Blood Transfus ; 11(3): 377-84, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23736930

RESUMO

BACKGROUND: Transfusion therapy remains the main treatment for patients with severe haemoglobinopathies, but can cause adverse reactions which may be classified as immediate or delayed. The use of targeted prevention with drugs and treatments of blood components in selected patients can contribute to reducing the development of some reactions.The aim of our study was to develop an algorithm capable of guiding behaviours to adopt in order to reduce the incidence of immediate transfusion reactions. MATERIALS AND METHODS: Immediate transfusion reactions occurring over a 7-year period in 81 patients with transfusion-dependent haemoglobinopathies were recorded. The patients received transfusions with red cell concentrates that had been filtered prestorage. Various measures were undertaken to prevent transfusion reactions: leucoreduction, washing the red blood cells, prophylactic administration of an antihistamine (loratidine 10 mg tablet) or an antipyretic (paracetamol 500 mg tablet). RESULTS: Over the study period 20,668 red cell concentrates were transfused and 64 adverse transfusion reactions were recorded in 36 patients. The mean incidence of reactions in the 7 years of observation was 3.1‰. Over the years the incidence gradually decreased from 6.8‰ in 2004 to 0.9‰ in 2010. DISCUSSION: Preventive measures are not required for patients who have an occasional reaction, because the probability that such a type of reaction recurs is very low. In contrast, the targeted use of drugs such as loratidine or paracetamol, sometimes combined with washing and/or double filtration of red blood cells, can reduce the rate of recurrent (allergic) reactions to about 0.9‰. The system for detecting adverse reactions and training staff involved in transfusion therapy are critical points for reliable collection of data and standardisation of the detection system is recommended for those wanting to monitor the incidence of all adverse reactions, including minor ones.


Assuntos
Acetaminofen/administração & dosagem , Antipiréticos/administração & dosagem , Transfusão de Eritrócitos/efeitos adversos , Hemoglobinopatias/terapia , Antagonistas dos Receptores Histamínicos/administração & dosagem , Hipersensibilidade/prevenção & controle , Procedimentos de Redução de Leucócitos , Algoritmos , Feminino , Seguimentos , Humanos , Hipersensibilidade/diagnóstico , Hipersensibilidade/etiologia , Masculino , Estudos Retrospectivos
2.
Blood Transfus ; 7(3): 193-203, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19657483

RESUMO

BACKGROUND: One of the most serious risks of blood transfusions is an error in ABO blood group compatibility, which can cause a haemolytic transfusion reaction and, in the most severe cases, the death of the patient. The frequency and type of errors observed suggest that these are inevitable, in that mistakes are inherent to human nature, unless significant changes, including the use of computerised instruments, are made to procedures. METHODS: In order to identify patients who are candidates for the transfusion of blood components and to guarantee the traceability of the transfusion, the Securblood system (BBS srl) was introduced. This system records the various stages of the transfusion process, the health care workers involved and any immediate transfusion reactions. The patients and staff are identified by fingerprinting or a bar code. The system was implemented within Ragusa hospital in 16 operative units (ordinary wards, day hospital, operating theatres). RESULTS: In the period from August 2007 to July 2008, 7282 blood components were transfused within the hospital, of which 5606 (77%) using the Securblood system. Overall, 1777 patients were transfused. In this year of experience, no transfusion errors were recorded and each blood component was transfused to the right patient. We recorded 33 blocks of the terminals (involving 0.6% of the transfused blood components) which required the intervention of staff from the Service of Immunohaematology and Transfusion Medicine (SIMT). Most of the blocks were due to procedural errors. CONCLUSIONS: The Securblood system guarantees complete traceability of the transfusion process outside the SIMT and eliminates the possibility of mistaken identification of patients or blood components. The use of fingerprinting to identify health care staff (nurses and doctors) and patients obliges the staff to carry out the identification procedures directly in the presence of the patient and guarantees the presence of the doctor at the start of the transfusion.


Assuntos
Transfusão de Componentes Sanguíneos , Dermatoglifia , Processamento Eletrônico de Dados/instrumentação , Processamento Eletrônico de Dados/métodos , Sistemas Computadorizados de Registros Médicos/instrumentação , Feminino , Humanos , Masculino