Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
1.
J Comput Assist Tomogr ; 48(2): 323-333, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38013237

RESUMO

OBJECTIVE: Our study objective was to explore the additional value of dual-energy CT (DECT) material decomposition for squamous cell carcinoma of the head and neck (SCCHN) survival prognostication. METHODS: A group of 50 SCCHN patients (male, 37; female, 13; mean age, 63.6 ± 10.82 years) with baseline head and neck DECT between September 2014 and August 2020 were retrospectively included. Primary tumors were segmented, radiomics features were extracted, and DECT material decomposition was performed. We used independent train and validation datasets with cross-validation and 100 independent iterations to identify prognostic signatures applying elastic net (EN) and random survival forest (RSF). Features were ranked and intercorrelated according to their prognostic importance. We benchmarked the models against clinical parameters. Intraclass correlation coefficients were used to analyze the interreader variation. RESULTS: The exclusively radiomics-trained models achieved similar ( P = 0.947) prognostic performance of area under the curve (AUC) = 0.784 (95% confidence interval [CI], 0.775-0.812) (EN) and AUC = 0.785 (95% CI, 0.759-0.812) (RSF). The additional application of DECT material decomposition did not improve the model's performance (EN, P = 0.594; RSF, P = 0.198). In the clinical benchmark, the top averaged AUC value of 0.643 (95% CI, 0.611-0.675) was inferior to the quantitative imaging-biomarker models ( P < 0.001). A combined imaging and clinical model did not improve the imaging-based models ( P > 0.101). Shape features revealed high prognostic importance. CONCLUSIONS: Radiomics AI applications may be used for SCCHN survival prognostication, but the spectral information of DECT material decomposition did not improve the model's performance in our preliminary investigation.


Assuntos
Neoplasias de Cabeça e Pescoço , Radiômica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem
2.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872126

RESUMO

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Assuntos
Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Osso Temporal , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Idoso , Adulto , Implante Coclear/métodos
3.
Eur Arch Otorhinolaryngol ; 281(7): 3569-3575, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38324057

RESUMO

PURPOSE: The aim of the presented study was to compare the audiological benefit achieved in cochlear implant (CI) patients who, in principle, could still have been treated with an active middle ear implant (AMEI) with a group of AMEI users. METHODS: Results of 20 CI patients with a pure-tone average (PTA) of 70 dB HL prior to surgery were compared with a group of 12 subjects treated with a Vibrant Soundbridge (VSB). Pre-surgical comparison included PTA for air conduction and bone conduction, maximum speech recognition score for monosyllabic words (WRSmax), and aided monosyllabic word recognition at 65 dB SPL. One year after surgery, aided monosyllabic speech recognition score at 65 dB SPL was compared. RESULTS: Mean PTA for air conduction in the VSB group was significantly lower than in the CI group (4.8 dB, Z = - 2.011, p < 0.05). Mean PTA for bone conduction in the VSB group was also significantly lower than in the CI group (23.4 dB, Z = - 4.673, p < 0.001). WRSmax in the VSB group was significantly better than in the CI group (40.7%, Z = - 3.705, p < 0.001). One year after treatment, there was no significant difference in aided speech perception in quiet between both subject groups. CONCLUSION: Comparison of the two methods showed equivalent results for both treatments in subjects with a borderline indication. Not only pure-tone audiometry results but, particularly, speech perception scores pre-surgery should be taken into account in preoperative counseling.


Assuntos
Audiometria de Tons Puros , Implantes Cocleares , Percepção da Fala , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Adulto , Percepção da Fala/fisiologia , Idoso , Prótese Ossicular , Condução Óssea/fisiologia , Resultado do Tratamento , Aconselhamento , Implante Coclear/métodos , Cuidados Pré-Operatórios/métodos , Tomada de Decisão Clínica
4.
Eur Arch Otorhinolaryngol ; 281(3): 1231-1242, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37707616

RESUMO

PURPOSE: Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI). METHODS: Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications. If pain was experienced, it was assessed using a visual analog scale (1-10). RESULTS: MRI was performed without adverse events in 37.8% of cases. Magnet dislocation requiring surgical revision occurred in 2% of cases. Pain was reported in 86% of cases, often due to the tightness of the dressing. Patients with rotating, MRI-compatible magnets reported significantly less pain than participants with older-generation implants. In 11% of cases, the MRI was discontinued. CONCLUSION: Serious complications during MRI in cochlear implant patients are rare. Pain is the most common adverse event, probably mainly due to the tight bandage required by most implant types. With newer generations of magnets, these patients experience less pain, no dislocation of the magnets, and no need for bandaging. Although magnet dislocation cannot be completely prevented in older generations of implants, it appears to be reduced by good patient management, which recommends examination under the guidance of physicians trained in the use of hearing implants.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Idoso , Implantes Cocleares/efeitos adversos , Estudos Prospectivos , Implante Coclear/efeitos adversos , Dor/etiologia , Imageamento por Ressonância Magnética/efeitos adversos , Imãs
5.
Eur Arch Otorhinolaryngol ; 281(7): 3453-3460, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38353767

RESUMO

PURPOSE: In recent years, the number of elderly cochlear implant (CI) candidates is continuously rising. In addition to the audiological improvement, other positive effects of CI treatment can also be observed in clinical routine. The "quality of life" as a parameter of success directly experienced by the patient is increasingly becoming the focus of clinical research. Although there are already clear indications of a rapid and significant improvement in quality of life, there is still a lack of systematic, prospectively collected longitudinal long-term data in patients over the age of 65. METHODS: This prospective longitudinal observational study included 31 patients between the age of 71 and 92 years who had first been treated unilaterally with a CI 6 years ago. In addition to free-field monosyllable recognition, quality of life was assessed using the World Health Organization Quality-of-Life Scale-old (WHOQL-OLD). The results were compared with the data from our previous study, in which we focused on the short- and medium-term effects on quality of life. In both studies, the same patient population was examined. In addition, these study data were compared with an age-matched average population. RESULTS: In speech recognition, there was no significant change from the control 6 months postoperatively compared with the results 6 years postoperatively. No significant changes occurred in the total quality of life score or any of the other six facets of quality of life when comparing the results 6 months postoperatively with the results 6 years postoperatively. In "Social participation", the CI patients even exceed the values of the age-matched average population 6 years after treatment. CONCLUSION: Improvement in the quality of life and especially in social participation appears stable over many years in elderly patients after hearing rehabilitation with a CI.


Assuntos
Implante Coclear , Implantes Cocleares , Qualidade de Vida , Participação Social , Humanos , Idoso , Masculino , Feminino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Implante Coclear/psicologia , Estudos Longitudinais , Resultado do Tratamento , Percepção da Fala
6.
Artigo em Inglês | MEDLINE | ID: mdl-38705897

RESUMO

INTRODUCTION: The treatment of patients with a cochlear implant (CI) is usually an elective, complex and interdisciplinary process. As an important source of information, patients often access the internet prior to treatment. The quality of internet-based information regarding thematic coverage has not yet been analysed in detail. Therefore, the aim of this study was to analyse the information on CI care available on the internet regarding its thematic coverage and readability. MATERIAL METHODS: Eight search phrases related to CI care were defined as part of the study. A checklist for completeness of thematic coverage was then created for each search phrase. The current German CI clinical practice guideline and the white paper on CI care in Germany were used as a basis. As a further parameter, readability was assessed using Flesch Reading Ease Scores. The search phrases were used for an internet search with Google. The first ten results were then analysed with regard to thematic coverage, readability and the provider of the website. RESULTS: A total of 80 websites were identified, which were set up by 54 different providers (16 providers were found in multiple entries) from eight different provider groups. The average completeness of thematic coverage was 41.6 ± 28.2%. Readability according to the Flesch Reading Ease Score was categorised as "hard to read" on average (34.7 ± 14.2 points, range: 0-72). There was a negative statistically significant correlation between the thematic coverage of content and readability (Spearman's rank correlation: r = - 0.413, p = 0.00014). The completeness of thematic coverage of information on CI care available on the internet was highly heterogeneous and had a significant negative correlation with the readability. This result should be taken into account by both the providers of internet information and by patients when using internet-based information on CI care and help to further improve the quality of web-based information.

7.
HNO ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775829

RESUMO

The sensitivity and the complexity of the human inner ear in conjunction with the lack of regenerative capacity are the main reasons for hearing loss and tinnitus. Progress in the development of protective and regenerative therapies for the inner ear often failed in the past not least due to the fact that no suitable model systems for cell biological and pharmacological in vitro studies were available. A novel technology for creating "mini-organs", so-called organoids, could solve this problem and has now also reached inner ear research. It makes it possible to produce inner ear organoids from cochlear stem/progenitor cells, embryonic and induced pluripotent stem cells that mimic the structural characteristics and functional properties of the natural inner ear. This review focuses on the biological basis of these inner ear organoids, the current state of research and the promising prospects that are now opening up for basic and translational inner ear research.

8.
HNO ; 72(Suppl 1): 10-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552279

RESUMO

BACKGROUND: Although good speech perception in quiet is achievable with cochlear implants (CIs), speech perception in noise is severely impaired compared to normal hearing (NH). In the case of a bimodal CI fitting with a hearing aid (HA) in the opposite ear, the amount of residual acoustic hearing influences speech perception in noise. OBJECTIVE: The aim of this work was to investigate speech perception in noise in a group of bimodal CI users and compare the results to age-matched HA users and people without subjective hearing loss, as well as with a young NH group. MATERIALS AND METHODS: Study participants comprised 19 bimodal CI users, 39 HA users, and 40 subjectively NH subjects in the age group 60-90 years and 14 young NH subjects. Speech reception thresholds (SRTs) in noise were adaptively measured using the Oldenburg Sentence Test for the two spatial test conditions S0N0 (speech and noise from the front) and multisource-noise field (MSNF; speech from the front, four spatially distributed noise sources) in continuous noise of the Oldenburg Sentence Test (Ol-noise) and amplitude-modulated Fastl noise (Fastl-noise). RESULTS: With increasing hearing loss, the median SRT worsened significantly in all conditions. In test condition S0N0, the SRT of the CI group was 5.6 dB worse in Ol-noise than in the young NH group (mean age 26.4 years) and 22.5 dB worse in Fastl-noise; in MSNF, the differences were 6.6 dB (Ol-noise) and 17.3 dB (Fastl-noise), respectively. In the young NH group, median SRT in condition S0N0 improved by 11 dB due to gap listening; in the older NH group, SRTs improved by only 3.1 dB. In the HA and bimodal CI groups there was no gap listening effect and SRTs in Fastl-noise were even worse than in Ol-noise. CONCLUSION: With increasing hearing loss, speech perception in modulated noise is even more impaired than in continuous noise.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Ruído , Perda Auditiva/diagnóstico
9.
HNO ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630310

RESUMO

BACKGROUND: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined. MATERIALS AND METHODS: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation. Patients with a significantly longer waiting time were included in the control group (CG, n = 21). In addition to the start and duration of rehabilitation, the speech intelligibility achieved with CI was recorded at different timepoints within a 12-month period. In addition, questionnaires were used to assess the effort of fitting the CI processor and the patients' satisfaction with the outcome as well as the timing of the start of rehabilitation. RESULTS: Median waiting time between implantation and start of rehabilitation was 14 days in the IG and 106 days in the CG; 92.6% of IG patients were able to start rehabilitation within 14 days. The effect of rehabilitation in the IG was 35 and in the CG 25 percentage points (Freiburg monosyllabic test). After 6 and 12 months of CI use, both groups showed comparable results in the test condition in quiet (IG/CG 6 months: 70%/70%; 12 months: 70%/60%, Freiburg monosyllabic test) and in noise (IG/CG 6 months: -1.1 dB SNR/-0.85 dB SNR; 12 months: -0.65 dB SNR/+0.3 dB SNR, Oldenburg sentence test). Hearing quality assessment scores collected by SSQ (Speech, Spatial and Qualities of Hearing Scale) questionnaire showed better scores in the IG at 6 months, which converged to CG scores at 12 months. The IG was significantly more satisfied with the timing of the start of rehab than the CG. All other data obtained from questionnaires showed no differences between the two groups. CONCLUSION: A very early start of inpatient rehabilitation after cochlear implantation was successfully implemented. The rehabilitation was completed within 7 weeks of CI surgery. Comparison of speech recognition test results before and after rehabilitation showed a significant improvement. A clear rehabilitation effect can therefore be demonstrated. Inclusion of CI rehabilitation in the German catalog of follow-up treatments is thus scientifically justified and therefore strongly recommended.

10.
HNO ; 72(6): 412-422, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38358482

RESUMO

BACKGROUND: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined. MATERIALS AND METHODS: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation. Patients with a significantly longer waiting time were included in the control group (CG, n = 21). In addition to the start and duration of rehabilitation, the speech intelligibility achieved with CI was recorded at different timepoints within a 12-month period. In addition, questionnaires were used to assess the effort of fitting the CI processor and the patients' satisfaction with the outcome as well as the timing of the start of rehabilitation. RESULTS: Median waiting time between implantation and start of rehabilitation was 14 days in the IG and 106 days in the CG; 92.6% of IG patients were able to start rehabilitation within 14 days. The effect of rehabilitation in the IG was 35 and in the CG 25 percentage points (Freiburg monosyllabic test). After 6 and 12 months of CI use, both groups showed comparable results in the test condition in quiet (IG/CG 6 months: 70%/70%; 12 months: 70%/60%, Freiburg monosyllabic test) and in noise (IG/CG 6 months: -1.1-0.85 dB SNR; 12 months: -0.65 dB SNR/0.3 dB SNR, Oldenburg sentence test). Hearing quality assessment scores collected by SSQ (Speech, Spatial and Qualities of Hearing Scale) questionnaire showed better scores in the IG at 6 months, which converged to CG scores at 12 months. The IG was significantly more satisfied with the timing of the start of rehab than the CG. All other data obtained from questionnaires showed no differences between the two groups. CONCLUSION: A very early start of inpatient rehabilitation after cochlear implantation was successfully implemented. The rehabilitation was completed within 7 weeks of CI surgery. Comparison of speech recognition test results before and after rehabilitation showed a significant improvement. A clear rehabilitation effect can therefore be demonstrated. Inclusion of CI rehabilitation in the German catalog of follow-up treatments is thus scientifically justified and therefore strongly recommended.


Assuntos
Implante Coclear , Estudos de Viabilidade , Humanos , Alemanha , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Implante Coclear/reabilitação , Adulto , Assistência ao Convalescente/métodos , Implantes Cocleares , Idoso , Satisfação do Paciente , Adulto Jovem , Hospitalização , Surdez/reabilitação , Correção de Deficiência Auditiva/métodos
11.
Laryngorhinootologie ; 2024 Jun 06.
Artigo em Alemão | MEDLINE | ID: mdl-38843816

RESUMO

BACKGROUND: Tinnitus is one of the most common otologic comorbidities, particularly in older patients with severe hearing loss or deafness. Cochlear implants (CI) have been used for hearing rehabilitation more and more successfully in elderly patients and CI treatment is performed in Germany without an age limit. The aim of this follow-up study was to assess the tinnitus burden in the long-term follow-up of elderly patients with hearing rehabilitation using CI. MATERIAL AND METHODS: This prospective longitudinal study included 15 patients between 72 and 92 years of age with preoperative tinnitus who had been treated unilaterally with a CI for the first time about six years ago. Monosyllabic speech understanding and tinnitus burden were assessed using the Mini-Tinnitus Questionnaire. The results were compared with our previous study 24, focusing on the first six months. RESULTS: Six years postoperatively, there was a nonsignificant increase in monosyllabic understanding to 61.7 ± 26.3%, compared with the results six months postoperatively (p = 0.069). The burden of tinnitus showed a stable low mean of 3.9 ± 3.6 points six years postoperatively, compared with the six-month control (p = 0.689) and significantly reduced compared to the preoperative status with 6.9 ± 6.5 points (p = 0.016). CONCLUSION: Hearing rehabilitation by using CI leads to a stable improvement of monosyllabic discrimination in elderly people as well as to a stable reduction of tinnitus burden over years.

12.
BMC Med Imaging ; 23(1): 71, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268876

RESUMO

BACKGROUND: Treatment plans for squamous cell carcinoma of the head and neck (SCCHN) are individually decided in tumor board meetings but some treatment decision-steps lack objective prognostic estimates. Our purpose was to explore the potential of radiomics for SCCHN therapy-specific survival prognostication and to increase the models' interpretability by ranking the features based on their predictive importance. METHODS: We included 157 SCCHN patients (male, 119; female, 38; mean age, 64.39 ± 10.71 years) with baseline head and neck CT between 09/2014 and 08/2020 in this retrospective study. Patients were stratified according to their treatment. Using independent training and test datasets with cross-validation and 100 iterations, we identified, ranked and inter-correlated prognostic signatures using elastic net (EN) and random survival forest (RSF). We benchmarked the models against clinical parameters. Inter-reader variation was analyzed using intraclass-correlation coefficients (ICC). RESULTS: EN and RSF achieved top prognostication performances of AUC = 0.795 (95% CI 0.767-0.822) and AUC = 0.811 (95% CI 0.782-0.839). RSF prognostication slightly outperformed the EN for the complete (ΔAUC 0.035, p = 0.002) and radiochemotherapy (ΔAUC 0.092, p < 0.001) cohort. RSF was superior to most clinical benchmarking (p ≤ 0.006). The inter-reader correlation was moderate or high for all features classes (ICC ≥ 0.77 (± 0.19)). Shape features had the highest prognostic importance, followed by texture features. CONCLUSIONS: EN and RSF built on radiomics features may be used for survival prognostication. The prognostically leading features may vary between treatment subgroups. This warrants further validation to potentially aid clinical treatment decision making in the future.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Estudos Retrospectivos , Prognóstico , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia
13.
Eur Arch Otorhinolaryngol ; 280(9): 3977-3985, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36943438

RESUMO

PURPOSE: The cochlear implant (CI) is a standard treatment for patients with severe to profound hearing loss. In recent years, early device activation of the sound processor after 2-3 days following surgery has been established. The aim of this study is to evaluate the residual hearing of CI patients with substantial preoperative low-frequency hearing after early device activation over a period of 12 months. METHODS: Results were compared between an early fitted group (EF) with device activation to less than 15 days after CI surgery and a control group (CG) with device activation after 3-6 weeks. In total, 57 patients were divided into EF group (n = 32), and CG (n = 25). Low-frequency residual hearing and speech recognition in quiet and in noise were compared over an observation period of 12 months. RESULTS: No significant difference (p > 0.05) in the residual low-frequency hearing PTAlow between EF and CG was found, neither preoperatively (EF 33.2 dB HL/CG 35.0 dB HL), nor postoperatively (EF 46.8 dB HL/CG 46.2 dB HL). In both groups, postoperative residual hearing decreased compared to preoperative and remained stable within the first year after CI surgery. Furthermore, both groups showed no significant differences (p > 0.05) in speech recognition in quiet and in noise within the first year. CONCLUSION: Early device activation is feasible in CI patients with preoperative low-frequency residual hearing, without an additional effect on postoperative hearing preservation.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Implante Coclear/métodos , Percepção da Fala/fisiologia , Audição/fisiologia , Testes Auditivos , Resultado do Tratamento
14.
Eur Arch Otorhinolaryngol ; 280(12): 5241-5249, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37219685

RESUMO

PURPOSE: This study investigated whether an interaural delay, e.g. caused by the processing latency of a hearing device, can affect sensitivity to interaural level differences (ILDs) in normal hearing subjects or cochlear implant (CI) users with contralateral normal hearing (SSD-CI). METHODS: Sensitivity to ILD was measured in 10 SSD-CI subjects and in 24 normal hearing subjects. The stimulus was a noise burst presented via headphones and via a direct cable connection (CI). ILD sensitivity was measured for different interaural delays in the range induced by hearing devices. ILD sensitivity was correlated with results obtained in a sound localization task using seven loudspeakers in the frontal horizontal plane. RESULTS: In the normal hearing subjects the sensitivity to interaural level differences deteriorated significantly with increasing interaural delays. In the CI group, no significant effect of interaural delays on ILD sensitivity was found. The NH subjects were significantly more sensitive to ILDs. The mean localization error in the CI group was 10.8° higher than in the normal hearing group. No correlation between sound localization ability and ILD sensitivity was found. CONCLUSION: Interaural delays influence the perception of ILDs. For normal hearing subjects a significant decrement in sensitivity to ILD was measured. The effect could not be confirmed in the tested SSD-CI group, probably due to a small subject group with large variations. The temporal matching of the two sides may be beneficial for ILD processing and thus sound localization for CI patients. However, further studies are needed for verification.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Percepção da Fala , Humanos , Ruído
15.
Eur Arch Otorhinolaryngol ; 280(10): 4445-4454, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37191916

RESUMO

PURPOSE: Bilateral cochlear implantation is an effective treatment for patients with bilateral profound hearing loss. In contrast to children, adults mostly choose a sequential surgery. This study addresses whether simultaneous bilateral CI is associated with higher rates of complications compared to sequential implantation. METHODS: 169 bilateral CI surgeries were analyzed retrospectively. 34 of the patients were implanted simultaneously (group 1), whereas 135 patients were implanted sequentially (group 2). The duration of surgery, the incidence of minor and major complications and the duration of hospitalization of both groups were compared. RESULTS: In group 1, the total operating room time was significantly shorter. The incidences of minor and major surgical complications showed no statistically significant differences. A fatal non-surgical complication in group 1 was particularly extensively reappraised without evidence of a causal relationship to the chosen mode of care. The duration of hospitalization was 0.7 days longer than in unilateral implantation but 2.8 days shorter than the combined two hospital stays in group 2. CONCLUSION: In the synopsis of all considered complications and complication-relevant factors, equivalence of simultaneous and sequential cochlear implantation in adults in terms of safety was found. However, potential side effects related to longer surgical time in simultaneous surgery must be considered individually. Careful patient selection with special consideration to existing comorbidities and preoperative anesthesiologic evaluation is essential.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Criança , Humanos , Adulto , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Implantes Cocleares/efeitos adversos , Estudos Retrospectivos , Audição , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Bilateral/cirurgia , Resultado do Tratamento
16.
HNO ; 71(11): 702-707, 2023 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-37845538

RESUMO

The sensitivity and the complexity of the human inner ear in conjunction with the lack of regenerative capacity are the main reasons for hearing loss and tinnitus. Progress in the development of protective and regenerative therapies for the inner ear often failed in the past not least due to the fact that no suitable model systems for cell biological and pharmacological in vitro studies were available. A novel technology for creating "mini-organs", so-called organoids, could solve this problem and has now also reached inner ear research. It makes it possible to produce inner ear organoids from cochlear stem/progenitor cells, embryonic and induced pluripotent stem cells that mimic the structural characteristics and functional properties of the natural inner ear. This review focuses on the biological basis of these inner ear organoids, the current state of research and the promising prospects that are now opening up for basic and translational inner ear research.


Assuntos
Surdez , Orelha Interna , Perda Auditiva , Humanos , Perda Auditiva/terapia , Organoides , Cóclea , Diferenciação Celular
17.
HNO ; 71(8): 487-493, 2023 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-37395783

RESUMO

BACKGROUND: Although good speech perception in quiet is achievable with cochlear implants (CIs), speech perception in noise is severely impaired compared to normal hearing (NH). In the case of a bimodal CI fitting with a hearing aid (HA) in the opposite ear, the amount of residual acoustic hearing influences speech perception in noise. OBJECTIVE: The aim of this work was to investigate speech perception in noise in a group of bimodal CI users and compare the results to age-matched HA users and people without subjective hearing loss, as well as with a young NH group. MATERIALS AND METHODS: Study participants comprised 19 bimodal CI users, 39 HA users, and 40 subjectively NH subjects in the age group 60-90 years and 14 young NH subjects. Speech reception thresholds (SRTs) in noise were adaptively measured using the Oldenburg Sentence Test for the two spatial test conditions S0N0 (speech and noise from the front) and multisource-noise field (MSNF; speech from the front, four spatially distributed noise sources) in continuous noise of the Oldenburg Sentence Test (Ol-noise) and amplitude-modulated Fastl noise (Fastl-noise). RESULTS: With increasing hearing loss, the median SRT worsened significantly in all conditions. In test condition S0N0, the SRT of the CI group was 5.6 dB worse in Ol-noise than in the young NH group (mean age 26.4 years) and 22.5 dB worse in Fastl-noise; in MSNF, the differences were 6.6 dB (Ol-noise) and 17.3 dB (Fastl-noise), respectively. In the young NH group, median SRT in condition S0N0 improved by 11 dB due to gap listening; in the older NH group, SRTs improved by only 3.1 dB. In the HA and bimodal CI groups there was no gap listening effect and SRTs in Fastl-noise were even worse than in Ol-noise. CONCLUSION: With increasing hearing loss, speech perception in modulated noise is even more impaired than in continuous noise.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Ruído , Perda Auditiva/diagnóstico
18.
Laryngorhinootologie ; 102(6): 412-415, 2023 06.
Artigo em Alemão | MEDLINE | ID: mdl-37267964

RESUMO

The 2018 template for otorhinolaryngology specialist training of the German Medical Association is increasingly implemented by the federal associations. In this regard, the German Society recommended an otorhinolaryngology resident training plan for Otorhinolaryngology, Head and Neck Surgery (DGHNO-KHC) together with the Professional Association of German Otorhinolaryngologists as a suggested guideline for the federal medical associations. In this context, the state medical associations currently work on criteria on the basis of which otorhinolaryngologists and their training institutions can be granted authority for such a certified otorhinolaryngology resident training program.The DGHNO-KHC last made recommendations for the granting of authorizations for specialist training in otorhinolaryngology in 1999. Many contents have changed as a result of the 2018 model specialist training regulations. Therefore, a scientifically formulated proposal for the granting of continuing education authorizations is herewith provided as recommendation to the federal state medical associations.


Assuntos
Otolaringologia , Humanos , Otolaringologia/educação , Especialização , Alemanha
19.
Eur Radiol ; 32(1): 234-242, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34226991

RESUMO

OBJECTIVES: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. METHODS: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. RESULTS: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients' age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. CONCLUSION: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors. KEY POINTS: • Post-operative radiological assessment of the mastoid facial canal and the positional relationship with the CI electrode provide no predictor of post-cochlear implant facial nerve stimulation. • Radiological detection of extracochlear electrode contacts and the previous clinical history of meningitis/encephalitis are two important risk factors for postoperative facial nerve stimulation in cochlear implant patients. • The presence of scala vestibuli electrode insertion as well as the lateral wall electrode type, the younger patient's age, and early onset of SNHL can play important role in the prediction of post-cochlear implant facial nerve stimulation.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Idoso , Criança , Cóclea , Nervo Facial/diagnóstico por imagem , Humanos , Processo Mastoide/diagnóstico por imagem , Processo Mastoide/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Audiol Neurootol ; 27(5): 347-355, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35306487

RESUMO

INTRODUCTION: Transimpedance measurements from cochlear implant electrodes have the potential to identify anomalous electrode array placement, such as tip fold-over (TFO) or fold-back, basal electrode kinking, or buckling. Analysing transimpedance may thus replace intraoperative or post-operative radiological imaging to detect any potential misplacements. A transimpedance algorithm was previously developed to detect deviations from a normal electrode position with the aim of intraoperatively detecting TFO. The algorithm had been calibrated on 35 forced, tip folded electrode arrays in six temporal bones to determine the threshold criterion required to achieve a sensitivity of 100%. Our primary objective here was to estimate the specificity of this TFO algorithm in patients, in a prospective study, for a series of electrode arrays shown to be normally inserted by post-operative imaging. METHODS: Intracochlear voltages were intraoperatively recorded for 157 ears, using Cochlear's Custom Sound™ EP 5 electrophysiological software (Cochlear Ltd., Sydney, NSW, Australia), for both Nucleus® CI512 and CI532 electrode arrays. The algorithm analysed the recorded 22 × 22 transimpedance matrix (TIM) and results were displayed as a heatmap intraoperatively, only visible to the technician in the operating theatre. After all clinical data were collected, the algorithm was evaluated on the bench. The algorithm measures the transimpedance gradients and corresponding phase angles (θ) throughout the TIM and calculates the gradient phase range. If this was greater than the predetermined threshold, the algorithm classified the electrode array insertion as having a TFO. RESULTS: Five ears had no intraoperative TIM and four anomalous matrices were identified from heatmaps and removed from the specificity analysis. Using the 148 remaining data sets (n = 103 CI532 and n = 45 CI512), the algorithm had an average specificity of 98.6% (95.80%-99.75%). CONCLUSION: The algorithm was found to be an effective screening tool for the identification of TFOs. Its specificity was within acceptable levels and resulted in a positive predictive value of 76%, with an estimated incidence of fold-over of 4% in perimodiolar arrays. This would mean 3 out of 4 cases flagged as a fold-over would be correctly identified by the algorithm, with the other being a false positive. The measurements were applied easily in theatre allowing it to be used as a routine clinical tool for confirming correct electrode placement.


Assuntos
Implante Coclear , Implantes Cocleares , Algoritmos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Implante Coclear/métodos , Eletrodos Implantados , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa