Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Eur Radiol ; 34(4): 2140-2151, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38379017

RESUMO

Cardiovascular MR imaging has become an indispensable noninvasive tool in diagnosing and monitoring a broad range of cardiovascular diseases. Key to its clinical success and efficiency are appropriate clinical indication triage, technical expertise, patient safety, standardized preparation and execution, quality assurance, efficient post-processing, structured reporting, and communication and clinical integration of findings. Technological advancements are driving faster, more accessible, and cost-effective approaches. This ESR Essentials article presents a ten-step guide for implementing a cardiovascular MR program, covering indication assessments, optimized imaging, post-processing, and detailed reporting. Future goals include streamlined protocols, improved tissue characterization, and automation for greater standardization and efficiency. CLINICAL RELEVANCE STATEMENT: The growing clinical role of cardiovascular MR in risk assessment, diagnosis, and treatment planning highlights the necessity for radiologists to achieve expertise in this modality, advancing precision medicine and healthcare efficiency. KEY POINTS: • Cardiovascular MR is essential in diagnosing and monitoring many acute and chronic cardiovascular pathologies. • Features such as technical expertise, quality assurance, patient safety, and optimized tailored imaging protocols, among others, are essential for a successful cardiovascular MR program. • Ongoing technological advances will push rapid multi-parametric cardiovascular MR, thus improving accessibility, patient comfort, and cost-effectiveness. KEY POINTS: • Cardiovascular MR is essential in diagnosing and monitoring a wide array of cardiovascular pathologies (Level of Evidence: High). • A successful cardiovascular MR program depends on standardization (Level of Evidence: Low). • Future developments will increase the efficiency and accessibility of cardiovascular MR (Level of Evidence: Low).


Assuntos
Doenças Cardiovasculares , Coração , Humanos , Imageamento por Ressonância Magnética/métodos , Doenças Cardiovasculares/diagnóstico por imagem
2.
Eur Radiol ; 34(8): 4874-4882, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38175219

RESUMO

OBJECTIVES: Cardiac motion artifacts hinder the assessment of coronary arteries in coronary computed tomography angiography (CCTA). We investigated the impact of motion compensation reconstruction (MCR) on motion artifacts in CCTA at various heart rates (HR) using a dynamic phantom. MATERIALS AND METHODS: An artificial hollow coronary artery (5-mm diameter lumen) filled with iodinated contrast agent (400 HU at 120 kVp), positioned centrally in an anthropomorphic chest phantom, was scanned using a dual-layer spectral detector CT. The artery was translated at constant horizontal velocities (0-80 mm/s, increment of 10 mm/s). For each velocity, five CCTA scans were repeated using a clinical protocol. Motion artifacts were quantified using the in-plane motion area. Regression analysis was performed to calculate the reduction in motion artifacts provided by MCR, by division of the slopes of non-MCR and MCR fitted lines. RESULTS: Reference mean (95% confidence interval) motion artifact area was 24.9 mm2 (23.8, 26.0). Without MCR, motion artifact areas for velocities exceeding 20 mm/s were significantly larger (up to 57.2 mm2 (40.1, 74.2)) than the reference. With MCR, no significant differences compared to the reference were shown for all velocities, except for 70 mm/s (29.0 mm2 (27.0, 31.0)). The slopes of the fitted data were 0.44 and 0.04 for standard and MCR reconstructions, respectively, resulting in an 11-time motion artifact reduction. CONCLUSION: MCR may improve CCTA assessment in patients by reducing coronary artery motion artifacts, especially in those with elevated HR who cannot receive beta blockers or do not attain the targeted HR. CLINICAL RELEVANCE STATEMENT: This vendor-specific motion compensation reconstruction may improve coronary computed tomography angiography assessment in patients by reduction of coronary artery motion artifacts, especially in those with elevated various heart rates (HR) who cannot receive beta blockers or do not attain the targeted HR. KEY POINTS: • Motion artifacts are known to hinder the assessment of coronary arteries on coronary CT angiography (CCTA), leading to more non-diagnostic scans. • This dynamic phantom study shows that motion compensation reconstruction (MCR) reduces motion artifacts at various velocities, which may help to decrease the number of non-diagnostic scans. • MCR in this study showed to reduce motion artifacts 11-fold.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Vasos Coronários , Imagens de Fantasmas , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Movimento (Física) , Frequência Cardíaca , Processamento de Imagem Assistida por Computador/métodos
3.
Echocardiography ; 41(6): e15849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38837443

RESUMO

Heart failure (HF) is a chronic and progressive disease that often progresses to an advanced stage where conventional therapy is insufficient to relieve patients' symptoms. Despite the availability of advanced therapies such as mechanical circulatory support or heart transplantation, the complexity of defining advanced HF, which requires multiple parameters and multimodality assessment, often leads to delays in referral to dedicated specialists with the result of a worsening prognosis. In this review, we aim to explore the role of cardiac magnetic resonance (CMR) in advanced HF by showing how CMR is useful at every step in managing these patients: from diagnosis to prognostic stratification, hemodynamic evaluation, follow-up and advanced therapies such as heart transplantation. The technical challenges of scanning advanced HF patients, which often require troubleshooting of intracardiac devices and dedicated scans, will be also discussed.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos
4.
Eur Radiol ; 30(5): 2651-2657, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32002643

RESUMO

OBJECTIVE: Little is known about the prevalence and degree of deformation of surgically implanted aortic biological valve prostheses (bio-sAVRs). We assessed bio-sAVR deformation using multidetector-row computed tomography (MDCT). METHODS: Three imaging databases were searched for patients with MDCT performed after bio-sAVR implantation. Minimal and maximal valve ring diameters were obtained in systole and/or diastole, depending on the acquired cardiac phase(s). The eccentricity index (EI) was calculated as a measure of deformation as (1 - (minimal diameter/maximal diameter)) × 100%. EI of < 5% was considered none or trivial deformation, 5-10% mild deformation, and > 10% non-circular. Indications for MDCT and implanted valve type were retrieved. RESULTS: One hundred fifty-two scans of bio-sAVRs were included. One hundred seventeen measurements were performed in systole and 35 in diastole. None or trivial deformation (EI < 5%) was seen in 67/152 (44%) of patients. Mild deformation (EI 5-10%) was seen in 59/152 (39%) and non-circularity was found in 26/152 (17%) of cases. Overall, median EI was 5.5% (IQR 3.4-7.8). In 77 patients, both systolic and diastolic measurements were performed from the same scan. For these scans, the median EI was 6.5% (IQR 3.4-10.2) in systole and 5.1% (IQR3.1-7.6) in diastole, with a significant difference between both groups (p = 0.006). CONCLUSIONS: Surgically implanted aortic biological valve prostheses show mild deformation in 39% of cases and were considered non-circular in 17% of studied valves. KEY POINTS: • Deformation of surgically implanted aortic valve bioprostheses (bio-sAVRs) can be adequately assessed using MDCT. • Bio-sAVRs show at least mild deformation (eccentricity index > 5%) in 56% of studied cases and were considered non-circular (eccentricity index > 10%) in 17% of studied valves. • The higher deformity rate found in bio-sAVRs with (suspected) valve pathology could suggest that geometric deformity may play a role in leaflet malformation and thrombus formation similar to that of transcatheter heart valves.


Assuntos
Valva Aórtica/diagnóstico por imagem , Bioprótese , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Diástole , Implante de Prótese de Valva Cardíaca , Humanos , Tomografia Computadorizada Multidetectores , Falha de Prótese , Sístole , Resultado do Tratamento
5.
Eur Radiol ; 26(4): 997-1006, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26474984

RESUMO

OBJECTIVES: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. METHODS: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. RESULTS: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. CONCLUSIONS: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. KEY POINTS: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Falha de Prótese/efeitos adversos , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Recidiva , Padrões de Referência
6.
Eur Radiol ; 25(12): 3536-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25994194

RESUMO

OBJECTIVE: To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. METHODS: A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. RESULTS: Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. CONCLUSION: Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. KEY POINTS: • Sublingual nitroglycerin administration results in significant coronary artery dilatation. • Nitroglycerin increases the number of evaluable coronary branches. • Image quality is improved the most in smaller coronary branches. • Nitroglycerin increases the diagnostic accuracy of coronary CT angiography. • Most side effects are mild and do not require medical intervention.


Assuntos
Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/diagnóstico por imagem , Nitroglicerina/farmacologia , Tomografia Computadorizada por Raios X , Administração Sublingual , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Nitroglicerina/administração & dosagem
7.
Eur Radiol ; 25(6): 1623-30, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25501272

RESUMO

OBJECTIVES: Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). METHODS: PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. RESULTS: Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. CONCLUSION: MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. KEY POINTS: • Retrospective MDCT is increasingly used for prosthetic heart valve dysfunction assessment • In case of PHV reoperation, invasive coronary angiography is also required • MDCT can replace CAG in 50 % of patients without coronary artery disease • When conclusive for coronary assessment, MDCT stenosis rule out is highly accurate • Replacing CAG saves associated risks of distant embolization of thrombi or vegetations.


Assuntos
Angiografia Coronária/métodos , Análise de Falha de Equipamento/métodos , Próteses Valvulares Cardíacas , Valvas Cardíacas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Reprodutibilidade dos Testes
8.
J Comput Assist Tomogr ; 38(3): 451-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24651757

RESUMO

PURPOSE: The purpose of this study was to compare multidetector-row computed tomography (MDCT) leaflet restriction measurements with fluoroscopy measurements in commonly used mechanical prosthetic heart valves (PHVs). METHODS: Four mechanical PHVs (ON-X, Carbomedics, St. Jude, and Medtronic Hall) were imaged in a pulsatile model using fluoroscopy and 64-detector-row computed tomography. Five image acquisitions of each PHV without (1) and with (4) restricted leaflet closure were made. Three observers measured closure angles on fluoroscopy and MDCT. Data were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman plots. RESULTS: Interobserver agreement was high in restricted and non-restricted leaflets on both modalities (ICCs >0.995). MDCT and fluoroscopy showed high agreements (ICCs >0.989). Median MDCT closure angle measurements differed at most -2 to +2 degrees from fluoroscopy in the restricted and -1 to +2 degrees in the non-restricted leaflets. CONCLUSIONS: MDCT allows measurement of leaflet motion with a maximal median discrepancy of 2 degrees. Both MDCT and fluoroscopy detect restricted leaflet closure with great accuracy.


Assuntos
Fluoroscopia/métodos , Próteses Valvulares Cardíacas , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Análise de Falha de Equipamento/métodos , Fluoroscopia/instrumentação , Humanos , Tomografia Computadorizada Multidetectores/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
IEEE Trans Med Imaging ; 43(4): 1272-1283, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37862273

RESUMO

Coronary artery disease (CAD) remains the leading cause of death worldwide. Patients with suspected CAD undergo coronary CT angiography (CCTA) to evaluate the risk of cardiovascular events and determine the treatment. Clinical analysis of coronary arteries in CCTA comprises the identification of atherosclerotic plaque, as well as the grading of any coronary artery stenosis typically obtained through the CAD-Reporting and Data System (CAD-RADS). This requires analysis of the coronary lumen and plaque. While voxel-wise segmentation is a commonly used approach in various segmentation tasks, it does not guarantee topologically plausible shapes. To address this, in this work, we propose to directly infer surface meshes for coronary artery lumen and plaque based on a centerline prior and use it in the downstream task of CAD-RADS scoring. The method is developed and evaluated using a total of 2407 CCTA scans. Our method achieved lesion-wise volume intraclass correlation coefficients of 0.98, 0.79, and 0.85 for calcified, non-calcified, and total plaque volume respectively. Patient-level CAD-RADS categorization was evaluated on a representative hold-out test set of 300 scans, for which the achieved linearly weighted kappa ( κ ) was 0.75. CAD-RADS categorization on the set of 658 scans from another hospital and scanner led to a κ of 0.71. The results demonstrate that direct inference of coronary artery meshes for lumen and plaque is feasible, and allows for the automated prediction of routinely performed CAD-RADS categorization.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes
10.
JACC Cardiovasc Imaging ; 17(7): 746-762, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38613554

RESUMO

BACKGROUND: The absence of population-stratified cardiovascular magnetic resonance (CMR) reference ranges from large cohorts is a major shortcoming for clinical care. OBJECTIVES: This paper provides age-, sex-, and ethnicity-specific CMR reference ranges for atrial and ventricular metrics from the Healthy Hearts Consortium, an international collaborative comprising 9,088 CMR studies from verified healthy individuals, covering the complete adult age spectrum across both sexes, and with the highest ethnic diversity reported to date. METHODS: CMR studies were analyzed using certified software with batch processing capability (cvi42, version 5.14 prototype, Circle Cardiovascular Imaging) by 2 expert readers. Three segmentation methods (smooth, papillary, anatomic) were used to contour the endocardial and epicardial borders of the ventricles and atria from long- and short-axis cine series. Clinically established ventricular and atrial metrics were extracted and stratified by age, sex, and ethnicity. Variations by segmentation method, scanner vendor, and magnet strength were examined. Reference ranges are reported as 95% prediction intervals. RESULTS: The sample included 4,452 (49.0%) men and 4,636 (51.0%) women with average age of 61.1 ± 12.9 years (range: 18-83 years). Among these, 7,424 (81.7%) were from White, 510 (5.6%) South Asian, 478 (5.3%) mixed/other, 341 (3.7%) Black, and 335 (3.7%) Chinese ethnicities. Images were acquired using 1.5-T (n = 8,779; 96.6%) and 3.0-T (n = 309; 3.4%) scanners from Siemens (n = 8,299; 91.3%), Philips (n = 498; 5.5%), and GE (n = 291, 3.2%). CONCLUSIONS: This work represents a resource with healthy CMR-derived volumetric reference ranges ready for clinical implementation.


Assuntos
Voluntários Saudáveis , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Idoso , Valores de Referência , Adolescente , Adulto Jovem , Idoso de 80 Anos ou mais , Imagem Cinética por Ressonância Magnética/normas , Fatores Sexuais , Fatores Etários , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Etnicidade , Função Ventricular Esquerda , Fatores Raciais
11.
Insights Imaging ; 15(1): 207, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143413

RESUMO

Cardiovascular imaging is exponentially increasing in the diagnosis, risk stratification, and therapeutic management of patients with cardiovascular disease. The European Society of Cardiovascular Radiology (ESCR) is a non-profit scientific medical society dedicated to promoting and coordinating activities in cardiovascular imaging. The purpose of this paper, written by ESCR committees and Executive board members and approved by the ESCR Executive Board and Guidelines committee, is to codify a standardized approach to creating ESCR scientific documents. Indeed, consensus development methods must be adopted to ensure transparent decision-making that optimizes national and global health and reaches a certain scientific credibility. ESCR consensus documents developed based on a rigorous methodology will improve their scientific impact on the management of patients with cardiac involvement. CRITICAL RELEVANCE STATEMENT: This document aims to codify the methodology for producing consensus documents of the ESCR. These ESCR indications will broaden the scientific quality and credibility of further publications and, consequently, the impact on the diagnostic management of patients with cardiac involvement. KEY POINTS: Cardiovascular imaging is exponentially increasing for diagnosis, risk stratification, and therapeutic management. The ESCR is committed to promoting cardiovascular imaging. A rigorous methodology for ESCR consensus documents will improve their scientific impact.

12.
J Clin Med ; 12(19)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37834855

RESUMO

Between 30-40% of patients with cardiac resynchronization therapy (CRT) do not show an improvement in left ventricular (LV) function. It is generally known that patient selection, LV lead implantation location, and device timing optimization are the three main factors that determine CRT response. Research has shown that image-guided CRT placement, which takes into account both anatomical and functional cardiac properties, positively affects the CRT response rate. In current clinical practice, a multimodality imaging approach comprised of echocardiography, cardiac magnetic resonance imaging, or nuclear medicine imaging is used to capture these features. However, with cardiac computed tomography (CT), one has an all-in-one acquisition method for both patient selection and the division of a patient-tailored, image-guided CRT placement strategy. This review discusses the applicability of CT in CRT patient identification, selection, and guided placement, offering insights into potential advancements in optimizing CRT outcomes.

13.
JACC Cardiovasc Imaging ; 15(4): 685-699, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34656482

RESUMO

COVID-19 is associated with myocardial injury caused by ischemia, inflammation, or myocarditis. Cardiovascular magnetic resonance (CMR) is the noninvasive reference standard for cardiac function, structure, and tissue composition. CMR is a potentially valuable diagnostic tool in patients with COVID-19 presenting with myocardial injury and evidence of cardiac dysfunction. Although COVID-19-related myocarditis is likely infrequent, COVID-19-related cardiovascular histopathology findings have been reported in up to 48% of patients, raising the concern for long-term myocardial injury. Studies to date report CMR abnormalities in 26% to 60% of hospitalized patients who have recovered from COVID-19, including functional impairment, myocardial tissue abnormalities, late gadolinium enhancement, or pericardial abnormalities. In athletes post-COVID-19, CMR has detected myocarditis-like abnormalities. In children, multisystem inflammatory syndrome may occur 2 to 6 weeks after infection; associated myocarditis and coronary artery aneurysms are evaluable by CMR. At this time, our understanding of COVID-19-related cardiovascular involvement is incomplete, and multiple studies are planned to evaluate patients with COVID-19 using CMR. In this review, we summarize existing studies of CMR for patients with COVID-19 and present ongoing research. We also provide recommendations for clinical use of CMR for patients with acute symptoms or who are recovering from COVID-19.


Assuntos
COVID-19 , Miocardite , COVID-19/complicações , Criança , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/etiologia , Valor Preditivo dos Testes , SARS-CoV-2 , Síndrome de Resposta Inflamatória Sistêmica
14.
Br J Radiol ; 93(1113): 20200349, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32783626

RESUMO

The aim of this review is to provide an overview of different functional cardiac CT techniques which can be used to supplement assessment of the coronary arteries to establish the significance of coronary artery stenoses. We focus on cine-CT, CT-FFR, CT-myocardial perfusion and how developments in machine learning can supplement these techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Aprendizado de Máquina , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Ensaios Clínicos como Assunto , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico , Humanos , Volume Sistólico , Calcificação Vascular/diagnóstico por imagem , Função Ventricular Esquerda
15.
Radiol Cardiothorac Imaging ; 2(4): e200342, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33778613

RESUMO

PURPOSE: To synthesize the literature on diagnostic test accuracy of chest radiography, CT, and US for the diagnosis of coronavirus disease 2019 (COVID-19) in patients suspected of having COVID-19 in a hospital setting and evaluate the extent of suboptimal reporting and risk of bias. MATERIALS AND METHODS: A systematic search was performed (April 26, 2020) in EMBASE, PubMed, and Cochrane to identify chest radiographic, CT, or US studies in adult patients suspected of having COVID-19, using reverse-transcription polymerase chain reaction test or clinical consensus as the standard of reference. Two × two contingency tables were reconstructed, and test sensitivity, specificity, positive predictive values, and negative predictive values were recalculated. Reporting quality was evaluated by adherence to the Standards for Reporting of Diagnostic Accuracy Studies (STARD), and risk of bias was evaluated by adherence to the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). RESULTS: Thirteen studies were eligible (CT = 12; chest radiography = 1; US = 0). Recalculated CT sensitivity and specificity ranged between 0.57 and 0.97, and 0.37 and 0.94, respectively, and positive predictive values and negative predictive values ranged between 0.59 and 0.92 and 0.57 and 0.96, respectively. On average, studies complied with only 35% of the STARD-guideline items. No study scored low risk of bias for all QUADAS-2 domains (patient selection, index test, reference test, and flow and timing). High risk of bias in more than one domain was scored in 10 of 13 studies (77%). CONCLUSION: Reported CT test accuracy for COVID-19 diagnosis varies substantially. The validity and generalizability of these findings is complicated by poor adherence to reporting guidelines and high risk of bias, which are most likely due to the need for urgent publication of findings in the first months of the COVID-19 pandemic.Supplemental material is available for this article.© RSNA, 2020.

16.
Med Phys ; 47(10): 5048-5060, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32786071

RESUMO

PURPOSE: Deep learning-based whole-heart segmentation in coronary computed tomography angiography (CCTA) allows the extraction of quantitative imaging measures for cardiovascular risk prediction. Automatic extraction of these measures in patients undergoing only non-contrast-enhanced CT (NCCT) scanning would be valuable, but defining a manual reference standard that would allow training a deep learning-based method for whole-heart segmentation in NCCT is challenging, if not impossible. In this work, we leverage dual-energy information provided by a dual-layer detector CT scanner to obtain a reference standard in virtual non-contrast (VNC) CT images mimicking NCCT images, and train a three-dimensional (3D) convolutional neural network (CNN) for the segmentation of VNC as well as NCCT images. METHODS: Eighteen patients were scanned with and without contrast enhancement on a dual-layer detector CT scanner. Contrast-enhanced acquisitions were reconstructed into a CCTA and a perfectly aligned VNC image. In each CCTA image, manual reference segmentations of the left ventricular (LV) myocardium, LV cavity, right ventricle, left atrium, right atrium, ascending aorta, and pulmonary artery trunk were obtained and propagated to the corresponding VNC image. These VNC images and reference segmentations were used to train 3D CNNs in a sixfold cross-validation for automatic segmentation in either VNC images or NCCT images reconstructed from the non-contrast-enhanced acquisition. Automatic segmentation in VNC images was evaluated using the Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD). Automatically determined volumes of the cardiac chambers and LV myocardium in NCCT were compared to reference volumes of the same patient in CCTA by Bland-Altman analysis. An additional independent multivendor multicenter set of single-energy NCCT images from 290 patients was used for qualitative analysis, in which two observers graded segmentations on a five-point scale. RESULTS: Automatic segmentations in VNC images showed good agreement with reference segmentations, with an average DSC of 0.897 ± 0.034 and an average ASSD of 1.42 ± 0.45 mm. Volume differences [95% confidence interval] between automatic NCCT and reference CCTA segmentations were -19 [-67; 30] mL for LV myocardium, -25 [-78; 29] mL for LV cavity, -29 [-73; 14] mL for right ventricle, -20 [-62; 21] mL for left atrium, and -19 [-73; 34] mL for right atrium, respectively. In 214 (74%) NCCT images from the independent multivendor multicenter set, both observers agreed that the automatic segmentation was mostly accurate (grade 3) or better. CONCLUSION: Our automatic method produced accurate whole-heart segmentations in NCCT images using a CNN trained with VNC images from a dual-layer detector CT scanner. This method might enable quantification of additional cardiac measures from NCCT images for improved cardiovascular risk prediction.


Assuntos
Aprendizado Profundo , Angiografia por Tomografia Computadorizada , Coração/diagnóstico por imagem , Humanos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X
18.
PLoS One ; 12(4): e0175714, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28410386

RESUMO

BACKGROUND: To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). METHODS: Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. RESULTS: Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. CONCLUSION: IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Algoritmos , Criança , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
19.
J Cardiovasc Comput Tomogr ; 10(5): 398-406, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27452311

RESUMO

BACKGROUND: In patients with suspected prosthetic heart valve (PHV) dysfunction, routine evaluation echocardiography and fluoroscopy may provide unsatisfactory results for identifying the cause of dysfunction. This study assessed the value of MDCT as a routine, complementary imaging modality in suspected PHV-dysfunction for diagnosing the cause of PHV dysfunction and proposing a treatment strategy. METHODS: Patients with suspected PHV dysfunction were prospectively recruited. All patients underwent routine diagnostic work-up (TTE, TEE ± fluoroscopy) and additional MDCT imaging. An expert panel reviewed all cases and assessed the diagnosis and treatment strategy, first based on routine evaluation only, second with additional MDCT information. RESULTS: Forty-two patients were included with suspected PHV obstruction (n = 30) and PHV regurgitation (n = 12). The addition of MDCT showed incremental value to routine evaluation in 26/30 (87%) cases for detecting the specific cause of PHV obstruction and in 7/12 (58%) regurgitation cases for assessment of complications and surgical planning. The addition of MDCT resulted in treatment strategy change in 8/30 (27%) patients with suspected obstruction and 3/12 (25%) patients with regurgitation. CONCLUSION: In addition to echocardiography and fluoroscopy, MDCT may identify the cause of PHV dysfunction and alter the treatment strategy.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Tomografia Computadorizada Multidetectores , Falha de Prótese , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Técnicas de Imagem de Sincronização Cardíaca , Estudos Transversais , Ecocardiografia Doppler em Cores , Eletrocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Reoperação , Fatores de Risco , Resultado do Tratamento
20.
Eur Heart J Cardiovasc Imaging ; 16(12): 1307-17, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26374879

RESUMO

Accurate annular sizing in transcatheter aortic valve implantation (TAVI) planning is essential. It is now widely recognized that the annulus is an oval structure in most patients, but it remains unclear if the annulus undergoes change in size and shape during the cardiac cycle that may impact prosthesis size selection. Our aim was to assess whether the aortic annulus undergoes dynamic conformational change during the cardiac cycle and to evaluate possible implications for prosthesis size selection. We performed a systematic search in PubMed and Embase databases and reviewed all available literature on aortic annulus measurements in at least two cardiac phases. Twenty-nine articles published from 2001 to 2014 were included. In total, 2021 subjects with and without aortic stenosis were evaluated with a mean age ranging from 11 ± 3.6 to 84.9 ± 7.2 years. Two- and three-dimensional echocardiography was performed in six studies each, magnetic resonance imaging was used in one and computed tomography in 17 studies. In general, the aortic annulus was more circular in systole and predominantly oval in diastole. Whereas the annular long-axis diameter showed insignificant change throughout the cycle, the short-axis diameter, area, and perimeter were significantly larger in systole compared with diastole. Hence, the aortic annulus does undergo dynamic changes during the cardiac cycle. In patients with large conformational changes, diastolic compared with systolic measurements can result in undersizing TAVI prostheses. Due to the complex annular anatomy and dynamic change, three-dimensional assessment in multiple phases has utmost importance in TAVI planning to improve prosthesis sizing.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anatomia & histologia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Desenho de Prótese , Ajuste de Prótese
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa