Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38771337

RESUMO

INTRODUCTION: Preserflo MicroShunt is a novel microinvasive bleb forming device for the treatment of primary open-angle glaucoma. The intermediate- and long-term success and the impact of this procedure on corneal endothelial cell density remain to be investigated. METHODS: In this prospective observational study, 62 eyes of 55 glaucoma patients (mean age ± SD: 67.0 ± 15.0 years) receiving a Preserflo MicroShunt were included. Corneal endothelial cell density, intraocular pressure and best corrected visual acuity were assessed preoperatively and at 3, 6, 9, 12, 18 and 24 months postoperatively. Success rates, bleb revision rates and complications were analysed. Complete success was defined as an intraocular pressure reduction of ≥ 20% and achieving a target pressure of ≤ 18, ≤ 15 or ≤ 12 mmHg without antiglaucoma medication. Qualified success indicated that the criteria were reached with or without medication. RESULTS: Corneal endothelial cells showed no significant decline over 24 months (p > 0.05). Intraocular pressure showed a substantial reduction postoperatively (p < 0.001), decreasing from 29.6 ± 8,3 mmHg to 13.0 ± 4.3 mmHg after 24 months (p < 0.001). Complete and qualified success with a target pressure ≤ 15 mmHg was achieved in 52.9% and 54.6% of cases after 24 months, respectively. Best corrected visual acuity did not change after 24 months. CONCLUSION: Preserflo MicroShunt had no negative side effects on corneal endothelial cells and showed favourable success rates after 2 years in patients with open-angle glaucoma.

2.
Exp Eye Res ; 231: 109475, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37061116

RESUMO

Transcorneal electrical stimulation (TES) is used as therapy for retinal diseases such as retinitis pigmentosa (RP) and was suggested for assessing retinal sensitivity by determining phosphene thresholds, subjective luminance impressions caused by retinal stimulation. Further applications concerned the accommodation process, revealing an improved accommodative amplitude in presbyopic eyes after TES treatment. The respective changes of the ciliary muscle (CM), the structure most important for near vision, during TES are yet unknown. In a pilot study, we aimed to assess whether monocular TES leads to morphological and functional CM changes and whether central accommodation control is affected. Ten healthy, near-emmetropic adults participated in the trial (4 females, age 26.3 ± 3.6 years). Using a wavefront and a stimulus generator, a biphasic square-wave stimulus (2 s positive and 6 s negative amplitude) of 0 µA average current was produced and transferred to the eye by means of a Dawson-Trick & Litzkow electrode. Prior to the stimulation, an individual determination of phosphene thresholds served to define individual TES current amplitudes, which ranged between 60 and 100 µA. Optical coherence tomography (OCT) imaging of the right eye's temporal ciliary muscle was performed before and during ipsi- as well as contralateral monocular TES in randomized order in the morning and afternoon of the same day. During imaging, subjects fixated a target at 4 m distance and refraction was simultaneously recorded via eccentric infrared photorefraction. OCT images were assessed using previously published custom-developed software, allowing the definition of selective CM thickness (CMT) readings, and plotting of continuous CMT profiles along the muscle border. CMT profiles revealed that both stimulations, on the ipsi- and contralateral eye, induced a thickening of the CM compared to the non-stimulated state. The selective CMT readings confirmed a significant increase with ipsi- (31 ± 30 µm; p = 0.010) and contralateral (25 ± 16 µm; p = 0.001) TES. However, refraction during far vision was not significantly affected by either stimulation (ipsilateral [n = 5]: median Δw/-w/o = 0 D; contralateral [n = 7]: Δw/-w/o = 0.13 D). Pupil size on average increased during TES, but without reaching significance (ipsilateral [n = 5] median Δw/-w/o = 0.23 mm, contralateral [n = 7] Δw/-w/o = 0.39 mm). Ipsilateral CM thickening could be explained by local changes within the stimulated ciliary muscle, such as increased blood flow or interstitial fluid rise induced by TES. However, the CMT increase in the right eye when TES was performed contralaterally, on the left eye, indicates an involvement of the central control circuit of accommodation. Further possible explanations for this finding are a synchronization of neuronal activities in the visual pathway, the release of vasoactive neuropeptides, or effects on the central blood pressure regulation. Given a neuromodulation effect on the CM function, TES might have implications for children with accommodation insufficiencies and as additional therapy in myopia control management, e.g. in combination with multifocal contact lens treatment. Our study is important for the clinical application of TES, and the outcome might add crucial knowledge to the current understanding of the accommodation process and inform research and treatment of both myopia and presbyopia.


Assuntos
Miopia , Presbiopia , Adulto , Criança , Feminino , Humanos , Adulto Jovem , Acomodação Ocular , Estimulação Elétrica/métodos , Músculos , Miopia/terapia , Projetos Piloto
3.
Graefes Arch Clin Exp Ophthalmol ; 261(6): 1713-1722, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36645454

RESUMO

PURPOSE: To explore the pupil redilation during persistent light exposure (pupillary escape phenomenon) at the macula and periphery with monochromatic light stimuli. METHODS: Forty healthy subjects aged 18-64 years (24 females) were examined by chromatic pupil campimetry (CPC) using red and blue 4-s stimuli of 10° radius at the center and 20°-peripheral locations one per quadrant. One glaucoma patient and one achromatopsia patient served as disease models. For statistical analyses, linear mixed-effects models were performed followed by post hoc t-tests. RESULTS: A distinct pupillary escape could be demonstrated peripherally (blue 0.099%*s, red 0.153%*s); at the central healthy retina, there was no relevant escape, neither for blue nor red stimulation. Comparing central versus peripheral stimulation revealed highly significant differences in the escape (difference blue 0.100 ± 0.013, red 0.144 ± 0.013, < 0.0001, respectively). In the periphery, the escape was significantly more pronounced for red compared with blue stimulation (difference 0.054 ± 0.013; p = 0.0001). Enhanced pupillary escape outside of the 95% confidence interval of the linear mixed-effects model of the healthy population could be exemplarily shown in a patient with glaucomatous ganglion cell damage. In the achromatopsia example, no relevant escape was found for blue stimulation, but for red stimulation in the periphery in a comparable range to healthy controls. CONCLUSION: The results emphasize that an intact inner retinal network of nerve fibers arising from the central macular region is necessary for maintaining pupillary constriction during a bright 4-s light stimulus and preventing increase of pupillary escape. Increasing receptive field sizes towards the periphery on the level of retinal ganglion cells and less input from central 1:1 connections could be one of the driving mechanisms for pupillary escape.


Assuntos
Defeitos da Visão Cromática , Glaucoma , Feminino , Humanos , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Retina , Estimulação Luminosa , Luz
4.
Exp Eye Res ; 222: 109185, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35850172

RESUMO

Studies on the electrical excitability of retinal neurons show that photoreceptors and other cell types can be selectively activated by distinct stimulation frequencies in vitro. Yet, this principle still needs to be validated in humans in vivo. As a first step, this study explored the frequency preferences of human rods by means of transcorneal electrostimulation (TES), using the electrically-elicited pupillary responses (EEPRs) as an objective readout. The stimulation paradigm contained a 1.2 Hz sinusoidal envelope, which was superimposed on variable carrier frequencies (4-30 Hz). These currents were delivered to one of the participant's eyes via a corneal electrode and consensual pupillary reactions were recorded from the contralateral eye. The responsiveness of the retina at each frequency was assessed based on the EEPR dynamics. Differences between healthy participants and patients with retinitis pigmentosa were evaluated to identify the preferred frequency range of rods. The responsiveness of healthy individuals revealed a clear peak around 6-8 Hz. In contrast, the pupillary responses of patients were significantly reduced in the lower frequency range. These findings suggest that the responses in this frequency bin were selectively mediated by rods. This work provides evidence that different retinal cell types can be selectively activated via TES in vivo, and that this effect can be captured noninvasively using EEPRs. This knowledge may be exploited for the diagnostics and therapy of retinal diseases, e.g., to design cell-specific functional tests for the degenerating retina, or to optimize stimulation paradigms which are currently used by retinal prostheses.


Assuntos
Córnea , Retinose Pigmentar , Córnea/fisiologia , Estimulação Elétrica , Humanos , Retina/metabolismo , Células Fotorreceptoras Retinianas Bastonetes , Retinose Pigmentar/metabolismo
5.
Doc Ophthalmol ; 145(2): 133-145, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35788850

RESUMO

PURPOSE: To investigate the applicability of liquid crystal displays (LCD) as suitable replacement for cathode ray tube monitors (CRT) as stimulator for the sweep VEP for estimating visual acuity. METHODS: In a first experiment, sweep VEPs were recorded in 13 healthy volunteers with best-corrected visual acuity with an LCD and a CRT monitor, respectively. Time-to-peak after stimulus and peak-to-trough amplitudes as well as the visual acuity, estimated using a second-order polynomial and the modified Ricker model, were compared between both monitor types. In a second experiment, sweep VEPs were recorded in six healthy volunteers with two levels of stimulus contrast using artificially reduced visual acuities as well as best-corrected with the same monitors as in the first experiment and additionally, a modern LCD gaming monitor with a response time of 1 ms. Time-to-peak after stimulus and peak-to-trough amplitudes were compared between the different combinations of monitors and contrasts. Finally, visual acuities estimated using the modified Ricker model were compared to subjective visual acuities determined using the Freiburg Visual Acuity and Contrast Test (FrACT). RESULTS: In the first experiment, the time-to-peak after stimulus presentation was statistically significantly delayed for LCD displays (mean difference [confidence interval]: 60.0 [54.0, 65.9] ms; t(516) = 19.7096, p < 0.0001). Likewise, peak-to-trough amplitudes were statistically significantly smaller for the LCD stimulator, however, not clinically relevant (mean difference [confidence interval]: - 0.89 [- 1.59, - 0.20] µV; t(516) = - 2.5351, p = 0.0115). No statistically significant effect of the monitor type on the estimated visual acuity was found for neither method, second-order polynomial, nor the modified Ricker model. In the second experiment, statistically significant delays of the time-to-peak after stimulus onset were found for all combinations of monitor and contrast compared to the CRT monitor. A statistically significant, but not clinically relevant, difference of the peak-to-trough amplitudes was only found between the CRT monitor and the LCD gaming monitor (mean difference [confidence interval]: 2.6 [1.2, 4.0] µV; t(814) = 4.66, p < 0.0001). Visual acuities estimated from LCD stimulation significantly underestimated the subjective visual acuity up to 0.2 logMAR using the conversion formula of the first experiment. No statistically significant difference was found when using conversion formulas adjusted for each combination of monitor and contrast. CONCLUSIONS: Based on the results of this study, LCD monitors may substitute CRT monitors for presenting the stimuli for the sweep VEP to objectively estimate visual acuity. Nevertheless, it is advisable to perform a calibration and to collect normative data of healthy volunteers using best-corrected and artificially reduced visual acuity for establishing a conversion formula between sweep VEP outcome and the subjective visual acuity before replacing a CRT with an LCD stimulator.


Assuntos
Potenciais Evocados Visuais , Cristais Líquidos , Eletrorretinografia , Humanos , Testes Visuais/métodos , Acuidade Visual
6.
Graefes Arch Clin Exp Ophthalmol ; 260(5): 1675-1685, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34902059

RESUMO

PURPOSE: To examine systematically how prechiasmal, chiasmal, and postchiasmal lesions along the visual pathway affect the respective pupillary responses to specific local monochromatic stimuli. METHODS: Chromatic pupil campimetry (CPC) was performed in three patient groups (10 subjects with status after anterior ischemic optic neuropathy, 6 with chiasmal lesions, and 12 with optic tract or occipital lobe lesions (tumor, ischemia)) using red, low-intensity red, and blue local stimuli within the central 30° visual field. Affected areas - as determined by visual field defects revealed using conventional static perimetry - were compared with non-affected areas. Outcome parameters were the relative maximal constriction amplitude (relMCA) and the latency to constriction onset of the pupillary responses. RESULTS: A statistically significant relMCA reduction was observed in the affected areas of postchiasmal lesions with red (p = 0.004) and low-intensity red stimulation (p = 0.001). RelMCA reduction in the affected areas seemed more pronounced for low-intensity red stimulation (46.5% mean reduction compared to non-affected areas; 36% for red stimulation), however statistically not significant. In prechiasmal lesions, a statistically significant latency prolongation could be demonstrated in the affected areas with low-intensity red stimulation (p = 0.015). CONCLUSION: Our results indicate that the choice of stimulus characteristics is relevant in detecting defects in the pupillary pathway of impairment along the visual pathway, favoring red stimuli of low intensity over blue stimuli. Such knowledge opens the door for further fundamental research in pupillary pathways and is important for future clinical application of pupillography in neuro-ophthalmologic patients.


Assuntos
Distúrbios Pupilares , Vias Visuais , Humanos , Estimulação Luminosa , Pupila/fisiologia , Distúrbios Pupilares/diagnóstico , Reflexo Pupilar/fisiologia , Testes de Campo Visual , Campos Visuais
7.
Int J Mol Sci ; 23(7)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35409251

RESUMO

Calpains are a family of calcium-activated proteases involved in numerous disorders. Notably, previous studies have shown that calpain activity was substantially increased in various models for inherited retinal degeneration (RD). In the present study, we tested the capacity of the calpain-specific substrate t-BOC-Leu-Met-CMAC to detect calpain activity in living retina, in organotypic retinal explant cultures derived from wild-type mice, as well as from rd1 and RhoP23H/+ RD-mutant mice. Test conditions were refined until the calpain substrate readily detected large numbers of cells in the photoreceptor layer of RD retina but not in wild-type retina. At the same time, the calpain substrate was not obviously toxic to photoreceptor cells. Comparison of calpain activity with immunostaining for activated calpain-2 furthermore suggested that individual calpain isoforms may be active in distinct temporal stages of photoreceptor cell death. Notably, calpain-2 activity may be a relatively short-lived event, occurring only towards the end of the cell-death process. Finally, our results support the development of calpain activity detection as a novel in vivo biomarker for RD suitable for combination with non-invasive imaging techniques.


Assuntos
Degeneração Retiniana , Animais , Biomarcadores/metabolismo , Calpaína/metabolismo , Morte Celular/fisiologia , Camundongos , Células Fotorreceptoras de Vertebrados/metabolismo , Retina/metabolismo , Degeneração Retiniana/diagnóstico , Degeneração Retiniana/metabolismo
8.
Int Ophthalmol ; 42(5): 1427-1436, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34826023

RESUMO

PURPOSE: To assess the effect of central and peripheral stimulation on the pupillary light reflex. The aim was to detect possible differences between cone- and rod-driven reactions. METHODS: Relative maximal pupil constriction amplitude (relMCA) and latency to constriction onset (latency) to cone- and rod-specific stimuli of 30 healthy participants (24 ± 5 years (standard deviation)) were measured using chromatic pupil campimetry. Cone- and rod-specific stimuli had different intensities and wavelengths according to the Standards in Pupillography. Five filled circles with radii of 3°, 5°, 10°, 20° and 40° and four rings with a constant outer radius of 40° and inner radii of 3°, 5°, 10° and 20° were used as stimuli. RESULTS: For cone-and rod-specific stimuli, relMCA increased with the stimulus area for both, circles and rings. However, increasing the area of a cone-specific ring by minimizing its inner radius with constant outer radius increased relMCA significantly stronger than the same did for a rod-specific ring. For cones and rods, a circle stimulus with a radius of 40° created a lower relMCA than the summation of the relMCAs to the corresponding ring and circle stimuli which combined create a 40° circle-stimulus. Latency was longer for rods than for cones. It decreased with increasing stimulus area for circle stimuli while it stayed nearly constant with increasing ring stimulus area for cone- and rod-specific stimuli. CONCLUSION: The effect of central stimulation on relMCA is more dominant for cone-specific stimuli than for rod-specific stimuli while latency dynamics are similar for both conditions.


Assuntos
Reflexo Pupilar , Células Fotorreceptoras Retinianas Bastonetes , Humanos , Luz , Miose , Estimulação Luminosa , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Células Fotorreceptoras Retinianas Cones , Células Fotorreceptoras Retinianas Bastonetes/fisiologia
9.
Ophthalmologica ; 244(5): 396-407, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32805733

RESUMO

This work presents a quick clinical protocol for dark-adapted chromatic (DAC) perimetry as well as a novel clinical tool, scotopic chromatic pupil campimetry (CPC). The goal of the study was to explore the applicability of these methods in a clinical setting, their test-retest repeatability, and the congruence of the results. Local rod sensitivity was assessed at 36 locations within 30° eccentricity of the visual field in 15 healthy subjects (mean age 43 ± 16 years; 7 females and 8 males) with DAC perimetry (red and cyan stimuli) and CPC 2 times in repeated measurements. The duration of individual measurements was 370 ± 5 s for CPC and 366 ± 62 s for DAC perimetry. The intraclass correlation (ICC) coefficient was 0.53 for DAC perimetry cyan stimuli, 0.67 for red stimuli, and 0.93 for CPC. However, the spatial resolution of CPC was substantially smaller than in DAC perimetry. We did not find a correlation of DAC perimetry and CPC measurements on the global or the local level. In comparison to DAC perimetry, CPC shows a superior intervisit repeatability in detecting functional changes in the rod population in an objective way with lower spatial resolution. Our results also indicate that these 2 methods measure the rod function in different ways and could thus constitute complementary scotopic functional diagnostics.


Assuntos
Testes de Campo Visual , Campos Visuais , Adulto , Protocolos Clínicos , Adaptação à Escuridão , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade
10.
Proc Natl Acad Sci U S A ; 115(13): E2997-E3006, 2018 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-29531030

RESUMO

Inherited retinal degeneration (RD) is a devastating and currently untreatable neurodegenerative condition that leads to loss of photoreceptor cells and blindness. The vast genetic heterogeneity of RD, the lack of "druggable" targets, and the access-limiting blood-retinal barrier (BRB) present major hurdles toward effective therapy development. Here, we address these challenges (i) by targeting cGMP (cyclic guanosine- 3',5'-monophosphate) signaling, a disease driver common to different types of RD, and (ii) by combining inhibitory cGMP analogs with a nanosized liposomal drug delivery system designed to facilitate transport across the BRB. Based on a screen of several cGMP analogs we identified an inhibitory cGMP analog that interferes with activation of photoreceptor cell death pathways. Moreover, we found liposomal encapsulation of the analog to achieve efficient drug targeting to the neuroretina. This pharmacological treatment markedly preserved in vivo retinal function and counteracted photoreceptor degeneration in three different in vivo RD models. Taken together, we show that a defined class of compounds for RD treatment in combination with an innovative drug delivery method may enable a single type of treatment to address genetically divergent RD-type diseases.


Assuntos
Barreira Hematorretiniana/metabolismo , GMP Cíclico/análogos & derivados , GMP Cíclico/administração & dosagem , Modelos Animais de Doenças , Sistemas de Liberação de Medicamentos , Degeneração Retiniana/tratamento farmacológico , Animais , Barreira Hematorretiniana/efeitos dos fármacos , GMP Cíclico/farmacologia , Proteínas Quinases Dependentes de GMP Cíclico/metabolismo , Lipossomos , Camundongos , Células Fotorreceptoras/metabolismo , Retina/efeitos dos fármacos , Retina/metabolismo , Degeneração Retiniana/metabolismo , Transdução de Sinais/efeitos dos fármacos
11.
Exp Eye Res ; 186: 107741, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31336108

RESUMO

There is evidence for a possible link between myopia development and near vision. We investigated the effect of prolonged nearwork on ciliary muscle (CM) morphology and accommodation in 18 myopic and 17 emmetropic subjects (age 19 to 25). The CM was imaged during far (0.25 D) and near vision (4 D) using optical coherence tomography (OCT), and accommodation to a step pulse (0.25 D - 4 D - 0.25 D, 15 s each) was assessed by eccentric infrared photorefraction before and after a 30-min reading task at 25 cm. OCT images were analyzed using a custom-developed semi-automatic segmentation algorithm to determine CM thickness (CMT) profiles and selective CMT readings. Accommodation was assessed using a non-linear model. On average, the CM got thinner after nearwork, predominantly at 0.0-1.4 mm posterior to the scleral spur in emmetropes, and at 1.0-1.9 mm in myopes. Selective CMT readings confirmed a significant thinning after nearwork (univariate ANOVA F1,66 = 26.313, p < 0.001), without any influence of the subjects' refractive state (F1,66 = 1.887, p = 0.174) or the target distance (F1,66 = 0.014, p = 0.907). The mean accommodation response for targets at infinity was significantly increased after nearwork (F1,32 = 7.775, p = 0.009), with a larger myopic shift in myopes (F1,32 = 11.310, p = 0.002). No change in velocity of accommodation was found. Sharing properties of striated muscles, the CM was expected to increase its thickness, but the opposite was found. Previous studies suggesting sustained nearwork to result in a CM spasm cannot be confirmed by the data presented here. Further research exploring the possible impact of sympathetic innervation is necessary as it is activated during intense nearwork.


Assuntos
Acomodação Ocular/fisiologia , Corpo Ciliar/patologia , Emetropia/fisiologia , Músculo Liso/patologia , Miopia/fisiopatologia , Trabalho , Adulto , Corpo Ciliar/diagnóstico por imagem , Feminino , Humanos , Masculino , Músculo Liso/diagnóstico por imagem , Refração Ocular , Tomografia de Coerência Óptica , Visão Binocular , Adulto Jovem
12.
Doc Ophthalmol ; 138(2): 97-116, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30694438

RESUMO

PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.


Assuntos
Potenciais Evocados Visuais/fisiologia , Doenças do Cristalino/fisiopatologia , Doenças do Nervo Óptico/fisiopatologia , Doenças Retinianas/fisiopatologia , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Eletrorretinografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Testes Visuais/métodos , Adulto Jovem
13.
Sensors (Basel) ; 19(22)2019 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-31717510

RESUMO

The aim of this study was to investigate the use of inexpensive and easy-to-use hydrogel "marble" electrodes for the recording of electrical potentials of the human visual cortex using visual evoked potentials (VEPs) as example. Top hat-shaped holders for the marble electrodes were developed with an electrode cap to acquire the signals. In 12 healthy volunteers, we compared the VEPs obtained with conventional gold-cup electrodes to those obtained with marble electrodes. Checkerboards of two check sizes-0.8° and 0.25°-were presented. Despite the higher impedance of the marble electrodes, the line noise could be completely removed by averaging 64 single traces, and VEPs could be recorded. Linear mixed-effect models using electrode type, stimulus, and recording duration revealed a statistically significant effect of the electrode type on only VEP N75 peak latency (mean ± SEM: 1.0 ± 1.2 ms) and amplitude (mean ± SEM: 0.8 ± 0.9 µV) The mean amplitudes of the delta, theta, alpha, beta, and gamma frequency bands of marble electrodes were statistically significantly different and, on average, 25% higher than those of gold-cup electrodes. However, the mean amplitudes showed a statistically significant strong correlation (Pearson's r = 0.8). We therefore demonstrate the potential of the inexpensive and efficient hydrogel electrode to replace conventional gold-cup electrodes for the recording of VEPs and possibly other recordings from the human cortex.


Assuntos
Potenciais Evocados Visuais/fisiologia , Polímeros/química , Eletrodos Implantados , Eletrofisiologia , Humanos , Córtex Visual/fisiologia
14.
Exp Eye Res ; 176: 210-218, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30003883

RESUMO

The purpose was to evaluate retinal function by measuring pupillary responses to sinusoidal transcorneal electrostimulation in healthy young human subjects. This work also translates data from analogous in vitro experiments and connects it to the pupillary responses obtained in human experiments. 14 healthy human subjects participated (4 males, 10 females); for the in vitro experiments, two male healthy mouse retinas (adult wild-type C57B/6J) were used. Pupillary responses to sinusoidal transcorneal electrostimulation of varying stimulus carrier frequencies (10, 20 Hz; envelope frequency constantly kept at 1.2 Hz) and intensities (10, 20, 50 µA) were recorded and compared with those obtained with light stimulation (1.2 Hz sinusoidal blue, red light). A strong correlation between the sinusoidal stimulation (electrical as well as light) and the pupillary sinusoidal response was found. The difference between the lag of electrical and light stimulation allowed the estimation of an intensity threshold for pupillary responses to transcorneal electrostimulation (mean ±â€¯SD: 30 ±â€¯10 µA (10 Hz); 38 ±â€¯10 µA (20 Hz)). A comparison between the results of the two stimulation frequencies showed a not statistically significant smaller lag for 10 Hz (10 Hz: 633 ±â€¯90 ms; 20 Hz: 725 ±â€¯178 ms; 50 µA intensity). Analogous in vitro experiments on murine retinas indicated a selective stimulation of photoreceptors and bipolar cells (lower frequencies) and retinal ganglion cells (higher frequencies) and lower stimulation thresholds for the retinal network with sinusoidal compared to pulsatile stimulation - emphasizing that sinusoidal waveforms are well-suited to our purposes. We demonstrate that pupillary responses to sinusoidal transcorneal electrostimulation are measurable as an objective marker in healthy young subjects, even at very low stimulus intensities. By using this unique approach, we unveil the potential for an estimation of the individual intensity threshold and a selective activation of different retinal cell types in humans by varying the stimulation frequency. This technique may have broad clinical utility as well as specific relevance in the monitoring of patients with hereditary retinal disorders, especially as implemented in study protocols for novel therapies, e.g. retinal prostheses or gene therapies.


Assuntos
Estimulação Elétrica , Fosfenos/fisiologia , Reflexo Pupilar/fisiologia , Retina/fisiologia , Percepção Visual/fisiologia , Adulto , Animais , Córnea/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Estimulação Luminosa , Células Fotorreceptoras de Vertebrados/fisiologia , Células Bipolares da Retina/fisiologia , Células Ganglionares da Retina/fisiologia
15.
Doc Ophthalmol ; 136(1): 75-92, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29128949

RESUMO

PURPOSE: The ISCEV standards and recommendations for electrophysiological recordings in ophthalmology define a set of protocols with stimulus parameters, acquisition settings, and recording conditions, to unify the data and enable comparability of results across centers. Up to now, however, there are no standards to define the storage and exchange of such electrophysiological recordings. The aim of this study was to develop an open standard data format for the exchange and storage of visual electrophysiological data (ElVisML). METHODS: We first surveyed existing data formats for biomedical signals and examined their suitability for electrophysiological data in ophthalmology. We then compared the suitability of text-based and binary formats, as well as encoding in Extensible Markup Language (XML) and character/comma-separated values. RESULTS: The results of the methodological consideration led to the development of ElVisML with an XML-encoded text-based format. This allows referential integrity, extensibility, the storing of accompanying units, as well as ensuring confidentiality and integrity of the data. A visualization of ElVisML documents (ElVisWeb) has additionally been developed, which facilitates the exchange of recordings on mailing lists and allows open access to data along with published articles. CONCLUSIONS: The open data format ElVisML ensures the quality, validity, and integrity of electrophysiological data transmission and storage as well as providing manufacturer-independent access and long-term archiving in a future-proof format. Standardization of the format of such neurophysiology data would promote the development of new techniques and open software for the use of neurophysiological data in both clinic and research.


Assuntos
Acesso à Informação , Bases de Dados Factuais , Eletrofisiologia/normas , Armazenamento e Recuperação da Informação , Oftalmologia/normas , Humanos , Bases de Conhecimento
16.
Graefes Arch Clin Exp Ophthalmol ; 255(9): 1837-1842, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28687871

RESUMO

PURPOSE: The pupil light reflex is considered to be a simple subcortical reflex. However, many studies have proven that patients with isolated occipital lesions with homonymous hemianopia show pupillary hemihypokinesia. Our hypothesis is that the afferent pupillary system consists of two pathways: one via intrinsically photosensitive retinal ganglion cells (ipRGCs), the other running through the normal RGCs via the visual cortex. The purpose of this study was to test the hypothesis of these two separate pupillomotor pathways. METHODS: 12 patients (59.1 ± 18.8 years) with homonymous hemianopia due to post-geniculate lesions of the visual pathway and 20 normal controls (58.6 ± 12.9 years) were examined using chromatic pupillography: stimulus intensity was 28 lx corneal illumination, stimulus duration was 4.0 s, and the stimulus wavelengths were 420 ± 20 nm (blue) and 605 ± 20 nm (red), respectively. The examined parameters were baseline pupil diameter, latency, and relative amplitudes (absolute amplitudes compared to baseline), measured at maximal constriction, at 3 s after stimulus onset, at stimulus offset, and at 3 s and 7 s after stimulus offset. RESULTS: The relative amplitudes for the red stimulus were significantly smaller for hemianopia patients compared to the normal controls [maximal constriction: 35.6 ± 5.9% (hemianopia) to 42.3 ± 5.7% (normal); p = 0.004; 3 s after stimulus onset: p = 0.004; stimulus offset: p = 0.001]. No significant differences in any parameter were found between the two groups using the blue stimulus. CONCLUSIONS: The results support the hypothesis that the ipRGC pathway is mainly subcortical, whereas a second, non-ipRGC pathway via the occipital cortex exists.


Assuntos
Encefalopatias/complicações , Técnicas de Diagnóstico Oftalmológico , Hemianopsia/diagnóstico , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Córtex Visual/fisiopatologia , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Encefalopatias/diagnóstico , Feminino , Hemianopsia/etiologia , Hemianopsia/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Mesencéfalo/diagnóstico por imagem , Pessoa de Meia-Idade , Estimulação Luminosa , Reprodutibilidade dos Testes , Células Ganglionares da Retina/fisiologia , Tomografia Computadorizada por Raios X , Córtex Visual/diagnóstico por imagem , Adulto Jovem
17.
J Neuroophthalmol ; 37(3): 247-252, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28708670

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the pupil response to chromatic stimuli in patients with lesions in the dorsal midbrain and possibly gain new insights into the afferent pupillary pathways. METHODS: Color pupillography was performed in 5 patients with dorsal midbrain syndrome (DMS), and their results were compared with those of 20 healthy control subjects. We used full-field red stimuli (605 nm) that primarily address the rod/cone system and blue stimuli (420 nm) that preferentially activate intrinsically photosensitive retinal ganglion cells (ipRGCs) directly, with a duration of 4 seconds and a stimulus intensity of 28 lx corneal illumination under mesopic conditions. One eye was stimulated, and the consensual pupil response was recorded and analyzed. RESULTS: The pupillary light reflex in patients with DMS was reduced, differed in shape, and showed a prolonged latency time compared to normal subjects. The blue response was less affected than the red response: the mean maximal relative amplitude (M) was 15.8% (SD = 7.8) in patients with DMS compared with 43.0% (SD = 5.5) in normal subjects for red stimulation, and M = 40.8%, SD = 8.4 (DMS) with M = 58.3%, SD = 4.8 (normals) for blue stimulation. The reduction was 63% for red stimulation but only 30% for blue stimulation in patients with DMS. Moreover, there was a preserved postillumination pupil response to blue stimulation in DMS patients. CONCLUSIONS: In DMS, the melanopsin-mediated ipRGC pathway appeared relatively preserved.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Mesencéfalo/fisiopatologia , Transtornos da Motilidade Ocular/diagnóstico , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos da Motilidade Ocular/fisiopatologia , Estimulação Luminosa , Opsinas de Bastonetes/metabolismo , Síndrome , Adulto Jovem
18.
Graefes Arch Clin Exp Ophthalmol ; 254(7): 1361-70, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27099948

RESUMO

PURPOSE: The aim was to investigate the involvement of intrinsically photosensitive retinal ganglion cells (ipRGCs) in patients with manifest glaucoma and ocular hypertension (OH) using specific parameters of the pupil light reflex to chromatic stimuli. METHODS: Twenty-five patients with manifest glaucoma, 16 patients with OH and 16 healthy control subjects were stimulated with 28 lx red (605 nm) or blue (420 nm) light with a duration of either 1 s or 4 s. The consensual pupil light reaction was recorded by means of infrared pupillometry. The maximal relative amplitude (MRA), the post-illumination pupil response PIPRblue-red, and the slope of the response during exposure to the 4 s red stimulus (SORRS) were calculated and compared using ANOVA and Tukey-Kramer post-hoc tests. Correlations between pupil parameters and visual field defects were analyzed using Pearson correlation coefficient r. RESULTS: PIPRblue-red was reduced in glaucoma patients compared to normals (p < 0.001) and OH (p < 0.01). There was no significant difference between OH and normals. Glaucoma patients showed additionally reduced MRA for red and blue light (p < 0.05) and a pupillary escape during exposure to red light (increased SORRS, p < 0.0005). This pupillary escape could also be seen in single subjects with OH. Significant correlations between pupil parameters and visual field defects were detected. CONCLUSIONS: The reduced PIPRblue-red indicates a characteristic impairment of the melanopsin-driven pathway of ipRGCs in glaucoma patients, whereas the reduced MRA and increased SORRS suggest a disturbed synaptic function and altered interaction between outer photoreceptors, RGCs, and ipRGCs.


Assuntos
Glaucoma/metabolismo , Reflexo Pupilar/fisiologia , Células Ganglionares da Retina/fisiologia , Campos Visuais , Adulto , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Opsinas de Bastonetes/metabolismo
19.
Doc Ophthalmol ; 130(2): 121-30, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25612939

RESUMO

PURPOSE: Cannabis is a psychotomimetic agent that induces impairment of sensory perception. We present detailed clinical and electrophysiological data of patients with hallucinogen persisting perception disorder (HPPD) after marijuana consumption. METHODS: A HPPD patient and four heavy cannabis smokers with no visual disturbances (controls) underwent complete ophthalmological examination including psychophysical tests (visual acuity, color vision, visual field, and dark adaptation) and detailed electrophysiological examinations, including extended Ganzfeld ERG, multifocal ERG, and electrooculography (EOG). Furthermore, electrically evoked phosphene thresholds (EPTs) were measured to further evaluate retinal function. RESULTS: Ophthalmological and most electrophysiological examinations were within normal limits for the HPPD patient and for all control subjects. Interestingly, EOG results of the HPPD patient showed a slightly reduced fast oscillation ratio, diminished standing potentials of the slow oscillations, and a light peak within normal range resulting in higher Arden ratios. The EPTs of the patient were reduced, in particular for pulses with long durations (50 ms) causing visual sensations even at lowest possible currents of the neurostimulator. The control subjects did not reveal such alterations. CONCLUSIONS: Our findings suggest a direct effect of cannabinoids on the retina and retinal pigment epithelium function, which may be involved in disturbances of the visual function experienced after drug consumption. The observations presented here may contribute to the elucidation of the detailed mechanism. Furthermore, EOG and EPT measurements may be useful tools to demonstrate long-term retinal alterations in cannabis-induced HPPD in patients.


Assuntos
Abuso de Maconha/fisiopatologia , Transtornos da Percepção/fisiopatologia , Transtornos da Visão/fisiopatologia , Adulto , Cannabis , Adaptação à Escuridão , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retina/fisiopatologia , Epitélio Pigmentado da Retina/fisiopatologia , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa