Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Surg Today ; 52(10): 1453-1462, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35338427

RESUMO

PURPOSE: To establish whether emergency surgery performed outside working hours (after hours) contributed to adverse outcomes for patients with acute type A aortic dissection (ATAAD). METHODS: We reviewed the operation records of ATAAD repair in our institution from 2004 to 2019 (n = 187). Emergency surgery was performed by one of a few teams of experienced surgeons, regardless of the time of day. Patients were divided into two groups based on the surgery start time: during working hours (n = 65) and after hours (n = 122). A propensity score-matched analysis was performed for 58 pairs of patients. RESULTS: The overall in-hospital mortality was 6.9% for the working-hours group and 13.8% for the after-hours group. There were no significant differences between the groups in the relatively limited study population (n = 187). Surgeon experience and aortic interventions did not differ remarkably between the groups. After-hours repair was not associated with postoperative complications. There were no significant differences in the long-term survival or aortic event-free rates between the groups. CONCLUSIONS: After-hours surgery did not affect the short- or long-term outcomes of ATAAD repair under our backup system, which supports the recommendation of immediate surgical repair. Efforts to minimize the discrepancies between working hours and after hours could help to improve the surgical outcomes of patients undergoing ATAAD repair.


Assuntos
Dissecção Aórtica , Doença Aguda , Dissecção Aórtica/complicações , Mortalidade Hospitalar , Humanos , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
2.
Kyobu Geka ; 74(9): 687-691, 2021 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-34446623

RESUMO

The patient was an 81-year-old man. Transcatheter aortic valve implantation( TAVI) was performed for severe aortic stenosis using Evolut R. The patient moved to intensive care unit without an adverse event after the operation. But repeated acute heart failure occurred several times during hospital stay. Mitral regurgitation (MR) was worsened from mild at baseline to moderate or more by transthoracic echocardiography. Various factors that worsened MR after TAVI have been reported, and treatment strategy for severe aortic stenosis patients with MR should be carefully developed.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Kyobu Geka ; 71(5): 361-364, 2018 May.
Artigo em Japonês | MEDLINE | ID: mdl-29755089

RESUMO

A 54-year-old woman was referred for assessment of dysphagia and extrinsic compression of the esophagus detected by upper gastrointestinal endoscopy. Computed tomography revealed the rightsided aortic arch with mirror image branching and Kommerell's diverticulum. To relieve the esophageal compression, surgical intervention was indicated. Descending aortic replacement with a Dacron graft was performed through right thoracotomy under partial cardiopulmonary bypass. The patient was discharged without any complication, and her dysphagia disappeared.


Assuntos
Aorta Torácica/anormalidades , Transtornos de Deglutição/cirurgia , Diverticulose Esofágica/cirurgia , Esôfago , Aorta Torácica/cirurgia , Ponte Cardiopulmonar/métodos , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Transtornos de Deglutição/etiologia , Diverticulose Esofágica/complicações , Diverticulose Esofágica/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Toracotomia , Tomografia Computadorizada por Raios X
5.
Kyobu Geka ; 69(7): 503-5, 2016 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-27365060

RESUMO

We report a rare case of ventricular septal perforation (VSP) after inferior myocardial infarction. Surgical repair of VSP after inferior infarction is technically difficult because of its anatomical location. An 81-year-old female presented with dyspnea on the 8th day after percutaneous coronary intervention for acute inferior myocardial infarction. Echocardiography revealed a ventricular septal perforation. Urgent operation was performed. There was a VSP around the base of the ventricular septum. The myocardial infarction extended to the adjacent muscle of the mitral valve annulus. Two bovine pericardial patches were used in the left ventricular cavity. The patches were sewn on the mitral valve annulus which was the only normal tissue in the region. The 1st patch was used to close the VSP directly, and the 2nd patch was sutured to the normal myocardium to exclude the infracted area. No residual shunt flow was observed. The postoperative course was uneventful.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Pericárdio/transplante , Implantação de Prótese/métodos , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia , Idoso de 80 Anos ou mais , Animais , Bovinos , Feminino , Xenoenxertos , Humanos , Balão Intra-Aórtico , Valva Mitral/patologia , Infarto do Miocárdio/terapia , Resultado do Tratamento , Ruptura do Septo Ventricular/patologia
6.
Cureus ; 16(5): e60276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38872697

RESUMO

Introduction This study aimed to evaluate the sex-specific characteristics and surgical outcomes in patients with acute type A aortic dissection (ATAAD). Materials and methods We reviewed the surgical records of patients who underwent ATAAD repair at our institution between 2004 and 2020 (n=213). Results Of the 213 patients, 100 (46.9%) were male, and 113 (53.1%) were female. Males were younger than females (62.5 vs. 72.9 years, p<0.0001). Females had more nonspecific symptoms (p=0.04), more frequently developed ATAAD before noon (45.0% vs. 53.1%, p=0.01), and had a significantly longer time from onset to surgery (425.1 vs. 595.8 min, p=0.03). The ascending aorta was replaced more frequently in females than in males (54.5% vs. 72.8%, p<0.01). No significant difference was observed in the in-hospital mortality rate between males and females (9.0% vs. 10.6%, p=0.69). The multivariable logistic analysis demonstrated that being male was not an independent predictor of operative mortality (OR, 0.96; 95% CI, 0.18-5.21; p=0.96). At 10 years, males had significantly better long-term survival rates in the unadjusted cohort than females (79.4% vs. 55.9%, p=0.02). Conclusions Male sex was not an independent predictor of early death in patients with ATAAD after surgery, although significant differences were noted in terms of age, onset time, chief complaint, imaging findings, and surgical procedures. A sex-based management strategy involving specific differences should be considered to improve outcomes.

7.
Asian Cardiovasc Thorac Ann ; 31(2): 75-80, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36330614

RESUMO

BACKGROUND: Total arch replacement (TAR) with a frozen elephant trunk (FET) is a common technique for acute aortic dissection, but there is no consensus on the optimal size of the FET. METHODS: Forty-four patients who underwent TAR with FET for acute aortic dissection at our hospital since 2014 were included. The aortic diameter obtained from FET was measured on postoperative computed tomography (CT) and the estimated oversizing ratio was calculated. We investigated the relationship between the estimated oversizing ratio and postoperative outcomes. We also measured the maximum true lumen diameter, circumference of the true lumen, and total aortic diameter at the same level as the FET end on preoperative CT and examined the correlation with the aortic diameter obtained from FET. RESULTS: The average estimated oversizing ratio was 109%. Early postoperative CT showed complete thrombosis of the false lumen in 41 (93.2%) patients. No distal stent graft-induced new entry occurred during follow-up. The correlation coefficients between the three measurements and aortic diameter obtained from FET were 0.64 (maximum true lumen diameter), 0.76 (true lumen diameter calculated from circumference), and 0.72 (total aortic diameter), respectively. CONCLUSIONS: The aortic diameter obtained from FET on postoperative CT was strongly correlated with the true lumen diameter calculated from the circumference and total aortic diameter on preoperative CT. It is reasonable to select a size of approximately 130% of the true lumen diameter calculated from the circumference or 80% to 85% of the total aortic diameter.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Prótese Vascular , Stents , Estudos Retrospectivos , Resultado do Tratamento
8.
J Cardiol Cases ; 25(4): 247-249, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35911067

RESUMO

We herein report a case of leg malperfusion caused by dynamic obstruction after aortic dissection diagnosed by the exercise ankle brachial pressure index test that could not be diagnosed solely by examining the symptoms and investigations at rest. This case suggests that exercise can be a key factor in the diagnosis of this complication. Furthermore, blood pressure elevation can be an exacerbating factor in dynamic obstruction. We recommend conducting an aggressive evaluation of the symptoms and medical examinations not only at rest but also under stress. .

9.
Gen Thorac Cardiovasc Surg ; 69(5): 870-873, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33201384

RESUMO

The patient was a 68-year-old man who underwent triple-vessel OPCAB uneventfully with aortic proximal anastomosis at one site using the saphenous vein with a mechanical device, not a side clamp, with mild traction of the ascending aorta by aortic taping. On postoperative day 7, computed tomography revealed extremely localized AAD with a tear on the posterior wall of the ascending aorta. Emergent ascending aortic replacement was successfully performed. Surprisingly, the tear extended laterally along the traction site of the tape. To our knowledge, this is the first report of AAD early after OPCAB originating at a location other than the sites of proximal anastomosis or side clamping. Proximal anastomosis with a mechanical device to the towed aorta may indirectly or directly injure the intima of the posterior wall, causing this complication. Manipulating the aorta under abnormal pressure should be avoided.


Assuntos
Dissecção Aórtica , Ponte de Artéria Coronária sem Circulação Extracorpórea , Idoso , Anastomose Cirúrgica , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Humanos , Masculino , Veia Safena/diagnóstico por imagem
10.
Ann Vasc Dis ; 13(4): 457-460, 2020 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-33391572

RESUMO

A 75-year-old man underwent emergent endovascular aortic repair for a ruptured abdominal aortic aneurysm. Two years later, computed tomography revealed aneurysm enlargement with endoleaks. Next, late open conversion was performed. Intraoperatively, we detected a spurting type II endoleak from an artery within the aneurysmal wall, which was unconnected to any branch vessels outside the aneurysm, and surgical ligation and sacotomy was performed uneventfully. To our knowledge, this is the first report to intraoperatively identify a type II endoleak from an artery within the aneurysm wall. Even for atypical type II endoleak, such as this case, open surgical repair should be effective.

11.
EJVES Vasc Forum ; 48: 1-4, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33937893

RESUMO

INTRODUCTION: The efficacy of endovascular treatment for complicated Stanford type B acute aortic dissection is being established. However, aortic events sometimes occur, and some cases require surgical intervention. REPORT: A 52 year old man underwent ascending aorta replacement for Stanford type A acute aortic dissection in August 2016. Post-operative computed tomography (CT) showed residual dissection from the aortic arch to the right common iliac artery and a large re-entry in the right common iliac artery (RCIA). Two months after the operation, CT revealed enlargement of the false lumen of the thoracic aorta and the thoracic aortic diameter. Aiming to reduce the false lumen and remodel the aorta, a three stage operation was performed, as described below. Four months after the dissection, total aortic arch replacement and a frozen elephant trunk insertion were performed as the first stage. Subsequently, as a second stage operation, thoracic endovascular repair (TEVAR) was performed using a Zenith® Dissection Endovascular System (Cook Japan Co., Ltd, Tokyo, Japan), with the aim of expanding the true aortic lumen. The implanted devices were a stent graft for the proximal part and two bare stents for the middle and distal part. As a third stage operation, abdominal aortic endovascular treatment was performed with the purpose of closing the re-entry from the RCIA. However, two years after the three stage operation, CT showed that the thoracic aorta was over 60 mm in diameter. Graft replacement of the thoraco-abdominal aorta was performed. The bare stents were expected to be easily removable from the aorta, but unexpectedly, they were strongly attached to the intima, which made it extremely difficult to perform surgical and aortic operations. DISCUSSION: Surgical operations for the aorta can become more difficult after bare stent placement in the aorta.

12.
Ann Vasc Dis ; 8(2): 120-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26131035

RESUMO

Spontaneous isolated dissection of the superior mesenteric artery (SID-SMA) is a rare condition, and there is still no consensus on optimal management. Here, we present three cases of SID-SMA, that were treated by surgical revascularization with urgent iliomesenteric bypass surgery without intestine resection, endovascular therapy with stent placement, and conservative management. The purpose of this study is to review these three cases and propose an algorithm for optimal management of SID-SMA.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa