Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 49(5): 1277-1280, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426992

RESUMO

We investigate the nonlinear dynamics of an optoelectronic oscillator that is implemented with a laser diode (LD) with time-delayed feedback. In this system, electrical-to-optical conversion is directly implemented using the direct modulation of the laser diode itself, instead of an electrooptical modulator as in conventional architectures. Moreover, we consider the cubic nonlinear saturation of the characteristic laser power-intensity (P-I) transfer function far above threshold, instead of its simplified piecewise linear counterpart. We perform the stability analysis of the oscillator, and we show that it displays a rich dynamics that includes quasi-harmonic, relaxation oscillations, and chaos. We also show that the oscillator is strongly hysteretic and displays a wide variety of multistable behaviors, including the rare case of bistability between chaotic attractors. Our analytical and numerical results are found to be in good agreement with the experimental measurements.

2.
Clin Ophthalmol ; 15: 3931-3938, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34594099

RESUMO

PURPOSE: This study analyzes diurnal IOP data (9AM, 12PM, 4PM) from a prospective 12-month trial of the OMNI Surgical System in open-angle glaucoma (OAG) patients with the aim of evaluating effect of MIGS surgery on the amplitude of the diurnal IOP profile pre- and postoperatively. SETTING: Fifteen ophthalmology practices and surgery centers located in 14 states in the United States. DESIGN: Prospective, multicenter, IRB approved study. Patients treated with canaloplasty (360°) and trabeculotomy (180°). Patients had cataract and mild-moderate OAG with intraocular pressure (IOP) ≤33 mmHg on zero to four hypotensive medications. METHODS: Post-hoc analysis of diurnal IOP data from the multicenter GEMINI study. Analysis includes comparison of IOP preoperatively and at month 12 for each of the diurnal time points, 9AM, 12PM, 4PM, change in magnitude of spread between the maximum IOP and minimum IOP for each patient and the proportions of patients preoperatively and at month 12 with IOPs at or below 25, 21, 18, and 15 mmHg, average variability (standard deviation of the 9AM, 12PM, and 4PM IOP) preoperatively and at month 12. RESULTS: A total of 128 patients included in this analysis. IOP at each diurnal timepoint was significantly lower postoperatively (p<0.0001). The difference between highest and lowest IOP measurement for each patient averaged 2.8 mmHg preoperatively (SD 2.4, MAX 14, MIN 0) and 1.8 mmHg (SD 1.7, MAX 10, MIN 0) month 12 (P<0.00001). The proportion with IOP ≤ to 25, 21, 18, and 15 mmHg increased; 75%-97%, 27%-88%, 1%-79%, and <1%-56%, respectively. The average variability was greater at all time points preoperatively (P<0.0001). CONCLUSION: This study demonstrates that eyes with OAG can benefit from an overall decreased IOP and degree of IOP fluctuations for as long as 12 months after surgical treatment with canaloplasty and trabeculotomy.

3.
Artigo em Inglês | MEDLINE | ID: mdl-25679677

RESUMO

In this article, we investigate the dynamical behavior of breathers in optoelectronic oscillators from the standpoint of mixed-mode oscillations. In the phase space, these breathers are composite oscillations that are damped to the attractive branches of an invariant manifold. Our study shows that the emergence of breather dynamics is linked to the apparition of inflection points in the phase space, and we develop an analytical framework based on the Liénard reduction form in order to provide an analytical insight into this phenomenology. Our theoretical results are in excellent agreement with experimental measurements.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa