Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Neuroradiol ; 33(3): 701-708, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36856786

RESUMO

INTRODUCTION: Combined stent-retriever/large-bore distal aspiration catheter (LB-DAC) thrombectomy was recently introduced to treat large-vessel occlusion; however, it is unclear whether larger inner diameters improve outcomes. We compared angiographic and clinical outcomes in patients with occlusions of the M1 segment of the middle cerebral artery treated with mechanical thrombectomy using extra-LB-DAC versus LB-DAC in combination with stent-retrievers. METHODS: We analyzed consecutive patients with M1 occlusion included in the ROSSETTI registry treated with non-balloon guide catheter combined LB-DAC/stent-retriever thrombectomy between June 2019 and April 2022. We compared demographics, baseline clinical variables, procedural variables, angiographic outcomes, and clinical outcomes [National Institute of Health Stroke Scale score at 24 h (24h-NIHSS) and modified Rankin scale score at 3 months] between patients treated with extra-LB-DAC (Sofia Plus, MIVI Q6, Catalyst7; inner diameter, 0.068″-0.070″) versus LB-DAC (Sofia 5F, MIVI Q5, Catalyst 6; inner diameter, 0.055″-0.064″). Primary outcome was the first-pass effect (FPE) rate, defined as near-complete/complete reperfusion (mTICI 2c-3) after a single pass of the device. RESULTS: We included 324 patients (extra-LB-DAC, 185, 57.1% patients). Demographics, clinical data, and clinical outcomes were similar between the two groups; however, there was a trend towards improvement in National Institute of Health Stroke Scale score at 24 h (24h-NIHSS) in the cohort treated with extra-LB-DAC 9 points (IQR 4;16 points) vs. 12 points (IQR 4;18 points, P = 0.083). Patients treated with extra-LB-DAC had higher FPE rate (47% vs. 30.9%; P = 0.003) and higher modified FPE (mTICI ≥ 2b after a single pass) rate (65.9% vs 46.8%; P = 0.001). The use of extra-LB-DAC was an independent factor in predicting FPE (odds ratio 1.982, 95% confidence interval 1.250-3.143, P = 0.004). CONCLUSION: Our results suggest that in combined LB-DAC/stent-retriever thrombectomy, a larger aspiration catheter inner diameter is associated with higher rates of FPE and mFPE.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Isquemia Encefálica/terapia , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , AVC Isquêmico/etiologia , Catéteres , Angiografia Cerebral , Stents/efeitos adversos , Estudos Retrospectivos
2.
AJNR Am J Neuroradiol ; 40(5): 769-775, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31000524

RESUMO

BACKGROUND AND PURPOSE: Predicting motor outcome following intracerebral hemorrhage is challenging. We tested whether the combination of clinical scores and DTI-based assessment of corticospinal tract damage within the first 12 hours of symptom onset after intracerebral hemorrhage predicts motor outcome at 3 months. MATERIALS AND METHODS: We prospectively studied patients with motor deficits secondary to primary intracerebral hemorrhage within the first 12 hours of symptom onset. Patients underwent multimodal MR imaging including DTI. We assessed intracerebral hemorrhage and perihematomal edema location and volume, and corticospinal tract involvement. The corticospinal tract was considered affected when the tractogram passed through the intracerebral hemorrhage or/and the perihematomal edema. We also calculated affected corticospinal tract-to-unaffected corticospinal tract ratios for fractional anisotropy, mean diffusivity, and axial and radial diffusivities. Motor impairment was graded by the motor subindex scores of the modified NIHSS. Motor outcome at 3 months was classified as good (modified NIHSS 0-3) or poor (modified NIHSS 4-8). RESULTS: Of 62 patients, 43 were included. At admission, the median NIHSS score was 13 (interquartile range = 8-17), and the median modified NIHSS score was 5 (interquartile range = 2-8). At 3 months, 13 (30.23%) had poor motor outcome. Significant independent predictors of motor outcome were NIHSS and modified NIHSS at admission, posterior limb of the internal capsule involvement by intracerebral hemorrhage at admission, intracerebral hemorrhage volume at admission, 72-hour NIHSS, and 72-hour modified NIHSS. The sensitivity, specificity, and positive and negative predictive values for poor motor outcome at 3 months by a combined modified NIHSS of >6 and posterior limb of the internal capsule involvement in the first 12 hours from symptom onset were 84%, 79%, 65%, and 92%, respectively (area under the curve = 0.89; 95% CI, 0.78-1). CONCLUSIONS: Combined assessment of motor function and posterior limb of the internal capsule damage during acute intracerebral hemorrhage accurately predicts motor outcome.


Assuntos
Hemorragia Cerebral/patologia , Transtornos Motores/etiologia , Tratos Piramidais/patologia , Recuperação de Função Fisiológica , Idoso , Hemorragia Cerebral/complicações , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Tratos Piramidais/diagnóstico por imagem
3.
Interv Neuroradiol ; 23(4): 362-370, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28587530

RESUMO

Background Intracranial wide-neck aneurysms at the arterial bifurcations, especially in the aneurysms where the bifurcating branches emanate directly from the base of the aneurysm, have been particularly difficult on which to perform endovascular treatment. The 'Y'-configuration, double stent-assisted coil embolization is an option for the treatment of these difficult aneurysms, allowing the closure of the aneurysm, preserving the parent arteries. Material and methods In a nine-year period, 546 intracranial aneurysms in 493 patients were treated at our center by endovascular approach. We have reviewed the medical records and arteriographies from November 2007 to January 2017 of 45 patients who were treated using 'Y'-configuration double Neuroform® stent-assisted coil embolization. Results All patients were successfully treated. The location of the aneurysms were: middle cerebral artery (MCA) 20 (44.4%), anterior communicating artery (AComA) 17 (37.7%), basilar four (8.9%), internal carotid artery (ICA) bifurcation three (6.6%) and posterior communicating artery (PComA) one (2.2%). The mRS at hospital discharge was: mRS 0: 42 (93.3%), mRS 1: 1 (2.2%), mRS 2: 1 (2.2%) and mRS 5: 1 (2.2%). The Modified Raymond-Roy Occlusion Classification, in the control at six months, was: Class I: 41 (91.1%), Class II: 2 (4.4%), Class IIIa: 1 (2.2%) and Class IIIb: 1 (2.2%). Forty-four (97.8%) patients had a good outcome (mRS < 2) at six months. One (2.2%) patient had a poor outcome (mRS > 2) at six months that was due to sequelae of SAH. There was no mortality at six months. Conclusions This technique is safe and effective for the endovascular treatment of difficult wide-neck bifurcation aneurysms, allowing the stable closure of the aneurysm, preserving the parent arteries.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Radiografia Intervencionista , Stents , Angiografia Cerebral , Feminino , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
4.
Interv Neuroradiol ; 23(5): 531-537, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28732458

RESUMO

Background The endovascular therapy for cerebral venous sinus thrombosis (CVST) is currently accepted as a second-line treatment for patients who have failed or those in whom systemic anticoagulation is contraindicated or in a subgroup of patients presenting with rapid neurologic deterioration. A number of different mechanical and pharmacologic endovascular strategies have been reported, either as separate or combined approaches. These new catheters and aspiration systems have a high power and vacuum capacity, which carries a risk of anemization of the patient and hypovolemic shock, being necessitating the transfusion of the patient. Material and methods Because of the problems that donor blood transfusion can bring, we describe the use of a Sorin Xtra® Autotransfusion System (ATS). This complete autologous blood recovery system was designed for use in procedures where medium- to high-volume blood loss occurs, such as major surgeries. We have adapted it to recover all the blood aspirated during the mechanical thrombectomy procedures of the dural cerebral venous sinuses, since they are procedures that can cause a significant loss of blood. One advantage to this is the patient receives his or her own blood instead of donor blood, so there is no risk of contracting outside diseases or transfusion reactions. Conclusions This technical note describes a novel and previously unpublished technical approach to CVST that can be immediately applied to clinical practice. It also raises awareness among the interventional neuroradiologist and anesthesiologist communities about novel, potentially lifesaving endovascular treatments in patients with extensive CVST.


Assuntos
Transfusão de Sangue Autóloga/instrumentação , Recuperação de Sangue Operatório/instrumentação , Trombose dos Seios Intracranianos/terapia , Trombectomia/métodos , Angiografia Cerebral , Terapia Combinada , Traumatismos Craniocerebrais/complicações , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Trombose dos Seios Intracranianos/diagnóstico por imagem , Trombose dos Seios Intracranianos/etiologia , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa