Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Acad Psychiatry ; 43(1): 6-12, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30443864

RESUMO

OBJECTIVES: The primary aim of this study was to evaluate the impact of an experience-based, longitudinal psychiatry training program in a Family Medicine residency on residents' attitudes toward depression and psychiatry. The secondary aim was to identify background predictor variables of changes in attitudes. METHODS: Pre- and post-training surveys were prospectively conducted on attitudes toward depression and psychiatry on Family Medicine residents undergoing an experience-based, longitudinal psychiatry training program. The primary outcome measures were pre- and post-training Depression Attitude Questionnaire (DAQ) and Modified Attitudes to Psychiatry Scale (mAPS) scores. Regression analysis was carried out to determine background variables predictive of improvement in DAQ and/or mAPS scores post-training. RESULTS: Sixty-three Family Medicine residents (100% response rate) responded to the pre-training surveys. All 63 subjects completed the post-training surveys (100% retention rate). There was significant improvement in DAQ and mAPS scores post-training, indicating better attitudes toward depression and psychiatry. Significant improvement was observed in 8 out of 13 DAQ items and 3 out of 4 mAPS domains. Regression models showed having a previous 3-month elective psychiatry inpatient posting was a predictor of less improvement in mAPS scores. CONCLUSIONS: Our experience-based, longitudinal psychiatry training program significantly improved Family Medicine residents' attitudes toward depression and psychiatry. Experiential and situated learning in communities of practice, as well as educational continuity with longitudinal supervision, coaching, and modeling may have contributed to this improvement.


Assuntos
Atitude do Pessoal de Saúde , Depressão/psicologia , Medicina de Família e Comunidade/educação , Internato e Residência , Psiquiatria/educação , Adulto , Educação de Pós-Graduação em Medicina , Feminino , Humanos , Masculino , Estudos Prospectivos , Singapura , Inquéritos e Questionários
2.
Europace ; 18(12): 1837-1841, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26847073

RESUMO

AIMS: Bradyarrhythmia following heart transplantation is common-∼7.5-24% of patients require permanent pacemaker (PPM) implantation. While overall mortality is similar to their non-paced counterparts, the effects of chronic right ventricular pacing (CRVP) in heart transplant patients have not been studied. We aim to examine the effects of CRVP on heart failure and mortality in heart transplant patients. METHODS AND RESULTS: Records of heart transplant recipients requiring PPM at St Vincent's Hospital, Sydney, Australia between January 1990 and January 2015 were examined. Patient's without a right ventricular (RV) pacing lead or a follow-up time of <1 year were excluded. Patients with pre-existing abnormal left ventricular function (<50%) were analysed separately. Patients were grouped by pacing dependence (100% pacing dependent vs. non-pacing dependent). The primary endpoint was clinical or echocardiographic heart failure (<35%) in the first 5 years post-PPM. Thirty-three of 709 heart transplant recipients were studied. Two patients had complete RV pacing dependence, and the remaining 31 patients had varying degrees of pacing requirement, with an underlying ventricular escape rhythm. The primary endpoint occurred significantly more in the pacing-dependent group; 2 (100%) compared with 2 (6%) of the non pacing dependent group (P < 0.0001 by log-rank analysis, HR = 24.58). Non-pacing-dependent patients had reversible causes for heart failure, unrelated to pacing. In comparison, there was no other cause of heart failure in the pacing-dependent group. CONCLUSIONS: Permanent atrioventricular block is rare in the heart transplant population. We have demonstrated CRVP as a potential cause of accelerated graft failure in pacing-dependent heart transplant patients.


Assuntos
Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Insuficiência Cardíaca/mortalidade , Transplante de Coração , Marca-Passo Artificial/efeitos adversos , Disfunção Primária do Enxerto/fisiopatologia , Adulto , Austrália , Bradicardia/etiologia , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia
3.
Pacing Clin Electrophysiol ; 38(8): 925-33, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25940215

RESUMO

BACKGROUND: Both implantable cardioverter defibrillators (ICDs) and left ventricular assist devices (LVADs) have a positive impact on survival in the heart failure population. We sought to determine whether these positive effects on survival are additive or whether LVAD therapy supersedes ICD therapy. METHOD: We analyzed survival data of patients implanted with nonpulsatile LVADs between October 2004 and March 2013. Survival in patients with ICDs (n = 64) was compared to those without ICDs (n = 36). Patients exited the study at the time of heart transplantation or death. RESULTS: A total of 100 patients underwent LVAD implantation during this time. Patients had a mean follow-up time of 364 ± 295 days. Death occurred in 15 (38%) patients in the no ICD group versus 18 (30%) in the ICD group. Univariate analysis demonstrated a marginal early survival benefit at up to 1 year post-LVAD implant in the ICD cohort; however, at time points greater than 1 year there was no statistically significant benefit in ICD therapy in LVAD patients (P = 0.56). Multivariate analysis did not show any significant predictor of survival. There were no patients who died of sudden cardiac death. There was no significant difference in the time to heart transplantation (443 days ± 251 no ICD vs 372 days ± 277 ICD, P = 0.37). CONCLUSION: The benefit of ICD therapy in the setting of continuous flow LVAD therapy is uncertain. Although prolonged ventricular arrhythmias (VAs) may potentially impact on patient survival, LVAD therapy is beneficial in prevention of sudden cardiac death due to VAs.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida
4.
Med J Aust ; 198(1): 27-8, 2013 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-23330766

RESUMO

Atrial fibrillation (AF) is estimated to affect 1%-2% of the population. It is increasing in prevalence and is associated with excess mortality, considerable morbidity and hospitalisations. AF is responsible for a significant and growing societal financial burden. Catheter ablation is an increasingly used therapeutic strategy for the management of AF; however, some confusion exists among those caring for patients with this condition about the role and optimal use of ablative treatments for AF. Our aim in this consensus statement is to provide recommendations on the use of primary catheter ablation for AF in Australia, on the basis of current evidence. Our consensus is that the primary indication for catheter ablation of AF is the presence of symptomatic AF that is refractory or intolerant to at least one Class 1 or Class 3 antiarrhythmic medication. In selecting patients for catheter ablation of AF, consideration should be given to the patient's age, duration of AF, left atrial size and the presence of significant structural heart disease. Best results are obtained in younger patients with paroxysmal AF, no structural heart disease and smaller atria. Ablation techniques for patients with persistent AF are still undergoing evaluation. Discontinuation of warfarin or equivalent therapies is not considered a sole indication for this procedure. After AF ablation, anticoagulation therapy is generally recommended for all patients for at least 1-3 months. Discontinuation of warfarin or equivalent therapies after ablation is generally not recommended in patients who have a CHADS 2 score (congestive heart failure, hypertension, age ≥ 75 years, diabetes, 1 point each; prior stroke or transient ischaemic attack, 2 points) of ≥ 2.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Antiarrítmicos , Fibrilação Atrial/tratamento farmacológico , Austrália , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Humanos , Prevenção Secundária , Sociedades Médicas , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
5.
Psychodyn Psychiatry ; 51(3): 350-373, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37712666

RESUMO

Introduction: Inpatients with self-harm behavior utilize a high proportion of health care resources, and determining their suicide risk may be challenging. This study examines how maladaptive personality traits in people who self-harm are associated with suicide intent severity. Methods: This was a 5-month cross-sectional study. The International Personality Disorders Examination (IPDE) ICD-10 questionnaire, Beck's Suicide Intent Scale (SIS), and the Depression Anxiety Stress Scale (DASS) 21 were administered. Sociodemographic and clinical data were recorded with STATA version 10.1 for statistical analyses. Results: Thirty-seven out of 40 (92.50%) inpatients participated in this study. About two-thirds (n = 24, 64.86%) were first-time self-harmers, with self-poisoning (n = 33, 89.19%) being the most common method. About two-thirds (n = 24, 64.86%) had low to moderate suicide intent. The most common diagnosis was adjustment disorder (n = 21, 56.76%). Around one-third had at least severe ratings for depressive, anxiety, and stress symptoms. All screened positive for at least one class of maladaptive personality traits, with the majority (n = 33, 89.19%) having more than one class of maladaptive personality traits. The three most prevalent classes of maladaptive personality traits were anankastic (n = 28, 75.68%), schizoid (n = 25, 67.57%), and paranoid (n = 23, 62.16%). Only dissocial traits were positively correlated with suicide intent severity (regression coefficient = 1.37, p = .017) following adjustment for the most important confounder, DASS 21. Discussion: Maladaptive personality traits were common in inpatients with self-harm behavior, with dissocial traits being positively correlated with suicide intent severity. This finding may inform suicide prevention strategies for patients who self-harm.


Assuntos
Pacientes Internados , Comportamento Autodestrutivo , Humanos , Estudos Transversais , Tentativa de Suicídio , Personalidade
6.
Psychodyn Psychiatry ; 50(3): 453-460, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36047792

RESUMO

The authors provide an overview of the history of psychiatric services and training in Singapore, and the more recent introduction of psychodynamic psychotherapy training for psychiatric residents. They describe the current state of psychodynamic psychiatry services in the public healthcare system, including efforts at fostering psychodynamic thinking in nonpsychiatric community partners via community mental health integrated care programs and activities such as Balint Groups. They discuss current challenges in psychodynamic practice, such as the impact of language and culture on the Singaporean individual's receptiveness to psychodynamic psychotherapy, as well as systemic challenges in funding and expanding psychodynamic services. They highlight future directions, including challenges and opportunities for the local psychodynamic community in Singapore.


Assuntos
Internato e Residência , Psiquiatria , Psicoterapia Psicodinâmica , Humanos , Psiquiatria/educação , Psicoterapia/educação , Psicoterapia Psicodinâmica/educação , Singapura
7.
Pacing Clin Electrophysiol ; 34(1): 72-5, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20946303

RESUMO

INTRODUCTION: The incidence, mechanisms, clinical associations, and outcomes in patients with late-onset (>3 months) atrioventricular (AV) block following heart transplantation are not well known. This study will characterize late-onset AV block following cardiac transplantation. METHODS: We retrospectively reviewed our databases to identify patients who required pacemakers for late-onset AV block postheart and heart-lung transplantation from January 1990 to December 2007. Orthotopic heart and heart-lung transplantation were separately analyzed. RESULTS: This study included 588 adults who received cardiac transplants over a 17-year period at our center (519 orthotopic, 64 heart-lung transplants, and five heterotopic heart transplants). Of the 519 patients with orthotopic heart transplant, 39 required pacing (7.5%), 17 (3.3%) within 3 months posttransplant, 11 (2.1%) for late-onset sinus node dysfunction (SND), 11 (2.1%) for late-onset AV block. Also, five patients (7.8%) out of 64 heart-lung transplants required pacemakers, two (3.1%) for late-onset SND, three (4.7%) for late-onset AV block. None of the five patients who underwent heterotopic transplant required cardiac pacing prior to or posttransplant. CONCLUSIONS: Late-onset AV block occurs in 2.4% of patients with orthotopic heart transplant or heart-lung transplant. AV block is predominantly intermittent and, often, does not progress to permanent AV block. There are no predictable factors for its onset.


Assuntos
Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/prevenção & controle , Estimulação Cardíaca Artificial/estatística & dados numéricos , Transplante de Coração/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Austrália/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 32(7): 879-87, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19572863

RESUMO

BACKGROUND: Nonpulsatile left ventricular assist devices (LVADs) are increasingly used for treatment of refractory heart failure. A majority of such patients have implanted cardiac devices, namely implantable cardioverter-defibrillators (ICDs) or cardiac resynchronization therapy-pacemaker (CRT-P) or cardiac resynchronization therapy-defibrillator (CRT-D) devices. However, potential interactions between LVADs and cardiac devices in this category of patients remain unknown. METHODS: We reviewed case records and device logs of 15 patients with ICDs or CRT-P or CRT-D devices who subsequently had implantation of a VentrAssist LVAD (Ventracor Ltd., Chatswood, Australia) as destination therapy or bridge to heart transplantation. Pacemaker and ICD lead parameters before and after LVAD implant were compared. In addition, ventricular tachyarrhythmia event logs and potential electromagnetic interference reports were evaluated. RESULTS: Right ventricular (RV) sensing decreased in the first 6 months post-LVAD. Mean R-wave amplitude preimplant was 10.9 +/- 5.25 mV compared with 7.2 +/- 3.4 mV during follow-up (P = 0.02). RV impedance also decreased from 642 +/- 240 ohms at baseline to 580 +/- 212 ohms at follow-up (P = 0.007). There was a significant increase in RV stimulation threshold following implantation of the LVAD from 0.8 +/- 0.6 V at baseline to 1.4 +/- 1.0 V in the first 6 months postimplant (P = 0.01). A marked increase in ventricular tachyarrhythmia burden was observed in three patients. One patient displayed electromagnetic interference between the LVAD and defibrillator, resulting in inappropriate defibrillation therapy. CONCLUSIONS: LVADs have a definite impact on cardiac devices in respect with alteration of lead parameters, ventricular tachyarrhythmias, and electromagnetic interference.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Adolescente , Adulto , Idoso , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
11.
Ann Acad Med Singap ; 45(4): 138-47, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27292004

RESUMO

INTRODUCTION: Many alcohol-related problems often go undetected and untreated. In Singapore, no epidemiological studies have been done in general hospitals on alcohol use disorders (AUD), i.e. alcohol dependence and abuse (DSM-IV-TR). Such findings are useful in planning AUD liaison services. In this study, we aim to estimate the prevalence of AUD among non-psychiatric inpatients and to determine the rates of identification and intervention rendered by medical staff. MATERIALS AND METHODS: Non-psychiatric medical and surgical wards inpatients aged 21 years and above were recruited over a 3-month period. The Alcohol Use Disorders Identification Test (AUDIT) was used to screen for AUD and the MINI International Neuropsychiatric Interview (MINI English Version 5.0.0) was administered to diagnose AUD if the AUDIT score was 8 or above. Case notes were independently reviewed for AUD identification and if interventions were offered during admissions. RESULTS: A total of 5599 inpatients were screened, of which 673 (12%) completed the screening using the AUDIT, and of these, 154 (2.8% of total sample) were positive for AUDIT. In this group, 107 were diagnosed with AUD. The estimated prevalence was 1.9% (approximately 400 cases per year per hospital). The medical staff identified only 25 (23.4%) cases of AUD, out of which, majority of them (76%) were rendered interventions. CONCLUSION: The rate of AUD identification by medical staff was low. Of those identified, majority were given interventions. Thus, the training of health care staff to identify AUD together with the implementation of brief interventions should be considered.


Assuntos
Alcoolismo/epidemiologia , Hospitalização , Hospitais Gerais , Programas de Rastreamento/estatística & dados numéricos , Adulto , Idoso , Alcoolismo/diagnóstico , Alcoolismo/terapia , Feminino , Humanos , Masculino , Serviços de Saúde Mental , Pessoa de Meia-Idade , Prevalência , Encaminhamento e Consulta , Singapura/epidemiologia , Adulto Jovem
13.
JACC Heart Fail ; 2(4): 323-30, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25023812

RESUMO

OBJECTIVES: The aim of this study was to determine the contribution of pre-load and heart rate to pump flow in patients implanted with continuous-flow left ventricular assist devices (cfLVADs). BACKGROUND: Although it is known that cfLVAD pump flow increases with exercise, it is unclear if this increment is driven by increased heart rate, augmented intrinsic ventricular contraction, or enhanced venous return. METHODS: Two studies were performed in patients implanted with the HeartWare HVAD. In 11 patients, paced heart rate was increased to approximately 40 beats/min above baseline and then down to approximately 30 beats/min below baseline pacing rate (in pacemaker-dependent patients). Ten patients underwent tilt-table testing at 30°, 60°, and 80° passive head-up tilt for 3 min and then for a further 3 min after ankle flexion exercise. This regimen was repeated at 20° passive head-down tilt. Pump parameters, noninvasive hemodynamics, and 2-dimensional echocardiographic measures were recorded. RESULTS: Heart rate alteration by pacing did not affect LVAD flows or LV dimensions. LVAD pump flow decreased from baseline 4.9 ± 0.6 l/min to approximately 4.5 ± 0.5 l/min at each level of head-up tilt (p < 0.0001 analysis of variance). With active ankle flexion, LVAD flow returned to baseline. There was no significant change in flow with a 20° head-down tilt with or without ankle flexion exercise. There were no suction events. CONCLUSIONS: Centrifugal cfLVAD flows are not significantly affected by changes in heart rate, but they change significantly with body position and passive filling. Previously demonstrated exercise-induced changes in pump flows may be related to altered loading conditions, rather than changes in heart rate.


Assuntos
Exercício Físico/fisiologia , Frequência Cardíaca/fisiologia , Coração Auxiliar , Postura/fisiologia , Valva Aórtica/fisiologia , Pressão Arterial/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Estimulação Cardíaca Artificial/métodos , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Feminino , Decúbito Inclinado com Rebaixamento da Cabeça/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Teste da Mesa Inclinada , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa