Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Infect Dis ; 24(1): 190, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350885

RESUMO

BACKGROUND: The World Health Organization endorsed Truenat MTB rapid molecular assay in 2020 and recommended additional in-country evaluation studies before uptake. We evaluated the accuracy and operational feasibility of Truenat MTB assay (Truenat) in comparison with GeneXpert Ultra and culture. METHODS: In a cross-sectional study of 250 presumptive TB patients, participants were requested to provide a sputum sample on the day of their visit to the clinic. The sputum sample was homogenized and a portion was tested using GeneXpert Ultra as per the routine standard procedure and the other portion was tested using Truenat assay at the clinic laboratory. The second sample portion was processed for Concentrated Fluorescent smear Microscopy (CFM), LJ, and MGIT cultures. Truenat sensitivity and specificity were compared to GeneXpert Ultra and culture. Test performance characteristics and operational feasibility assessment data through interview of the study laboratory staff were also collected and summarized as proportions and percentages. RESULTS: Of the 250 participants recruited in the study, the sensitivity and specificity of Truenat was n/N (%, 95%CI); 66/82 (80.5, 70.2-88.4) and 156/159 (98.1, 94.5-99.6) when compared with Ultra, 50/64 (89.3, 66.0-87.4) and 166/180 (92.2, 87.2-95.6) when compared with LJ, 58/71 (81.7,70.7-89.8) and 131/138 (94.9, 89.8-97.9) when compared to MGIT culture and 59/73 (80.8, 69.9-89.1) and 159/169 (94.1,89.3-97.1) when compared to LJ and/or MGIT culture. The sensitivity of Truenat was lower, 14/23 (60.9, 40.6-82.8) among smear-negative compared to 45/50 (90.0, 78.1-96.6) among smear-positive participants but not different by HIV status. There were no special training needs especially among laboratory personnel with previous GeneXpert /molecular test experience, 19/242 (7.8%) error/invalid, and 12 (17,4%) uninterpretable/indeterminate results mainly for rifampicin resistance determination. However, there were 3 (3.5%) of GeneXpert Ultra indeterminate results. CONCLUSION: Among presumptive TB patients in Uganda, the Truenat assay has high sensitivity and specificity. The Truenat assay has acceptable operational feasibility attributes when compared with the GeneXpert Assay.


Assuntos
Mycobacterium tuberculosis , Tuberculose Pulmonar , Humanos , Rifampina , Mycobacterium tuberculosis/genética , Uganda , Estudos Transversais , Escarro , Tuberculose Pulmonar/diagnóstico , Sensibilidade e Especificidade
2.
PLoS One ; 18(8): e0284545, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37590288

RESUMO

BACKGROUND: Drug-Resistant Tuberculosis (DR-TB) is one of the major challenges to TB control. DESIGN AND METHODS: This was a blinded, laboratory-based cross-sectional study using sputum samples or culture isolates. Samples were from patients with rifampicin-resistant-TB and/or with high risk for isoniazid (INH) resistance and/or 2nd line fluoroquinolones (FQ) and injectable agents (IAs). The diagnostic accuracy of the Xpert® MTB/XDR test was compared to MGIT960 and the Hain Genotype® MTBDRplus and MDRsl assays (LPA) as reference DST methods. Factors for laboratory uptake of the Xpert® MTB/XDR test were also evaluated. RESULTS: Of the 100 stored sputum samples included in this study, 65/99 (65.6%) were resistant to INH, 5/100 (5.0%) were resistant to FQ and none were resistant to IAs using MGIT960. The sensitivity and specificity, n (%; 95% Confidence Interval, CI) of Xpert® MTB/XDR test for; INH was 58 (89.2; 79.1-95.5) and 30 (88.2; 72.5-96.6) and for FQ; 4 (80.0; 28.3-99.4) and 95 (100; 96.2-100), respectively. Using LPA as a reference standard, a total of 52/98 (53.1%) were resistant to INH, 3/100 (3.0%) to FQ, and none to IA. The sensitivity and specificity, n (%; 95%CI) of Xpert® MTB/XDR test compared to LPA for; INH was 50 (96.1; 86.7-99.5) and 34 (74.0; 58.8-85.7) for FQ 3 (100; 29.2-100) and 96 (99.0; 94.3-99.9) respectively. The factors for laboratory uptake and roll-out of the Xpert® MTB/XDR test included: no training needed for technicians with, and one day for those without, previous Xpert-ultra experience, recording and reporting needs were not different from those of Xpert-ultra, the error rate was 4/100 (4%), one (1%) indeterminate rate and test turn-around-time were 1hr/45 minutes. CONCLUSION: There is high sensitivity and specificity of Xpert® MTB/XDR test for isoniazid and fluoroquinolones. There are acceptable Xpert® MTB/XDR test attributes for the test uptake and roll-out.


Assuntos
Mycobacterium tuberculosis , Humanos , Mycobacterium tuberculosis/genética , Uganda , Estudos Transversais , Isoniazida/farmacologia , Fluoroquinolonas/farmacologia
3.
medRxiv ; 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37066316

RESUMO

Background: Drug-Resistant Tuberculosis (DR-TB) is one of the key challenges toward TB control. There is an urgent need for rapid and accurate drug susceptibility tests (DST) for the most commonly used 1 st and 2 nd line TB drugs. Design and Methods: In a blinded, laboratory-based cross-sectional study, we set out to validate the performance of the Xpert ® MTB/XDR test for DST of M. tuberculosis . Sputum samples or culture isolates collected between January 2020 and December 2021 from patients with rifampicin resistance -TB and/or with higher suspicion index for isoniazid (INH) resistance and/or 2 nd line fluoroquinolones (FQ) and injectable agents (IAs) were tested using the Xpert ® MTB/XDR test from 11/September 2021 to 26/May /2022. Diagnostic accuracy and factors for laboratory uptake of Xpert ® MTB/XDR test were compared to MGIT960 and the Hain Genotype® MTBDR plus and MDRsl assays (LPA) as reference DST methods. Results: A total of 100 stored sputum samples were included in this study. Of the samples tested using MGIT960, 65/99 (65.6%) were resistant to INH, 5/100 (5.0%) resistant to FQ and none were resistant to IAs. The sensitivity and specificity, n (%; 95%Confidence Interval, CI) of Xpert ® MTB/XDR test for; INH were 58 (89.2; 79.1-95.5) and 30 (88.2; 72.5-96.6), FQ; 4 (80.0; 28.3-99.4) and 95 (100; 96.2-100), respectively. The specificity for AIs was 100 (100; 96.3-100). Using LPA as a reference standard, a total of 52/98 (53.1%) were resistant to INH, 3/100 (3.0%) to FQ, and none to IA. The sensitivity and specificity, n (%; 95%CI) of Xpert ® MTB/XDR test compared to LPA for; INH was 50 (96.1; 86.7-99.5) and 34 (74.0; 58.8-85.7) and FQ 3 (100; 29.2-100) and 96 (99.0; 94.3-99.9) respectively. The specificity of IAs was 96 (100; 96.2-100). The factors for laboratory uptake and roll-out included; no training needed for technicians with previous Xpert-ultra experience and one day for those without, recording and reporting needs were not different from those of Xpert ultra, the error rate was 4/100 (4%), no uninterpretable results reported, test turn-around-time was 1hr/45 minutes and workflow similar to that of the Xpert-ultra test. Conclusion: There is high sensitivity and specificity of Xpert ® MTB/XDR test for isoniazid, fluoroquinolones, and Injectable agents. There are acceptable Xpert ® MTB/XDR test attributes for test uptake and roll-out.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa