Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
CA Cancer J Clin ; 69(2): 127-157, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30720861

RESUMO

Judgement, as one of the core tenets of medicine, relies upon the integration of multilayered data with nuanced decision making. Cancer offers a unique context for medical decisions given not only its variegated forms with evolution of disease but also the need to take into account the individual condition of patients, their ability to receive treatment, and their responses to treatment. Challenges remain in the accurate detection, characterization, and monitoring of cancers despite improved technologies. Radiographic assessment of disease most commonly relies upon visual evaluations, the interpretations of which may be augmented by advanced computational analyses. In particular, artificial intelligence (AI) promises to make great strides in the qualitative interpretation of cancer imaging by expert clinicians, including volumetric delineation of tumors over time, extrapolation of the tumor genotype and biological course from its radiographic phenotype, prediction of clinical outcome, and assessment of the impact of disease and treatment on adjacent organs. AI may automate processes in the initial interpretation of images and shift the clinical workflow of radiographic detection, management decisions on whether or not to administer an intervention, and subsequent observation to a yet to be envisioned paradigm. Here, the authors review the current state of AI as applied to medical imaging of cancer and describe advances in 4 tumor types (lung, brain, breast, and prostate) to illustrate how common clinical problems are being addressed. Although most studies evaluating AI applications in oncology to date have not been vigorously validated for reproducibility and generalizability, the results do highlight increasingly concerted efforts in pushing AI technology to clinical use and to impact future directions in cancer care.


Assuntos
Inteligência Artificial , Diagnóstico por Imagem/métodos , Neoplasias/diagnóstico por imagem , Humanos
2.
Magn Reson Med ; 91(2): 640-648, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37753628

RESUMO

PURPOSE: To demonstrate the technical feasibility and the value of ultrahigh-performance gradient in imaging the prostate in a 3T MRI system. METHODS: In this local institutional review board-approved study, prostate MRI was performed on 4 healthy men. Each subject was scanned in a prototype 3T MRI system with a 42-cm inner-diameter gradient coil that achieves a maximum gradient amplitude of 200 mT/m and slew rate of 500 T/m/s. PI-RADS V2.1-compliant axial T2 -weighted anatomical imaging and single-shot echo planar DWI at standard gradient of 70 mT/m and 150 T/m/s were obtained, followed by DWI at maximum performance (i.e., 200 mT/m and 500 T/m/s). In comparison to state-of-the-art clinical whole-body MRI systems, the high slew rate improved echo spacing from 1020 to 596 µs and, together with a high gradient amplitude for diffusion encoding, TE was reduced from 55 to 36 ms. RESULTS: In all 4 subjects (waist circumference = 81-91 cm, age = 45-65 years), no peripheral nerve stimulation sensation was reported during DWI. Reduced image distortion in the posterior peripheral zone prostate gland and higher signal intensity, such as in the surrounding muscle of high-gradient DWI, were noted. CONCLUSION: Human prostate MRI at simultaneously high gradient amplitude of 200 mT/m and slew rate of 500 T/m/s is feasible, demonstrating that improved gradient performance can address image distortion and T2 decay-induced SNR issues for in vivo prostate imaging.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Próstata/diagnóstico por imagem , Estudos de Viabilidade , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
World J Urol ; 41(5): 1309-1315, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36930254

RESUMO

PURPOSE: To describe the national-level patterns of care for local ablative therapy among men with PCa and identify patient- and hospital-level factors associated with the receipt of these techniques. METHODS: We retrospectively interrogated the National Cancer Database (NCDB) for men with clinically localized PCa between 2010 and 2017. The main outcome was receipt of local tumor ablation with either cryo- or laser-ablation, and "other method of local tumor destruction including high-intensity focused ultrasound (HIFU)". Patient level, hospital level, and demographic variables were collected. Mixed effect logistic regression models were fitted to identify separately patient- and hospital-level predictors of receipt of local ablative therapy. RESULTS: Overall, 11,278 patients received ablative therapy, of whom 78.8% had cryotherapy, 15.6% had laser, and 5.7% had another method including HIFU. At the patient level, men with intermediate-risk PCa were more likely to be treated with local ablative therapy (OR 1.05; 95% CI 1.00-1.11; p = 0.05), as were men with Charlson Comorbidity Index > 1 (OR 1.36; 95% CI 1.29-1.43; p < 0.01), men between 71 and 80 years (OR 3.70; 95% CI 3.43-3.99; p < 0.01), men with Medicare insurance (OR 1.38; 95% 1.31-1.46; p < 0.01), and an income < $47,999 (OR 1.16; 95% CI 1.06-1.21; p < 0.01). At the hospital-level, local ablative therapy was less likely to be performed in academic/research facilities (OR 0.45; 95% CI 0.32-0.64; p < 0.01). CONCLUSIONS: Local ablative therapy for PCa treatment is more commonly offered among older and comorbid patients. Future studies should investigate the uptake of these technologies in non-hospital-based settings and in light of recent changes in insurance coverage.


Assuntos
Terapia a Laser , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estados Unidos , Estudos Retrospectivos , Medicare , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Sistema de Registros
4.
Eur Radiol ; 33(11): 7360-7370, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37553488

RESUMO

OBJECTIVE: To identify variables predictive of durable clinical success after MRI-guided focused ultrasound (MRgFUS) treatment of uterine fibroids. MATERIALS AND METHODS: In this prospective, multicenter trial, 99 women with symptomatic uterine fibroids were treated using MRgFUS. Pelvic MRI was obtained at baseline and treatment day. The Uterine Fibroid Symptom-Quality of Life questionnaire was used to calculate a symptom severity score (SSS) at baseline and 6, 12, 24, and 36 months following treatment. Clinical, imaging, and treatment variables were correlated with symptom reduction sustained through the 12- and 24-month time points using univariable and multivariable logistic regression analyses. A novel parameter, the ratio of non-perfused volume to total fibroid load (NPV/TFL), was developed to determine association with durable outcomes. RESULTS: Post-treatment, mean symptom severity decreased at the 6-, 12-, 24-, and 36-month follow-ups (p < 0.001, all time points). In univariable analysis, three variables predicted treatment success (defined by ≥ 30-point improvement in SSS) sustained at both the 12-month and 24-month time points: increasing ratio of NPV/TFL (p = 0.002), decreasing total fibroid load (p = 0.04), and the absence of T2-weighted Funaki type 2 fibroids (p = 0.02). In multivariable analysis, the NPV/TFL was the sole predictor of durable clinical success (p = 0.01). Patients with ratios below 30% had less improvement in SSS and lacked durable clinical response compared with those between 30-79 (p = 0.03) and ≥ 80% (p = 0.01). CONCLUSION: Increased non-perfused volume relative to total fibroid volume was significantly associated with durable reduction of symptoms of abnormal uterine bleeding and bulk bother. CLINICAL RELEVANCE STATEMENT: Patient selection for sustained clinical benefit should emphasize those with likelihood of achieving high ablation ratios, as determined by imaging (e.g., device access, Funaki type) and by considering the total fibroid load, not just the primary symptomatic fibroid. TRIAL REGISTRATION: Clinical trial ID: NCT01285960. KEY POINTS: • Patient selection/treatment approach associated with durable symptom relief in MRI-guided focused ultrasound ablation of uterine fibroids remains unclear. • The ablation ratio, non-perfused volume/total fibroid volume, was positively associated with sustained symptom relief in both bleeding and bulk bother at 1- and 2-year follow-ups. • Selecting patients with imaging features that favor a high ratio of ablation to total fibroid load (including non-targeted fibroids) is the main factor in predicting durability of symptom relief after uterine fibroid treatment.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia
5.
Eur Radiol ; 33(1): 461-471, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35771247

RESUMO

OBJECTIVES: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant's ability to apply PI-QUAL. METHODS: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. RESULTS: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50-0.66]) to post-teaching (0.96 [0.92-0.98]), an improvement of 0.37 [0.21-0.41] (p < 0.001). CONCLUSIONS: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. KEY POINTS: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Bolsas de Estudo , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
6.
AJR Am J Roentgenol ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37877601

RESUMO

Multiparametric prostate MRI (mpMRI) aids risk stratification of patients with elevated PSA levels. While most clinically significant prostate cancers are detected by mpMRI, insignificant cancers are less evident. Thus, multiple international prostate cancer guidelines now endorse routine use of prostate MRI as a secondary screening test before prostate biopsy. Nonetheless, management of patients with negative mpMRI results (defined as PI-RADS category 1 or 2) remains unclear. This AJR Expert Panel Narrative Review summarizes the available literature on patients with an elevated screening PSA level and a negative prostate mpMRI, and provides guidance for these patients' management. Systematic biopsy should not be routinely performed after a negative mpMRI in patients at average risk but should be considered in patients at high risk. In patients who undergo PSA screening rather than systematic biopsy after negative mpMRI, clear triggers should be established for when to perform a repeat MRI. Patients with negative MRI followed by negative biopsy should follow their healthcare practitioners' preferred guidelines concerning subsequent PSA screening for the patient's risk level. Insufficient high-level data exist to support routine use of adjunctive serum or urine biomarkers, artificial intelligence, or PSMA PET to determine the need for prostate biopsy after negative mpMRI.

7.
Lancet Oncol ; 23(7): 910-918, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35714666

RESUMO

BACKGROUND: Men with grade group 2 or 3 prostate cancer are often considered ineligible for active surveillance; some patients with grade group 2 prostate cancer who are managed with active surveillance will have early disease progression requiring radical therapy. This study aimed to investigate whether MRI-guided focused ultrasound focal therapy can safely reduce treatment burden for patients with localised grade group 2 or 3 intermediate-risk prostate cancer. METHODS: In this single-arm, multicentre, phase 2b study conducted at eight health-care centres in the USA, we recruited men aged 50 years and older with unilateral, MRI-visible, primary, intermediate-risk, previously untreated prostate adenocarcinoma (prostate-specific antigen ≤20 ng/mL, grade group 2 or 3; tumour classification ≤T2) confirmed on combined biopsy (combining MRI-targeted and systematic biopsies). MRI-guided focused ultrasound energy, sequentially titrated to temperatures sufficient for tissue ablation (about 60-70°C), was delivered to the index lesion and a planned margin of 5 mm or more of normal tissue, using real-time magnetic resonance thermometry for intraoperative monitoring. Co-primary outcomes were oncological outcomes (absence of grade group 2 and higher cancer in the treated area at 6-month and 24-month combined biopsy; when 24-month biopsy data were not available and grade group 2 or higher cancer had occurred in the treated area at 6 months, the 6-month biopsy results were included in the final analysis) and safety (adverse events up to 24 months) in all patients enrolled in the study. This study is registered with ClinicalTrials.gov, NCT01657942, and is no longer recruiting. FINDINGS: Between May 4, 2017, and Dec 21, 2018, we assessed 194 patients for eligibility and treated 101 patients with MRI-guided focused ultrasound. Median age was 63 years (IQR 58-67) and median concentration of prostate-specific antigen was 5·7 ng/mL (IQR 4·2-7·5). Most cancers were grade group 2 (79 [78%] of 101). At 24 months, 78 (88% [95% CI 79-94]) of 89 men had no evidence of grade group 2 or higher prostate cancer in the treated area. No grade 4 or grade 5 treatment-related adverse events were reported, and only one grade 3 adverse event (urinary tract infection) was reported. There were no treatment-related deaths. INTERPRETATION: 24-month biopsy outcomes show that MRI-guided focused ultrasound focal therapy is safe and effectively treats grade group 2 or 3 prostate cancer. These results support focal therapy for select patients and its use in comparative trials to determine if a tissue-preserving approach is effective in delaying or eliminating the need for radical whole-gland treatment in the long term. FUNDING: Insightec and the National Cancer Institute.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Idoso , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia
8.
AJR Am J Roentgenol ; 216(1): 3-19, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32812795

RESUMO

The steadily increasing demand for diagnostic prostate MRI has led to concerns regarding the lack of access to and the availability of qualified MRI scanners and sufficiently experienced radiologists, radiographers, and technologists to meet the demand. Solutions must enhance operational benefits without compromising diagnostic performance, quality, and delivery of service. Solutions should also mitigate risks such as decreased reader confidence and referrer engagement. One approach may be the implementation of MRI without the use gadolinium-based contrast medium (bipara-metric MRI), but only if certain prerequisites such as high-quality imaging, expert interpretation quality, and availability of patient recall or on-table monitoring are mandated. Alternatively, or in combination, a clinical risk-based approach could be used for protocol selection, specifically, which biopsy-naive men need MRI with contrast medium (multiparametric MRI). There is a need for prospective studies in which biopsy decisions are made according to MRI without contrast enhancement. Such studies must define clinical and operational benefits and identify which patient groups can be scanned successfully without contrast enhancement. These higher-quality data are needed before the Prostate Imaging Reporting and Data System (PI-RADS) Committee can make evidence-based recommendations about MRI without contrast enhancement as an initial diagnostic approach for prostate cancer workup.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Humanos , Masculino , Valor Preditivo dos Testes
9.
Int J Cancer ; 144(3): 422-430, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30098215

RESUMO

Recognition of <3 metastases in <2 organs, particularly in cancers with a known predisposition to oligometastatic disease (OMD) (colorectal, prostate, renal, sarcoma and lung), offers the opportunity to focally treat the lesions identified and confers a survival advantage. The reliability with which OMD is identified depends on the sensitivity of the imaging technique used for detection and may be predicted from phenotypic and genetic factors of the primary tumour, which determine metastatic risk. Whole-body or organ-specific imaging to identify oligometastases requires optimization to achieve maximal sensitivity. Metastatic lesions at multiple locations may require a variety of imaging modalities for best visualisation because the optimal image contrast is determined by tumour biology. Newer imaging techniques used for this purpose require validation. Additionally, rationalisation of imaging strategies is needed, particularly with regard to timing of imaging and follow-up studies. This article reviews the current evidence for the use of imaging for recognising OMD and proposes a risk-based roadmap for identifying patients with true OMD, or at risk of metastatic disease likely to be OM.


Assuntos
Neoplasias/diagnóstico por imagem , Idoso de 80 Anos ou mais , Diagnóstico por Imagem/métodos , Humanos , Masculino , Metástase Neoplásica , Neoplasias/patologia , Imagem Corporal Total/métodos
10.
Radiology ; 292(2): 464-474, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31184561

RESUMO

High-quality evidence shows that MRI in biopsy-naive men can reduce the number of men who need prostate biopsy and can reduce the number of diagnoses of clinically insignificant cancers that are unlikely to cause harm. In men with prior negative biopsy results who remain under persistent suspicion, MRI improves the detection and localization of life-threatening prostate cancer with greater clinical utility than the current standard of care, systematic transrectal US-guided biopsy. Systematic analyses show that MRI-directed biopsy increases the effectiveness of the prostate cancer diagnosis pathway. The incorporation of MRI-directed pathways into clinical care guidelines in prostate cancer detection has begun. The widespread adoption of the Prostate Imaging Reporting and Data System (PI-RADS) for multiparametric MRI data acquisition, interpretation, and reporting has promoted these changes in practice. The PI-RADS MRI-directed biopsy pathway enables the delivery of key diagnostic benefits to men suspected of having cancer based on clinical suspicion. Herein, the PI-RADS Steering Committee discusses how the MRI pathway should be incorporated into routine clinical practice and the challenges in delivering the positive health impacts needed by men suspected of having clinically significant prostate cancer.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Sistemas de Informação em Radiologia , Humanos , Biópsia Guiada por Imagem , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia
11.
J Magn Reson Imaging ; 49(7): e14-e25, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30145852

RESUMO

There is increasing scrutiny from healthcare organizations towards the utility and associated costs of imaging. MRI has traditionally been used as a high-end modality, and although shown extremely important for many types of clinical scenarios, it has been suggested as too expensive by some. This editorial will try and explain how value should be addressed and gives some insights and practical examples of how value of MRI can be increased. It requires a global effort to increase accessibility, value for money, and impact on patient management. We hope this editorial sheds some light and gives some indications of where the field may wish to address some of its research to proactively demonstrate the value of MRI. Level of Evidence: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2019;49:e14-e25.


Assuntos
Imageamento por Ressonância Magnética/economia , Abdome/diagnóstico por imagem , Idoso , Mama/diagnóstico por imagem , Meios de Contraste , Feminino , Geografia , Custos de Cuidados de Saúde , Humanos , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Próstata/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Mecanismo de Reembolso , Projetos de Pesquisa , Adulto Jovem
12.
Cancer ; 124(17): 3528-3535, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29975404

RESUMO

BACKGROUND: Partial prostate treatment has emerged as a potential method for treating patients with favorable-risk prostate cancer while minimizing toxicity. The authors previously demonstrated poor rates of biochemical disease control for patients with National Comprehensive Cancer Network (NCCN) intermediate-risk disease using partial gland treatment with brachytherapy. The objective of the current study was to estimate the rates of distant metastasis and prostate cancer-specific mortality (PCSM) for this cohort. METHODS: Between 1997 and 2007, a total of 354 men with clinical T1c disease, a prostate-specific antigen (PSA) level < 15 ng/mL, and Gleason grade ≤3 + 4 prostate cancer underwent partial prostate treatment with brachytherapy to the peripheral zone under 0.5-Tesla magnetic resonance guidance. The cumulative incidences of metastasis and PCSM for the NCCN very low-risk, low-risk, and intermediate-risk groups were estimated. Fine and Gray competing risk regression was used to evaluate clinical factors associated with time to metastasis. RESULTS: A total of 22 patients developed metastases at a median of 11.0 years (interquartile range, 6.9-13.9 years). The 12-year metastasis rates for patients with very low-risk, low-risk, and intermediate-risk disease were 0.8% (95% confidence interval [95% CI], 0.1%-4.4%), 8.7% (95% CI, 3.4%-17.2%), and 15.7% (95% CI, 5.7%-30.2%), respectively, and the 12-year PCSM estimates were 1.6% (95% CI, 0.1%-7.6%), 1.4% (95% CI, 0.1%-6.8%), and 8.2% (95% CI, 1.9%-20.7%), respectively. On multivariate analysis, NCCN risk category (low risk: hazard ratio, 6.34 [95% CI, 1.18-34.06; P = .03] and intermediate risk: hazard ratio, 6.98 [95% CI, 1.23-39.73; P = .03]) was found to be significantly associated with the time to metastasis. CONCLUSIONS: Partial prostate treatment with brachytherapy may be associated with higher rates of distant metastasis and PCSM for patients with intermediate-risk disease after long-term follow-up. Treatment of less than the full gland may not be appropriate for this cohort.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Idoso , Braquiterapia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Conduta Expectante
13.
Magn Reson Med ; 79(4): 2346-2358, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28718517

RESUMO

PURPOSE: To compare the fitting and tissue discrimination performance of biexponential, kurtosis, stretched exponential, and gamma distribution models for high b-factor diffusion-weighted images in prostate cancer. METHODS: Diffusion-weighted images with 15 b-factors ranging from b = 0 to 3500 s/mm2 were obtained in 62 prostate cancer patients. Pixel-wise signal decay fits for each model were evaluated with the Akaike Information Criterion (AIC). Parameter values for each model were determined within normal prostate and the index lesion. Their potential to differentiate normal from cancerous tissue was investigated through receiver operating characteristic analysis and comparison with Gleason score. RESULTS: The biexponential slow diffusion fraction fslow , the apparent kurtosis diffusion coefficient ADCK , and the excess kurtosis factor K differ significantly among normal peripheral zone (PZ), normal transition zone (TZ), tumor PZ, and tumor TZ. Biexponential and gamma distribution models result in the lowest AIC, indicating a superior fit. Maximum areas under the curve (AUCs) of all models ranged from 0.93 to 0.96 for the PZ and from 0.95 to 0.97 for the TZ. Similar AUCs also result from the apparent diffusion coefficient (ADC) of a monoexponential fit to a b-factor sub-range up to 1250 s/mm2 . For kurtosis and stretched exponential models, single parameters yield the highest AUCs, whereas for the biexponential and gamma distribution models, linear combinations of parameters produce the highest AUCs. Parameters with high AUC show a trend in differentiating low from high Gleason score, whereas parameters with low AUC show no such ability. CONCLUSION: All models, including a monoexponential fit to a lower-b sub-range, achieve similar AUCs for discrimination of normal and cancer tissue. The biexponential model, which is favored statistically, also appears to provide insight into disease-related microstructural changes. Magn Reson Med 79:2346-2358, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Área Sob a Curva , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Distribuição Normal , Imagens de Fantasmas , Probabilidade , Curva ROC
15.
Radiology ; 285(2): 343-356, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29045233

RESUMO

Systematic transrectal ultrasonography (US)-guided biopsy is the standard approach for histopathologic diagnosis of prostate cancer. However, this technique has multiple limitations because of its inability to accurately visualize and target prostate lesions. Multiparametric magnetic resonance (MR) imaging of the prostate is more reliably able to localize significant prostate cancer. Targeted prostate biopsy by using MR imaging may thus help to reduce false-negative results and improve risk assessment. Several commercial devices are now available for targeted prostate biopsy, including in-gantry MR imaging-targeted biopsy and real-time transrectal US-MR imaging fusion biopsy systems. This article reviews the current status of MR imaging-targeted biopsy platforms, including technical considerations, as well as advantages and challenges of each technique. © RSNA, 2017.


Assuntos
Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Imagem Multimodal , Próstata/diagnóstico por imagem , Próstata/patologia , Ultrassonografia
16.
Gynecol Oncol ; 145(2): 284-290, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28318644

RESUMO

OBJECTIVE: The purpose was to compare local control (LC), overall survival (OS) and dose to the organs at risk (OAR) in women with locally advanced cervical cancer treated with MR-guided versus CT-guided interstitial brachytherapy (BT). METHODS: 56 patients (29 MR, 27 CT) were treated with high-dose-rate (HDR) interstitial BT between 2005-2015. The MR patients had been prospectively enrolled on a Phase II clinical trial. Data were analyzed using Kaplan-Meier (K-M) and Cox proportional hazards statistical modeling in JMP® & R®. RESULTS: Median follow-up time was 19.7months (MR group) and 18.4months (CT group). There were no statistically significant differences in patient age at diagnosis, histology, percent with tumor size >4cm, grade, FIGO stage or lymph node involvement between the groups. Patients in the MR group had more lymphovascular involvement compared to patients in the CT group (p<0.01). When evaluating plans generated, there were no statistically significant differences in median cumulative dose to the high-risk clinical target volume or the OAR. 2-year K-M LC rates for MR-based and CT-based treatments were 96% and 87%, respectively (log-rank p=0.65). At 2years, OS was significantly better in the MR-guided cohort (84% vs. 56%, p=0.036). On multivariate analysis, squamous histology was associated with longer OS (HR 0.23, 95% CI 0.07-0.72) in a model with MR BT (HR 0.35, 95% CI 0.08-1.18). There was no difference in toxicities between CT and MR BT. CONCLUSION: In this population of locally advanced cervical-cancer patients, MR-guided HDR BT resulted in estimated 96% 2-year local control and excellent survival and toxicity rates.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Relação Dose-Resposta à Radiação , Feminino , Humanos , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Resultado do Tratamento , Neoplasias do Colo do Útero/patologia
17.
AJR Am J Roentgenol ; 209(3): W145-W151, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28657843

RESUMO

OBJECTIVE: The purpose of this study is to determine the interobserver agreement of the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for diagnosing prostate cancer using in-bore MRI-guided prostate biopsy as the reference standard. MATERIALS AND METHODS: Fifty-nine patients underwent in-bore MRI-guided prostate biopsy between January 21, 2010, and August 21, 2013, and underwent diagnostic multiparametric MRI 6 months or less before biopsy. A single index lesion per patient was selected after retrospective review of MR images. Three fellowship-trained abdominal radiologists (with 1-11 years' experience) blinded to clinical information interpreted all studies according to PI-RADSv2. Interobserver agreement was assessed using Cohen kappa statistics. RESULTS: Thirty-eight lesions were in the peripheral zone and 21 were in the transition zone. Cancer was diagnosed in 26 patients (44%). Overall PI-RADS scores were higher for all biopsy-positive lesions (mean ± SD, 3.9 ± 1.1) than for biopsy-negative lesions (3.1 ± 1.0; p < 0.0001) and for clinically significant lesions (4.2 ± 1.0) than for clinically insignificant lesions (3.1 ± 1.0; p < 0.0001). Overall suspicion score interobserver agreement was moderate (κ = 0.45). There was moderate interobserver agreement among overall PI-RADS scores in the peripheral zone (κ = 0.46) and fair agreement in the transition zone (κ = 0.36). CONCLUSION: PI-RADSv2 scores were higher in the biopsy-positive group. PI-RADSv2 showed moderate interobserver agreement among abdominal radiologists with no prior experience using the scoring system.


Assuntos
Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Cancer ; 121(6): 817-27, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25204551

RESUMO

The authors review methods for image-guided diagnosis and therapy that increase precision in the detection, characterization, and localization of many forms of cancer to achieve optimal target definition and complete resection or ablation. A new model of translational, clinical, image-guided therapy research is presented, and the Advanced Multimodality Image-Guided Operating (AMIGO) suite is described. AMIGO was conceived and designed to allow for the full integration of imaging in cancer diagnosis and treatment. Examples are drawn from over 500 procedures performed on brain, neck, spine, thorax (breast, lung), and pelvis (prostate and gynecologic) areas and are used to describe how they address some of the many challenges of treating brain, prostate, and lung tumors. Cancer 2015;121:817-827. © 2014 American Cancer Society.


Assuntos
Diagnóstico por Imagem/métodos , Imagem Multimodal/métodos , Neoplasias/diagnóstico , Diagnóstico por Imagem/instrumentação , Humanos , Imagem Multimodal/instrumentação , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Radiografia
19.
Radiology ; 274(1): 170-80, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25222067

RESUMO

PURPOSE: To determine the detection rate, clinical relevance, Gleason grade, and location of prostate cancer ( PCa prostate cancer ) diagnosed with and the safety of an in-bore transperineal 3-T magnetic resonance (MR) imaging-guided prostate biopsy in a clinically heterogeneous patient population. MATERIALS AND METHODS: This prospective retrospectively analyzed study was HIPAA compliant and institutional review board approved, and informed consent was obtained. Eighty-seven men (mean age, 66.2 years ± 6.9) underwent multiparametric endorectal prostate MR imaging at 3 T and transperineal MR imaging-guided biopsy. Three subgroups of patients with at least one lesion suspicious for cancer were included: men with no prior PCa prostate cancer diagnosis, men with PCa prostate cancer who were undergoing active surveillance, and men with treated PCa prostate cancer and suspected recurrence. Exclusion criteria were prior prostatectomy and/or contraindication to 3-T MR imaging. The transperineal MR imaging-guided biopsy was performed in a 70-cm wide-bore 3-T device. Overall patient biopsy outcomes, cancer detection rates, Gleason grade, and location for each subgroup were evaluated and statistically compared by using χ(2) and one-way analysis of variance followed by Tukey honestly significant difference post hoc comparisons. RESULTS: Ninety biopsy procedures were performed with no serious adverse events, with a mean of 3.7 targets sampled per gland. Cancer was detected in 51 (56.7%) men: 48.1% (25 of 52) with no prior PCa prostate cancer , 61.5% (eight of 13) under active surveillance, and 72.0% (18 of 25) in whom recurrence was suspected. Gleason pattern 4 or higher was diagnosed in 78.1% (25 of 32) in the no prior PCa prostate cancer and active surveillance groups. Gleason scores were not assigned in the suspected recurrence group. MR targets located in the anterior prostate had the highest cancer yield (40 of 64, 62.5%) compared with those for the other parts of the prostate (P < .001). CONCLUSION: In-bore 3-T transperineal MR imaging-guided biopsy, with a mean of 3.7 targets per gland, allowed detection of many clinically relevant cancers, many of which were located anteriorly.


Assuntos
Biópsia Guiada por Imagem , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/patologia , Idoso , Meios de Contraste , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Períneo , Estudos Prospectivos
20.
J Magn Reson Imaging ; 42(1): 63-71, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25263213

RESUMO

PURPOSE: To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. MATERIALS AND METHODS: This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. RESULTS: In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). CONCLUSION: The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer.


Assuntos
Marcadores Fiduciais , Biópsia Guiada por Imagem/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Neoplasias da Próstata/patologia , Robótica/instrumentação , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade , Períneo/patologia , Reprodutibilidade dos Testes , Robótica/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa