1.
IEEE Trans Biomed Circuits Syst ; 8(6): 779-86, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25546862

RESUMO

A sub- µW ECG acquisition IC is presented for a single-chamber leadless pacemaker applications. It integrates a low-power, wide dynamic-range ECG readout front end together with an analog QRS-complex extractor. To save ASIC power, a current-multiplexed channel buffer is introduced to drive a 7 b-to-10 b self-synchronized SAR ADC which utilizes 4 fF/unit capacitors. The ASIC consumes only 680nA and achieves CMRR > 90 dB, PSRR > 80 dB, an input-referred noise of 4.9 µVrms in a 130 Hz bandwidth, and has rail-to-rail DC offset rejection. Low-power heartbeat detections are evaluated with the help of the ASIC acquiring nearly 20,000 beats across 10 different records from the MIT-BIH arrhythmia database. In the presence of muscle noise, both the average Sensitivity (Se) and Positive Predictivity (PP) show more than 90% when the input SNR > 6 dB.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Marca-Passo Artificial , Humanos
2.
IEEE Trans Biomed Circuits Syst ; 7(6): 785-95, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24473543

RESUMO

A low-power analog signal processing IC is presented for the low-power heart rhythm analysis. The ASIC features 3 identical, but independent intra-ECG readout channels each equipping an analog QRS feature extractor for low-power consumption and fast diagnosis of the fatal case. A 16-level digitized sine-wave synthesizer together with a synchronous readout circuit can measure bio-impedance in the range of 0.1-4.4 kΩ with 33 mΩ(rms) resolution and higher than 97% accuracy. The proposed 25 mm² ASIC consumes only 13 µA from 2.2 V. It is a highly integrated solution offering all the functionality of acquiring multiple high quality intra-cardiac signals, requiring only a few limited numbers of external passives.


Assuntos
Eletrocardiografia/instrumentação , Eletrônica Médica/instrumentação , Marca-Passo Artificial , Próteses e Implantes , Processamento de Sinais Assistido por Computador/instrumentação , Algoritmos , Desenho de Equipamento , Frequência Cardíaca/fisiologia , Humanos
3.
Anal Cell Pathol (Amst) ; 35(2): 107-15, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22002723

RESUMO

In the field of whole slide imaging, the imaging device or staining process cause color variations for each slide that affect the result of image analysis made by pathologist. In order to stabilize the analysis, we developed a color standardization method and system as described below. (1) Color standardization method based on RGB imaging and multi spectral sensing, which utilize less band (16 bands) than conventional method (60 bands). (2) High speed spectral sensing module. As a result, we confirmed the following effect. (1) We confirmed the performance improvement of nucleus detection by the color standardization. And we can conduct without training data set which is needed in conventional method. (2) We can get detection performance of H&E component equivalent to conventional method (60 bands). And measurement process is more than 255 times faster.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Análise Espectral/normas , Algoritmos , Cor , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Padrões de Referência , Análise Espectral/métodos , Coloração e Rotulagem