RESUMO
Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ? 5 ?? min . An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p = 0.038 ; 166 ?? ? mol / L versus 17 ?? ? mol / L , p = 0.039 , respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.
Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Pâncreas/cirurgia , Neoplasias Pancreáticas/cirurgia , Análise Espectral/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Estudos de Viabilidade , Humanos , Pâncreas/patologia , Neoplasias Pancreáticas/patologiaRESUMO
BACKGROUND: Pancreatic cancer is the fourth leading cause of cancer-related mortality in the United States. The minority of patients can undergo curative-intended surgical therapy due to progressive disease stage at time of diagnosis. Nonetheless, tumor involvement of surgical margins is seen in up to 70% of resections, being a strong negative prognostic factor. Real-time intraoperative imaging modalities may aid surgeons to obtain tumor-free resection margins. Full-field optical coherence tomography (FF-OCT) is a promising diagnostic tool using high-resolution white-light interference microscopy without tissue processing. Therefore, we composed an atlas of FF-OCT images of malignant and benign pancreatic tissue, and investigated the accuracy with which the pathologists could distinguish these. MATERIALS AND METHODS: One hundred FF-OCT images were collected from specimens of 29 patients who underwent pancreatic resection for various indications between 2014 and 2016. One experienced gastrointestinal pathologist and one pathologist in training scored independently the FF-OCT images as malignant or benign blinded to the final pathology conclusion. Results were compared to those obtained with standard hematoxylin and eosin (H&E) slides. RESULTS: Overall, combined test characteristics of both pathologists showed a sensitivity of 72%, specificity of 74%, positive predictive value of 69%, negative predictive value of 79% and an overall accuracy of 73%. In the subset of pancreatic ductal adenocarcinoma patients, 97% of the FF-OCT images (n = 35) were interpreted as tumor by at least one pathologist. Moreover, normal pancreatic tissue was recognised in all cases by at least one pathologist. However, atrophy and fibrosis, serous cystadenoma and neuroendocrine tumors were more often wrongly scored, in 63%, 100% and 25% respectively. CONCLUSION: FF-OCT could distinguish normal pancreatic tissue from pathologic pancreatic tissue in both processed as non-processed specimens using architectural features. The accuracy in pancreatic ductal adenocarcinoma is promising and warrants further evaluation using improved assessment criteria.
Assuntos
Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Idoso , Carcinoma Ductal Pancreático/patologia , Feminino , Humanos , Masculino , Pancreatectomia/métodos , Tomografia de Coerência Óptica/métodosRESUMO
PURPOSE: Autotransplantation of ovarian tissue can be used to restore fertility in patients with cancer following gonadotoxic treatment. Whether this procedure is safe remains unclear, as current tumor detection methods render the ovarian tissue unsuitable for transplantation. Full-field optical coherence tomography (FF-OCT) is an imaging modality that rapidly produces high-resolution histology-like images without the need to fix, freeze, or stain the tissue. In this proof-of-concept study, we investigated whether FF-OCT can be used to detect metastases in ovarian tissue, thereby increasing the safety of ovarian tissue autotransplantation. We also evaluated whether cortical ovarian tissue and follicles remain viable following FF-OCT imaging. EXPERIMENTAL DESIGN: Formalin-fixed, paraffin-embedded tissue samples were obtained from seven normal ovaries and fourteen ovaries containing metastases and/or micrometastases. These samples were deparaffinized and imaged using FF-OCT. The FF-OCT images were then compared with corresponding hematoxylin and eosin-stained tissue sections. Finally, we examined the effect of FF-OCT imaging on the viability of ovarian tissues and follicles in fresh bovine ovarian tissue using a glucose uptake and neutral red staining, respectively. RESULTS: FF-OCT illustrated both normal structures and metastases in ovarian tissue within minutes. Primordial follicles were readily identifiable. Finally, tissues and follicles remained viable following FF-OCT imaging for up to 180 and 60 minutes, respectively. CONCLUSIONS: FF-OCT imaging is a promising method for the noninvasive detection of metastases, including micrometastases, in ovarian tissue. Moreover, this method facilitates the selection of cortical ovarian tissue with the highest density of primordial follicles, potentially increasing the likelihood of restoring ovarian function following ovarian tissue autotransplantation. Clin Cancer Res; 22(22); 5506-13. ©2016 AACR.
Assuntos
Metástase Neoplásica/patologia , Ovário/patologia , Animais , Bovinos , Feminino , Humanos , Tomografia de Coerência Óptica/métodosRESUMO
PURPOSE: The purpose of this study was to determine if with a multiphasic injection technique the administered amount of contrast medium for abdominal computerized tomographic angiography (CTA) can be decreased, whilst improving CT image quality. MATERIALS AND METHODS: In 30 patients a multiphasic injection method was compared to the standard uniphasic contrast medium injection protocol. Fifteen patients underwent abdominal CTA with a standard uniphasic injection protocol (protocol I) receiving 100mL of a non-ionic radiopaque contrast agent (Ioversol). The second group of 15 patients underwent CTA with a multiphasic injection protocol (protocol II) receiving a total of 89 mL Ioversol. Vascular contrast enhancement and difference in enhancement uniformity were assessed quantitatively and image quality was assessed by three independent radiologists. RESULTS: Quantitative assessment of the vascular contrast enhancement showed that there was no significant difference in enhancement uniformity for patients between the protocols. The image quality was rated as being good to excellent in 81.8% and 88.0% of the scans, for protocol I and protocol II, respectively. However these differences were not statistically significant. CONCLUSION: By using a multiphasic injection technique with CTA of the abdominal aorta a reduction of 11 percent of contrast medium can be realized. Enhancement patterns are quantitatively as well as qualitatively comparable to the standard contrast medium injection protocol.