Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Int J Mol Sci ; 22(21)2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34768938

RESUMO

Homocysteine (Hcy) is a non-protein, sulfur-containing amino acid, which is recognized as a possible risk factor for coronary artery and other pathologies when its levels in the blood exceed the normal range of between 5 and 12 µmol/L (hyperhomocysteinemia). At present, standard procedures in laboratory medicine, such as high-performance liquid chromatography (HPLC), are commonly employed for the quantitation of total Hcy (tHcy), i.e., the sum of the protein-bound (oxidized) and free (homocystine plus reduced Hcy) forms, in biological fluids (particularly, serum or plasma). Here, the response of Aerosol Jet-printed organic electrochemical transistors (OECTs), in the presence of either reduced (free) and oxidized Hcy-based solutions, was analyzed. Two different experimental protocols were followed to this end: the former consisting of gold (Au) electrodes' biothiol-induced thiolation, while the latter simply used bare platinum (Pt) electrodes. Electrochemical impedance spectroscopy (EIS) analysis was performed both to validate the gold thiolation protocol and to gain insights into the reduced Hcy sensing mechanism by the Au-gated OECTs, which provided a final limit of detection (LoD) of 80 nM. For the OECT response based on Platinum gate electrodes, on the other hand, a LoD of 180 nM was found in the presence of albumin-bound Hcy, with this being the most abundant oxidized Hcy-form (i.e., the protein-bound form) in physiological fluids. Despite the lack of any biochemical functionalization supporting the response selectivity, the findings discussed in this work highlight the potential role of OECT in the development of low-cost point-of-care (POC) electronic platforms that are suitable for the evaluation, in humans, of Hcy levels within the physiological range and in cases of hyperhomocysteinemia.


Assuntos
Técnicas Eletroquímicas/métodos , Homocisteína/sangue , Hiper-Homocisteinemia/diagnóstico , Transistores Eletrônicos , Espectroscopia Dielétrica , Eletrodos , Ouro/química , Humanos , Hiper-Homocisteinemia/sangue , Platina/química , Sistemas Automatizados de Assistência Junto ao Leito , Impressão Tridimensional
2.
Small ; 15(41): e1902332, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31441219

RESUMO

The perspective of downscaling organic electrochemical transistors (OECTs) in the nanorange is approached by depositing poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) on electrodes with a nanogap designed and fabricated by electromigration induced break junction (EIBJ) technique. The electrical response of the fabricated devices is obtained by acquiring transfer characteristics in order to clarify the specific main characteristics of OECTs with sub-micrometer-sized active channels (nanogap-OECTs). On the basis of their electrical response to different scan times, the nanogap-OECT shows a maximum transconductance unaffected upon changing scan times in the time window from 1 s to 100 µs, meaning that fast varying signals can be easily acquired with unchanged amplifying performance. Hence, the scaling down of the channel size to the nanometer scale leads to a geometrical paradigm that minimizes effects on device response due to the cationic diffusion into the polymeric channel. A comprehensive study of these features is carried out by an electrochemical impedance spectroscopy (EIS) study, complemented by a quantitative analysis made by equivalent circuits. The propagation of a redox front into the polymer bulk due to ionic diffusion also known as the "intercalation pseudocapacitance" is identified as a limiting factor for the transduction dynamics.

3.
Biochim Biophys Acta ; 1830(9): 4374-80, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23295972

RESUMO

BACKGROUND: Organic electrochemical transistors (OECTs), which are becoming more and more promising devices for applications in bioelectronics and nanomedicine, are proposed here as ideally suitable for sensing and real time monitoring of liposome-based structures. This is quite relevant since, currently, the techniques used to investigate liposomal structures, their stability in different environments as well as drug loading and delivery mechanisms, operate basically off-line and/or with pre-prepared sampling. METHODS: OECTs, based on the PEDOT:PSS conductive polymer, have been employed as sensors of liposome-based nanoparticles in electrolyte solutions to assess sensitivity and monitoring capabilities based on ion-to-electron amplified transduction. RESULTS: We demonstrate that OECTs are very efficient, reliable and sensitive devices for detecting liposome-based nanoparticles on a wide dynamic range down to 10(-5)mg/ml (with a lowest detection limit, assessed in real-time monitoring, of 10(-7)mg/ml), thus matching the needs of typical drug loading/drug delivery conditions. They are hence particularly well suited for real-time monitoring of liposomes in solution. Furthermore, OECTs are shown to sense and discriminate successive injection of different liposomes, so that they could be good candidates in quality-control assays or in the pharmaceutical industry. GENERAL SIGNIFICANCE: Drug loading and delivery by liposome-based structures is a fast growing and very promising field that will strongly benefit from real-time, highly sensitive and low cost monitoring of their dynamics in different pharma and biomedical environments, with a particular reference to the pharmaceutical and production processes, where a major issue is monitoring and measuring the formation and concentration of liposomes and the relative drug load. The demonstrated ability to sense and monitor complex bio-structures, such as liposomes, paves the way for very promising developments in biosensing and nanomedicine. This article is part of a Special Issue entitled Organic Bioelectronics-Novel Applications in Biomedicine.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Lipossomos/química , Microfluídica/instrumentação , Microfluídica/métodos , Transistores Eletrônicos , Nanomedicina/instrumentação , Nanomedicina/métodos , Nanopartículas/química , Polímeros/química , Poliestirenos/química , Soluções/química , Tiofenos/química
4.
Nanotechnology ; 25(48): 485703, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25388936

RESUMO

The capability of efficiently injecting charge carriers into organic films and finely tuning their morphology and structure is crucial to improve the performance of organic thin film transistors (OTFTs). In this work, we investigate OTFTs employing carbon nanotubes (CNTs) as the source-drain electrodes and, as the organic semiconductor, thin films of titanyl phthalocyanine (TiOPc) grown by supersonic molecular beam deposition (SuMBD). While CNT electrodes have shown an unprecedented ability to improve charge injection in OTFTs, SuMBD is an effective technique to tune film morphology and structure. Varying the substrate temperature during deposition, we were able to grow both amorphous (low substrate temperature) and polycrystalline (high substrate temperature) films of TiOPc. Regardless of the film morphology and structure, CNT electrodes led to superior charge injection and transport performance with respect to benchmark Au electrodes. Vacuum annealing of polycrystalline TiOPc films with CNT electrodes yielded ambipolar OTFTs.


Assuntos
Indóis/química , Nanotubos de Carbono/química , Compostos Organometálicos/química , Eletrodos , Semicondutores , Temperatura , Transistores Eletrônicos
5.
Chemosphere ; 359: 142314, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38735489

RESUMO

Continuously growing adoption of electronic devices in energy storage, human health and environmental monitoring systems increases demand for cost-effective, lightweight, comfortable, and highly efficient functional structures. In this regard, the recycling and reuse of polyethylene terephthalate (PET) waste in the aforementioned fields due to its excellent mechanical properties and chemical resistance is an effective solution to reduce plastic waste. Herein, we review recent advances in synthesis procedures and research studies on the integration of PET into energy storage (Li-ion batteries) and the detection of gaseous and biological species. The operating principles of such systems are described and the role of recycled PET for various types of architectures is discussed. Modifying the composition, crystallinity, surface porosity, and polar surface functional groups of PET are important factors for tuning its features as the active or substrate material in biological and gas sensors. The findings indicate that conceptually new pathways to the study are opened up for the effective application of recycled PET in the design of Li-ion batteries, as well as biochemical and catalytic detection systems. The current challenges in these fields are also presented with perspectives on the opportunities that may enable a circular economy in PET use.


Assuntos
Técnicas Biossensoriais , Fontes de Energia Elétrica , Gases , Polietilenotereftalatos , Reciclagem , Polietilenotereftalatos/química , Técnicas Biossensoriais/métodos , Gases/análise , Monitoramento Ambiental/métodos
6.
RSC Adv ; 14(37): 27288-27297, 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39219844

RESUMO

The design and development of engineered micro and nano-carriers offering superior therapeutic performance compared to traditional delivery forms, are crucial in pharmaceutical research. Aerosolization and inhalation of carriers with improved solubility/stability of insoluble drugs, has huge potential for targeted drug delivery (DD) in various pulmonary diseases. Indeed, dedicated carriers must meet specific dimensional rules for proper lung delivery. Particles between 2-10 µm in size are normally deposited in the tracheobronchial region, while particles of 0.5-2 µm may be properly deposited in the alveoli. In this work, we report the development of inhalable nanostructured carries made of a 'green' bio-inspired polymer from aqueous solutions, i.e. silk fibroin (SF), efficiently loaded with a hydrophobic drug, i.e. the thyroid hormone levothyroxine (L-T4), a drug for the treatment of idiopathic pulmonary fibrosis. The aim is to optimize a standard method for the synthesis of SF-based nanocarriers with controlled size and shape, where a fine control of their geometrical properties is aimed at efficiently controlling the pulmonary DD. L-T4 loaded SF particles were synthesized through a one-pot co-precipitation method. Optimized systems were determined by varying the chemo-physical parameters during the synthesis. Ethylenediaminetetraacetic acid (EDTA) was used to remove CaCO3 cores. The proposed synthesis routes have led to two SF structures, whose structural heterogeneity and nanostructured morphology have been demonstrated using fluorescence microscopy, DLS, SEM and EDX. Two systems with varying shape and size have been obtained: (i) a flat disk-like SF structure with an irregular surface and an in-plane length of about 1-2 µm; (ii) solid SF nanospheres, obtained using ethylene glycol as additive, showing two size populations (main diameters of 0.5 µm and 1.7 µm). Solid nanospherical systems, in particular, show a tendency to arrange into agglomerates that, when loosely bound into smaller particles, can facilitate the delivery at the alveoli. Both formulations exhibited similar drug loading efficiencies, evaluated by HPLC analysis. However, SF nanospheres showed greater in vitro drug release after 24 hours. The demonstrated control over the characteristics imparted to the proposed DD systems may be critical to select the most suitable size/shape to achieve high rates of delivery to the appropriate lung compartment.

7.
Bioengineering (Basel) ; 11(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391652

RESUMO

The golden rule in tissue engineering is the creation of a synthetic device that simulates the native tissue, thus leading to the proper restoration of its anatomical and functional integrity, avoiding the limitations related to approaches based on autografts and allografts. The emergence of synthetic biocompatible materials has led to the production of innovative scaffolds that, if combined with cells and/or bioactive molecules, can improve tissue regeneration. In the last decade, silk fibroin (SF) has gained attention as a promising biomaterial in regenerative medicine due to its enhanced bio/cytocompatibility, chemical stability, and mechanical properties. Moreover, the possibility to produce advanced medical tools such as films, fibers, hydrogels, 3D porous scaffolds, non-woven scaffolds, particles or composite materials from a raw aqueous solution emphasizes the versatility of SF. Such devices are capable of meeting the most diverse tissue needs; hence, they represent an innovative clinical solution for the treatment of bone/cartilage, the cardiovascular system, neural, skin, and pancreatic tissue regeneration, as well as for many other biomedical applications. The present narrative review encompasses topics such as (i) the most interesting features of SF-based biomaterials, bare SF's biological nature and structural features, and comprehending the related chemo-physical properties and techniques used to produce the desired formulations of SF; (ii) the different applications of SF-based biomaterials and their related composite structures, discussing their biocompatibility and effectiveness in the medical field. Particularly, applications in regenerative medicine are also analyzed herein to highlight the different therapeutic strategies applied to various body sectors.

8.
Sci Rep ; 13(1): 9367, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37296164

RESUMO

A kombucha is a tea and sugar fermented by over sixty kinds of yeasts and bacteria. This symbiotic community produces kombucha mats, which are cellulose-based hydrogels. The kombucha mats can be used as an alternative to animal leather in industry and fashion once they have been dried and cured. Prior to this study, we demonstrated that living kombucha mats display dynamic electrical activity and distinct stimulating responses. For use in organic textiles, cured mats of kombucha are inert. To make kombucha wearables functional, it is necessary to incorporate electrical circuits. We demonstrate that creating electrical conductors on kombucha mats is possible. After repeated bending and stretching, the circuits maintain their functionality. In addition, the abilities and electronic properties of the proposed kombucha, such as being lighter, less expensive, and more flexible than conventional electronic systems, pave the way for their use in a diverse range of applications.


Assuntos
Bactérias , Leveduras , Animais , Fermentação , Chá/microbiologia
9.
Biosensors (Basel) ; 13(3)2023 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-36979584

RESUMO

Lab-on-a-chip (LOC) systems are miniaturized devices aimed to perform one or several analyses, normally carried out in a laboratory setting, on a single chip. LOC systems have a wide application range, including diagnosis and clinical biochemistry. In a clinical setting, LOC systems can be associated with the Point-of-Care Testing (POCT) definition. POCT circumvents several steps in central laboratory testing, including specimen transportation and processing, resulting in a faster turnaround time. Provider access to rapid test results allows for prompt medical decision making, which can lead to improved patient outcomes, operational efficiencies, patient satisfaction, and even cost savings. These features are particularly attractive for healthcare settings dealing with complicated patients, such as those affected by chronic kidney disease (CKD). CKD is a pathological condition characterized by progressive and irreversible structural or functional kidney impairment lasting for more than three months. The disease displays an unavoidable tendency to progress to End Stage Renal Disease (ESRD), thus requiring renal replacement therapy, usually dialysis, and transplant. Cardiovascular disease (CVD) is the major cause of death in CKD, with a cardiovascular risk ten times higher in these patients than the rate observed in healthy subjects. The gradual decline of the kidney leads to the accumulation of uremic solutes, with negative effect on organs, especially on the cardiovascular system. The possibility to monitor CKD patients by using non-invasive and low-cost approaches could give advantages both to the patient outcome and sanitary costs. Despite their numerous advantages, POCT application in CKD management is not very common, even if a number of devices aimed at monitoring the CKD have been demonstrated worldwide at the lab scale by basic studies (low Technology Readiness Level, TRL). The reasons are related to both technological and clinical aspects. In this review, the main technologies for the design of LOCs are reported, as well as the available POCT devices for CKD monitoring, with a special focus on the most recent reliable applications in this field. Moreover, the current challenges in design and applications of LOCs in the clinical setting are briefly discussed.


Assuntos
Doenças Cardiovasculares , Falência Renal Crônica , Insuficiência Renal Crônica , Humanos , Seguimentos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Dispositivos Lab-On-A-Chip
10.
Micromachines (Basel) ; 14(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36838160

RESUMO

In recent years, studies concerning Organic Bioelectronics have had a constant growth due to the interest in disciplines such as medicine, biology and food safety in connecting the digital world with the biological one. Specific interests can be found in organic neuromorphic devices and organic transistor sensors, which are rapidly growing due to their low cost, high sensitivity and biocompatibility. This trend is evident in the literature produced in Italy, which is full of breakthrough papers concerning organic transistors-based sensors and organic neuromorphic devices. Therefore, this review focuses on analyzing the Italian production in this field, its trend and possible future evolutions.

11.
Polymers (Basel) ; 13(4)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670792

RESUMO

The production of 3D printed safety protection devices (SPD) requires particular attention to the material selection and to the evaluation of mechanical resistance, biological safety and surface roughness related to the accumulation of bacteria and viruses. We explored the possibility to adopt additive manufacturing technologies for the production of respirator masks, responding to the sudden demand of SPDs caused by the emergency scenario of the pandemic spread of SARS-COV-2. In this study, we developed different prototypes of masks, exclusively applying basic additive manufacturing technologies like fused deposition modeling (FDM) and droplet-based precision extrusion deposition (db-PED) to common food packaging materials. We analyzed the resulting mechanical characteristics, biological safety (cell adhesion and viability), surface roughness and resistance to dissolution, before and after the cleaning and disinfection phases. We showed that masks 3D printed with home-grade printing equipment have similar performances compared to the industrial-grade ones, and furthermore we obtained a perfect face fit by customizing their shape. Finally, we developed novel approaches to the additive manufacturing post-processing phases essential to assure human safety in the production of 3D printed custom medical devices.

12.
Materials (Basel) ; 12(8)2019 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-31027275

RESUMO

This work aims to show the feasibility of an innovative approach for the manufacturing of organic-based devices with a true three-dimensional and customizable structure that is made possible by plastic templates, fabricated by additive manufacturing methods, and coated by conducting organic thin films. Specifically, a three-dimensional prototype based on a polyamide structure covered by poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) using the dip-coating technique demonstrated a multifunctional character. The prototype is indeed able to operate both as a three-terminal device showing the typical response of organic electrochemical transistors (OECTs), with a higher amplification performance with respect to planar (2D) all-PEDOT:PSS OECTs, and as a two-terminal device able to efficiently implement a resistive sensing of water vaporization and perspiration, showing performances at least comparable to that of state-of-art resistive humidity sensors based on pristine PEDOT:PSS. To our knowledge, this is the first reported proof-of-concept of a true 3D structured OECT, obtained by exploiting a Selective laser sintering approach that, though simple in terms of 3D layout, paves the way for the integration of sensors based on OECTs into three-dimensional objects in various application areas.

14.
J Mater Chem B ; 6(33): 5400-5406, 2018 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-32254503

RESUMO

We demonstrate the label-free and selective detection of interleukin-6 (IL-6), a key cell-signaling molecule in biology and medicine, by integrating an OECT with an immuno-affinity regenerated cellulose membrane. The objective of the membrane is to increase the local concentration of IL-6 at the sensing electrode and, thereby, enhance the device response for concentrations falling within the physiological concentration range of cytokines. The OECT gate electrode is functionalized with an oligo(ethylene glycol)-terminated self-assembled alkanethiolate monolayer (SAM) for both the immobilization of anti IL-6 antibodies and the inhibition of non-specific biomolecule binding. The OECT gate/electrolyte interface is exploited for the selective detection of IL-6 through the monitoring of antigen-antibody binding events occurring at the gate electrode.

15.
Materials (Basel) ; 12(1)2018 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-30577510

RESUMO

Organic electrochemical transistors (OECTs) represent a powerful and versatile type of organic-based device, widely used in biosensing and bioelectronics due to potential advantages in terms of cost, sensitivity, and system integration. The benchmark organic semiconductor they are based on is poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), the electrical properties of which are reported to be strongly dependent on film morphology and structure. In particular, the literature demonstrates that film processing induces morphostructural changes in terms of conformational rearrangements in the PEDOT:PSS in-plane phase segregation and out-of-plane vertical separation between adjacent PEDOT-rich domains. Here, taking into account these indications, we show the thickness-dependent operation of OECTs, contextualizing it in terms of the role played by PEDOT:PSS film thickness in promoting film microstructure tuning upon controlled-atmosphere long-lasting thermal annealing (LTA). To do this, we compared the LTA-OECT response to that of OECTs with comparable channel thicknesses that were exposed to a rapid thermal annealing (RTA). We show that the LTA process on thicker films provided OECTs with an enhanced amplification capability. Conversely, on lower thicknesses, the LTA process induced a higher charge carrier modulation when the device was operated in sensing mode. The provided experimental characterization also shows how to optimize the OECT response by combining the control of the microstructure via solution processing and the effect of postdeposition processing.

16.
Front Neurosci ; 9: 521, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26834546

RESUMO

The design of electrodes based on conductive polymers in brain-machine interface technology offers the opportunity to exploit variably manufactured materials to reduce gliosis, indeed the most common brain response to chronically implanted neural electrodes. In fact, the use of conductive polymers, finely tailored in their physical-chemical properties, might result in electrodes with improved adaptability to the brain tissue and increased charge-transfer efficiency. Here we interfaced poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) ( PEDOT: PSS) doped with different amounts of ethylene glycol (EG) with rat hippocampal primary cultures grown for 3 weeks on these synthetic substrates. We used immunofluorescence and scanning electron microscopy (SEM) combined to single cell electrophysiology to assess the biocompatibility of PEDOT: PSS in terms of neuronal growth and synapse formation. We investigated neuronal morphology, density and electrical activity. We reported the novel observation that opposite to neurons, glial cell density was progressively reduced, hinting at the ability of this material to down regulate glial reaction. Thus, PEDOT: PSS is an attractive candidate for the design of new implantable electrodes, controlling the extent of glial reactivity without affecting neuronal viability and function.

17.
Biosens Bioelectron ; 68: 791-797, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25687585

RESUMO

We propose and demonstrate a sensitive diagnostic device based on an Organic Electrochemical Transistor (OECT) for direct in-vitro monitoring cell death. The system efficiently monitors cell death dynamics, being able to detect signals related to specific death mechanisms, namely necrosis or early/late apoptosis, demonstrating a reproducible correlation between the OECT electrical response and the trends of standard cell death assays. The innovative design of the Twell-OECT system has been modeled to better correlate electrical signals with cell death dynamics. To qualify the device, we used a human lung adenocarcinoma cell line (A549) that was cultivated on the micro-porous membrane of a Transwell (Twell) support, and exposed to the anticancer drug doxorubicin. Time-dependent and dose-dependent dynamics of A549 cells exposed to doxorubicin are evaluated by monitoring cell death upon exposure to a range of doses and times that fully covers the protocols used in cancer treatment. The demonstrated ability to directly monitor cell stress and death dynamics upon drug exposure using simple electronic devices and, possibly, achieving selectivity to different cell dynamics is of great interest for several application fields, including toxicology, pharmacology, and therapeutics.


Assuntos
Apoptose , Técnicas Biossensoriais , Técnicas Eletroquímicas , Adenocarcinoma/diagnóstico , Adenocarcinoma de Pulmão , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Humanos , Neoplasias Pulmonares/diagnóstico
18.
J Mater Chem B ; 2(34): 5620-5626, 2014 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32262196

RESUMO

Selective detection of bioanalytes in physiological fluids, such as blood, sweat or saliva, by means of low-cost and non-invasive devices, is of crucial importance to improve diagnosis and prevention in healthcare. To be really useful in everyday life a sensing system needs to be handy, non-invasive, easy to read and possibly wearable. Only a sensor that satisfies these requirements could be eligible for applications in healthcare and physiological condition monitoring. Herein an organic electrochemical transistor has been investigated as a simple, low-cost and e-textile biosensor, fully integrated on a single cotton yarn. The biosensor has been used for real-time detection of adrenaline, selectively compared to the saline content in human physiological fluids. The sensing mechanism is based on the oxidation of adrenaline at the Pt-gate electrode surface, with the formation of adrenaline-quinone and adrenochrome. Two independent organic electrochemical transistors, characterized by different gate-electrode materials, detect saline and adrenaline concentrations, respectively, in real human sweat. Measurements performed in real-time mode show the complete independence of adrenaline detection from NaCl and, hence, guarantee the simultaneous monitoring of both concentrations. The oxidation of adrenaline has been studied by means of absorption spectroscopy in air, with either silver or platinum working electrodes. Our results confirm that the oxidation reaction driven by the Pt-electrode leads to the formation of adrenochrome, while with the Ag-electrode the oxidation is similar to the spontaneous one occurring in air. The cotton-based biosensor shows the possibility of monitoring human performances (hydration and stress) in situ and using a non-invasive approach, opening new unexplored opportunities in healthcare, fitness and work safety.

19.
Biomed Res Int ; 2014: 302694, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24579079

RESUMO

Superhydrophobic surfaces are bioinspired, nanotechnology artifacts, which feature a reduced friction coefficient, whereby they can be used for a number of very practical applications including, on the medical side, the manipulation of biological solutions. In this work, we integrated superhydrophobic patterns with the conducting polymer PEDOT:PSS, one of the most used polymers in organic electronics because highly sensitive to ionized species in solution. In doing so, we combined geometry and materials science to obtain an advanced device where, on account of the superhydrophobicity of the system, the solutions of interest can be manipulated and, on account of the conductive PEDOT:PSS polymer, the charged molecules dispersed inside can be quantitatively measured. This original substrate preparation allowed to perform electrochemical measurements on ionized species in solution with decreasing concentration down to 10(-7) molar. Moreover, it was demonstrated the ability of the device of realizing specific, combined time and space resolved analysis of the sample. Collectively, these results demonstrate how a tight, interweaving integration of different disciplines can provide realistic tools for the detection of pathologies. The scheme here introduced offers breakthrough capabilities that are expected to radically improve both the pace and the productivity of biomedical research, creating an access revolution.


Assuntos
Condutividade Elétrica , Interações Hidrofóbicas e Hidrofílicas , Microtecnologia/métodos , Polímeros/química , Poliestirenos/química , Tiofenos/química , Transistores Eletrônicos , Técnicas Biossensoriais , Cloretos/química , Microscopia Eletrônica de Varredura , Cloreto de Potássio/química , Soluções , Compostos de Zinco/química
20.
J Mater Chem B ; 1(31): 3843-3849, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32261138

RESUMO

Organic electrochemical transistors (OECTs) are currently emerging as powerful tools for biosensing, bioelectronics and nanomedical applications owing to their ability to operate under liquid phase conditions optimally integrating electronic and biological systems. Herein we disclose the unique potential of OECTs for detecting and investigating the electrical properties of insoluble eumelanin biopolymers. Gate current measurements on fine aqueous suspensions of a synthetic eumelanin sample from 5,6-dihydroxyindole (DHI) revealed a well detectable hysteretic response similar to that of the pure monomer in solution, with the formal concentration of the polymer as low as 10-6 M. Induction of the gate current would reflect electron transfer from solid eumelanin to the Pt-electrode sustained by redox active catechol/quinone components of the polymer. A gradual decrease in gate current and areas subtended by hysteretic loops were observed over 5 cycles both in the eumelanin- and DHI-based devices, suggesting evolution of the polymer from a far-from-the-equilibrium redox state toward a more stable electronic arrangement promoted by redox exchange with the gate electrode. OECTs are thus proposed as valuable tools for the efficient heterogeneous-phase sensing of eumelanins and to gauge their peculiar electrical and redox behaviour.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa