability. RESULTS: CBTavg from XR strongly correlated with the humeral BMD (r = 0.78 aBMD (DXA) and r = 0.64 vBMD (HR-pQCT) (p < 0.0001)). The CBTg revealed a weaker correlation (r = 0.57 aBMD and r = 0.43 vBMD). CBT derived from XR strongly correlated to those from the CT (r = 0.82-0.90) and showed an excellent intra- and inter-rater correlation (ICC 0.79-0.92). Distal forearm aBMD correlated well with the humeral aBMD (DXA) (r = 0.77) and paired specimens highly correlated to the contralateral side (humerus r = 0.89, radius r = 0.97). CONCLUSIONS: The CBTavg can reliably be determined from standard radiographs and allows a good prediction of quantitative humeral bone mineral density (aBMD or vBMD) if measurements are not available. Furthermore, the distal forearm or the contralateral humerus can serve as a side to estimate the BMD if the ipsilateral side is impaired.


Assuntos
Densidade Óssea , Úmero , Absorciometria de Fóton , Osso Cortical , Humanos , Úmero/diagnóstico por imagem , Reprodutibilidade dos Testes
11.
Materials (Basel) ; 13(21)2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33105759

RESUMO

Hydroxyapatite (HA) coatings have become very popular in uncemented total hip arthroplasty (THA). Analysis of retrievals and tissue samples from an HA-coated femoral stem, which failed within 14 months after THA, provides exceptional insights into the failure mechanism, as well as the process of osteointegration of such an implant. METHODS: Retrievals were photo-documented. Samples were examined by micro-computed tomography, X-ray diffraction (XRD) and embedded in polymethylmethacrylate for histology. RESULTS: The coating had partially delaminated. The sandblasted surface of the stem was partially polished by the delaminated HA coating, indicating failure before revision. In the tissue samples, the HA coating was well integrated by newly formed bone trabeculae. No adverse biological reaction was observed. XRD analysis showed that residues of the HA coating were still present and could clearly be differentiated from the surrounding bone. Preferential orientation of the HA crystallites could be identified within the newly formed bone, representing a potential mechanical weakness induced either by physiologic strain or by the coating. CONCLUSION: current HA coatings, relatively thick and made of high crystallinity HA, may be prone to delamination, as also seen in our study. Recent efforts have aimed towards thinner (<1 µm) coatings with nanocrystalline HA structures that possibly relate to lower delamination risks. However, the question arises if HA coatings are beneficial since sandblasted non-coated stems offer similar results without the risk of delamination. XRD not only permits differentiation between the HA from the coating and the HA of the ongrown bone, it also provides new insights into the microstructure of this newly formed bone.

12.
Dent Mater ; 36(3): 402-412, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31992485

RESUMO

OBJECTIVE: Titanium (Ti)- and Zirconia (ZrO2)-implants in mini pig maxillae were compared with respect to Ti/zirconium (Zr) release into the surrounding bone tissues, the resulting short term tissue responses and the potential toxicity. METHODS: Ti/Zr release from Ti- and ZrO2-implants in mini pig maxillae was determined with inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). The spatial distribution of Ti and Zr in maxilla tissues near the implant surface was assessed with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). A histological analysis was performed to investigate the tissue responses after 12 weeks of implantation. The cytotoxicity and DNA damage of Ti particles and ZrO2 particles were studied with XTT and Comet assay. RESULTS: The mean Ti content in the bone adjacent to Ti-implants was 1.67 mg/kg-bone weight. The highest Ti content detected was 2.17 mg/kg-bone weight. The mean Zr content in the bone adjected to ZrO2-implants was 0.59 mg/kg-bone weight. The highest Zr content was 0.75 mg/kg-bone weight. The spatial distribution of the Ti and Zr in bone showed mainly a higher intensity of Ti and Zr close to the screw thread outer tip rather. Histological analysis indicated that near both implant-types signs of bone marrow fibrosis were present. EC50 of commercially available ZrO2-nanoparticles (NPs, <100 nm) and ZrO2-microparticles (MPs, <5 µm) was 13.96 mg/ml and 80.99 mg/ml, respectively. ZrO2-NPs and ZrO2-MPs can induce DNA damage at 70 µg/ml and 810 µg/ml, respectively. SIGNIFICANCE: After 12-weeks of implantation, increased concentrations of Ti and Zr can be detected in bone/tissues near Ti- and ZrO2-implants in mini pig maxillae. Ti content released from Ti-implants is two times higher than the Zr content released from ZrO2-implants. ZrO2-NPs showed lower cytotoxicity and DNA damage compared to results reported for Ti-NPs in human cells.


Assuntos
Implantes Dentários , Zircônio , Animais , Humanos , Maxila , Propriedades de Superfície , Suínos , Porco Miniatura , Titânio
13.
PLoS One ; 14(2): e0210402, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30707699

RESUMO

Orthopedic device-related infection (ODRI) is a potentially devastating complication arising from the colonization of the device with bacteria, such as Staphylococcus aureus. The aim of this study was to determine if intraoperative loading of a clinically approved calcium phosphate (CaP) coating with gentamicin can protect from ODRI in vivo. First, CaP-coated titanium aluminium niobium (TAN) discs were used to investigate the adsorption and release kinetics of gentamicin in vitro. Gentamicin loading and subsequent release from the coating were both rapid, with maximum loading occurring following one second of immersion, and >95% gentamicin released within 15 min in aqueous solution, respectively. Second, efficacy of the gentamicin-loaded CaP coating for preventing ODRI in vivo was investigated using a CaP-coated unicortical TAN screw implanted into the proximal tibia of skeletally mature female Wistar rats, following inoculation of the implant site with S. aureus. Gentamicin-loading prevented ODRI in 7/8 animals, whereas 9/9 of the non-gentamicin treated animals were infected after 7 days. In conclusion, gentamicin can be rapidly and simply loaded onto, and released from, CaP-based implant coatings, and this is an effective strategy for preventing peri-operative S. aureus-induced ODRI in vivo.


Assuntos
Fosfatos de Cálcio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Gentamicinas/farmacologia , Cuidados Intraoperatórios , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/crescimento & desenvolvimento , Ligas/farmacologia , Animais , Parafusos Ósseos , Feminino , Nióbio/farmacologia , Ratos , Ratos Wistar , Tíbia/metabolismo , Tíbia/microbiologia , Tíbia/patologia
14.
J Anat ; 212(5): 697-701, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18410315

RESUMO

Elderly patients frequently suffer from osteoporotic vertebral fractures resulting in the need of vertebroplasty or kyphoplasty. Nevertheless, no data are available about the long-term consequences of cement injection into osteoporotic bone. Therefore, the aim of the present study was to evaluate the long-term tissue reaction on bone cement injected to osteoporotic bone during vertebroplasty. The thoracic spine of an 80-year-old female was explanted 3.5 years after vertebroplasty with polymethylmethacrylate. The treatment had been performed due to painful osteoporotic compression fractures. Individual vertebral bodies were cut in axial or sagittal sections after embedding. The sections were analysed using contact radiography and staining with toluidine blue. Furthermore, selected samples were evaluated with scanning electron microscopy and micro-compted tomography (in-plane resolution 6 microm). Large amounts of newly formed callus surrounding the injected polymethylmethacrylate were detected with all imaging techniques. The callus formation almost completely filled the spaces between the vertebral endplate, the cancellous bone, and the injected polymethylmethacrylate. In trabecular bone microfractures and osteoclast lacuna were bridged or filled with newly formed bone. Nevertheless, the majority of the callus formation was found in the immediate vicinity of the polymethylmethacrylate without any obvious relationship to trabecular fractures. The results indicate for the first time that, contrary to established knowledge, even in osteoporosis the formation of large amounts of new bone is possible.


Assuntos
Cimentos Ósseos/farmacologia , Fraturas por Compressão/cirurgia , Osteoporose Pós-Menopausa/cirurgia , Polimetil Metacrilato/farmacologia , Fraturas da Coluna Vertebral/cirurgia , Vertebroplastia/métodos , Idoso , Remodelação Óssea , Dissecação , Feminino , Fraturas por Compressão/etiologia , Humanos , Microscopia Eletrônica de Varredura , Osteoporose Pós-Menopausa/complicações , Fraturas da Coluna Vertebral/etiologia , Coloração e Rotulagem , Tempo , Tomografia Computadorizada por Raios X
15.
AJR Am J Roentgenol ; 190(5): 1255-9, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18430840

RESUMO

OBJECTIVE: In spinal surgery, anterior spondylodesis is often combined with bone grafting, and graft integration is assessed with CT. High-resolution peripheral quantitative CT offers a resolution of 82 mum. The aim of this study was to compare the outcome of anterior spondylodesis as assessed with three radiologic procedures. MATERIALS AND METHODS: Monosegmental lumbar spondylodesis with autologous iliac crest graft or solvent-preserved bovine cancellous bone was performed on seven sheep. The fused spinal segments were explanted after 24 weeks and examined with clinical 64-MDCT, high-resolution peripheral quantitative CT, and contact radiography. In 2D views, the area of the disk space bridged by bone was assessed, and the grafts were examined for fractures. RESULTS: In three of seven sheep, clinical CT erroneously showed stable consolidation, whereas contact radiography revealed a clearly visible graft fracture, as did high-resolution peripheral quantitative CT. There was a statistically significant difference (p = 0.038) between bone volume assessed with clinical CT and that assessed with contact radiography. There was an almost significant difference (p = 0.053) between volumes assessed with high-resolution peripheral quantitative CT and clinical MDCT. CONCLUSION: High-resolution peripheral quantitative CT, a technique approved for clinical use, has higher resolution in imaging of bone structure than does 64-MDCT. Our results show that high-resolution peripheral quantitative CT is superior to 64-MDCT in assessing osseous implant integration after anterior spondylodesis. The specimen size limit, however, prohibits in vivo use of this method in evaluation of the human spine. Our results suggest that in clinical practice, persisting symptoms despite radiologic findings of consolidated spondylodesis may be related to graft failure, which cannot be detected with clinically available methods.


Assuntos
Transplante Ósseo , Vértebras Lombares , Osseointegração , Fusão Vertebral , Tomografia Computadorizada por Raios X/métodos , Animais , Feminino , Sobrevivência de Enxerto , Reprodutibilidade dos Testes , Ovinos , Resultado do Tratamento
16.
BMC Musculoskelet Disord ; 9: 138, 2008 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-18847508

RESUMO

BACKGROUND: Concerning surgical management experience with locking plates for proximal humeral fractures has been described with promising results. Though, distinct hardware related complaints after fracture union are reported. Information concerning the outcome after removal of hardware from the proximal humerus is lacking and most studies on hardware removal are focused on the lower extremity. Therefore the aim of this study was to analyze the functional short-term outcome following removal of locking plate fixation of the proximal humerus. METHODS: Patients undergoing removal of a locking plate of the proximal humerus were prospectively followed. Patients were subdivided into the following groups: Group HI: symptoms of hardware related subacromial impingement, Group RD: persisting rotation deficit, Group RQ: patients with request for a hardware removal. The clinical (Constant-Murley score) and radiologic (AP and axial view) follow-up took place three and six months after the operation. To evaluate subjective results, the Medical Outcomes Study Short Form-36 (SF-36), was completed. RESULTS: 59 patients were included. The mean length of time with the hardware in place was 15.2 +/- 3.81 months. The mean of the adjusted overall Constant score before hardware removal was 66.2 +/- 25.2% and increased significantly to 73.1 +/- 22.5% after 3 months; and to 84.3 +/- 20.6% after 6 months (p < 0.001). The mean of preoperative pain on the VAS-scale before hardware removal was 5.2 +/- 2.9, after 6 months pain in all groups decreased significantly (p < 0.001). The SF-36 physical component score revealed a significant overall improvement in both genders (p < 0.001) at six months. CONCLUSION: A significant improvement of clinical outcome following removal was found. However, a general recommendation for hardware removal is not justified, as the risk of an anew surgical and anesthetic procedure with all possible complications has to be carefully taken into account. However, for patients with distinct symptoms it might be justified.


Assuntos
Placas Ósseas , Fixadores Internos , Fraturas do Ombro/fisiopatologia , Fraturas do Ombro/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Consolidação da Fratura/fisiologia , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida , Radiografia , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
17.
J Biomed Mater Res B Appl Biomater ; 106(8): 2924-2931, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30199602

RESUMO

Infection associated with an implant is a complication feared in surgery, as it leads to loosening and dysfunction. This report documents an unexpected good bony integration of a porous tantalum shoulder prosthesis despite infection. A shoulder prosthesis with a porous tantalum glenoidal base plate was retrieved after 3 years of ongoing infection with Staphylococcus spp. Methyl-methacrylate embedded sections of the retrieved glenoidal component were analyzed by optical and scanning electron beam microscopy (SEM). Bone ongrowth and ingrowth were quantified. Bone had formed at the implant surface and within the open cell structure of the porous tantalum. The bone implant contact index was 32%. The bone ingrowth or relative bone area within the open structure was 8.2%, respectively 11.9% in the outer 50% of the thickness. Due to the section thickness, bone ongrowth could best be documented in SEM. Despite long-lasting and ongoing infection, the glenoidal base plate of the prosthesis showed good bony integration upon removal. The bone ingrowth into the porous tantalum was comparable to the values previously reported for the undersurface of retrieved proximal humerus resurfacing implants. Good integration of the implant however did not solve the problem of infection, and related morbidity. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2924-2931, 2018.


Assuntos
Interface Osso-Implante , Próteses e Implantes/efeitos adversos , Prótese de Ombro/efeitos adversos , Infecções Estafilocócicas , Staphylococcus , Idoso , Interface Osso-Implante/microbiologia , Interface Osso-Implante/patologia , Feminino , Cavidade Glenoide/microbiologia , Cavidade Glenoide/patologia , Humanos , Úmero/microbiologia , Úmero/patologia , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/patologia , Titânio
18.
Am J Vet Res ; 79(9): 970-979, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30153050

RESUMO

OBJECTIVE To evaluate and compare surface and cross-sectional structure as well as localized electrochemical corrosion and ion release for cast stainless steel (SS) tibia plateau leveling osteotomy (TPLO) plates retrieved from dogs with and without osteosarcoma (OSA) and to compare these findings with similar variables for forged SS TPLO plates retrieved from dogs. SAMPLE 47 TPLO plates explanted from 45 client-owned dogs (22 cast plates from dogs with OSA, 22 cast plates from dogs without OSA, and 3 forged plates from dogs without OSA). PROCEDURES Histologic evaluations of tissue samples collected from implant sites at the time of plate retrieval were performed to confirm implant site tumor status of each dog. Surfaces and metallographic cross sections of retrieved plates were examined, and the microcell technique was used to obtain local electrochemical corrosion and ion release measurements. RESULTS Findings indicated that all cast SS plates demonstrated high spatial variability of their electrochemical surface properties and inhomogeneous superficial and cross-sectional composition, compared with forged plates. Greater metal ion release was observed in cast plates than in forged plates and in cast plates from dogs with OSA than in cast or forged from dogs without OSA. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that accumulation of metal ions from implants could be a trigger for neoplastic transformation in neighboring cells. Metal ion release caused by corrosion of implants that do not comply with recommended standards of the American Society for Testing and Materials International or the International Organization for Standardization could potentially place patients at increased risk of tumor development.


Assuntos
Neoplasias Ósseas/veterinária , Placas Ósseas/veterinária , Doenças do Cão/patologia , Osteossarcoma/veterinária , Osteotomia/veterinária , Animais , Corrosão , Estudos Transversais , Cães , Técnicas Eletroquímicas , Masculino , Teste de Materiais , Osteotomia/métodos , Estudos Retrospectivos , Aço Inoxidável , Propriedades de Superfície , Tíbia/cirurgia
19.
J Tissue Eng Regen Med ; 12(2): 321-329, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28486746

RESUMO

The ability to engineer scaffolds that resemble the transition between tissues would be beneficial to improve repair of complex organs, but has yet to be achieved. In order to mimic tissue organization, such constructs should present continuous gradients of geometry, stiffness and biochemical composition. Although the introduction of rapid prototyping or additive manufacturing techniques allows deposition of heterogeneous layers and shape control, the creation of surface chemical gradients has not been explored on three-dimensional (3D) scaffolds obtained through fused deposition modelling technique. Thus, the goal of this study was to introduce a gradient functionalization method in which a poly(ε-caprolactone) surface was first aminolysed and subsequently covered with collagen via carbodiimide reaction. The 2D constructs were characterized for their amine and collagen contents, wettability, surface topography and biofunctionality. Finally, chemical gradients were created in 3D printed scaffolds with controlled geometry and porosity. The combination of additive manufacturing and surface modification is a viable tool for the fabrication of 3D constructs with controlled structural and chemical gradients. These constructs can be employed for mimicking continuous tissue gradients for interface tissue engineering.


Assuntos
Colágeno/farmacologia , Poliésteres/farmacologia , Impressão Tridimensional , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Linhagem Celular Tumoral , Humanos , Ratos , Resistência à Tração , Microtomografia por Raio-X
20.
Am J Vet Res ; 67(7): 1258-65, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16817752

RESUMO

OBJECTIVE: To determine the material properties of Slocum TPLO plates and assess the soft tissue reaction adjacent to these plates in dogs that had undergone tibial plateau leveling osteotomy (TPLO). SAMPLE POPULATION: 3 new TPLO plates, 8 retrieved TPLO plates, and 1 new Synthes dynamic compression plate. PROCEDURES: Metallurgic analyses were performed. Tissue samples were obtained from areas adjacent to retrieved plates and submitted for histologic examination. RESULTS: All of the TPLO plates had a 2-phase microstructure consisting of austenite and ferrite in various amounts. Residua, inclusions, and cavities were seen during microscopic examination of the plate surface. The major differences between new and retrieved TPLO plates were the presence of small gaps separating many inclusions from the surrounding matrix and the presence of various-sized pits on the surface of the retrieved plates. The dynamic compression plate had a nearly pure austenitic structure and was largely free from residua, inclusions, and cavities. Histologic examination of tissue samples obtained from areas adjacent to retrieved TPLO plates revealed intra- and extracellular particulate debris. Two types of particles (one consisting of chromium, nickel, molybdenum, and iron and the other consisting of aluminum and silicon) were seen. CONCLUSIONS AND CLINICAL RELEVANCE: Results determined that new and retrieved TPLO plates were manufactured from 316L stainless steel and produced by a casting process, but not all plates met specifications for chemical composition of cast surgical implants (American Society for Testing Materials standard F745); tissues surrounding retrieved plates had evidence of adverse reactions, probably as a result of plate corrosion.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Placas Ósseas/veterinária , Doenças do Cão/cirurgia , Lesões dos Tecidos Moles/veterinária , Animais , Materiais Biocompatíveis/química , Placas Ósseas/efeitos adversos , Cães , Osteotomia , Lesões dos Tecidos Moles/etiologia