Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
J Cardiovasc Magn Reson ; 22(1): 13, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-32036784

RESUMO

BACKGROUND: Using cardiovascular magnetic resonance imaging (CMR), it is possible to detect diffuse fibrosis of the left ventricle (LV) in patients with atrial fibrillation (AF), which may be independently associated with recurrence of AF after ablation. By conducting CMR, clinical, electrophysiology and biomarker assessment we planned to investigate LV myocardial fibrosis in patients undergoing AF ablation. METHODS: LV fibrosis was assessed by T1 mapping in 31 patients undergoing percutaneous ablation for AF. Galectin-3, coronary sinus type I collagen C terminal telopeptide (ICTP), and type III procollagen N terminal peptide were measured with ELISA. Comparison was made between groups above and below the median for LV extracellular volume fraction (ECV), followed by regression analysis. RESULTS: On linear regression analysis LV ECV had significant associations with invasive left atrial pressure (Beta 0.49, P = 0.008) and coronary sinus ICTP (Beta 0.75, P < 0.001), which remained significant on multivariable regression. CONCLUSION: LV fibrosis in patients with AF is associated with left atrial pressure and invasively measured levels of ICTP turnover biomarker.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Pressão Atrial , Biomarcadores/sangue , Proteínas Sanguíneas , Ablação por Cateter , Colágeno Tipo I/sangue , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose , Galectina 3/sangue , Galectinas , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Valor Preditivo dos Testes , Pró-Colágeno/sangue
2.
J Cardiovasc Electrophysiol ; 29(12): 1624-1634, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30168232

RESUMO

INTRODUCTION: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system are implicated in arrhythmogenesis. GP localization by stimulation of the epicardial fat pads to produce atrioventricular dissociating (AVD) effects is well described. We determined the anatomical distribution of the left atrial GPs that influence atrioventricular (AV) dissociation. METHODS AND RESULTS: High frequency stimulation was delivered through a Smart-Touch catheter in the left atrium of patients undergoing atrial fibrillation (AF) ablation. Three dimensional locations of points tested throughout the entire chamber were recorded on the CARTO™ system. Impact on the AV conduction was categorized as ventricular asystole, bradycardia, or no effect. CARTO maps were exported, registered, and transformed onto a reference left atrial geometry using a custom software, enabling data from multiple patients to be overlaid. In 28 patients, 2108 locations were tested and 283 sites (13%) demonstrated (AVD-GP) effects. There were 10 AVD-GPs (interquartile range, 11.5) per patient. Eighty percent (226) produced asystole and 20% (57) showed bradycardia. The distribution of the two groups was very similar. Highest probability of AVD-GPs (>20%) was identified in: inferoseptal portion (41%) and right inferior pulmonary vein base (30%) of the posterior wall, right superior pulmonary vein antrum (31%). CONCLUSION: It is feasible to map the entire left atrium for AVD-GPs before AF ablation. Aggregated data from multiple patients, producing a distribution probability atlas of AVD-GPs, identified three regions with a higher likelihood for finding AVD-GPs and these matched the histological descriptions. This approach could be used to better characterize the autonomic network.


Assuntos
Atlas como Assunto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Gânglios Autônomos/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Idoso , Ablação por Cateter/métodos , Feminino , Gânglios Autônomos/anatomia & histologia , Átrios do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade
3.
Catheter Cardiovasc Interv ; 92(2): 269-273, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29044976

RESUMO

BACKGROUND: The assessment of myocardial viability is crucial before percutaneous coronary intervention (PCI) is carried out to ensure that the patient will gain benefit. Trans-coronary pacing (TCP) has previously been used to pace myocardium but may also provide information on myocardial viability. METHODS: Patients with a single, significant coronary stenosis requiring PCI were recruited. They underwent a cardiac MRI to assess myocardial viability. Prior to PCI, a coronary guidewire was used to measure pacing threshold, impedance, and R-wave amplitude in different myocardial segments to determine any association between the electrical parameters and myocardial viability. RESULTS: Eight patients were recruited and six patients underwent intervention. Pacing sensitivity did not demonstrate statistically significant differences between normal and scarred myocardium. Impedance demonstrated a mean of 304.8 ± 74.0 Ω in normal myocardium (NM), 244.1 ± 66.6 Ω in <50% myocardial scar (MS), and 222.3 ± 33.8 Ω in ≥50% MS. Pacing threshold demonstrated a mean of 1.960 ± 1.226 V in NM, 5.009 ± 2.773 V in <50% MS, and 3.950 ± 0.883 V in ≥50% MS. For both impedance and threshold, there was a significant difference among the groups (P = 0.12 and P = 0.002, respectively), and post hoc Tukey's pairwise comparison demonstrated significant differences between NM and scarred myocardium. No significant differences were found between <50% MS and ≥50% MS. CONCLUSIONS: Impedance and pacing threshold, measured during TCP, can be used to differentiate between normal myocardium and scarred myocardium. Further research is needed to determine whether TCP can discriminate between viable and nonviable myocardium.


Assuntos
Estimulação Cardíaca Artificial , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Miocárdio/patologia , Adulto , Idoso , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/patologia , Estenose Coronária/cirurgia , Impedância Elétrica , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Sobrevivência de Tecidos
4.
Europace ; 20(FI1): f13-f19, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016773

RESUMO

Aims: The identification of arrhythmogenic right ventricular dysplasia (ARVD) from 12-channel standard electrocardiogram (ECG) is challenging. High density ECG data may identify lead locations and criteria with a higher sensitivity. Methods and results: Eighty-channel ECG recording from patients diagnosed with ARVD and controls were quantified by magnitude and integral measures of QRS and T waves and by a measure (the average silhouette width) of differences in the shapes of the normalized ECG cycles. The channels with the best separability between ARVD patients and controls were near the right ventricular wall, at the third intercostal space. These channels showed pronounced differences in P waves compared to controls as well as the expected differences in QRS and T waves. Conclusion: Multichannel recordings, as in body surface mapping, add little to the reliability of diagnosing ARVD from ECGs. However, repositioning ECG electrodes to a high anterior position can improve the identification of ECG variations in ARVD. Additionally, increased P wave amplitude appears to be associated with ARVD.


Assuntos
Potenciais de Ação , Displasia Arritmogênica Ventricular Direita/diagnóstico , Eletrocardiografia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Estudos de Casos e Controles , Eletrocardiografia/instrumentação , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
5.
Pacing Clin Electrophysiol ; 41(12): 1600-1605, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30267542

RESUMO

BACKGROUND: South Asians have a lower prevalence of atrial fibrillation (AF) compared with Caucasians despite higher rates of conventional risk factors and a higher incidence of stroke. It is not clear whether South Asians truly experience less AF or whether this is due to underdetection of the arrhythmia. Therefore, we aimed to determine whether South Asian patients with pacemakers have a lower incidence of device-detected subclinical episodes of AF compared with Caucasian controls. METHODS: We performed a retrospective cohort study of South Asian and Caucasian patients who underwent pacemaker implantation between 2006 and 2016. Subclinical AF episodes, detected during subsequent device clinic follow-up visits, were identified and the occurrence of clinical AF, cerebrovascular events, and all-cause mortality was recorded. RESULTS: A total of 5 648 patients underwent pacemaker implantation at the Yorkshire Heart Centre, UK, during the study period. Of these, 169 were South Asian and 72 met the eligibility criteria. The cumulative incidence of subclinical AF was significantly lower in South Asians compared with Caucasians (logrank P  =  0.002) with an annual event rate of 6.9% versus 13.9%, and South Asian ethnicity was an independent predictor of a lower incidence of subclinical AF (odds ratio =  0.43; 95% confidence interval  =  1.01-5.38). CONCLUSIONS: South Asians with an implanted pacemaker have a lower rate of subclinical AF compared with Caucasians.


Assuntos
Fibrilação Atrial/etnologia , Fibrilação Atrial/epidemiologia , Idoso , Sudeste Asiático/etnologia , Fibrilação Atrial/terapia , Inglaterra , Feminino , Humanos , Incidência , Masculino , Marca-Passo Artificial , Estudos Retrospectivos
6.
Europace ; 19(12): 1944-1950, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339804

RESUMO

AIMS: Measurement of circulating biomarkers of fibrosis may have a role in selecting patients and treatment strategy for catheter ablation. Pro-collagen type III N-terminal pro-peptide (PIIINP), C-telopeptide of type I collagen (ICTP), fibroblast growth factor 23 (FGF-23), and galectin 3 (gal-3) have all been suggested as possible biomarkers for this indication, but studies assessing whether peripheral levels reflect intra-cardiac levels are scarce. METHODS AND RESULTS: We studied 93 patients undergoing ablation for paroxysmal atrial fibrillation (AF) (n = 63) or non-paroxysmal AF (n = 30). Femoral venous, left and right atrial, and coronary sinus blood were analysed using ELISA to determine biomarker levels. Levels were compared with control patients (n = 36) and baseline characteristics, including left atrial voltage mapping data. C-telopeptide of type I collagen levels were higher in AF than in non-AF patients (P = 0.007). Peripheral ICTP levels were higher than all intra-cardiac levels (P < 0.001). Peripheral gal-3 levels were higher than left atrial levels (P = 0.001). Peripheral levels of FGF-23 and PIIINP were not significantly different from intra-cardiac levels. CS levels of ICTP were higher than right and left atrial levels (P < 0.001). gal-3 was higher in women vs. men (P ≤ 0.001) and with higher body mass index (P ≤ 0.001). ICTP levels increased with reducing ejection fraction (P ≤ 0.012). CONCLUSIONS: Atrial fibrillation patients have higher levels of circulating ICTP than matched non-AF controls. In AF ablation patients, intra-cardiac sampling of FGF-23 or PIIINP gives no further information over peripheral sampling. For gal-3 and ICTP, intra-cardiac sampling may be necessary to assess their association with intra-cardiac processes. None of the biomarkers is related to fibrosis assessed by left atrial voltage.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Colágeno Tipo I/sangue , Fatores de Crescimento de Fibroblastos/sangue , Galectina 3/sangue , Átrios do Coração/metabolismo , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Pró-Colágeno/sangue , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Proteínas Sanguíneas , Estudos de Casos e Controles , Tomada de Decisão Clínica , Técnicas Eletrofisiológicas Cardíacas , Ensaio de Imunoadsorção Enzimática , Feminino , Fator de Crescimento de Fibroblastos 23 , Fibrose , Galectinas , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Resultado do Tratamento , Função Ventricular Esquerda
9.
J Antimicrob Chemother ; 70(2): 325-59, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25355810

RESUMO

Infections related to implantable cardiac electronic devices (ICEDs), including pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices, are increasing in incidence in the USA and are likely to increase in the UK, because more devices are being implanted. These devices have both intravascular and extravascular components and infection can involve the generator, device leads and native cardiac structures or various combinations. ICED infections can be life-threatening, particularly when associated with endocardial infection, and all-cause mortality of up to 35% has been reported. Like infective endocarditis, ICED infections can be difficult to diagnose and manage. This guideline aims to (i) improve the quality of care provided to patients with ICEDs, (ii) provide an educational resource for all relevant healthcare professionals, (iii) encourage a multidisciplinary approach to ICED infection management, (iv) promote a standardized approach to the diagnosis, management, surveillance and prevention of ICED infection through pragmatic evidence-rated recommendations, and (v) advise on future research projects/audit. The guideline is intended to assist in the clinical care of patients with suspected or confirmed ICED infection in the UK, to inform local infection prevention and treatment policies and guidelines and to be used in the development of educational and training material by the relevant professional societies. The questions covered by the guideline are presented at the beginning of each section.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/prevenção & controle , Gerenciamento Clínico , Humanos
10.
J Cardiovasc Electrophysiol ; 26(12): 1307-14, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26727045

RESUMO

INTRODUCTION: Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared these 3 strategies in a randomized controlled trial. METHODS AND RESULTS: Patients undergoing first time paroxysmal AF ablation were randomized to RFCA, CRYO, or COMBINED. Patients were followed up at 3, 6, and 12 months with 7 days of ambulatory ECG monitoring. Success was defined as freedom from arrhythmia without antiarrhythmic drugs after a single procedure. A total of 237 patients were randomized. Success at 1 year was achieved in 47% in the RFCA group, 67% in the CRYO group, and 76% in the COMBINED group (P < 0.001 for RFCA vs. CRYO, P<0.001 for RFCA vs. COMBINED, and P = 0.220 for CRYO vs. COMBINED). Procedure time was 211 (IQR 174-256) minutes for RFCA compared to 167 (136-202) minutes for CRYO and 278 (243-327) minutes for COMBINED (P < 0.001 for RFCA vs. COMBINED, RFCA vs. CRYO, and CRYO vs. COMBINED groups). CONCLUSIONS: Pulmonary vein isolation for paroxysmal AF is faster with CRYO and results in a higher single procedure success rate than conventional point by point RFCA. The COMBINED approach was not superior to CRYO alone.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares , Idoso , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Terapia Combinada , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-38478165

RESUMO

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

12.
BJPsych Bull ; 47(1): 11-16, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34823623

RESUMO

AIMS AND METHOD: People diagnosed with dementia are often started on acetylcholinesterase inhibitors (AChEIs). As AChEIs can be associated with cardiac side-effects, an electrocardiogram (ECG) is sometimes requested before treatment. Previous work has suggested there is little consensus as to when or how ECGs should be obtained. This can create inconsistent practice, with patient safety, economic and practical repercussions. We surveyed 305 UK memory clinic practitioners about prescribing practice. RESULTS: More than 84% of respondents completed a pulse and cardiac history before prescribing AChEIs. Opinion was divided as to who should fund and conduct ECGs. It was believed that obtaining an ECG causes patients inconvenience and delays treatment. Despite regularly interpreting ECGs, 76% of respondents did not update this clinical skill regularly. CLINICAL IMPLICATIONS: The variation in practice observed has service-level and patient implications and raises potential patient safety concerns. Implementing national guidelines or seeking novel ways of conducting cardiac monitoring could help standardise practice.

13.
J Clin Med ; 12(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38002591

RESUMO

Intracoronary guidewires used in percutaneous coronary intervention can also be configured to provide temporary ventricular pacing. Trans coronary electrophysiological parameters recorded by employing coronary guidewires may have a potential role in assessing myocardial viability and could provide a means to make an immediate on-table decision about revascularisation. To date, some small studies have demonstrated the safety of this technique in temporary cardiac pacing, but further research is required to refine this approach and establish its clinical utility in myocardial viability assessment. In this review we discuss the potential role of trans coronary electrophysiology in the assessment of myocardial viability.

14.
J Cardiovasc Transl Res ; 16(3): 715-721, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36414925

RESUMO

The aim of this study is to evaluate the feasibility of creating fast three-dimensional maps of coronary arteries and to develop a bipolar coronary guidewire in vitro and determine whether it can be localised accurately within the model.A total of five patients were recruited, and EnSite Precision was utilised to create 3D coronary anatomy. A water bath to accommodate a 3D-printed coronary model was developed to test the performance of the bipolar angioplasty wire.Successful guidewire localisation and 3D reconstruction of coronary anatomy were achieved in all the cases. No complications. The bipolar wire was able to collect point clouds, and localisation of the distal tip was excellent when tested in the water bath.Our study demonstrates the feasibility and safety of utilising EAMS to collect coronary anatomy. Real-time tracking with a bipolar catheter is accurate when tested in vitro.


Assuntos
Vasos Coronários , Coração , Humanos , Desenho de Equipamento , Vasos Coronários/diagnóstico por imagem , Eletrofisiologia , Água , Imageamento Tridimensional
15.
BJPsych Bull ; 47(6): 352-356, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36700251

RESUMO

To monitor for drug-related cardiac arrhythmias, psychiatrists regularly perform and interpret 12-lead (12L) and, increasingly often, six-lead (6L) electrocardiograms (ECGs). It is not known how training on this complex skill is updated or how well psychiatrists can interpret relevant arrhythmias on either device.We conducted an online survey and ECG interpretation test of cardiac rhythms relevant to psychiatrists.A total of 183 prescribers took part; 75% did not regularly update their ECG interpretation skills, and only 22% felt confident in interpreting ECGs. Most participants were able to recognise normal ECGs. For both 6L and 12L ECGs, the majority of participants were able to recognise abnormal ECGs, but fewer than 50% were able to correctly identify relevant arrhythmias (complete heart block and long QTc). A small number prescribed in the presence of potentially fatal arrhythmias. These findings suggest a need for mandatory ECG interpretation training to improve safe prescribing practice.

16.
PLoS One ; 18(2): e0281374, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36745641

RESUMO

INTRODUCTION: Percutaneous coronary intervention is performed routinely in the management of myocardial infarction with obstructive coronary disease, but intervention to arteries supplying nonviable myocardium may be harmful. It is important therefore to establish myocardial viability, and there is an unmet need in current clinical practice for real time viability assessment to aid in decision making. Transcoronary pacing to assess myocardial electrophysiological parameters may be a novel viability assessment technique which could be used in this regard. METHODS: Coronary intervention was carried out according to standard departmental procedure with standard equipment. An exchange length coronary guidewire was passed into both target and reference coronary vessels and an over-the-wire balloon or microcatheter was used to insulate the guidewire and allow electrophysiological parameters to be assessed. Readings were obtained from all major epicardial vessels and substantial branches. At each position, an intracoronary electrocardiogram was recorded, and R wave amplitude was measured. Transcoronary pacing was then performed to establish threshold and impedance for each myocardial segment. A viability cardiac MRI scan was performed for each patient. A standard segmental model was used to determine viability in each segment using an 'infarct score' based on degree of late gadolinium enhancement. Studies were reported blinded to the electrical parameters obtained from the coronary guidewire. The primary outcome was the relationship between pacing threshold and myocardial segment infarct score. Secondary outcomes included the relationship between segmental infarct score and R wave height, and between segmental infarct score and pacing impedance. Data were collected on the feasibility of studying the coronary segments as well as safety. RESULTS: Sixty-five patients presenting with stable coronary artery disease or acute coronary syndromes to Leeds General Infirmary between September 2019 and August 2021 were included in the study. Electrophysiological parameters from segments with an infarct score of zero were obtained, with wide variances seen, with no significant difference in impedance or threshold in any territory. There was a significant difference in sensitivity for segments in the right coronary artery territory for both elective and acute patients. This likely relates to reduced myocardial mass in these territories. No significant association between infarct score and sensitivity, impedance or threshold were seen. CONCLUSION: This study has established intracoronary electrophysiological parameters in both normal myocardium and areas of myocardial scar. No reliable association was seen between impedance, threshold or R wave amplitude and degree of myocardial viability, contrasting with prior findings from our group and others. More work is therefore required to fully understand the role of transcoronary pacing in this setting.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Meios de Contraste , Gadolínio , Miocárdio , Infarto do Miocárdio/terapia , Doença da Artéria Coronariana/terapia , Resultado do Tratamento
17.
Heart ; 109(5): 364-371, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36396438

RESUMO

OBJECTIVE: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL). METHODS: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (>30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy. RESULTS: Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of ≥2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000). CONCLUSION: Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF. TRIAL REGISTRATION NUMBER: NCT03401099.


Assuntos
Fibrilação Atrial , Flutter Atrial , COVID-19 , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Idoso , Feminino , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/epidemiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , COVID-19/complicações , SARS-CoV-2 , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Recidiva
18.
Eur Heart J Case Rep ; 6(5): ytac185, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35592745

RESUMO

Background: Haemothoraces are a reported but extremely rare complication of pacemaker implantation. Haemothoraces can be a consequence of lead perforation through the right ventricle (RV) and pericardium into the pleural space, direct lung or vascular injury during access. Case summary: A 72-year-old woman presented 24 h after a pacemaker implantation with chest pain and shortness of breath. Computed tomography of the chest confirmed perforation of the RV lead into the left pleural cavity with a large left sided haemothorax. Following percutaneous drainage of the left sided haemothorax, the patient became haemodynamically unstable necessitating emergent sternotomy. During surgery, the extra-cardiac portion of the pacing lead was cut, the RV repaired and a large haematoma evacuated from the left pleural space. Despite this, the patient remained hypotensive, and further exploration showed a bleeding intercostal artery that had been lacerated by the pacing lead. This was treated by electrocautery, and the patient's haemodynamic status improved. The RV lead remnant was removed transvenously via the subclavian vein, and the patient was left with a single chamber atrial pacemaker. Discussion: Prompt recognition of RV lead perforation and its associated sequalae, often utilising multi-modality imaging, is vital to enable transfer to a centre with cardiac surgical expertise. In this case, the perforating RV lead lacerated an intercostal artery, and this was only identified at the time of surgery. In order to minimize the risk of perforation, multiple fluoroscopic views should be used, and care should be taken during helix deployment.

20.
Europace ; 13(9): 1250-5, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21572091

RESUMO

INTRODUCTION: Pulmonary vein (PV) isolation for atrial fibrillation (AF) often requires repeat procedures due to PV reconnection. We hypothesized that wide area cicumferential ablation using radiofrequency energy (RFA) followed by ostial PV ablation with a cryoablation balloon would reduce the rate of AF recurrence compared with either approach alone. METHODS AND RESULTS: A retrospective study compared outcomes in the first 25 consecutive patients undergoing PV isolation for paroxysmal AF using the combined approach, to consecutive controls using either approach alone. Demographic and procedural data were collected from a prospective database. Kaplan-Meier curves were used to analyse AF free survival and curves were compared using the log-rank test. Twenty-five patients were included in each group. There were no major complications. Minor complications included two transient phrenic nerve palsies and a haematoma in both the combined groups and the cryoablation alone groups. In the RFA group the only complication was a grounding plate burn. Follow-up was 2.2 years in the RFA group, 1.0 years in the cryoablation group, and 1.4 years in the combined group. All recurrences but one occurred within one year. Freedom from AF was significantly greater in the combined group (80%) compared with the RFA alone group (52%) and the cryoablation alone group (56%, both P < 0.05). CONCLUSION: The combined approach was safe and increased single procedure efficacy of PV isolation for AF compared with either technique alone.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Crioterapia/efeitos adversos , Veias Pulmonares/cirurgia , Idoso , Terapia Combinada , Feminino , Hematoma/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Nervo Frênico/lesões , Estudos Prospectivos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa