Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Clin Oral Investig ; 28(1): 92, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217685

RESUMO

OBJECTIVE: This study aimed to identify the 100 top-cited articles on dentin adhesives utilizing comprehensive bibliometric and altmetric analyses. MATERIALS AND METHODS: The Institute of Scientific Information Web of Knowledge database was used to compile the top-cited articles published from 1945 through February 12, 2023. Citation counts were manually retrieved for each article from Scopus, Google Scholar, Dimensions, and Altmetric. The articles were analyzed in terms of their number of citations, year, journal name, author (name, institution, and country), and type and specific field of study. We used descriptive statistics to summarize the results. RESULTS: The analysis revealed that the top 100 cited articles originated from 18 English-language journals and collectively accumulated a remarkable 34526 citations. The article with the highest number of citations garnered 1288 references. Among authors, Van Meerbeek B. stood out with nine articles and 4650 citations, followed by Pashley D.H. with six articles and 2769 citations. Japan was the leading contributor by country, while the Catholic University of Leuven led in terms of institutions with 20 articles. CONCLUSION: According to this study, basic research and review articles garnered the most citations, respectively. The citation analysis revealed different trends for researchers, the first being that researchers have focused on basic fields such as the ultramorphology of dentin and adhesive interfaces, followed by bond strength to dentin. Two studies on clinical experiences suggested that studies with high-level evidence, such as systematic reviews, meta-analyses, or randomized controlled clinical trials, are required. CLINICAL RELEVANCE: It is identified that more studies with high-level evidence-based research are needed in the field of dental adhesives.


Assuntos
Altmetria , Bibliometria , Dentina , Japão
2.
Am J Dent ; 37(3): 115-120, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899989

RESUMO

PURPOSE: To evaluate the effect of two resin composites (with different viscosities) and the elevation amount on fracture strength and fracture behavior of molars with and without deep margin elevations (DME). METHODS: 70 extracted, caries-free human molars were selected. All teeth were prepared as MOD onlay cavities with a margin 2 mm below the cemento-enamel junction (CEJ) on the mesial and buccal sides and 2 mm above the CEJ on the distal side. The teeth were divided into two groups according to the type of resin composite used in margin elevation, elevated with flowable composite (Universal Flo) or condensable composite (G-Aenial Posterior). These two groups were further subdivided into subgroups in which the elevation was 2, 3, or 4 mm, and a control group in which the non-elevated indirect restoration was directly bonded to the subgingival margin, making a total of seven groups (n= 10). After elevations, the restorations were completed using a nanoceramic CAD-CAM block (Cerasmart A3 HT) and as adhesive cement, G-Cem Link Force. Static force was applied to the restored teeth using a universal testing machine at an angle of 15° until fracture occurred. Fracture strength values were recorded, and fracture types were examined under 6x magnification. One-way ANOVA was carried out to determine the effect of DME on the fracture strength. A two-way ANOVA was conducted to investigate main and interaction effects of the material type used in the elevation and the amount of elevation made on the fracture strength (P< 0.05). RESULTS: Using flowable or condensable composite as elevation material did not affect the fracture strength of CAD-CAM restorations. Flowable and condensable composites of 2, 3, or 4 mm did not significantly affect fracture strength values for either material. Specimen margins with and without elevation exhibited similar fracture strength values. The type of material used in the elevation and the amount did not affect the fracture strength of teeth. CLINICAL SIGNIFICANCE: The deep margin elevation technique for teeth with carious lesions extending subgingivally, may be useful in routine practice.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Restauração Dentária Permanente , Análise do Estresse Dentário , Humanos , Resinas Compostas/química , Restauração Dentária Permanente/métodos , Dente Molar , Falha de Restauração Dentária , Teste de Materiais , Fraturas dos Dentes , Técnicas In Vitro , Preparo da Cavidade Dentária/métodos , Materiais Dentários/química , Adaptação Marginal Dentária , Cimentos Dentários/química , Adesivos Dentinários
3.
Am J Dent ; 37(3): 136-140, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899993

RESUMO

PURPOSE: To investigate the effect of different chemical compositions of primers on the bond strength between nano-ceramic, polymer-infiltrated ceramic, and zirconia ceramic materials and dual-cure cement. METHODS: Fifty 2 mm-thick specimens were prepared from Vita Enamic, Cerasmart, and Katana Zirconia UTML. The specimens were embedded in acrylic blocks. To standardize the surfaces, 600 grit silicon carbide abrasives were applied underwater for 60 seconds. Then, each section underwent grit-blasting using Al2O3 with a particle size of 50 µm at 10 mm and a pressure of 2 bar for 10 seconds. Each prepared sample from the experimental groups received the appropriate primer (Z-PRIME Plus, G-Multi Primer, Alloy Primer, Clearfil Primer Plus) according to the manufacturers' instructions. Subsequently, the prepared CAD-CAM specimens underwent cementation using Duo-Link Universal Adhesive Resin Cement with a cylinder mold of 2.6 mm diameter and 3 mm height. The cement was light-cured for 20 seconds from both sides. The specimens obtained were stored in distilled water at 37°C for 24 hours. The shear bond strength test of the specimens was performed using a Bisco Shear Bond Tester device. The data were statistically analyzed using ANOVA and the Kruskal-Wallis test (P< 0.05). RESULTS: The highest bond strength was observed in Z-Prime Plus applied specimens, regardless of material differences (Cerasmart 11.60±4.61; Vita Enamic 12.93±3.86; Katana Zirconia 13.85±4.00). The lowest bond strength, showing differences according to materials (P< 0.05), was found for Clearfil Ceramic Primer Plus-Cerasmart (7.88±3.90), Alloy Primer-Vita Enamic (7.90±2.14), and G Multi Primer-Katana Zirconia UTML (4.98±3.67). CLINICAL SIGNIFICANCE: Failure of the restoration usually occurs at the weakest point in this three-element structure, thus correct primer selection according to material type is important. Additionally, for all CAD-CAM materials used in the study, Z-Prime Plus showed significantly greater adhesion strength than other systems so it may be more appropriate for use in clinics.


Assuntos
Cerâmica , Colagem Dentária , Cimentos de Resina , Resistência ao Cisalhamento , Cimentos de Resina/química , Cerâmica/química , Teste de Materiais , Zircônio/química , Análise do Estresse Dentário , Propriedades de Superfície , Desenho Assistido por Computador
4.
J Prosthet Dent ; 131(5): 935.e1-935.e8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38431509

RESUMO

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass-ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change. MATERIAL AND METHODS: One hundred and six 2-mm-thick specimens were prepared from IPS e.max CAD and Cerasmart, and a total of 53 intact human teeth were used. Five specimens from each group were used to measure the amount of live biomass in the biofilm. The remaining 48 specimens in each group were divided into 4 subgroups: kept in distilled water without the formation of dental biofilm (DW), kept in tea without the formation of dental biofilm (T), kept in distilled water after the formation of dental biofilm (DWB), and kept in tea after the formation of dental biofilm (TB) (n=12). After finishing and polishing the materials, initial color measurements were made using a spectrophotometer, and surface roughness measurements were made using noncontact profilometer. After creating a biofilm layer in DWB and TB, all specimens were kept in their solutions at 37 °C for 24 hours, and the color measurements were repeated. After the biofilm layer had been removed by brushing, a third color measurement was made. The data were statistically analyzed with one-way analysis of variance (ANOVA) and two-way ANOVA (α=.05). RESULTS: The lowest roughness value was observed in Cerasmart. Tooth-IPS e.max CAD gave similar results. The Cerasmart material had the most viable biomass, whereas the IPS e.max CAD material had the least. TB had the highest ΔE1 value for all materials and DW had the lowest (P<.05). The brushing procedure caused the materials to return to their initial colors or reduce the color change in most groups. CONCLUSIONS: The presence of biofilm on CAD-CAM materials immersed in distilled water caused an unacceptable degree of discoloration (ΔE>1.8), and immersion in tea led to greater color change. The adhesion of biofilm to restorative dental materials plays an important role in the coloring of these dental materials.


Assuntos
Biofilmes , Cerâmica , Cor , Desenho Assistido por Computador , Porcelana Dentária , Propriedades de Superfície , Cerâmica/química , Humanos , Teste de Materiais , Técnicas In Vitro , Materiais Dentários/química , Escovação Dentária , Resinas Sintéticas
5.
Clin Oral Investig ; 26(3): 2719-2732, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35083586

RESUMO

OBJECTIVES: The purpose of this study was to identify the prevalence and predisposing and etiologic factors of dentin hypersensitivity (DH), as well as the demographic characteristics of patients. MATERIALS AND METHODS: The 1210 patients were examined. The research was based on a two-step investigation: questionnaire and clinical examination. DH was evaluated by the response of the patient to tactile and air-blast stimuli. Loss of attachment and gingival recession of sensitive teeth was measured on the buccal and lingual surfaces. Also, the tooth wear of sensitive teeth was graded on the buccal and lingual surfaces. Comparisons of nonnormally distributed continuous variables were performed using the Mann-Whitney U test and Kruskal-Wallis one-way analysis of variance (ANOVA) and Dunn's post hoc test. Comparisons of categorical variables were performed using Pearson's chi-square, Fisher's exact chi-square, Yates's chi-square, and the Monte Carlo chi-square test. RESULTS: One hundred twenty-four patients reported DH, showing a prevalence for self-reported DH of 10.2%. Eight hundred forty teeth were diagnosed as having DH, giving a clinical diagnosis rate of DH of 29.4%. Females (76.8%), the 31-40 years age group (26%), housewives (36.8%), and high school education level (38%) had the highest prevalence of DH as demographic properties. A cold stimulus was the most common stimuli trigger for hypersensitivity (97.1%). Occasional pain (55.5%) showed the highest prevalence in terms of frequency of DH. A higher rate of DH was found with the use of medium brushes (47.4%) and brushing twice per day (59.4%) for 1-2 min (56.2%) with the circular method (33.8%) as oral hygiene habits. The buccal surface of the lower right central incisors (5.7%) had the highest prevalence. The most affected teeth by DH were incisors (38.4%). The buccal surfaces (86.3%) of teeth showed a higher high prevalence of DH compared with the lingual surface (52.7%), similar to gingival recession (40.9% vs. 15.7%) and loss of attachment (68.3% vs. 42.6%). CONCLUSIONS: Clinically diagnosed DH was more common than self-reported DH. Some factors related to patients such as sex (female), the 31-40 years age group, housewives, high school students, using medium brushes, brushing twice per day, and the circular brushing method were more likely to have a risk for DH. Also, buccal surfaces of teeth, gingival recession, and loss of attachment on the buccal surface of teeth should be considered as predisposing factors for DH. CLINICAL RELEVANCE: To control and prevent DH, clinicians should consider patients' demographics, predisposing factors, and etiologic factors.


Assuntos
Sensibilidade da Dentina , Retração Gengival , Atrito Dentário , Sensibilidade da Dentina/diagnóstico , Sensibilidade da Dentina/epidemiologia , Sensibilidade da Dentina/etiologia , Feminino , Retração Gengival/epidemiologia , Humanos , Prevalência , Escovação Dentária/efeitos adversos
6.
J Esthet Restor Dent ; 34(7): 1039-1050, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35604035

RESUMO

OBJECTIVE: To evaluate the clinical performance of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendations, doubling the adhesive application time and layer in Class I cavities with a composite resin. MATERIALS AND METHODS: A total of 39 patients aged between 14 and 43 (mean age: 19.1) years were enrolled in the study. Each patient received three restorations. In these three restorations, a 1-step self-etch adhesive was applied according to the manufacturer's recommendations (control group), by doubling the adhesive application time, and with double layers. The restorations were evaluated according to modified USPHS criteria at baseline, and 1, 2, 3, and 4-year recalls. RESULTS: After 4 years, the success rate was 100% for restorations with the adhesive applied according to the manufacturers' recommendations, 96.9% for restorations applied by doubling the adhesive application time, and 93.8% for restorations applied with double adhesive layers. There was no significant difference between the three application methods among all the evaluation periods regarding the evaluation criteria. CONCLUSIONS: The 4-year success rates of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendation, by doubling the adhesive application time, and with double layers were excellent. CLINICAL SIGNIFICANCE: It is not recommended to double the adhesive application time nor apply a double layer of a 1-step self-etch adhesive because it does not improve the clinical performance of Class I composite restorations.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Adolescente , Adulto , Resinas Compostas , Cimentos Dentários , Restauração Dentária Permanente/métodos , Adesivos Dentinários , Humanos , Cimentos de Resina , Adulto Jovem
7.
J Prosthodont ; 30(6): 481-489, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33128411

RESUMO

PURPOSE: To investigate the effects of different polishing procedures on surface properties of CAD/CAM resin blocks. MATERIALS AND METHODS: In this study, three different CAD/CAM restorative materials (Cerasmart, Lava Ultimate and Shofu Block HC) were used. CAD/CAM blocks were cut in 3-mm-thick slabs and divided into 5 groups. Group-1: Glaze; Group-2: Two-step Diamond Polisher; Group-3: One-step Diamond Polisher; Group-4: Three-step Diamond Polisher; Group-5: Polishing Discs+Diamond Paste. After polishing, top surfaces of the samples were prepared to screen by noncontact laser profilometer (Nanovea) for measurements. Data were analyzed using two-way analysis of variance (ANOVA). RESULTS: The arithmetical mean deviation of the profile was defined as Ra. The extension of Ra (a line's arithmetical mean height) to a surface was defined as Sa. Compared to the arithmetical mean of the surface, Sa expresses the difference in terms of each point's height as an absolute value. Sa was commonly used to assess surface roughness. The highest surface roughness (Ra) values in this study were 0.313 ± 0.05 for Cerasmart, 0.433 ± 0.10 for Lava Ultimate and 0.320 ± 0.05 for Shofu Block HC. The specimens in Group-4 displayed higher Ra values than other groups for each CAD/CAM material. According to surface topography (Sa) values, highest values were 2.936 ± 1.25 for Cerasmart, 2.633 ± 1.28 for Lava Ultimate and 3.489 ± 0.57 for Shofu Block HC. For Cerasmart, LAVA Ultimate and Shofu blocks, Group-1 exhibited significantly higher Sa values than other groups (p < 0.001). CONCLUSION: Optiglaze Color, Sof-Lex Diamond and Identoflex Diamond Ceramic Polisher create smooth CAD/CAM resin surfaces. However, surface roughness values of Cosmedent Nano/Microhybrid Diamond and Diapolisher Paste applied specimens were high. According to Sa values, highest roughness values belong to Optiglaze Color.


Assuntos
Desenho Assistido por Computador , Polimento Dentário , Cerâmica , Resinas Compostas , Materiais Dentários , Teste de Materiais , Propriedades de Superfície
8.
J Prosthodont ; 28(2): e485-e490, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29430807

RESUMO

PURPOSE: To investigate the effect of sandblasting powder particles on microtensile bond strength (µTBS) of dual-cure adhesive cement to CAD/CAM blocks. MATERIALS AND METHODS: CAD/CAM blocks (Cerasmart, VITA, and LAVA) were cut in slabs and divided into groups: group 1, no sandblasting; group 2, sandblasted with 27-µm Al2 O3 ; group 3, sandblasted with 30-µm CoJet; group 4, sandblasted with 50-µm Al2 O3 . After sandblasting, all specimens were silanized and luted using dual-cure adhesive cement (G-CEM LinkForce). After 24 hours, bonded specimens were cut into 1 ± 0.2 mm2 sticks, and µTBS values were obtained (N = 30). Additionally, 132 CAD/CAM block sections were prepared for surface roughness testing and scanning electron microscopy (SEM) evaluations. Results were analyzed using Kruskal-Wallis One-way ANOVA and Dunn's Post Hoc Test (p < 0.05). RESULTS: Group 1 exhibited significantly lower µTBS than the other groups (p < 0.05). The highest bond strength values were obtained from group 4 (p > 0.05). For LAVA, µTBS values of specimens that were sandblasted with 50-µm Al2 O3 powder were significantly higher than 30-µm-SiO2 and 27-µm Al2 O3 (p < 0.05). CONCLUSIONS: The sand particles investigated (27-µm Al2 O3 , 30-µm SiO2 , or 50-µm Al2 O3 ) did not significantly affect µTBS results of CAD/CAM blocks for Cerasmart and VITA, although the results changed significantly for LAVA. The ideal bond protocol for CAD/CAM blocks is specific to the material used.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Corrosão Dentária/métodos , Materiais Dentários/química , Cimentos de Resina/química , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Pós/química , Dióxido de Silício/química , Propriedades de Superfície , Resistência à Tração
9.
Clin Oral Investig ; 19(9): 2187-99, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25802222

RESUMO

OBJECTIVES: To evaluate the medium-term clinical performance of direct composite build-ups for diastema closures and teeth recontouring using a nano and a nanohybrid composite in combination with three- or two-step etch-and-rinse adhesives following treatment with fixed orthodontic appliances. MATERIALS AND METHODS: A total of 30 patients (mean age, 19.5 years) received 147 direct composite additions for teeth recontouring and diastema closures. A nano and a nanohybrid composite (Filtek Supreme XT and CeramX Duo) were bonded to tooth structure by using a three-step (Scotchbond Multipurpose) or a two-step (XP Bond) etch and rinse adhesive. Ten out of 147 composite build-ups (composite addition) constituted tooth recontouring cases, and the remaining 137 constituted diastema closure cases. The restorations were evaluated by two experienced, calibrated examiners according to modified Ryge criteria at the following time intervals: baseline, 1, 2, 3, and 4 years. RESULTS: The 4-year survival rates were 92.8 % for Filtek Supreme XT/Scotchbond Multi-Purpose Plus and 93 % for CeramX Duo/XP Bond. Only ten restorations failed (5 Filtek Supreme XT and 5 CeramX Duo). Statistical analysis revealed no significant differences between the two composite-adhesive combinations with respect to color match, marginal discoloration, wear/loss of anatomical form, caries formation, marginal adaptation, and surface texture on comparing the five time periods (baseline, 1, 2, 3, and 4 years) CONCLUSIONS: The 4-year survival rates in the present study were favorable. The restorations exhibited excellent scores with regard to color match, marginal adaptation, surface texture, marginal discoloration, wear/loss of anatomical form, and caries formation, after 4 years of clinical evaluation. Clinical relevance An alternative clinical approach for correcting discrepancies in tooth size and form, such as performing direct composite restorations following fixed orthodontic treatment, may be an excellent and minimally invasive treatment.


Assuntos
Restauração Dentária Permanente/métodos , Diastema/terapia , Fechamento de Espaço Ortodôntico/métodos , Condicionamento Ácido do Dente , Adolescente , Adulto , Resinas Compostas/química , Cimentos Dentários/química , Adesivos Dentinários , Feminino , Humanos , Masculino , Nanoestruturas/química , Cimentos de Resina , Resultado do Tratamento
10.
J Esthet Restor Dent ; 25(5): 326-43, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24148983

RESUMO

STATEMENT OF PROBLEM: The choice of adhesive application methods could affect the microleakage of self-etch adhesives. PURPOSE: To evaluate the effect of acid-etching, doubling adhesive application time, doubling adhesive coating, and rebonding agent application on microleakage of self-etch adhesives in Class V cavities. MATERIALS AND METHODS: Seventy human third molars with Class V cavities assigned to five groups according to different adhesive application protocols for the three dentin adhesives (Clearfil S3 Bond, Kuraray Medical, Okayama, Japan; Optibond All-in-One, Kerr Corporation Orange, CA, USA; G-Aenial Bond, GC Corporation, Tokyo, Japan): group 1, manufacturer's recommendations; group 2, prior acid-etching of cavities; group 3, double application time; group 4, two consecutive coats of the adhesives; group 5, rebonding application on restoration margins. After bonding, the cavities were filled with a resin composite (Filtek Supreme XT, 3M ESPE Dental Products, St. Paul, MN, USA). The teeth were thermocycled, and the specimens were examined for microleakage using methylene blue as a marker. RESULTS: For Clearfil S3 Bond and Optibond All-in-One, microleakage in groups 2 and 5 were significantly lower than other groups' enamel margins. In groups 1, 2, 4, and 5, Clearfil S3 Bond exhibited significantly more leakage than the other dentin bonding agents in dentin margins. Microleakage was significantly higher on dentinal margins compared with the enamel margins for Clearfil S3 Bond in all of the groups. Optibond All-in-One showed significantly lower microleakage in dentin margins in all groups except groups 2 and 5. CONCLUSION: Acid-etching usually promoted the reduction of microleakage in enamel margins. On the other hand, rebonding application usually contributed to the reduction of microleakage more than other methods in enamel and dentin margins. CLINICAL RELEVANCE: Acid-etching or rebonding application may contribute to reduction of microleakage of all-in-one self-etching adhesives.


Assuntos
Condicionamento Ácido do Dente , Cimentos Dentários , Selantes de Fossas e Fissuras , Adesivos Dentinários , Humanos , Dente Serotino
11.
J Adhes Dent ; 24(1): 77-86, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35322945

RESUMO

PURPOSE: To evaluate the clinical performance of direct composite restorations using nanohybrid and nanofill composite materials in anterior teeth in patients with amelogenesis imperfecta (AI). MATERIALS AND METHODS: The study included 15 patients with AI aged 14-30 years. During the study, the patients received anterior direct composite laminate veneer restorations using either a nanohybrid (Clearfil Majesty ES-2 and Clearfil Universal Bond, Kuraray Noritake) or a nanofill resin composite (Filtek Ultimate Universal Restorative and Single Bond Universal Adhesive, 3M Oral Care). The restorations were evaluated according to the modified USPHS criteria at baseline and at 1-, 2-, 3- and 4-year follow-up periods. RESULTS: The cumulative success rate of anterior restorations was 80.5% for nanohybrid and 92.5% for nanofill composite after 4 years. Eight restorations with nanohybrid and three restorations with nanofill resin composites failed. Ten restorations failed due to fracture; the fracture rate was 12.3%. Statistically significant differences were found between nanohybrid and nanofill composites regarding marginal discoloration and surface texture after 3 years. Furthermore, statistically significant differences were observed with respect to color match after 4 years. CONCLUSION: The use of a nanohybrid or nanofill composite for anterior direct restorations in patients with AI was observed to be satisfactory, based on the rate of ideal and clinically acceptable restorations. The primary reason for restoration failure was fracture. The failure rate of nanohybrid composite restorations was higher than with nanofill composite restorations with respect to survival and marginal adaptation criteria.


Assuntos
Amelogênese Imperfeita , Adolescente , Adulto , Amelogênese Imperfeita/terapia , Restauração Dentária Permanente/métodos , Humanos , Propriedades de Superfície , Adulto Jovem
12.
Microsc Res Tech ; 84(4): 804-813, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33179843

RESUMO

This study aims to analyze and assess the effects of three particular dentin pretreatment solutions on the bond durability of a two-step self-etch adhesive (Optibond XTR) applied to dentin after ageing for 2 years. Thirty-five third molars which were extracted (n = 5 for µTBS, n = 2 for nanoleakage) were divided into five groups: Group 1:Control (no pretreatment), Group 2:17% EDTA, Group 3:2% CHX, Group 4:17% EDTA plus 2% CHX, Group 5: Q-Mix. After the pretreatments of dentin, the dentin adhesive was applied as per the guidelines provided by the manufacturer. Half of the specimens were subjected to µTBS tests for 24 hr, while the remaining half were subjected to the tests after being kept for 2 years in water storage. Also, nanoleakage was evaluated with FE-SEM by examining silver nitrate deposits. The data obtained were evaluated using a two-way analysis of variance and Tukey Post Hoc test. The dentin pretreatments did not affect the 24 hr and 2 years µTBS values for OptiBond XTR. At 24 hr, the EDTA + CHX group (50.3 ± 4.9) showed that the highest µTBS value was obtained. Water ageing significantly reduced the µTBS results and after 2 years the highest µTBS value was obtained from the Q-Mix group (37.7 ± 5.2). Different dentin pretreatments do not alter the 24-hr µTBS and were not able to preserve the bond strength after 2 years of ageing. Q-Mix was able to slow down the regression in the strength of the dentin bond as well as nanoleakage over time.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Dentina , Teste de Materiais , Cimentos de Resina , Resistência à Tração , Água
13.
J Adhes Dent ; 22(2): 127-137, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32322834

RESUMO

PURPOSE: To evaluate the clinical performance of direct posterior composite restorations with and without short glass-fiber (SGF) reinforced composite in endodontically treated teeth. MATERIALS AND METHODS: Twenty-four patients (mean age 32.5 years) were included in the study and two molars of each patient received endodontic treatment. After endodontic treatment, one tooth was restored with G-aenial Bond/fiber-reinforced composite (everX Posterior GC) using a microhybrid composite (G-aenial Posterior), and the other tooth was restored with G-aenial Bond/microhybrid composite (G-aenial Posterior). The modified USPHS criteria were used to evaluate the restorations at baseline, 1-, 2-, and 3-year follow-ups. RESULTS: The success rate of the everX Posterior and G-aenial Posterior restorations after 3 years was 78.3% and 91.3%, respectively. Five everX Posterior restorations and two G-aenial Posterior restorations failed. Based on the criteria used in this study, no significant differences between the two restorations were found at any evaluation time. CONCLUSION: All restorations showed acceptable clinical performance regarding all evaluation criteria, apart from the failed restorations. The main cause of restoration failure was restoration fracture. The failure rate of everX Posterior restorations was higher than G-aenial Posterior restorations.


Assuntos
Dente não Vital , Adulto , Resinas Compostas , Restauração Dentária Permanente , Humanos , Dente Molar
14.
J Adv Prosthodont ; 12(2): 89-99, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32377322

RESUMO

PURPOSE: The effects of four different self-adhesive resin cement materials on cell viability and apoptosis after direct and indirect exposure were evaluated using different cell culture techniques. MATERIALS AND METHODS: Self-adhesive cements were applied to NIH/3T3 mouse fibroblasts by the extract test method, cell culture inserts, and dentin barrier test method. After exposure periods of 24 h and 72 h, the cytotoxicity of these self-adhesive materials was evaluated using the MTT assay (viability) and the Annexin-V-FITC/PI staining (apoptosis). RESULTS: The lowest cell viability was found in cells exposed to BeautiCem SA for 24 h in the extract test method. Cell viability was reduced to 70.6% compared to negative controls. After the 72 h exposure period, viability rate of cell cultures exposed to BeautiCem SA decreased more than 2- fold (29.5%) while cells exposed to RelyX U200 showed the highest viability rate of 71.4%. In the dentin barrier test method, BeautiCem SA induced the highest number of cells in apoptosis after a 24 h exposure (4.1%). Panavia SA Cement Plus was the material that caused the lowest number of cells in apoptosis (1.5%). CONCLUSION: The used self-adhesive cements have showed different cytotoxic effects based on the evaluation method. As exposure time increased, the materials showed more cytotoxic and apoptotic effects. BeautiCem SA caused significantly more severe cytotoxic and apoptotic effects than other cements tested. Moreover, cements other than BeautiCem SA have caused necrotic cell death rather than apoptotic cell death.

15.
Odovtos (En línea) ; 26(1): 76-85, Jan.-Apr. 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558620

RESUMO

Abstract The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey's post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17±3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.


Resumen El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM diferentes: disco Katana Zirconia UTML, bloque IPS e.max CAD, bloque Shofu y bloque Vita Enamic. Cada material se dividió en siete subgrupos diferentes (N=70). El grupo 1 tenía una superficie limpia. Los otros grupos estaban compuestos por muestras que estaban contaminadas con saliva humana: grupo 2: control negativo (no limpio); grupo 3: limpiado con agua pulverizada; grupo 4: limpiado con etanol al 70%; grupo 5: limpiado con Ivoclean; grupo 6: limpiado con Katana Cleaner; y grupo 7: limpiado con ácido fosfórico. Después de los protocolos de descontaminación, los cilindros de composite de resina se adhirieron a las superficies CAD/CAM con una fina capa de cemento de resina de curado dual. Las muestras se almacenaron durante 24 horas a 37°C en agua destilada. Luego, fueron sometidos a una prueba de resistencia al corte (SBS). Se registraron los valores y se evaluaron los tipos de fracturas utilizando un microscopio. Los datos se analizaron mediante ANOVA de dos factores y la prueba post-hoc de Tukey. En general, todos los agentes descontaminantes mejoraron el SBS de los composites con los materiales Katana Zirconia UTML, IPS e.max y Vita Enamic (p<0,05). Sin embargo, para los materiales Shofu, las muestras del grupo 6 exhibieron valores de fuerza de unión significativamente más altos en comparación con las muestras del grupo 2 (p=0,026). Los valores más altos de SBS se observaron en el grupo tratado con ácido fosfórico en materiales de circonio Katana (26,45 ± 9,38 MPa), mientras que los valores más bajos se observaron en las muestras del grupo 2 en materiales Shofu (13,17 ± 3,40 MPa). Cada agente descontaminante mejoró la fuerza de unión de los composites a los materiales CAD/CAM contaminados. Si no se limpia la saliva antes del procedimiento adhesivo, los valores de SBS pueden disminuir. Todos los agentes descontaminantes se pueden utilizar de forma segura en superficies de circonio, cerámica de vidrio de disilicato de litio, cerámica híbrida y cerámica con infiltraciones de polímeros.

16.
J Adv Prosthodont ; 10(3): 211-217, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29930791

RESUMO

PURPOSE: To evaluate the effect of prolonged sandblasting on the bond durability of dual-cure adhesive resin cement to computer-aided design and computer-aided manufacturing (CAD/CAM) restoratives. MATERIALS AND METHODS: Nano-ceramic LAVA Ultimate and hybrid-ceramic VITA Enamic CAD/CAM blocks were used for this study. Each CAD/CAM block was sectioned into slabs of 4-mm thickness for the microtensile test (µTBS) test and 2-mm thickness for the surface roughness test. Three groups were created according to the sandblasting protocols; group 1: specimens were sandblasted for 15 seconds, group 2: specimens were sandblasted for 30 seconds, and group 3: specimens were sandblasted for 60 seconds. After sandblasting, all specimens were luted using RelyX Ultimate Clicker. Half the specimens were subjected to µTBS tests at 24 hours, and the other half were subjected to tests after 5000 thermocycles. Additionally, a total of 96 CAD/CAM block sections were prepared for surface roughness tests and scanning electron microscopy (SEM) evaluations. The Mann-Whitney U test, Kruskal-Wallis one-way analysis of variance, and Dunn's post hoc test were used to compare continuous variables among the groups. RESULTS: At baseline, group 1, group 2, and group 3 exhibited statistically similar µTBS results for LAVA. However, group 3 had significantly lower µTBS values than groups 1 and 2 for VITA. After 5000 thermocycles, µTBS values significantly decreased for each block (P<.05). CONCLUSION: It is important to perform controlled sandblasting because it may affect bond strength results. Sixty seconds of sandblasting disturbs the initial µTBS values and the stability of adhesion of CAD/CAM restoratives to dual-cure adhesive resin cement for VITA Enamic.

17.
J Adv Prosthodont ; 10(1): 50-57, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29503714

RESUMO

PURPOSE: To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS AND METHODS: Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (Ra and Rz) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test (P<.05). RESULTS: LAVA, VITA, and Cerasmart exhibited statistically similar Ra and Rz values for each group (P>.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher Ra values than Group 2 (P<.05). Group 1 (0.502 Ra), Group 2 (0.384 Ra), and Group 3 (0.431 Ra) exhibited statistically similar Ra values for LAVA (P=.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart (P>.05). CONCLUSION: Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

18.
Dent Mater J ; 36(2): 182-189, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28090033

RESUMO

The purpose of this study was to evaluate the effect of surface sealant application and 10,000 thermocycles on the surface roughness and microhardness of different resin composite systems. A micro-hybrid (G Aenial Posterior), a nano-hybrid (Clearfil Majesty Posterior), a nano-fill (Filtek Ultimate Universal Restorative, Enamel Shade), and a bulk-fill resin composite (Filtek Bulk Fill Posterior Restorative) were used for the study. Specimens were evaluated at 24 h, after application of the surface sealant Fortify Plus, and after thermocycling. Data were analyzed using two-way repeated measures of analysis of variance (ANOVA) and a posthoc Bonferroni test (p<0.05). Surface roughness values of G Aenial Posterior and Filtek Ultimate Universal Restorative increased significantly after surface sealant application. However, neither surface sealant application nor thermocycling had a significant effect on composite microhardness values except Filtek Ultimate Universal Restorative (p>0.05).


Assuntos
Selantes de Fossas e Fissuras , Resinas Compostas , Esmalte Dentário , Materiais Dentários , Humanos , Propriedades de Superfície
19.
J Clin Exp Dent ; 9(3): e424-e430, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28298986

RESUMO

BACKGROUND: This study aimed to evaluate the flexural strength and microhardness of three different anterior composites after 10 000 thermocycles. MATERIAL AND METHODS: The mechanical properties of a nano-fill composite (Filtek Ultimate Universal Restorative (FUR) (Enamel)), a nano-hybrid composite (Clearfil Majesty ES2 (ES2) (Enamel)), and a micro-hybrid composite (G Aenial Anterior (GAA)) were investigated in this study. For the microhardness test, 8-mm diameter and 2-mm thickness composite discs were used (n = 10), and for the flexural strength test, 25x2x2 mm bar-shaped specimens were prepared (n = 13). The specimens were tested at 24 h and after 10 000 thermocycles. Data were analyzed using two-way analysis of variance and the post-hoc Tukey test (p < .05). Correlations between hardness and flexural strength were calculated using Pearson's correlation analysis. RESULTS: There was a significant difference in the microhardness values of the materials (p < .05). FUR exhibited significantly higher microhardness than ES2 and GAA. However, the flexural strength of three composites was statistically similar at 24 h (p > .05). Pearson correlation analysis revealed that there was a negative relationship between the mean hardness and flexural strength values (correlation coefficient = -0.367, p = .043). After 10 000 thermocycles, microhardness values of each material and flexural strength of ES2 and GAA decreased significantly according to 24 h. CONCLUSIONS: The nano-fill composite FUR displayed significantly higher microhardness values. However, each resin composite was statistically similar for flexural strength values. Ten thousand thermocycles significantly affected microhardness and flexural strength. Key words:Flexural strength, microhardness, anterior composites.

20.
Restor Dent Endod ; 42(4): 253-263, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29142873

RESUMO

OBJECTIVES: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. MATERIALS AND METHODS: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. RESULTS: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. CONCLUSIONS: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa