Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Card Surg ; 34(6): 404-411, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30958905

RESUMO

BACKGROUND: We sought to identify subgroups of patients at a higher probability of tricuspid annuloplasty (TAP) failure early after surgery. METHODS: From May 2009 to December 2015, 688 patients undergoing TAP for functional tricuspid regurgitation (FTR) at a single institution were included in the study. In all patients, a complete transthoracic echocardiographic evaluation of right ventricle (RV) and tricuspid valve (TV) apparatus was collected. RESULTS: Twenty-six patients (3.8%) died within the first 30 days of surgery. Residual TR after TAP was recorded in 85 (12.4%), moderate in 80 (11.7%) and severe in 5 (0.7%). Preoperative TV apparatus remodeling was associated with residual TR; in particular, the following cutoffs were identified: TV coaptation depth ≥6.5 mm, tenting area ≥0.85 cm2 , and tricuspid annulus ≥35 mm. The entire cohort was stratified in three subsets: patients having preoperative mild/moderate TR without preoperative TV apparatus and/or RV remodeling (n = 178); patients having mild/moderate TR with TV apparatus and/or RV remodeling (n = 317); patients with severe TR regardless of TV apparatus and/or RV remodeling (n = 193). Residual TR was 2.8%, 10.4%, and 24.3%, respectively (P < 0.001). At multivariable analysis, patients showing preoperative mild/moderate TR with TV apparatus and/or RV remodeling as well as patients with severe TR were at significantly higher risk for early failure. No difference was found regarding the type of TV repair performed. CONCLUSIONS: Prophylactic TAP should be encouraged among surgeons even earlier than guidelines recommend, and decision-making for the treatment of low-grade FTR at the time of left-sided valve surgery should take into consideration not only annular size but also tethering severity and RV dilatation.


Assuntos
Anuloplastia da Valva Cardíaca/métodos , Falha de Tratamento , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Adulto , Idoso , Estudos de Coortes , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Índice de Gravidade de Doença , Fatores de Tempo , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Insuficiência da Valva Tricúspide/mortalidade , Remodelação Ventricular
3.
J Clin Med ; 12(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38002708

RESUMO

Redo cardiac surgery after Coronary Artery Bypass Grafting (CABG) is burdened by high morbidity and mortality, either intraoperatively and postoperatively, with the repeated sternotomy playing a crucial role as risk factor. The right minithoracotomy approach guarantees a safer control on conduits integrity and the right ventricular wall and a low impact on the respiratory mechanics. Herein, we report a patient who previously underwent two CABG (coronary artery bypass grafting) procedures and who was admitted to the hospital with a picture of heart failure caused by a severe mitral regurgitation. He was successfully submitted to a mitral valve repair on a beating heart via the right minithoracotomy approach.

4.
J Card Surg ; 24(2): 173-4, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18793240

RESUMO

Bleeding from the anastomotic site is a frequent complication of surgery for acute aortic dissection. Many methods have been devised in order to avoid this problem. We report a simple, easy technique to reinforce the anastomotic sites. One small 4-mm-high ring is cut from the same prosthesis and placed circumferentially inside the aorta edge. Another ring of the same width is opened in a "C" shape, and placed outside the aorta. The conduit was eventually sutured to the aorta in a standard fashion using a running 3-0 polypropylene suture. The final result appeared good with no bleeding, and the rim lines appear clearer and the edges easier to suture because the Dacron is thinner than other used materials (that is, Teflon). In our opinion, this technique is a simple method to reinforce the anastomosis for both proximal and distal aorta.


Assuntos
Anastomose Cirúrgica/métodos , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Polietilenotereftalatos , Anastomose Cirúrgica/efeitos adversos , Humanos
5.
J Card Surg ; 24(1): 57-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18793235

RESUMO

We present a case where we repaired the aortic arch, by the transposition of the left carotid artery to the ascending aorta. A 52-year-old man presented to our department with a penetrating chest wound by a gunshot in the attempt of suicide. The aortic arch and the insertion of the left carotid artery were involved in the lesion. Through sternotomic approach, the aortic arch was repaired in extracorporeal circulation. Left carotid artery was transected to allow easier repair of the arch posterior wall involved in the lesion, and to reduce the danger of residual stenosis. Then, it was translocated to the ascending aorta by interposing a 7-mm Gore-Tex (W.L. Gore & Associates, Flagstaff, AZ, USA) conduit. The patient complicated renal failure and pneumonia in the postoperative period, but eventually he was discharged in good general conditions.


Assuntos
Aorta Torácica/lesões , Artérias Carótidas/cirurgia , Traumatismos Torácicos/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Ferimentos por Arma de Fogo/cirurgia , Aorta Torácica/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/etiologia , Estenose das Carótidas/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos Torácicos/complicações , Traumatismos Torácicos/diagnóstico , Ultrassonografia Doppler , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico
6.
Int J Cardiol ; 252: 39-43, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29174017

RESUMO

OBJECTIVE: To evaluate the additive and independent prognostic value of abnormal right ventricle (aRV) and pulmonary hypertension (PH) in patients undergoing mitral-tricuspid surgery. METHODS: From January 2009 to December 2012, 541 patients underwent mitro-tricuspid surgery. The entire cohort was divided into 6 subgroups: 63 cases had normal RV and no PH (Group A), 180 normal RV but moderate PH (Group B), 101 normal RV but severe PH (Group C), 15 abnormal RV and no-PH (Group D), 86 abnormal RV and moderate PH (Group E) and 96 abnormal RV and severe PH (Group F). RESULTS: Forty-two (7.8%) patients died in hospital due to any cause: 1.6% in group A, 3.9% in group B, 8.9% in group C, 13.3% in group D, 9.3% in group E, 15.6% in group E, p = 0.005. Among 78 patients with no-PH, mortality was significantly higher in patients with aRV (1.6%vs 13.3%. p = 0.03). Among 344 patients with normal RV, mortality was significantly higher in patients with severe PH (1.6% vs 3.9% vs 8.9%. p = 0.03). Comparing the presence of both abnormal RV and severe PH with the remaining patients, mortality was significantly higher in the first group (15.6% 6.1%, p = 0.004). Multivariable analysis confirmed either the independent or the additive role of RV and PH. CONCLUSIONS: In patients undergoing mitral-tricuspid valve surgery, the presence of either RV dysfunction/dilatation or severe pulmonary hypertension, might play an independent prognostic role for mortality. The worst scenario is surely the contemporary presence of both conditions.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/cirurgia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Mortalidade/tendências , Prognóstico , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/cirurgia
7.
Eur J Cardiothorac Surg ; 54(5): 884-888, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29897429

RESUMO

OBJECTIVES: Our goal was to compare the observed and the expected rates of postoperative cerebrovascular accidents (CVA) in a large cohort of consecutive patients undergoing off-pump coronary artery bypass grafting (CABG) using the ∏-circuit as a no-touch technique. METHODS: From January 2001 to May 2016, 3081 patients were consecutively submitted to an off-pump CABG operation using the ∏-circuit. A CVA was defined as a neurological deficit, lasting less (transient ischaemic attack) or more (stroke) than 24 h, diagnosed by a neurologist and confirmed by a computed tomography or magnetic resonance imaging scan of the brain. The primary end point was to compare the observed and the expected rates of CVAs; the latter was obtained using the Society of Thoracic Surgeons' calculator. The secondary end point was to compare the observed and the expected mortality rates using the Society of Thoracic Surgeons' calculator and the prevalence of postoperative complications. Moreover, we identified some subgroups at higher risk. RESULTS: The postoperative rate of CVAs was 0.5% (14 cases): 2 (0.1%) were transient ischaemic attacks and 12 (0.4%) were strokes. The mean expected CVA rate (1.6%) was significantly higher than the observed rate (P < 0.001). None of patients who experienced postoperative CVAs died. The observed mortality was 1.3% (40 patients) vs the expected mortality (2.6%), which was significantly higher (P < 0.001). Multivariable analysis identified age >70 years old, diabetes, extracardiac vasculopathy and chronic renal failure as risk factors for postoperative CVAs. However, in all the subgroups of risk, except for those with chronic renal failure, the use of the ∏-circuit was associated with a low rate of CVAs. CONCLUSIONS: The ∏-circuit should be included as a possible choice among no-touch techniques. The observed rate of CVAs of 75% is lower than the expected rate.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Idoso , Angiografia Coronária , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
8.
J Cardiovasc Med (Hagerstown) ; 19(3): 98-104, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29342024

RESUMO

BACKGROUND: The aim of this retrospective study was to identify clinical, humoral and echocardiographic variables predicting rehospitalization and poor quality of life (QOL) in patients with reduced or mid-range ejection fraction heart failure. METHODS: From 2009 to 2012, 310 patients were admitted having signs and symptoms of heart failure with reduced ejection fraction. All the patients were followed by phone, calling the patients or the referring general practitioner. The Minnesota Living with Heart Failure Questionnaire (MLHFQ) was used as the instrument to evaluate QOL: MLHFQ less than 24 is a good QOL, 24-45 is moderate QOL and more than 45 is poor QOL. The primary event was poor QOL and/or rehospitalization at 4 years. RESULTS: Seventy-nine patients died at median time of 21 months; 4-year survival was 72 ±â€Š3%. Rehospitalization due to heart failure was recorded in 60 cases. Among 231 survivors, MLHFQ score was good in 99 (42%), moderate in 50 (21%) and poor in 88 (37%). Four-year freedom from death, poor QOL or rehospitalization was 51 ±â€Š3%. Multivariable analysis identified the following risk factors: heart rate at discharge at least 70 bpm, ischemic heart disease, atrial fibrillation, hypercholesterolemia, chronic pulmonary disease, N-terminal pro brain natriuretic peptide at discharge, severe tricuspid regurgitation and mitral regurgitation more than moderate. CONCLUSION: Clinical, laboratory and echocardiographic profile is crucial to predict long-term QOL of patients admitted for heart failure.


Assuntos
Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Coração/diagnóstico por imagem , Readmissão do Paciente/estatística & dados numéricos , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Itália/epidemiologia , Masculino , Análise Multivariada , Peptídeo Natriurético Encefálico/sangue , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Inquéritos e Questionários
9.
Asian Cardiovasc Thorac Ann ; 25(6): 446-449, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27117303

RESUMO

Sometimes, patients scheduled for cardiac operations other than coronary artery bypass may be unsuitable for preoperative coronary angiography. We routinely use intraoperative high-resolution epicardial ultrasound to select the proper target for the graft and to check graft anastomosis integrity. We describe 3 patients who could not undergo preoperative coronary angiography for different reasons. In all cases, we discovered significant stenosis in the left anterior descending coronary artery, which required bypass grafting. Intraoperative verification by transit-time flow measurements confirmed the significant stenosis detected by imaging.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Ponte de Artéria Coronária , Circulação Coronária , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença
10.
J Cardiovasc Dev Dis ; 4(4)2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-29367547

RESUMO

The aim of this review article is to summarize current knowledge of the pathophysiology underlying right ventricular failure (RVF), focusing, in particular, on right ventricular assessment and prognosis. The right ventricle (RV) can tolerate volume overload well, but is not able to sustain pressure overload. Right ventricular hypertrophy (RVH), as a response to increased afterload, can be adaptive or maladaptive. The easiest and most common way to assess the RV is by two-dimensional (2D) trans-thoracic echocardiography measuring surrogate indexes, such as tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), and tissue Doppler velocity of the lateral aspect of the tricuspid valvular plane. However, both volumes and function are better estimated by 3D echocardiography and cardiac magnetic resonance (CMR). The prognostic role of the RV in heart failure (HF), pulmonary hypertension (PH), acute myocardial infarction (AMI), and cardiac surgery has been overlooked for many years. However, several recent studies have placed much greater importance on the RV in prognostic assessments. In conclusion, RV dimensions and function should be routinely assessed in cardiovascular disease, as RVF has a significant impact on disease prognosis. In the presence of RVF, different therapeutic approaches, either pharmacological or surgical, may be beneficial.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa