Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Pediatr ; 273: 114132, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38823628

RESUMO

OBJECTIVE: To define percentile charts for arterial oxygen saturation (SpO2), heart rate (HR), and cerebral oxygen saturation (crSO2) during the first 15 minutes after birth in neonates born very or extremely preterm and with favorable outcome. STUDY DESIGN: We conducted a secondary-outcome analysis of neonates born preterm included in the Cerebral regional tissue Oxygen Saturation to Guide Oxygen Delivery in preterm neonates during immediate transition after birth III (COSGOD III) trial with visible cerebral oximetry measurements and with favorable outcome, defined as survival without cerebral injuries until term age. We excluded infants with inflammatory morbidities within the first week after birth. SpO2 was obtained by pulse oximetry, and electrocardiogram or pulse oximetry were used for measurement of HR. crSO2 was assessed with near-infrared spectroscopy. Measurements were performed during the first 15 minutes after birth. Percentile charts (10th to 90th centile) were defined for each minute. RESULTS: A total of 207 neonates born preterm with a gestational age of 29.7 (23.9-31.9) weeks and a birth weight of 1200 (378-2320) g were eligible for analyses. The 10th percentile of SpO2 at minute 2, 5, 10, and 15 was 32%, 52%, 83%, and 85%, respectively. The 10th percentile of HR at minute 2, 5, 10, and 15 was 70, 109, 126, and 134 beats/min, respectively. The 10th percentile of crSO2 at minute 2, 5, 20, and 15 was 15%, 27%, 59%, and 63%, respectively. CONCLUSIONS: This study provides new centile charts for SpO2, HR, and crSO2 for neonates born extremely or very preterm with favorable outcome. Implementing these centiles in guiding interventions during the stabilization process after birth might help to more accurately target oxygenation during postnatal transition period.


Assuntos
Frequência Cardíaca , Lactente Extremamente Prematuro , Oximetria , Saturação de Oxigênio , Humanos , Recém-Nascido , Frequência Cardíaca/fisiologia , Saturação de Oxigênio/fisiologia , Feminino , Masculino , Oximetria/métodos , Valores de Referência , Espectroscopia de Luz Próxima ao Infravermelho , Recém-Nascido Prematuro , Oxigênio/metabolismo , Oxigênio/sangue , Encéfalo/metabolismo , Idade Gestacional
2.
Acta Paediatr ; 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39193840

RESUMO

AIM: The aim of this study is to prevent mask leak during ventilation in infant emergencies, appropriate facemask fitting is essential. Therefore, we investigated facial profiles during the first year of life and their correlation with the correct sizing of masks. METHODS: This is a post hoc subgroup analysis of 32 healthy term infants, based on a prospective observational study performed from September 2018 to December 2019 in Tuebingen, Germany. In 3-monthly intervals, facial aspects were measured based on anatomical landmarks in three-dimensional frontal photographs to describe their changes across the first year of life. All infants were awake and breathing spontaneously; none required any anaesthesia. RESULTS: In 130 3D images, mean distance between nasion and gnathion was 54 mm (3.3) measured at birth and 70 mm (3.5) at age 12 months. Gompertz models showed relevant growth-related changes in the facial profile in vertical but not horizontal direction. Vertical growth occurred mainly in the first 6 months. Boys and girls differed by an average of about 2 mm (boys >girls). CONCLUSION: Based on our findings, it should now be verified whether the 50 mm facemasks are suitable for infants from birth to 2 months of age, respectively, the 60 mm version for infants aged three to 12 months.

3.
Acta Paediatr ; 112(1): 63-68, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36177808

RESUMO

AIM: The aim of this study was to assess the resuscitators' opinions of the usefulness and clinical value of using a respiratory function monitor (RFM) when resuscitating extremely preterm infants with positive pressure ventilation. METHODS: The link to an online survey was sent to 106 resuscitators from six countries who were involved in a multicentre trial that compared the percentage of inflations within a predefined target range with and without the RFM. The resuscitators were asked to assess the usefulness and clinical value of the RFM. The survey was online for 4 months after the trial ended in May 2019. RESULTS: The survey was completed by 74 (70%) resuscitators of which 99% considered the RFM to be helpful during neonatal resuscitation and 92% indicated that it influenced their decision-making. The majority (76%) indicated that using the RFM improved their practice and made resuscitation more effective, even when the RFM was not available. Inadequate training was the key issue that limited the effectiveness of the RFM: 45% felt insufficiently trained, and 78% felt more training in using and interpreting the RFM would have been beneficial. CONCLUSION: Resuscitators considered the RFM to be helpful to guide neonatal resuscitation, but sufficient training was required to achieve the maximum benefit.


Assuntos
Recém-Nascido Prematuro , Ressuscitação , Recém-Nascido , Humanos
4.
Am J Respir Crit Care Med ; 203(8): 998-1005, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33095994

RESUMO

Rationale: There is increasing evidence for a clinical benefit of noninvasive high-frequency oscillatory ventilation (nHFOV) in preterm infants. However, it is still unknown whether the generated oscillations are effectively transmitted to the alveoli.Objectives: To assess magnitude and regional distribution of oscillatory volumes (VOsc) at the lung level.Methods: In 30 prone preterm infants enrolled in a randomized crossover trial comparing nHFOV with nasal continuous positive airway pressure, electrical impedance tomography recordings were performed. During nHFOV, the smallest amplitude to achieve visible chest wall vibration was used, and the frequency was set at 8 hertz.Measurements and Main Results: Thirty consecutive breaths during artifact-free tidal ventilation were extracted for each of the 228 electrical impedance tomography recordings. After application of corresponding frequency filters, Vt and VOsc were calculated. There was a signal at 8 and 16 Hz during nHFOV, which was not detectable during nasal continuous positive airway pressure, corresponding to the set oscillatory frequency and its second harmonic. During nHFOV, the mean (SD) VOsc/Vt ratio was 0.20 (0.13). Oscillations were more likely to be transmitted to the non-gravity-dependent (mean difference [95% confidence interval], 0.041 [0.025-0.058]; P < 0.001) and right-sided lung (mean difference [95% confidence interval], 0.040 [0.019-0.061]; P < 0.001) when compared with spontaneous Vt.Conclusions: In preterm infants, VOsc during nHFOV are transmitted to the lung. Compared with the regional distribution of tidal breaths, oscillations preferentially reach the right and non-gravity-dependent lung. These data increase our understanding of the physiological processes underpinning nHFOV and may lead to further refinement of this novel technique.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Volume Expiratório Forçado/fisiologia , Ventilação de Alta Frequência/métodos , Recém-Nascido Prematuro/fisiologia , Ventilação não Invasiva/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Estudos Cross-Over , Feminino , Humanos , Recém-Nascido , Masculino
5.
BMC Pediatr ; 22(1): 543, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100886

RESUMO

BACKGROUND: We sought to assess tidal volumes in (near) term infants during delivery room stabilization. METHODS: Secondary analysis of a prospective study comparing two facemasks used for positive pressure ventilation (PPV) in newborn infants ≥ 34 weeks gestation. PPV was provided with a T-piece device with a PIP of 30 cmH2O and positive end-expiratory airway pressure of 5 cmH2O. Expired tidal volumes (Vt) were measured with a respiratory function monitor. Target range for Vt was defined to be 4 - 8 ml/kg. RESULTS: Twenty-three infants with a median (IQR) gestational age of 38.1 (36.4 - 39.0) weeks received 1828 inflations with a median Vt of 4.6 (3.3 - 6.2) ml/kg. Median Vt was in the target range in 12 infants (52%), lower in 9 (39%) and higher in 2 (9%). Thirty-six (25-27) % of the inflations were in the target rage over the duration of PPV while 42 (25 - 65) % and 10 (3 - 33) % were above and below target range. CONCLUSIONS: Variability of expiratory tidal volume delivered to term and late preterm infants was wide. Reliance on standard pressures and clinical signs may be insufficient to provide safe and effective ventilation in the delivery room. TRIAL REGISTRATION: This is a secondary analysis of a prospectively registered randomized controlled trial (ACTRN12616000768493).


Assuntos
Salas de Parto , Recém-Nascido Prematuro , Feminino , Humanos , Lactente , Recém-Nascido , Respiração com Pressão Positiva , Gravidez , Estudos Prospectivos , Volume de Ventilação Pulmonar
6.
BMC Pediatr ; 21(1): 417, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34556062

RESUMO

BACKGROUND: Recommendations for endotracheal tube (ETT) size usually refer to the inner diameter (ID). Outer diameters (OD), however, vary greatly between manufacturers, which in some brands might cause difficulties in passing the ETT through the nostrils if choosing the nasal route for intubation. Even though the nostrils are dilatable by an ETT, it might be difficult to pass an ETT through the posterior naris (narrowest point of the nasal passage), if the OD is bigger than the nostrils. Therefore, nostril size may provide some guidance for the appropriate ETT size preventing unsuccessful intubation attempts. This study therefore compares nostril sizes of newborn infants with ODs of ETTs from several manufacturers. METHODS: This is a subgroup analysis of a prospective observational study, performed in a single tertiary perinatal centre in Germany. The diameter of the nostril of infants born between 34 and 41 weeks´ gestation was measured in 3D images using 3dMDvultus software and compared to the OD of ETT from five different manufacturers. RESULTS: Comparisons of nostril sizes with ODs of different ETTs were made for 99 infants with a mean (SD) birthweight of 3058g (559) [range: 1850-4100g]. Mean (SD) nostril size was 5.3mm (0.6). The OD of the 3.5mm ETT of different manufacturers ranged from 4.8-5.3mm and was thus larger than the nostril size of 20-46% of late preterm or term infants. Some OD of a 3.0mm ETT were even bigger than the OD of a 3.5mm ETT (e.g. the 3.0mm ETT from Rüsch® has an OD of 5.0mm while the 3.5mm ETT from Portex® has an OD of 4.8mm). CONCLUSIONS: Clinicians should be aware of the OD of ETTs to reduce unsuccessful intubation attempts caused by ETT sizes not fitting the nasal cavity. Generated data may help to adapt recommendations in future. TRIAL REGISTRATION: Subgroup analysis of the "Fitting of Commonly Available Face Masks for Late Preterm and Term Infants (CAFF)"-study: NCT03369028, www.ClinicalTrials.gov , December 11, 2017.


Assuntos
Intubação Intratraqueal , Cavidade Nasal , Desenho de Equipamento , Alemanha , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos
7.
Paediatr Anaesth ; 31(4): 404-409, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33555071

RESUMO

BACKGROUND: The neutral or sniffing position is advised for mask ventilation in neonates to avoid airway obstruction. As definitions are manifold and often unspecific, we wanted to investigate the reliability and reproducibility of angle measurements based on facial landmarks that may be used in future clinical trials to determine a hypothetical head position with minimal airway obstruction during mask ventilation. METHODS: In a prospective single-center observational study, 2D sagittal photographs of 24 near-term and term infants were taken, with five raters marking facial landmarks to assess interobserver agreement of those landmarks and angle δ, defined as the angle between the line parallel to the lying surface and the line crossing Subnasale (Sn) and Porion' (P'). Angle δ was assessed in sniffing (δsniff ) and physiologic (δphys ) head position, the former based on a published, yet poorly defined head position where the tip of the nose aligns to the ceiling with the head in a supine, relaxed mid-position. RESULTS: Infants had a mean (SD) gestational age of 37.3 (2.3) weeks. Angle δ could be determined in all 48 images taken in either the sniffing or the physiological head position. Interobserver correlation coefficient was 98.6 for all measurements independent of head position. Angle δsniff was 90.5° (5.7) in the sniffing position. CONCLUSIONS: This study provides a new measuring technique using an angle that is reproducible and reliable and may be used in future studies to correlate head position with airway obstruction.


Assuntos
Obstrução das Vias Respiratórias , Cabeça , Cabeça/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Postura , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
BMC Pediatr ; 20(1): 405, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32854665

RESUMO

BACKGROUND: Venous access during neonatal emergencies in the delivery room (DR) can be accomplished through an umbilical venous catheter (UVC) or an intraosseous (IO) access. Preference of one over the other is unclear. We wanted to evaluate practioners' views. METHODS: An anonymous online questionnaire was circulated to healthcare professionals with different background and experience, all working in neonatal intensive care units in Germany. The web-based survey consisted of 13 questions and data collection was performed using an online tool. RESULTS: We received 502 completed questionnaires, 152 (30%) were from neonatologists, the remainder from residents, fellows and neonatal nurses. For resuscitation of term newborns in the DR 61% of neonatologists vs. 53% of non-neonatologists were in favour of UVC instead of an IO as an emergency access. UVC placement was rated (very) difficult to impossible by 60% of neonatologists and 90% of non-neonatologists (p < 0.05). All respondents cited lack of experience as the main reason for feeling reluctant to place an UVC or IO access, the latter only being taken into consideration in term infants. CONCLUSIONS: UVC placement in the DR is rated more often difficult to use by non-neonatologists than by neonatologists, apparently related to lack of experience. IO access was only considered for resuscitating term infants due to lacking practice and missing approval for birth weights < 3000 g. Frequent training might improve these clinical skills.


Assuntos
Salas de Parto , Emergências , Feminino , Alemanha , Humanos , Lactente , Recém-Nascido , Infusões Intraósseas , Gravidez , Ressuscitação
10.
Neonatology ; : 1-10, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39019018

RESUMO

INTRODUCTION: The European guideline for treatment of respiratory distress syndrome recommends less invasive surfactant administration (LISA) as the preferred method of surfactant administration in spontaneously breathing preterm infants. However, there is limited evidence on practical aspects such as sedation and catheter types, leading to considerable variability between centers. METHODS: An anonymous online survey (www.soscisurvey.de) was sent to 164 tertiary neonatal intensive care units (NICUs) in Germany including 43 questions on practical aspects of LISA. RESULTS: Of 122 (74%) participating NICUs, 117 (96%) reported experience with LISA with 82% of those reporting LISA as their preferred method of surfactant administration. Indications for surfactant administration differed widely between NICUs. Most (89%) used FiO2-thresholds only or in combination with other criteria, such as Silverman score/signs of dyspnea (41%) or lung ultrasound findings (3%). Prophylactic surfactant was administered by 42%. Differences in use of LISA in extremely immature infants were reported (e.g., 36% did not perform LISA in infants below 24-26 weeks). Preferred drugs for sedation were (Es-)Ketamine, followed by Propofol and Midazolam. Minimum time interval between subsequent LISA procedures was 4 (2-6) h. Catheters specifically designed for LISA were used by most NICUs (69%). CONCLUSION: This survey shows that LISA is common practice in German NICUs, but with considerable variability in practical aspects. These data may serve as a guidance for NICUs that have not yet implemented LISA and might be helpful design clinical trials with the aim to standardize and/or optimize LISA.

11.
Arch Dis Child Fetal Neonatal Ed ; 109(4): 391-396, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38129130

RESUMO

OBJECTIVE: In extremely preterm infants, different target ranges for pulse oximeter saturation (SpO2) may affect mortality and morbidity. Thus, the impact of technical changes potentially affecting measurements should be assessed. We studied SpO2 readings from different sensors for systematic deviations. DESIGN: Single-centre, randomised, triple crossover study. SETTING: Tertiary neonatal intensive care unit. PATIENTS: 24 infants, born at <32 weeks' gestation, with current weight <1500 g and without right-to-left shunt via a patent ductus arteriosus. INTERVENTIONS: Simultaneous readings from three SpO2 sensors (Red Diamond (RD), Photoplethysmography (PPG), Low Noise Cabled Sensors (LNCS)) were logged at 0.5 Hz over 6 hour/infant and compared with LNCS as control using analysis of variance. Sensor position was randomly allocated and rotated every 2 hours. Seven different batches each were used. OUTCOMES: Primary outcome was the difference in SpO2 readings. Secondary outcomes were differences between sensors in the proportion of time within the SpO2-target range (90-95 (100)%). RESULTS: Mean gestational age at birth (±SD) was 274/7 (±23/7) weeks, postnatal age 20 (±20) days. 134 hours of recording were analysed. Mean SpO2 (±SD) was 94.0% (±3.8; LNCS) versus 92.2% (±4.0; RD; p<0.0001) and 94.5% (±3.9; PPG; p<0.0001), respectively. Mean SpO2 difference (95% CI) was -1.8% (-1.9 to -1.8; RD) and 0.5% (0.4 to 0.5; PPG). Proportion of time in target was significantly lower with RD sensors (84.8% vs 91.7%; p=0.0001) and similar with PPG sensors (91.1% vs 91.7%; p=0.63). CONCLUSION: There were systematic differences in SpO2 readings between RD sensors versus LNCS. These findings may impact mortality and morbidity of preterm infants, particularly when aiming for higher SpO2-target ranges (eg, 90-95%). TRIAL REGISTRATION NUMBER: DRKS00027285.


Assuntos
Estudos Cross-Over , Lactente Extremamente Prematuro , Oximetria , Humanos , Oximetria/métodos , Recém-Nascido , Feminino , Masculino , Unidades de Terapia Intensiva Neonatal , Idade Gestacional , Saturação de Oxigênio/fisiologia , Fotopletismografia/métodos
12.
Arch Dis Child Fetal Neonatal Ed ; 108(2): 170-175, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36038255

RESUMO

OBJECTIVE: Mechanisms of non-invasive high-frequency oscillatory ventilation (nHFOV) in preterm infants are unclear. We aimed to compare lung volume changes during apnoeas in preterm infants on nHFOV and nasal continuous positive airway pressure (nCPAP). METHODS: Analysis of electrical impedance tomography (EIT) data from a randomised crossover trial comparing nHFOV with nCPAP in preterm infants at 26-34 weeks postmenstrual age. EIT data were screened by two reviewers to identify apnoeas ≥10 s. End-expiratory lung impedance (EELI) and tidal volumes (VT) were calculated before and after apnoeas. Oxygen saturation (SpO2) and heart rate (HR) were extracted for 60 s after apnoeas. RESULTS: In 30 preterm infants, 213 apnoeas were identified. During apnoeas, oscillatory volumes were detectable during nHFOV. EELI decreased significantly during apnoeas (∆EELI nCPAP: -8.0 (-11.9 to -4.1) AU/kg, p<0.001; ∆EELI nHFOV: -3.4 (-6.5 to -0.3), p=0.03) but recovered over the first five breaths after apnoeas. Compared with before apnoeas, VT was increased for the first breath after apnoeas during nCPAP (∆VT: 7.5 (3.1 to 11.2) AU/kg, p=0.001). Falls in SpO2 and HR after apnoeas were greater during nCPAP than nHFOV (mean difference (95% CI): SpO2: 3.6% (2.7 to 4.6), p<0.001; HR: 15.9 bpm (13.4 to 18.5), p<0.001). CONCLUSION: Apnoeas were characterised by a significant decrease in EELI which was regained over the first breaths after apnoeas, partly mediated by a larger VT. Apnoeas were followed by a considerable drop in SpO2 and HR, particularly during nCPAP, leading to longer episodes of hypoxemia during nCPAP. Transmitted oscillations during nHFOV may explain these benefits. TRIAL REGISTRATION NUMBER: ACTRN12616001516471.


Assuntos
Apneia , Recém-Nascido Prematuro , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Lactente , Recém-Nascido , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Volume de Ventilação Pulmonar , Estudos Cross-Over
13.
BMJ ; 380: e072313, 2023 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-36693654

RESUMO

OBJECTIVE: To investigate whether monitoring of cerebral tissue oxygen saturation using near infrared spectroscopy in addition to routine monitoring combined with defined treatment guidelines during immediate transition and resuscitation increases survival without cerebral injury of premature infants compared with standard care alone. DESIGN: Multicentre, multinational, randomised controlled phase 3 trial. SETTING: 11 tertiary neonatal intensive care units in six countries in Europe and in Canada. PARTICIPANTS: 1121 pregnant women (<32 weeks' gestation) were screened prenatally. The primary outcome was analysed in 607 of 655 randomised preterm neonates: 304 neonates in the near infrared spectroscopy group and 303 in the control group. INTERVENTION: Preterm neonates were randomly assigned to either standard care (control group) or standard care plus monitoring of cerebral oxygen saturation with a dedicated treatment guideline (near infrared spectroscopy group) during immediate transition (first 15 minutes after birth) and resuscitation. MAIN OUTCOME MEASURE: The primary outcome, assessed using all cause mortality and serial cerebral ultrasonography, was a composite of survival without cerebral injury. Cerebral injury was defined as any intraventricular haemorrhage or cystic periventricular leukomalacia, or both, at term equivalent age or before discharge. RESULTS: Cerebral tissue oxygen saturation was similar in both groups. 252 (82.9%) out of 304 neonates (median gestational age 28.9 (interquartile range 26.9-30.6) weeks) in the near infrared spectroscopy group survived without cerebral injury compared with 238 (78.5%) out of 303 neonates (28.6 (26.6-30.6) weeks) in the control group (relative risk 1.06, 95% confidence interval 0.98 to 1.14). 28 neonates died (near infrared spectroscopy group 12 (4.0%) v control group 16 (5.3%): relative risk 0.75 (0.33 to 1.70). CONCLUSION: Monitoring of cerebral tissue oxygen saturation in combination with dedicated interventions in preterm neonates (<32 weeks' gestation) during immediate transition and resuscitation after birth did not result in substantially higher survival without cerebral injury compared with standard care alone. Survival without cerebral injury increased by 4.3% but was not statistically significant. TRIAL REGISTRATION: ClinicalTrials.gov NCT03166722.


Assuntos
Lesões Encefálicas , Oxigênio , Recém-Nascido , Lactente , Humanos , Feminino , Gravidez , Encéfalo/diagnóstico por imagem , Saturação de Oxigênio , Recém-Nascido Prematuro , Idade Gestacional
14.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 551-557, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35101993

RESUMO

INTRODUCTION: Non-invasive high-frequency oscillatory ventilation (nHFOV) is an extension of nasal continuous positive airway pressure (nCPAP) support in neonates. We aimed to compare global and regional distribution of lung volumes during nHFOV versus nCPAP. METHODS: In 30 preterm infants enrolled in a randomised crossover trial comparing nHFOV with nCPAP, electrical impedance tomography data were recorded in prone position. For each mode of respiratory support, four episodes of artefact-free tidal ventilation, each comprising 30 consecutive breaths, were extracted. Tidal volumes (VT) in 36 horizontal slices, indicators of ventilation homogeneity and end-expiratory lung impedance (EELI) for the whole lung and for four horizontal regions of interest (non-gravity-dependent to gravity-dependent; EELINGD, EELImidNGD, EELImidGD, EELIGD) were compared between nHFOV and nCPAP. Aeration homogeneity ratio (AHR) was determined by dividing aeration in non-gravity-dependent parts of the lung through gravity-dependent regions. MAIN RESULTS: Overall, 228 recordings were analysed. Relative VT was greater in all but the six most gravity-dependent lung slices during nCPAP (all p<0.05). Indicators of ventilation homogeneity were similar between nHFOV and nCPAP (all p>0.05). Aeration was increased during nHFOV (mean difference (95% CI)=0.4 (0.2 to 0.6) arbitrary units per kilogram (AU/kg), p=0.013), mainly due to an increase in non-gravity-dependent regions of the lung (∆EELINGD=6.9 (0.0 to 13.8) AU/kg, p=0.028; ∆EELImidNGD=6.8 (1.2 to 12.4) AU/kg, p=0.009). Aeration was more homogeneous during nHFOV compared with nCPAP (mean difference (95% CI) in AHR=0.01 (0.00 to 0.02), p=0.0014). CONCLUSION: Although regional ventilation was similar between nHFOV and nCPAP, end-expiratory lung volume was higher and aeration homogeneity was slightly improved during nHFOV. The aeration difference was greatest in non-gravity dependent regions, possibly due to the oscillatory pressure waveform. The clinical importance of these findings is still unclear.


Assuntos
Ventilação de Alta Frequência , Ventilação não Invasiva , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação de Alta Frequência/métodos , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente/métodos , Ventilação não Invasiva/métodos , Volume de Ventilação Pulmonar
15.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 508-512, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34862191

RESUMO

OBJECTIVE: We sought to determine the effect of stimulation during positive pressure ventilation (PPV) on the number of spontaneous breaths, exhaled tidal volume (VTe), mask leak and obstruction. DESIGN: Secondary analysis of a prospective, randomised trial comparing two face masks. SETTING: Single-centre delivery room study. PATIENTS: Newborn infants ≥34 weeks' gestation at birth. METHODS: Resuscitations were video recorded. Tactile stimulations during PPV were noted and the timing, duration and surface area of applied stimulus were recorded. Respiratory flow waveforms were evaluated to determine the number of spontaneous breaths, VTe, leak and obstruction. Variables were recorded throughout each tactile stimulation episode and compared with those recorded in the same time period immediately before stimulation. RESULTS: Twenty of 40 infants received tactile stimulation during PPV and we recorded 57 stimulations during PPV. During stimulation, the number of spontaneous breaths increased (median difference (IQR): 1 breath (0-3); padj<0.001) and VTe increased (0.5 mL/kg (-0.5 to 1.7), padj=0.028), whereas mask leak (0% (-20 to 1), padj=0.12) and percentage of obstructed inflations (0% (0-0), padj=0.14) did not change, compared with the period immediately prior to stimulation. Increased duration of stimulation (padj<0.001) and surface area of applied stimulus (padj=0.026) were associated with a larger increase in spontaneous breaths in response to tactile stimulation. CONCLUSIONS: Tactile stimulation during PPV was associated with an increase in the number of spontaneous breaths compared with immediately before stimulation without a change in mask leak and obstruction. These data inform the discussion on continuing stimulation during PPV in term infants. TRIAL REGISTRATION NUMBER: Australian and New Zealand Clinical Trial Registry (ACTRN12616000768493).


Assuntos
Recém-Nascido Prematuro , Máscaras , Austrália , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Respiração com Pressão Positiva , Estudos Prospectivos , Volume de Ventilação Pulmonar/fisiologia
16.
Arch Dis Child Fetal Neonatal Ed ; 106(4): 381-385, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33298407

RESUMO

OBJECTIVE: Application of a face mask may induce apnoea and bradycardia, possibly via the trigeminocardiac reflex (TCR). We aimed to describe rates of apnoea and bradycardia in term and late-preterm infants following facemask application during neonatal stabilisation and compare the effects of first facemask application with subsequent applications. DESIGN: Subgroup analysis of a prospective, randomised trial comparing two face masks. SETTING: Single-centre study in the delivery room PATIENTS: Infants>34 weeks gestational age at birth METHODS: Resuscitations were video recorded. Airway flow and pressure were measured using a flow sensor. The effect of first and subsequent facemask applications on spontaneously breathing infants were noted. When available, flow waveforms as well as heart rate (HR) were assessed 20 s before and 30 s after each facemask application. RESULTS: In total, 128 facemask applications were evaluated. In eleven percent of facemask applications infants stopped breathing. The first application was associated with a higher rate of apnoea than subsequent applications (29% vs 8%, OR (95% CI)=4.76 (1.41-16.67), p=0.012). On aggregate, there was no change in median HR over time. In the interventions associated with apnoea, HR dropped by 38bpm [median (IQR) at time of facemask application: 134bpm (134-150) vs 96bpm (94-102) 20 s after application; p=0.25] and recovered within 30 s. CONCLUSIONS: Facemask applications in term and late-preterm infants during neonatal stabilisation are associated with apnoea and this effect is more pronounced after the first compared with subsequent applications. Healthcare providers should be aware of the TCR and vigilant when applying a face mask to newborn infants. TRIAL REGISTRATION NUMBER: ACTRN12616000768493.


Assuntos
Apneia/etiologia , Bradicardia/etiologia , Máscaras/efeitos adversos , Reflexo Trigêmino-Cardíaco/fisiologia , Apneia/fisiopatologia , Bradicardia/fisiopatologia , Feminino , Idade Gestacional , Frequência Cardíaca , Humanos , Recém-Nascido , Recém-Nascido Prematuro/fisiologia , Masculino , Estudos Prospectivos , Gravação de Videoteipe
17.
Resuscitation ; 167: 317-325, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34302924

RESUMO

AIM: To determine whether the use of a respiratory function monitor (RFM) during PPV of extremely preterm infants at birth, compared with no RFM, leads to an increase in percentage of inflations with an expiratory tidal volume (Vte) within a predefined target range. METHODS: Unmasked, randomised clinical trial conducted October 2013 - May 2019 in 7 neonatal intensive care units in 6 countries. Very preterm infants (24-27 weeks of gestation) receiving PPV at birth were randomised to have a RFM screen visible or not. The primary outcome was the median proportion of inflations during manual PPV (face mask or intubated) within the target range (Vte 4-8 mL/kg). There were 42 other prespecified monitor measurements and clinical outcomes. RESULTS: Among 288 infants randomised (median (IQR) gestational age 26+2 (25+3-27+1) weeks), a total number of 51,352 inflations were analysed. The median (IQR) percentage of inflations within the target range in the RFM visible group was 30.0 (18.0-42.2)% vs 30.2 (14.8-43.1)% in the RFM non-visible group (p = 0.721). There were no differences in other respiratory function measurements, oxygen saturation, heart rate or FiO2. There were no differences in clinical outcomes, except for the incidence of intraventricular haemorrhage (all grades) and/or cystic periventricular leukomalacia (visible RFM: 26.7% vs non-visible RFM: 39.0%; RR 0.71 (0.68-0.97); p = 0.028). CONCLUSION: In very preterm infants receiving PPV at birth, the use of a RFM, compared to no RFM as guidance for tidal volume delivery, did not increase the percentage of inflations in a predefined target range. TRIAL REGISTRATION: Dutch Trial Register NTR4104, clinicaltrials.gov NCT03256578.


Assuntos
Respiração com Pressão Positiva , Ressuscitação , Humanos , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Monitorização Fisiológica , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa