Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Skeletal Radiol ; 53(3): 437-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37580537

RESUMO

OBJECTIVE: To determine the cost-effectiveness of rotator cuff hydroxyapatite deposition disease (HADD) treatments. METHOD: A 1-year time horizon decision analytic model was created from the US healthcare system perspective for a 52-year-old female with shoulder HADD failing conservative management. The model evaluated the incremental cost-effectiveness ratio (ICER) and net monetary benefit (NMB) of standard strategies, including conservative management, ultrasound-guided barbotage (UGB), high- and low-energy extracorporeal shock wave therapy (ECSW), and surgery. The primary effectiveness outcome was quality-adjusted life years (QALY). Costs were estimated in 2022 US dollars. The willingness-to-pay (WTP) threshold was $100,000. RESULTS: For the base case, UGB was the preferred strategy (0.9725 QALY, total cost, $2199.35, NMB, $95,048.45, and ICER, $33,992.99), with conservative management (0.9670 QALY, NMB $94,688.83) a reasonable alternative. High-energy ECSW (0.9837 QALY, NMB $94,805.72), though most effective, had an ICER of $121, 558.90, surpassing the WTP threshold. Surgery (0.9532 QALY, NMB $92,092.46) and low-energy ECSW (0.9287 QALY, NMB $87,881.20) were each dominated. Sensitivity analysis demonstrated that high-energy ECSW would become the favored strategy when its cost was < $2905.66, and conservative management was favored when the cost was < $990.34. Probabilistic sensitivity analysis supported the base case results, with UGB preferred in 43% of simulations, high-energy ECSW in 36%, conservative management in 20%, and low-energy ECSW and surgery in < 1%. CONCLUSION: UGB appears to be the most cost-effective strategy for patients with HADD, while surgery and low-energy ECSW are the least cost-effective. Conservative management may be considered a reasonable alternative treatment strategy in the appropriate clinical setting.


Assuntos
Análise de Custo-Efetividade , Durapatita , Feminino , Humanos , Pessoa de Meia-Idade , Análise Custo-Benefício
2.
AJR Am J Roentgenol ; 218(2): 227-233, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34406055

RESUMO

BACKGROUND. Superior labrum anterior and posterior (SLAP) tears are a common shoulder pathology. Although MRI is the imaging reference standard for diagnosis of this pathology, the cost-effectiveness of common MRI strategies is unclear. OBJECTIVE. The primary objective of our study was to determine the cost-effectiveness of the common MRI-based strategies used for the diagnosis of SLAP tears. METHODS. We created decision analytic models from the perspective of the U.S. health care system over a 2-year time horizon for a hypothetical population of 25-year-old patients with a previous diagnosis of SLAP tear. We used the decision models to compare the differences in incremental cost-effectiveness of the common MRI strategies, which included combinations of 1.5-T and 3-T MR arthrography (MRA) and unenhanced MRI protocols, and the resulting treatment applied for these patients. Input data on cost, probability, and utility estimates were obtained through a comprehensive literature search. The primary effectiveness outcome was quality-adjusted life years. Costs were estimated in 2017 U.S. dollars. RESULTS. When all imaging strategies were considered, the unenhanced 3-T MRI-based imaging strategy was the preferred and dominant option over 3-T MRA and 1.5-T imaging (MRI and MRA). When the model was run without 3-T imaging as an option, 1.5-T MRA was the favored option. Probabilistic sensitivity analyses confirmed the same preferred imaging strategy results. CONCLUSION. An unenhanced 3-T MRI-based strategy is the most cost-effective imaging option for patients with suspected SLAP tear. When 3-T imaging is not available, 1.5-T MRA is more cost-effective than 1.5-T MRI. The main driver of these results is the fact that 3-T MRI and 1.5-T MRA are the most specific tests in these respective scenarios, which results in fewer false-positives, prevents unnecessary surgeries, and leads to decreased costs. CLINICAL IMPACT. Our cost-effectiveness model findings complement prior diagnostic accuracy work, helping produce a more comprehensive approach to define imaging utility for radiologists, clinicians, and patients with SLAP tears who have access to various types of MRI options.


Assuntos
Artrografia/métodos , Análise Custo-Benefício/métodos , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Lesões do Ombro/diagnóstico por imagem , Lesões do Ombro/economia , Adulto , Artrografia/economia , Análise Custo-Benefício/economia , Análise Custo-Benefício/estatística & dados numéricos , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Articulação do Ombro/diagnóstico por imagem
3.
Semin Musculoskelet Radiol ; 25(3): 455-467, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34547811

RESUMO

Three-dimensional (3D) magnetic resonance imaging (MRI) of the knee is widely used in musculoskeletal (MSK) imaging. Currently, 3D sequences are most commonly used for morphological imaging. Isotropic 3D MRI provides higher out-of-plane resolution than standard two-dimensional (2D) MRI, leading to reduced partial volume averaging artifacts and allowing for multiplanar reconstructions in any plane with any thickness from a single high-resolution isotropic acquisition. Specifically, isotropic 3D fast spin-echo imaging, with options for tissue weighting similar to those used in multiplanar 2D FSE imaging, is of particular interest to MSK radiologists. New applications for 3D spatially encoded sequences are also increasingly available for clinical use. These applications offer advantages over standard 2D techniques for metal artifact reduction, quantitative cartilage imaging, nerve imaging, and bone shape analysis. Emerging fast imaging techniques can be used to overcome the long acquisition times that have limited the adoption of 3D imaging in clinical protocols.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Artefatos , Humanos , Articulação do Joelho/diagnóstico por imagem
4.
Skeletal Radiol ; 50(4): 693-703, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32948903

RESUMO

OBJECTIVE: To evaluate the feasibility of producing 2-dimensional (2D) virtual noncontrast images and 3-dimensional (3D) bone models from dual-energy computed tomography (DECT) arthrograms and to determine whether this is best accomplished using 190 keV virtual monoenergetic images (VMI) or virtual unenhanced (VUE) images. MATERIALS AND METHODS: VMI and VUE images were retrospectively reconstructed from patients with internal derangement of the shoulder or knee joint who underwent DECT arthrography between September 2017 and August 2019. A region of interest was placed in the area of brightest contrast, and the mean attenuation (in Hounsfield units [HUs]) was recorded. Two blinded musculoskeletal radiologists qualitatively graded the 2D images and 3D models using scores ranging from 0 to 3 (0 considered optimal). RESULTS: Twenty-six patients (mean age ± SD, 57.5 ± 16.8 years; 6 women) were included in the study. The contrast attenuation on VUE images (overall mean ± SD, 10.5 ± 16.4 HU; knee, 19.3 ± 10.7 HU; shoulder, 5.0 ± 17.2 HU) was significantly lower (p < 0.001 for all comparisons) than on VMI (overall mean ± SD, 107.7 ± 43.8 HU; knee, 104.6 ± 31.1 HU; shoulder, 109.6 ± 51.0 HU). The proportion of cases with optimal scores (0 or 1) was significantly higher with VUE than with VMI for both 2D and 3D images (p < 0.001). CONCLUSIONS: DECT arthrography can be used to produce 2D virtual noncontrast images and to generate 3D bone models. The VUE technique is superior to VMI in producing virtual noncontrast images.


Assuntos
Artrografia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
5.
Skeletal Radiol ; 50(5): 955-965, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33037447

RESUMO

OBJECTIVE: To determine whether a simulated low-dose metal artifact reduction (MAR) CT technique is comparable with a clinical dose MAR technique for shoulder arthroplasty evaluation. MATERIALS AND METHODS: Two shoulder arthroplasties in cadavers and 25 shoulder arthroplasties in patients were scanned using a clinical dose (140 kVp, 300 qrmAs); cadavers were also scanned at half dose (140 kVp, 150 qrmAs). Images were reconstructed using a MAR CT algorithm at full dose and a noise-insertion algorithm simulating 50% dose reduction. For the actual and simulated half-dose cadaver scans, differences in SD for regions of interest were assessed, and streak artifact near the arthroplasty was graded by 3 blinded readers. Simulated half-dose scans were compared with full-dose scans in patients by measuring differences in implant position and by comparing readers' grades of periprosthetic osteolysis and muscle atrophy. RESULTS: The mean difference in SD between actual and simulated half-dose methods was 2.42 HU (95% CI [1.4, 3.4]). No differences in streak artifact grades were seen in 13/18 (72.2%) comparisons in cadavers. In patients, differences in implant position measurements were within 1° or 1 mm in 149/150 (99.3%) measurements. The inter-reader agreement rates were nearly identical when readers were using full-dose (77.3% [232/300] for osteolysis and 76.9% [173/225] for muscle atrophy) and simulated half-dose (76.7% [920/1200] for osteolysis and 74.0% [666/900] for muscle atrophy) scans. CONCLUSION: A simulated half-dose MAR CT technique is comparable both quantitatively and qualitatively with a standard-dose technique for shoulder arthroplasty evaluation, demonstrating that this technique could be used to reduce dose in arthroplasty imaging.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Algoritmos , Artroplastia , Cadáver , Humanos , Metais , Imagens de Fantasmas
6.
AJR Am J Roentgenol ; 215(2): 425-432, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374668

RESUMO

OBJECTIVE. The purpose of this study was to compare a combined dual-energy CT (DECT) and single-energy CT (SECT) metal artifact reduction technique with a SECT metal artifact reduction technique for detecting lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Two CT phantoms with a cobalt chromium sphere attached to a titanium rod, simulating an arthroplasty, within a background of soft-tissue attenuation containing spherical lesions (range, 10-20 mm) around the head and stem of different attenuations from the background (range of attenuation, 10-70 HU) were scanned with a single CT scanner individually (unilateral) and together (bilateral) with the following three dose-equivalent techniques: the currently used clinical protocol (140 kVp, 300 Reference mAs); 100 kVp; and DECT (100 kVp and 150 kVp with a tin filter). Three radiologists reviewed the datasets to identify lesions. Nonparametric AUC was estimated for each reader with each technique. Multireader ANOVA was performed to compare AUCs. Multiple-variable logistic regression analysis was used to identify factors affecting sensitivity and specificity. RESULTS. Accuracy was lower (p < 0.001) for the DECT 130-keV technique than for the 100-, 70-, and 140-kVp techniques. Sensitivity was higher with unilateral arthroplasties (p = 0.037), with greater contrast differences from background (p < 0.001), and with the SECT 100-kVp technique versus other techniques (p < 0.001). The difference in specificities of modalities was not statistically significant (p = 0.148). CONCLUSION. Combining DECT and SECT techniques does not provide additional benefits for lesion detection as opposed to using SECT alone.


Assuntos
Artefatos , Ligas de Cromo , Prótese Articular , Titânio , Tomografia Computadorizada por Raios X/métodos , Artroplastia , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton
7.
AJR Am J Roentgenol ; 215(2): 441-447, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374669

RESUMO

OBJECTIVE. Cartilage loss on preoperative knee MRI is a predictor of poor outcomes after arthroscopic partial meniscectomy. The purpose of this study was to compare the ability to predict outcomes after arthroscopic partial meniscectomy with a clinically used modified Outerbridge system versus a semiquantitative MRI Osteoarthritis Knee Score system for grading cartilage loss. MATERIALS AND METHODS. Patients who underwent preoperative knee MRI within 6 months of arthroscopic partial meniscectomy and who had outcomes available from the time of surgery and 1 year later were eligible for inclusion. Cases were evaluated by two radiologists and one radiology fellow with the use of both grading systems. The accuracy of each system in discriminating between surgical success and failure was estimated using the ROC curve (AUC) with 95% CIs. A Wald test was used to assess noninferiority of the clinical grading system. Interreader agreement regarding the accuracy of the grading systems in predicting outcomes was also compared. RESULTS. A total of 78 patients (38 women and 40 men; mean age, 56.6 years) were included in the study. A prediction model using clinical grading (AUC = 0.695; 95% CI, 0.566-0.824) was noninferior (p = 0.047) to a model using MRI Osteoarthritis Knee Score grading (AUC = 0.683; 95% CI, 0.539-0.827). Both MRI prediction models performed better than a model using demographic characteristics only (AUC = 0.667; 95% CI, 0.522-0.812). Inter-reader agreement with clinical grading (80.8%) was higher than that with MRI Osteoarthritis Knee Score grading (65.0%; p = 0.012). CONCLUSION. A clinically used system to grade cartilage loss on MRI is as effective as a semiquantitative system for predicting outcomes after arthroscopic partial meniscectomy, while also offering improved interreader agreement.


Assuntos
Artroscopia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Imageamento por Ressonância Magnética , Meniscectomia/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
8.
Skeletal Radiol ; 49(7): 1073-1080, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31996983

RESUMO

OBJECTIVE: To determine whether a 3D magnetic resonance imaging (MRI) sequence with postprocessing applied to simulate computed tomography (CT) ("pseudo-CT") images can be used instead of CT to measure acetabular version and alpha angles and to plan for surgery in patients with femoroacetabular impingement (FAI). MATERIALS AND METHODS: Four readers retrospectively measured acetabular version and alpha angles on MRI and CT images of 40 hips from 20 consecutive patients (9 female patients, 11 male patients; mean age, 26.0 ± 6.5 years) with FAI. 3D models created from MRI and CT images were assessed by 2 orthopedic surgeons to determine the need for femoroplasty and/or acetabuloplasty. Interchangeability of MRI with CT was tested by comparing agreement between 2 readers using CT (intramodality) with agreement between 1 reader using CT and 1 using MRI (intermodality). RESULTS: Intramodality and intermodality agreement values were nearly identical for acetabular version and alpha angle measurements and for surgical planning. Increases in inter-reader disagreement for acetabular version angle, alpha angle, and surgical planning when MRI was substituted for CT were - 2.1% (95% confidence interval [CI], - 7.7 to + 3.5%; p = 0.459), - 0.6% (95% CI, - 8.6 to + 7.3%; p = 0.878), and 0% (95% CI, - 15.1 to + 15.1%; p = 1.0), respectively, when an agreement criterion ≤ 5° was used for angle measurements. CONCLUSION: Pseudo-CT MRI was interchangeable with CT for measuring acetabular version and highly favorable for interchangeability for measuring alpha angle and for surgical planning, suggesting that MRI could replace CT in assessing patients with FAI.


Assuntos
Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Período Pré-Operatório , Estudos Retrospectivos
9.
Skeletal Radiol ; 49(10): 1581-1588, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32382977

RESUMO

OBJECTIVE: The purpose of our study was to determine the cost-effectiveness of radiography and MRI-based imaging strategies for the initial diagnosis of sacroiliitis in a hypothetical population with suspected axial spondyloarthritis. MATERIALS AND METHODS: A decision analytic model from the health care system perspective for patients with inflammatory back pain suggestive of axial spondyloarthritis was used to evaluate the incremental cost-effectiveness of 3 imaging strategies for the sacroiliac joints over a 3-year horizon: radiography, MRI, and radiography followed by MRI. Comprehensive literature search and expert opinion provided input data on cost, probability, and utility estimates. The primary effectiveness outcome was quality-adjusted life-years (QALYs), with a willingness-to-pay threshold set to $100,000/QALY gained (2018 American dollars). RESULTS: Radiography was the least costly strategy ($46,220). Radiography followed by MRI was the most effective strategy over a 3-year course (2.64 QALYs). Radiography was the most cost-effective strategy. MRI-based and radiography followed by MRI-based strategies were not found to be cost-effective imaging options for this patient population. Radiography remained the most cost-effective strategy over all willingness-to-pay thresholds up to $100,000. CONCLUSION: Radiography is the most cost-effective imaging strategy for the initial diagnosis of sacroiliitis in patients with inflammatory back pain suspicious for axial spondyloarthritis.


Assuntos
Sacroileíte , Espondilartrite , Análise Custo-Benefício , Humanos , Imageamento por Ressonância Magnética , Radiografia , Articulação Sacroilíaca/diagnóstico por imagem , Sacroileíte/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem
10.
AJR Am J Roentgenol ; 213(3): 493-505, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31039024

RESUMO

OBJECTIVE. Dual-energy CT (DECT) involves the acquisition of CT attenuation data at two different energy levels. In musculoskeletal imaging, gout detection is the most validated clinical indication for DECT. However, there is emerging evidence for several other clinical musculoskeletal applications, including metal artifact reduction and bone marrow imaging for traumatic, neoplastic, and inflammatory processes. CONCLUSION. In this article, we review the current role of DECT in musculoskeletal imaging, primarily focusing on nongout entities.


Assuntos
Gota/diagnóstico por imagem , Doenças Musculoesqueléticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Artefatos , Doenças da Medula Óssea/diagnóstico por imagem , Humanos , Metais , Próteses e Implantes
11.
Skeletal Radiol ; 48(7): 1095-1102, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30666390

RESUMO

OBJECTIVE: To characterize the appearance, location, severity, and prevalence of focal glenoid retroversion on shoulder MRI in professional baseball pitchers versus age-matched controls. MATERIALS AND METHODS: In this retrospective review, two musculoskeletal radiologists evaluated shoulder MRI examinations from 40 professional baseball pitchers and 40 age-matched controls. Images were scored for the presence of a focal posterior glenoid convexity and the clock face positions involved. A consensus interpretation was also performed. A third reader identified the presence of additional shoulder abnormalities. RESULTS: After consensus, 60% (24/40) of pitchers were found to have focal glenoid retroversion versus 20% (8/40) of controls (p = 0.001). The most apparent location was posterior or posterior-superior, from 7.75 o'clock to 10.5 o'clock (median, 9.75 o'clock; interquartile range, 9.25-10 o'clock). The median clock angle of involvement was greater in pitchers than in controls (30° vs. 0°; p < 0.001). Interreader agreement regarding the presence or absence of focal glenoid retroversion was moderate (Cohen's kappa, 0.49). Focal glenoid retroversion was more prevalent among subjects with additional shoulder abnormalities (p = 0.014). CONCLUSIONS: Glenoid remodeling occurs in the throwing shoulder of professional baseball pitchers and manifests as focally convex morphology of the posterior or posterior-superior glenoid. This type of remodeling does not appear to be associated with a lower prevalence of injuries related to posterior-superior impingement.


Assuntos
Beisebol , Remodelação Óssea , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/diagnóstico por imagem , Beisebol/lesões , Fenômenos Biomecânicos , Estudos de Casos e Controles , Humanos , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Lesões do Ombro , Adulto Jovem
12.
AJR Am J Roentgenol ; 210(6): 1279-1287, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29629805

RESUMO

OBJECTIVE: The purpose of this study was to determine the cost-effectiveness of landmark-based and image-guided intraarticular steroid injections for the initial treatment of a population with adhesive capsulitis. MATERIALS AND METHODS: A decision analytic model from the health care system perspective over a 6-month time frame for 50-year-old patients with clinical findings consistent with adhesive capsulitis was used to evaluate the incremental cost-effectiveness of three techniques for administering intraarticular steroid to the glenohumeral joint: landmark based (also called blind), ultrasound guided, and fluoroscopy guided. Input data on cost, probability, and utility estimates were obtained through a comprehensive literature search and from expert opinion. The primary effectiveness outcome was quality-adjusted life years (QALY). Costs were estimated in 2017 U.S. dollars. RESULTS: Ultrasound-guided injections were the dominant strategy for the base case, because it was the least expensive ($1280) and most effective (0.4096 QALY) strategy of the three options overall. The model was sensitive to the probabilities of getting the steroid into the joint by means of blind, ultrasound-guided, and fluoroscopy-guided techniques and to the costs of the ultrasound-guided and blind techniques. Two-way sensitivity analyses showed that ultrasound-guided injections were favored over blind and fluoroscopy-guided injections over a range of reasonable probabilities and costs. Probabilistic sensitivity analysis showed that ultrasound-guided injections were cost-effective in 44% of simulations, compared with 34% for blind injections and 22% for fluoroscopy-guided injections and over a wide range of willingness-to-pay thresholds. CONCLUSION: Ultrasound-guided injections are the most cost-effective option for the initial steroid-based treatment of patients with adhesive capsulitis. Blind and fluoroscopy-guided injections can also be cost-effective when performed by a clinician likely to accurately administer the medication into the correct location.


Assuntos
Bursite/tratamento farmacológico , Análise Custo-Benefício , Fluoroscopia/economia , Injeções Intra-Articulares/economia , Dor de Ombro/tratamento farmacológico , Esteroides/administração & dosagem , Esteroides/economia , Ultrassonografia de Intervenção/economia , Pontos de Referência Anatômicos , Bursite/diagnóstico por imagem , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Anos de Vida Ajustados por Qualidade de Vida , Dor de Ombro/diagnóstico por imagem , Resultado do Tratamento , Estados Unidos
13.
AJR Am J Roentgenol ; 210(3): 593-600, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29231758

RESUMO

OBJECTIVE: The objective of this study was to compare reader accuracy detecting lesions near hardware in a CT phantom model at different radiation exposures using an advanced metal artifact reduction (MAR) algorithm and standard filtered back projection (FBP) techniques and to determine if radiation exposure could be decreased using MAR without compromising lesion detectability. MATERIALS AND METHODS: A CT phantom manufactured with spherical lesions of various sizes (10-20 mm) and attenuations (20-50 HU) embedded around cobalt-chromium spheres attached to titanium rods, simulating an arthroplasty, was scanned on a single CT scanner (FLASH, Siemens Healthcare) at 140 kVp and 0.6-mm collimation using clinical-dose (300 Quality Reference mAs [Siemens Healthcare]), low-dose (150 Quality Reference mAs), and high-dose (600 Quality Reference mAs) protocols. Images reconstructed with iterative MAR, advanced modeled iterative reconstruction (ADMIRE), and FBP with identical parameters were anonymized and independently reviewed by three radiologists. Accuracies for detecting lesions, measured as AUC, sensitivity, and specificity, were compared. RESULTS: Accuracy using MAR was significantly higher than that using FBP at all exposures (p values ranged from < 0.001 to 0.021). Sensitivity was also higher for MAR than for FBP at all exposures. Specificity was very high for both reconstruction techniques at all exposures with no significant differences. Accuracy of low-dose MAR was higher than and not inferior to standard-dose and high-dose FBP. MAR was significantly more sensitive than FBP in detecting smaller lesions (p = 0.021) and lesions near high streak artifact (p < 0.001). CONCLUSION: MAR improves reader accuracy to detect lesions near hardware and allows significant reductions in radiation exposure without compromising accuracy compared with FBP in a CT phantom model.


Assuntos
Artefatos , Metais , Próteses e Implantes , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas
14.
Skeletal Radiol ; 47(5): 661-669, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29218391

RESUMO

OBJECTIVE: To determine the diagnostic yield of CT-guided percutaneous biopsy of densely sclerotic bone lesions. MATERIALS AND METHODS: We retrospectively analyzed CT-guided percutaneous bone biopsies performed at our institution from September 2008 through August 2011 (329 cases) and from September 2012 through August 2015 (324 cases) after adoption of a battery-powered drill system (OnControl). Bone lesions were included in the analysis if they were >70% sclerotic by visual inspection, had a density > 2 times that of adjacent trabecular bone, and had an attenuation of ≥250 HU. Pathological fractures, diskitis-osteomyelitis, and osteoid osteomas were excluded. Eligible cases were characterized by lesion location, maximum lesion diameter, mean density, biopsy needle type and gauge, reported complications, and histological diagnosis. Clinical and imaging follow-up was used to confirm histological diagnosis. Cases in which a benign histological diagnosis could not be confirmed by imaging over a minimum period of 1 year were excluded. RESULTS: A total of 37 biopsies of sclerotic bone lesions met the inclusion criteria, 17 of which were performed with a power drill needle and 20 of which were performed with a manually driven needle. The mean lesion density was 604.1 HU. The overall diagnostic yield was 78.4%; overall diagnostic accuracy was 94.6%, and the false-negative rate was 5.4%. Diagnostic yield and accuracy were 82.4% and 100% respectively, with a power drill and 75% and 90% respectively, with a manual device. Diagnostic yield for lesions ≥700 HU was 90% (9 out of 10). CONCLUSION: Densely sclerotic bone lesions are amenable to percutaneous needle biopsy.


Assuntos
Doenças Ósseas/patologia , Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Ósseas/diagnóstico por imagem , Doenças Ósseas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Skeletal Radiol ; 47(1): 107-116, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28952012

RESUMO

PURPOSE: To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. MATERIALS AND METHODS: One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. RESULTS: Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. CONCLUSION: A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee.


Assuntos
Traumatismos do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
J Shoulder Elbow Surg ; 27(6): 983-992, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29426742

RESUMO

BACKGROUND: Detection of postoperative component position and implant shift following total shoulder arthroplasty (TSA) can be challenging using routine imaging. The purpose of this study was to evaluate glenoid component position over time using 3-dimensional computed tomography (CT) analysis with minimum 2-year follow-up. METHODS: Twenty patients underwent primary TSA with sequential CT scanning of the shoulder: a preoperative study, an immediate postoperative study within 2 weeks of surgery, and a postoperative study performed at minimum 2-year follow-up (CT3). Postoperative glenoid component position and central peg osteolysis were assessed across the immediate postoperative CT scan and CT3. Glenoids with evidence of component shift and/or grade 1 central peg osteolysis on CT3 were considered at risk of loosening. RESULTS: Of the patients, 7 (35%) showed evidence of glenoid components at risk of loosening on CT3, 6 with component shift (3 with increased inclination alone, 1 with increased retroversion alone, and 2 with both increased inclination and retroversion). Significantly more patients with glenoid component shift had grade 1 central peg osteolysis on CT3 compared with those without shift (83% vs 7%, P = .002). One clinical failure occurred, with the patient undergoing revision to reverse TSA for rotator cuff deficiency. CONCLUSIONS: Three-dimensional CT imaging analysis following TSA identified changes in glenoid component position over time, with inclination being the most common direction of shift and grade 1 central peg osteolysis commonly associated with shift. These findings raise concern for glenoids at risk of loosening, but further follow-up is needed to determine the long-term clinical impact of these findings.


Assuntos
Artroplastia do Ombro , Imageamento Tridimensional , Falha de Prótese , Articulação do Ombro/diagnóstico por imagem , Prótese de Ombro , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Cavidade Glenoide , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Estudos Prospectivos , Articulação do Ombro/cirurgia
17.
Radiology ; 285(1): 101-113, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28604236

RESUMO

Purpose To evaluate the diagnostic accuracies of nonenhanced magnetic resonance (MR) imaging and MR arthrography for diagnosis of superior labrum anterior-to-posterior (SLAP) tears by using a systematic review and meta-analysis. Materials and Methods A comprehensive literature search was performed on the two main concepts of MR imaging (MR imaging, and direct and indirect MR arthrography) and SLAP tears. Inclusion criteria consisted of original studies that assessed the diagnostic accuracy of MR imaging, direct MR arthrography, and/or indirect MR arthrography for the detection of SLAP tears, by using surgical findings as the reference standard. The Quality Assessment of Diagnostic Accuracy Studies 2, or QUADAS-2 Quality Assessment of Diagnostic Accuracy Studies 2 Quality Assessment of Diagnostic Accuracy Studies 2 , tool was used to assess methodologic quality. Meta-analyses were performed that compared MR imaging studies to direct MR arthrography studies and indirect MR arthrography studies, 3-T studies to 1.5-T studies, and low-bias MR imaging studies to low-bias direct MR arthrography studies. Study variation was analyzed by using the Cochran Q test of heterogeneity and the I2 statistic. Results Thirty-two studies met inclusion and exclusion criteria, including 3524 imaging examinations: 1963 direct MR arthrography examinations (23 studies), 1402 MR examinations (14 studies), and 159 indirect MR arthrography examinations (three studies). Twelve studies had low risk for bias, two had questionable risk, and 18 had high risk. Mean sensitivities of direct MR arthrography, MR imaging, and indirect MR arthrography for SLAP tear diagnosis were 80.4%, 63.0%, and 74.2%, respectively. Mean specificities of direct MR arthrography, MR imaging, and indirect MR arthrography were 90.7%, 87.2%, and 66.5%, respectively. Summary receiver operator characteristic (ROC) curve demonstrated superior accuracy of direct MR arthrography compared with those of MR imaging and indirect MR arthrography. Similar findings were observed in the low-bias subanalysis. Summary ROC curve demonstrated overall superiority of 3-T imaging, with or without intra-articular contrast material compared with 1.5-T imaging, with or without intra-articular contrast material. Significant variance was observed for MR imaging and direct MR arthrography (P < .001) studies for both mean sensitivity and specificity. Conclusion Direct MR arthrography appears to be more accurate than nonenhanced MR imaging for diagnosis of SLAP tears, whereas 3-T MR imaging with or without intra-articular contrast material appears to improve diagnostic accuracy compared with 1.5-T MR imaging with or without intra-articular contrast material. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Artrografia , Imageamento por Ressonância Magnética , Lesões do Ombro/diagnóstico por imagem , Adulto , Artrografia/métodos , Artrografia/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Curva ROC , Ombro/diagnóstico por imagem
19.
AJR Am J Roentgenol ; 208(4): W146-W154, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28140650

RESUMO

OBJECTIVE: The purpose of this study was to compare the diagnostic performance of a 5-minute shoulder MRI protocol consisting of multiplanar 2D fast spin-echo (FSE) sequences with parallel imaging to that of a standard shoulder MRI protocol. MATERIALS AND METHODS: A retrospective review of 151 3-T MRI examinations of shoulders of 147 patients (mean age, 46.95 years) and 50 1.5-T MRI examinations of shoulders of 50 patients (mean age, 53.74 years) with four fast and five standard sequences from two academic centers between January 2014 and April 2015 was performed by three musculoskeletal radiologists. Interchangeability of fast and standard MRI was tested by comparing interprotocol (fast vs standard) interreader agreement with standard MRI interreader agreement. Interreader agreement was also compared using kappa statistics. The frequency of major findings was compared using an adjusted McNemar test. Sensitivity and specificity of MRI were measured for 51 patients who underwent surgery. RESULTS: Interprotocol reader agreement was essentially equal to reader agreement on standard MRI (mean difference ≤ 1%; 95% CI, -3.8% to 3.9%; 61-96% across structures). Interprotocol kappa values (0.373-0.645) were similar to standard MRI kappa values (0.320-0.726). Frequencies of major findings on fast and standard MRI were similar (0.7-19.6% across structures; p ≥ 0.08). Sensitivities of fast MRI for tendon and labral tears (33-92%) were equivalent or higher than those of standard MRI with similar specificities (77-98%). CONCLUSION: Fast 5-minute shoulder MRI with multiplanar 2D FSE sequences using parallel imaging is interchangeable, with similar interreader agreement and accuracy, with standard shoulder MRI for evaluating shoulder injuries.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Guias de Prática Clínica como Assunto , Lesões do Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , New York , Variações Dependentes do Observador , Ohio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
20.
Semin Musculoskelet Radiol ; 21(1): 23-31, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28253530

RESUMO

Biostatistics is an essential component in most original research studies in imaging. In this article we discuss five key statistical concepts for study design and analyses in modern imaging research: statistical hypothesis testing, particularly focusing on noninferiority studies; imaging outcomes especially when there is no reference standard; dealing with the multiplicity problem without spending all your study power; relevance of confidence intervals in reporting and interpreting study results; and finally tools for assessing quantitative imaging biomarkers. These concepts are presented first as examples of conversations between investigator and biostatistician, and then more detailed discussions of the statistical concepts follow. Three skeletal radiology examples are used to illustrate the concepts.


Assuntos
Radiologia/estatística & dados numéricos , Projetos de Pesquisa , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa