Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Osteoporos Int ; 35(2): 317-326, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37819401

RESUMO

We examined incidence rates (IR) for all distal radius fracture (DRF) events based on inpatient and outpatient data from a large statutory health insurance in Germany. Of all DRF, 56% were treated as inpatients, and thus, 44% treated as outpatients. IR were higher in women than in men. PURPOSE: Although a distal radius fracture (DRF) is one of the most common fractures in the elderly population, epidemiological data are limited. Many studies examine only hospitalized patients, do not analyze time trends, or include only small populations. In this retrospective population-based observational study, routine data on inpatient and outpatient care of persons aged ≥ 60 years insured by a large statutory health insurance in Germany were analyzed from 2014 to 2018. METHODS: DRF were identified by ICD-10 codes. All DRF events of an individual were considered with a corresponding individual washout period. Incidence rates (IR) and time trends were estimated assuming a Poisson distribution per 100,000 person-years, with 95% confidence intervals [95% CI] and age-sex standardization to the German population in 2018. Associations of calendar year, age, sex, and comorbidity with IR were examined using Poisson regression estimating incidence rate ratios (IRR) with CI. RESULTS: The study population consists of 974,332 insured individuals, with 16,557 experiencing one or more DRF events during the observation period. A total of 17,705 DRF events occurred, of which 9961 (56.3%) were hospitalized. Standardized IR were 439 [424-453] (inpatient: 240 [230-251], outpatient: 199 [189-209]) in 2014 and 438 [423-452] (inpatient: 238 [227-249], outpatient: 200 [190-210]) in 2018. Female sex, older age, and comorbidity were associated with higher IR and adjusted Poisson regression showed no significant time trend (IRR overall 0.994 [0.983-1.006]). CONCLUSION: A relevant proportion of DRF were treated in outpatient settings, so both inpatient and outpatient data are necessary for a valid estimate.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Masculino , Humanos , Idoso , Feminino , Estudos Retrospectivos , Incidência , Pacientes Ambulatoriais , Pacientes Internados , Fraturas do Rádio/epidemiologia
2.
J Thromb Thrombolysis ; 57(2): 179-185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37839024

RESUMO

Hemodynamic stabilization plays a crucial role in the treatment of patients suffering from severe trauma. Current guidelines recommend the early administration of tranexamic acid (TXA) for bleeding control. While less blood loss can result in less end-organ damage, including myocardial injury, TXA also exhibits prothrombotic effects with potentially adverse myocardial effects. The aim of this study was to investigate the association between the administration of TXA and myocardial injury in patients with severe trauma. We conducted a monocentric cohort study including severely injured patients ≥ 18 years [defined by Injury severity score (ISS) ≥ 16], who were admitted to a tertiary care hospital between 2016 and 2019. Primary outcome measure was myocardial injury according to the fourth Universal Definition (= high sensitive troponin T ≥ 14 ng/l). Secondary endpoints were in-hospital major adverse cardiovascular events (MACE) and mortality. Main exposure was defined as administration of TXA during prehospital period. We conducted multivariate logistic regression models including predefined covariables. A total of 368 patients were screened. Among the 297 included patients (72% male, age. 55?21 years), 119 (40%) presented myocardial injury at hospital arrival. TXA was administered to 20/297 (7%) patients in the prehospital setting, and in 96/297 (32%) patients during pre-or in-hospital period. MACE incidence was 9% (26/297) and in-hospital mortality was 26% (76/297). The adjusted odds ratios (OR) for prehospital TXA and myocardial injury, MACE and mortality were 0.75 [95% confidence interval (CI): 0.25-2.23], 0.51 [95%CI: 0.06-4.30] and 0.84 [0.21-3.33], respectively. In the present cohort of patients suffering from severe trauma, prehospital TXA did not affect the incidence of myocardial injury.


Assuntos
Antifibrinolíticos , Ácido Tranexâmico , Ferimentos e Lesões , Humanos , Masculino , Feminino , Ácido Tranexâmico/efeitos adversos , Antifibrinolíticos/uso terapêutico , Estudos de Coortes , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Mortalidade Hospitalar
3.
Skeletal Radiol ; 53(4): 791-800, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37819279

RESUMO

OBJECTIVE: Clinical-standard MRI is the imaging modality of choice for the wrist, yet limited to static evaluation, thereby potentially missing dynamic instability patterns. We aimed to investigate the clinical benefit of (dynamic) real-time MRI, complemented by automatic analysis, in patients with complete or partial scapholunate ligament (SLL) tears. MATERIAL AND METHODS: Both wrists of ten patients with unilateral SLL tears (six partial, four complete tears) as diagnosed by clinical-standard MRI were imaged during continuous active radioulnar motion using a 1.5-T MRI scanner in combination with a custom-made motion device. Following automatic segmentation of the wrist, the scapholunate and lunotriquetral joint widths were analyzed across the entire range of motion (ROM). Mixed-effects model analysis of variance (ANOVA) followed by Tukey's posthoc test and two-way ANOVA were used for statistical analysis. RESULTS: With the increasing extent of SLL tear, the scapholunate joint widths in injured wrists were significantly larger over the entire ROM compared to those of the contralateral healthy wrists (p<0.001). Differences between partial and complete tears were most pronounced at 5°-15° ulnar abduction (p<0.001). Motion patterns and trajectories were altered. Complete SLL deficiency resulted in complex alterations of the lunotriquetral joint widths. CONCLUSION: Real-time MRI may improve the functional diagnosis of SLL insufficiency and aid therapeutic decision-making by revealing dynamic forms of dissociative instability within the proximal carpus. Static MRI best differentiates SLL-injured wrists at 5°-15° of ulnar abduction.


Assuntos
Articulações do Carpo , Instabilidade Articular , Traumatismos do Punho , Humanos , Articulação do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Articulações do Carpo/diagnóstico por imagem , Ligamentos Articulares/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Instabilidade Articular/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem
4.
Arch Orthop Trauma Surg ; 144(1): 239-250, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37838983

RESUMO

INTRODUCTION: Thoracolumbar spine fractures often require surgical treatment as they are associated with spinal instability. Optimal operative techniques and treatment are discussed controversially. Aim of our prospective cohort study was to investigate the sagittal alignment after reduction, the secondary loss of reduction and the subjective outcome as well as the causal correlation of these parameters after minimally invasive stabilization of thoracic and lumbar fractures with polyaxial pedicle screws. MATERIALS AND METHODS: In a single-center study, a total of 78 patients with an average age of 61 ± 17 years who suffered a fracture of the thoracic or lumbar spine were included and subjected to a clinical and radiological follow-up examination after 8.5 ± 8 months. The kyphotic deformity was measured by determining the vertebral body angle, the mono- and bi-segmental wedge angle at three time points. The patients' subjective outcome was evaluated by the VAS spine score. RESULTS: After surgical therapy, a significant reduction of the traumatic kyphotic deformity was shown with an improvement of all angles (vertebral body angle: 3.2° ± 4.4°, mono- and bi-segmental wedge angle: 3.1° ± 5.6°, 2.0° ± 6.3°). After follow-up, a significant loss of sagittal alignment was observed for all measured parameters with a loss of correction. However, no correlation between the loss of reduction and the subjective outcome regarding the VAS spine scale could be detected. CONCLUSION: The minimally invasive dorsal stabilization of thoracic and lumbar spine fractures with polyaxial pedicle screws achieved a satisfactory reduction of the fracture-induced kyphotic deformity immediately postoperatively with a floss of reduction in the further course. However, maybe the main goal of this surgical procedure should be the prevention of a complete collapse of the vertebral body instead of a long-lasting restoration of anatomic sagittal alignment. LEVEL OF EVIDENCE: II.


Assuntos
Fraturas Ósseas , Ilusões , Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/complicações , Parafusos Pediculares/efeitos adversos , Corpo Vertebral , Estudos Prospectivos , Vértebras Torácicas/cirurgia , Vértebras Torácicas/lesões , Fraturas Ósseas/complicações , Vértebras Lombares/cirurgia , Vértebras Lombares/lesões , Cifose/etiologia , Cifose/cirurgia , Resultado do Tratamento , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
5.
Int J Mol Sci ; 24(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37894778

RESUMO

Dupuytren's disease (DD) is a fibroproliferative disorder affecting the palmar fascia, causing functional restrictions of the hand and thereby limiting patients' daily lives. The disturbed and excessive myofibroblastogenesis, causing DD, is mainly induced by transforming growth factor (TGF)-ß1. But, the extent to which impaired TGF-ß1 release or TGF-ß signal degradation is involved in pathologically altered myofibroblastogenesis in DD has been barely examined. Therefore, the complex in which TGF-ß1 is secreted in the extracellular matrix to elicit its biological activity, and proteins such as plasmin, integrins, and matrix metalloproteinases (MMPs), which are involved in the TGF-ß1 activation, were herein analyzed in DD-fibroblasts (DD-FBs). Additionally, TGF-ß signal degradation via caveolin-1 was examined with 5-fluoruracil (5-FU) in detail. Gene expression analysis was performed via Western blot, PCR, and immunofluorescence analyses. As a surrogate parameter for disturbed myofibroblastogenesis, 𝛼-smooth-muscle-actin (𝛼-SMA) expression was evaluated. It was demonstrated that latency-associated peptide (LAP)-TGF-ß and latent TGF-ß-binding protein (LTBP)-1 involved in TGF-ß-complex building were significantly upregulated in DD. Plasmin a serinprotease responsible for the TGF-ß release was significantly downregulated. The application of exogenous plasmin was able to inhibit disturbed myofibroblastogenesis, as measured via 𝛼-SMA expression. Furthermore, a reduced TGF-ß1 degradation was also involved in the pathological phenotype of DD, because caveolin-1 expression was significantly downregulated, and if rescued, myofibroblastogenesis was also inhibited. Therefore, our study demonstrates that a deficient release and degradation of TGF-ß1 are important players in the pathological phenotype of DD and should be addressed in future research studies to improve DD therapy or other related fibrotic conditions.


Assuntos
Contratura de Dupuytren , Humanos , Contratura de Dupuytren/genética , Contratura de Dupuytren/metabolismo , Contratura de Dupuytren/patologia , Fator de Crescimento Transformador beta1/genética , Fator de Crescimento Transformador beta1/metabolismo , Caveolina 1/genética , Caveolina 1/metabolismo , Fibrinolisina/metabolismo , Fibroblastos/metabolismo , Fator de Crescimento Transformador beta/genética , Fator de Crescimento Transformador beta/metabolismo , Células Cultivadas
6.
Eur Spine J ; 22(6): 1354-61, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23479027

RESUMO

PURPOSE: Leg length inequalities (LLIs) can result in an increased energy consumption, abnormal gait or osteoarthritis of the hip. In a previous study we simulated different LLIs of up to 15 mm and evaluated their effects on the pelvic position and spinal posture. We found a correlation between LLIs and resulting changes of the pelvic position. Despite suggestions in the literature we were not able to detect significant changes of the spinal posture. Therefore, the purpose of this study was to determine the amount of LLI that would in fact alter the spinal posture. METHODS: The subjects were placed on a simulation platform, whose height could be precisely controlled by the measuring device, to simulate different LLIs of up to 20 mm. For LLIs >20 mm, additional precision-cut wooden blocks were used under one foot. After an adaptation period the resulting changes of the pelvis and spine were measured with a rasterstereographic device. RESULTS: We found a significant correlation between platform height changes and changes of the pelvic position. The frontal spinal parameters surface rotation and lateral deviation changed significantly when simulating differences greater than 20 mm. No changes of the sagittal spinal curvature were measured, however, a trend to decreasing kyphotic angles was noted. CONCLUSIONS: Our study has shown for the first time that LLIs >20 mm will lead to significant changes in the spinal posture of healthy test subjects. However, these changes were only found in frontal (surface rotation and lateral flexion) spinal parameters, but not in sagittal parameters. Here for the kyphotic angle only a tendency to decreasing angles was noted. We have also found a significant correlation between different leg lengths and changes of the pelvic position. Further, females and males seem to react in the same way to LLIs.


Assuntos
Desigualdade de Membros Inferiores/complicações , Postura/fisiologia , Coluna Vertebral/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pelve/fisiologia
7.
Knee Surg Sports Traumatol Arthrosc ; 21(2): 311-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22491707

RESUMO

PURPOSE: A bilateral fixed-angle plate was biomechanically compared to the two currently preferred methods of osteosynthesis for transverse patella fractures. It was hypothesized that the new angle-stable implant would provide a secure and sustainable fracture fixation, superior to the established standard techniques. METHODS: Twenty-one identical patellae made of polyurethane foam (Sawbones(®)), osteotomized to create a transverse two-part fracture, were fixed with modified anterior tension wiring, cannulated lag screws with anterior tension wiring or bilateral polyaxial 2.7-mm fixed-angle plates. The testing protocol consisted of 10,000 repetitive cycles using a non-destructive physiological load between 100 and 300 N at a simulated knee flexion of 60°. RESULTS: All 21 Sawbone(®)-patellae sustained repetitive loading up to 10,000 cycles without failing. The anterior tension wire group displayed significant displacement of the fracture gap (0.7 ± 0.2 mm) during cyclic loading, while both lag screws with tension wiring and bilateral fixed-angle plates showed no fracture gap widening at all (p < 0.01). CONCLUSION: The bilateral fixed-angle plate and cannulated lag screws with anterior tension wiring preserved a constantly reduced fracture gap over 10,000 tensile cycles in contrast to modified anterior tension wiring, which exhibited significant widening of the gap after initial loading. Results of in vitro testing indicate that bilateral fixed-angle plates provide sustainable fixation stability offering a promising new option in the treatment for transverse patella fractures.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Patela/lesões , Patela/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fios Ortopédicos , Fraturas Ósseas/fisiopatologia , Humanos , Modelos Anatômicos , Patela/fisiopatologia
8.
J Pediatr Orthop ; 33(4): 409-14, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23653031

RESUMO

BACKGROUND: Arthroscopic suture fixation of tibial eminence fractures using FiberWire is a favorable therapeutic option. The application of biodegradable material may be of advantage especially during childhood. The aim of this study was to evaluate the biomechanical properties using the biodegradable suture materials PDS II and Vicryl compared with FiberWire. METHODS: Bone mineral density was evaluated by pqCT in 18 human knee specimens and 3 similar groups were formed. A standardized anterior tibial eminence fracture was created and suture fixation was performed using each suture material (PDS II, Vicryl, FiberWire) in 6 specimens. Cyclic testing and destructive loading to failure was conducted. RESULTS: Both testing modalities showed PDS II to be inferior to the other evaluated suture materials. Although significantly higher failure loads were seen with FiberWire sutures, Vicryl yielded comparable stiffness in load-to-failure testing. No significant differences between Vicryl and FiberWire could be observed under nondestructive cyclic conditions. CONCLUSIONS: Even though FiberWire yields a superior ultimate failure load, Vicryl presented comparable results under cyclic conditions. CLINICAL RELEVANCE: For tibial eminence fractures in children, Vicryl should be considered as an alternative biodegradable suture material. The use of PDS II cannot be advocated.


Assuntos
Implantes Absorvíveis , Densidade Óssea , Suturas , Fraturas da Tíbia/cirurgia , Artroscopia/métodos , Criança , Humanos , Osteotomia/métodos , Técnicas de Sutura , Tomografia Computadorizada por Raios X
9.
Eur J Trauma Emerg Surg ; 49(1): 217-225, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35920849

RESUMO

PURPOSE: During resuscitation of patients with severe trauma, guidelines recommend permissive hypotension prior to surgical bleeding control. However, hypotension may be associated with reduced organ perfusion and multiple organ dysfunction, e.g. myocardial injury. The association between hypotension and myocardial injury in trauma patients is underexplored. We hypothesized that hypotension is associated with myocardial injury in this population. MATERIALS AND METHODS: This retrospective study included patients ≥ 18 years suffering from severe trauma [defined as Injury Severity Score (ISS) ≥ 16] that were treated in the emergency department resuscitation room between 2016 and 2019. Primary endpoint was the incidence of myocardial injury defined as high-sensitive troponin T > 14 ng/l. Main exposure was the duration of arterial hypotension during resuscitation period defined as mean arterial pressure < 65 mmHg. RESULTS: Out of 368 patients screened, 343 were analyzed (73% male, age: 55 ± 21, ISS: 28 ± 12). Myocardial injury was detected in 143 (42%) patients. Overall in-hospital mortality was 26%. Multivariate binary logistic regression with forced entry of nine predefined covariables revealed an odds ratio of 1.29 [95% confidence interval 1.16-1.44]; p = 0.012) for the association between the duration of hypotension and myocardial injury. CONCLUSION: The duration of hypotension during resuscitation period is independently associated with the incidence of myocardial injury in patients with severe trauma.


Assuntos
Traumatismos Cardíacos , Hipotensão , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Hipotensão/etiologia , Hemorragia/complicações , Serviço Hospitalar de Emergência , Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/etiologia , Escala de Gravidade do Ferimento
10.
Genes (Basel) ; 14(3)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36980996

RESUMO

Multiple synostoses syndrome (OMIM: #186500, #610017, #612961, #617898) is a genetically heterogeneous group of autosomal dominant diseases characterized by abnormal bone unions. The joint fusions frequently involve the hands, feet, elbows or vertebrae. Pathogenic variants in FGF9 have been associated with multiple synostoses syndrome type 3 (SYNS3). So far, only five different missense variants in FGF9 that cause SYNS3 have been reported in 18 affected individuals. Unlike other multiple synostoses syndromes, conductive hearing loss has not been reported in SYNS3. In this report, we describe the clinical and selected radiological findings in a large multigenerational family with a novel missense variant in FGF9: c.430T>C, p.(Trp144Arg). We extend the phenotypic spectrum of SYNS3 by suggesting that cleft palate and conductive hearing loss are part of the syndrome and highlight the high degree of intrafamilial phenotypic variability. These findings should be considered when counseling affected individuals.


Assuntos
Perda Auditiva Condutiva , Sinostose , Humanos , Família Estendida , Fator 9 de Crescimento de Fibroblastos , Perda Auditiva Condutiva/genética , Mutação de Sentido Incorreto , Síndrome
11.
Knee Surg Sports Traumatol Arthrosc ; 20(10): 2092-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22203047

RESUMO

PURPOSE: Displaced tibial eminence fractures require surgical fixation in order to obtain a stable knee joint. Suture fixation with FiberWire(®) seems to be the most favorable therapeutic option. Biomechanical studies show failure of this technique most commonly due to a suture cutout with subsequent fracture of the tibial eminence fragment. The goal of this study is to compare the biomechanical properties of three different techniques of suture fixation using FiberWire(®). METHODS: Bone mineral density was evaluated in 18 human knee specimens by pqCT, and three similar groups were formed. A standardized anterior tibial eminence fracture was created, and suture fixation was performed using one of three different techniques in 6 specimens each. Cyclic and destructive testing was conducted. RESULTS: Significant differences between the three techniques could be shown neither in the cycles needed to achieve a steady state nor in a failure load or initial stiffness. Almost all specimens failed by suture cutout. CONCLUSION: The presented modification of the existing technique for suture fixation of tibial eminence fractures did not lead to an increased initial stability nor did it lower the rate of suture cutout. All tested suture techniques showed comparable initial stiffness and failure load.


Assuntos
Artroscopia/métodos , Fixação Interna de Fraturas/métodos , Traumatismos do Joelho/cirurgia , Técnicas de Sutura , Fraturas da Tíbia/cirurgia , Artroscopia/instrumentação , Fenômenos Biomecânicos , Fixação Interna de Fraturas/instrumentação , Humanos , Técnicas In Vitro , Técnicas de Sutura/instrumentação , Suturas , Suporte de Carga
12.
Int Orthop ; 36(3): 627-32, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21935622

RESUMO

PURPOSE: Treatment of acute subcutaneous Achilles tendon rupture remains challenging. Whereas the results of conservative and operative treatment are inconsistent, early mobilisation treatment seems to be beneficial. Besides suture repair, operative treatment using adhesives reveals promising results. Our hypothesis was that a gluing technique provides initial stability comparable to sutures. METHODS: In a biomechanical study, 18 fresh frozen sheep Achilles tendons were used to compare the biomechanical properties of suture repair using PDS® II and Bunnell's technique to tendon gluing using BioGlue® and Tissucol®. Load to failure testing was performed. RESULTS: Ultimate failure loads of sutures (146.2 ± 30.8 N) are significantly superior to the techniques using BioGlue® (38.4 ± 18.3 N; p <0.0001) or Tissucol® (4.7 ± 2.5 N; p <0.0001). Interestingly, no significant differences in stiffness were found between the application of BioGlue® and PDS® II. CONCLUSIONS: Suture repair provides significantly superior biomechanical properties compared to the use of both tested adhesives BioGlue® and Tissucol®. Based on the presented data we recommend the use of suture material for open Achilles tendon repair.


Assuntos
Tendão do Calcâneo/cirurgia , Materiais Biocompatíveis , Teste de Materiais , Traumatismos dos Tendões/cirurgia , Adesivos Teciduais , Tendão do Calcâneo/lesões , Animais , Fenômenos Biomecânicos , Análise de Falha de Equipamento , Ruptura , Ovinos , Âncoras de Sutura , Técnicas de Sutura
13.
Arch Orthop Trauma Surg ; 132(1): 57-63, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21877127

RESUMO

INTRODUCTION: A tibial nail with fixed-angle locking screws intends to combine the advantages of angular stability and intramedullary stabilization in extraarticular proximal tibial fractures. The goal of this study is to analyze if the angle stable tibial nail (ASN) is biomechanically more stable than an established conventional standard nail (CN). METHODS: Two types of nails were compared on a series of ten matched pairs of human tibiae. After setting a proximal tibial defect fracture, the intramedullary stabilized tibiae were axially loaded starting from 100 N increasing in steps of 100 N after every 200 cycles until failure was reached. Failure was defined as deformation of the fracture gap, fracturing of the bone or the implant. RESULTS: The two types of nails showed no significant difference in terms of maximum tolerated load, maximum cycles repeated or axial deformation of the bone-implant construct. The mean load at failure was 1,365 N for the CN and 1,195 N for the ASN. The mean axial deformation for conventional (19 mm) and angle stable nail (21 mm) did not differ significantly. Slightly less nail or screw loosening was noticed with the fixed-angle nail. CONCLUSION: No significant difference in stability between the two compared implants could be demonstrated. A trend could be shown indicating that the rate of nail loosening in the proximal osteotomized part of the bone was lower for the angle stable nail. This trend, however, could not be substantiated statistically.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Tíbia/lesões , Tíbia/fisiologia , Tíbia/cirurgia , Suporte de Carga
14.
Syst Rev ; 11(1): 199, 2022 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-36089599

RESUMO

BACKGROUND: The Calcaneus is the largest bone of the foot and the most frequent tarsal bone to be fractured. Overall, it causes round about 10 cases per 100,000 residents per year mainly in men. Especially displaced intra-articular calcaneus fractures often have early and late complications and its associated disability. There are various strategies for the treatment of displaced intra-articular calcaneus fractures, but the gold standard is still subject of a long-standing controversy. Minimally invasive procedures became more common in an attempt to reduce the high rate of complications associated with open reduction and internal fixation. With the increase in minimally invasive techniques, screw fixation also gained in significance. The current literature does not sufficiently elucidate whether the screw fixation is superior to other treatment options especially in relation to adverse events, health-related quality of life and postoperative pain. This study aims to investigate benefits and harms of treating displaced intra-articular calcaneus fractures (types II, III and IV according to Sanders) with screw fixation in adults. METHODS: A systematic review will be conducted based on the principles described in the Cochrane Handbook. We will include adults with displaced intra-articular calcaneus fractures of Sanders type II, III and IV. The surgical method of screw fixation shall be compared to other surgical interventions to stabilise calcaneus fractures. Primary outcomes are serious adverse events, health-related quality of life and postoperative pain level. MEDLINE, CENTRAL, CINAHL, Web of Science and bibnet.org, ClinicalTrial.gov and the World Health Organization International Clinical Trials Registry Platform (ICTR) will be searched. Screening and data extraction will be performed by two authors independently. A third author will arbitrate disputes. Risk of Bias will be assessed with the Cochrane tool. Meta-analysis will be performed if participants, interventions, comparisons and outcomes are sufficiently similar to ensure a result that is clinically meaningful. DISCUSSION: Due to the increasing use of minimally invasive techniques and the increasing use of screw fixation instead of open reduction and plate fixation, it is important to analyse the benefits and harms of screw fixation for calcaneus fractures. Screw fixation could, in the future, help to operate in a less invasive and tissue preserving manner while still achieving an adequate functional result for the patient SYSTEMATIC REVIEW REGISTRATION: CRD42021244695.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Fraturas Ósseas , Fraturas Intra-Articulares , Adulto , Parafusos Ósseos , Calcâneo/cirurgia , Fraturas Ósseas/cirurgia , Humanos , Fraturas Intra-Articulares/cirurgia , Masculino , Metanálise como Assunto , Dor Pós-Operatória , Qualidade de Vida , Revisões Sistemáticas como Assunto
15.
Artigo em Inglês | MEDLINE | ID: mdl-35692287

RESUMO

Objective: For proximal humeral fractures open reduction und internal fixation (ORIF) with a fixed-angle plate is considered the gold standard for surgical management. However, it can lead to poor functional outcomes and is associated with postoperative complications. Therefore, the purpose of this study was to investigate the influence of fracture severity by applying a new classification (simple versus complex) on clinical outcome and quality of life after ORIF of proximal humerus fractures. Methods: We conducted a prospective clinical study with an average follow-up period of 12 (SD 1) months after ORIF of proximal humeral fractures with a fixed-angle plate. The postoperative function and quality of life was measured using the Oxford Shoulder Score (OSS) and the Constant Score. Data was tested for statistical significance with the Mann-Whitney test and Fisher's exact test. Based on the findings of this study a simplified fracture classification system has been developed. Results: Seventy-two patients with a mean age of 65 years (SD 12) with 69% being males were included. According to the Neer classification, 35% (n=25) non-displaced ("one-part fractures"), 19% (n=14) two-part fractures, 15% (n=11) three-part fractures and 31% (n=22) four-part fractures were detected. Regarding the AO/OTA classification, 18% (n=13) were type A fractures, 43% (n=31) type B and 39% (n=28) type C fractures. From these criteria we derived our own fracture classification, including 50% (n=36) simple and 50% (n=36) severe fractures. Patients with simple fracture types achieved significantly higher total values in the Constant Score as well as the OSS (p=0.008; p=0.013). The cumulative incidence of complications in the entire patient collective was 14% (n=10) with humeral head necrosis (n=5) occurring only in the severe fracture group. Conclusions: The postoperative clinical outcome as well as the incidence of humeral head necrosis after ORIF of proximal humeral fractures with a fixed-angle plate correlates with the fracture type and severity. The newly derived fracture classification into simple and severe fractures is suitable with regard to clinical results and complication rate. However, prospective studies comparing ORIF vs. conservative treatment of proximal humeral fractures of the same severity are required. Level of Evidence: III.

16.
Eur J Trauma Emerg Surg ; 48(4): 3073-3079, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34878581

RESUMO

PURPOSE: Severe trauma can lead to end organ damages of varying severity, including myocardial injury. In the non-cardiac surgery setting, there is extensive evidence that perioperative myocardial injury is associated with increased morbidity and mortality. The impact of myocardial injury on outcome after severe trauma has not been investigated adequately yet. We hypothesized that myocardial injury is associated with increased in-hospital mortality in patients with severe trauma. MATERIALS/METHODS: This retrospective cohort study included patients ≥ 18 years with severe trauma [defined as injury severity score (ISS) ≥ 16] that were admitted to the resuscitation room of the Emergency Department of the University Hospital Duesseldorf, Germany, between 2016 and 2019. The main endpoint was in-hospital mortality. Main exposure was myocardial injury at arrival [defined as high-sensitive troponin T (hsTnT) > 14 ng/l]. For statistical analysis, receiver operating characteristic curve (ROC) and multivariate binary logistic regression were performed. RESULTS: Out of 368 patients, 353 were included into statistical analysis (72.5% male, age: 55 ± 21, ISS: 28 ± 12). Overall in-hospital mortality was 26.1%. Myocardial injury at presentation was detected in 149 (42.2%) patients. In-hospital mortality of patients with and without myocardial injury at presentation was 45% versus 12.3%, respectively. The area under the curve (AUC) for hsTnT and mortality was 0.76 [95% confidence interval (CI) 0.71-0.82]. The adjusted odds ratio of myocardial injury for in-hospital mortality was 2.27 ([95%CI 1.16-4.45]; p = 0.017). CONCLUSION: Myocardial injury after severe trauma is common and independently associated with in-hospital mortality. Thus, hsTnT might serve as a new prognostic marker in this cohort.


Assuntos
Troponina T , Adulto , Idoso , Feminino , Humanos , Incidência , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Estudos Retrospectivos
17.
Exp Ther Med ; 24(6): 752, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36561969

RESUMO

While hyperthermic intraperitoneal applications have demonstrated high efficacy in treating peritoneal metastases (PM), these applications are limited to temperatures of 41-43˚C to prevent a harmful increase in core temperature. However, since gaseous substances display low specific heat capacities, gas-based hyperthermia could potentially increase surface temperatures without affecting the body's core temperature. To the best of our knowledge, the present study is the first to explore the in vivo feasibility of gas-based hyperthermia via spatial and time-based distribution. In the present study, a temperature-isolated, abdominal box model was created with fresh peritoneal tissue exposed to continuous high-volume airflow temperatures ranging between 47 and 69˚C. Heat conduction within the peritoneal tissues was measured using temperature microsensors. Temperature build-up at different time points during the procedure was calculated and the safest option to perform gas-based intraperitoneal hyperthermia beyond 43˚C was identified using an in vivo swine model. In subsequent experiments, viability and cytotoxicity of HT-29 colon cancer cells were measured following short-term hyperthermia. The present study demonstrated that the application of gas-based intraperitoneal hyperthermia with temperatures up to 50˚C is possible without increasing the core temperature to harmful levels. Gas-based intraperitoneal hyperthermia can induce a histological reaction on the peritoneal surface, and it can also result in decreased viability and increased cytotoxicity of HT-29 cells. The concept of extreme hyperthermia may be of great clinical importance as it could significantly increase local cytotoxicity in PM without increasing the body's core temperature. Further studies are required to investigate the benefits, as well as the restrictions, of this novel concept.

18.
J Clin Med ; 11(24)2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36556048

RESUMO

BACKGROUND: Severe trauma potentially results in end-organ damage such as myocardial injury. Data suggest that myocardial injury is associated with increased mortality in this cohort, but the association with the incidence of in-hospital major adverse cardiac events (MACE) remains undetermined. METHODS: Retrospective cohort study including adult patients with severe trauma treated at the University Hospital Duesseldorf between January 2016 and December 2019. The main exposure was myocardial injury at presentation. Endpoints were in-hospital incidence of MACE and incidence of acute kidney injury (AKI) within 72 h. Discrimination of hsTnT for MACE and AKI was examined by the receiver operating characteristic curve (ROC) and the area under the curve (AUC). We conducted multivariate logistic regression analysis. RESULTS: We included 353 patients in our final analysis (72.5% male (256/353), age: 55 ± 21 years). The AUC for hsTnT and MACE was 0.68 [95% confidence interval (CI): 0.59-0.78]. The AUC for hsTnT and AKI was 0.64 [95% (CI): 0.55-0.72]. The adjusted odds ratio (OR) for myocardial injury and MACE was 2.97 [95% (CI): 1.31-6.72], and it was 2.14 [95% (CI): 1.03-4.46] for myocardial injury and AKI. CONCLUSION: Myocardial injury at presentation in patients with severe trauma is independently associated with the incidence of in-hospital MACE and AKI.

19.
Front Oncol ; 12: 953920, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36303827

RESUMO

Background: 43°Celsius (C) is currently the highest temperature used in the treatment of peritoneal metastasis (PM). Despite sufficient data on water- based hyperthermic solutions in PM treatment, there is currently no information on gas-based hyperthermia extending beyond 43°C. This study is the first to provide in-vivo data on different organ systems during and after intraperitoneal gas-based hyperthermia beyond 43°C. The aim of this study is to explore in-vivo feasibility, safety, and efficacy of this novel concept from a biological perspective. Methods: For this study, three swine were subjected to laparoscopy and subsequent gas-based intraperitoneal hyperthermia at 48°, 49° and 50°C under a high-flow air stream. Intraoperative data from multiple temperature sensors were analysed. Additionally, intraoperative anaesthesiologic and gasometrical data was analysed. Postoperatively, swine were monitored for one week and laboratory work-up was performed on postoperative days 1, 3 and 7. Results: During gas-based intraperitoneal hyperthermia, anesthesiologic parameters did not exhibit critical values. No intra- or postoperative complications were observed. Distinct temperature measurements on the skin, cystohepatic triangle and esophagus did not display any temperature increase. Postoperative laboratory workup did not show any changes in hemoglobin, white blood cell count, platelets, or kidney function. Discussion: Based on our data, there are no safety concerns for the application of gas-based hyperthermia between 48 - 50°C. In fact, no critical systemic temperature increase was observed. With respect to possible limitations, further in-vivo studies are required to evaluate whether gas-based intraperitoneal hyperthermia may be a therapeutic option for PM patients.

20.
J Trauma ; 70(4): 832-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21248651

RESUMO

BACKGROUND: A distal femur nail with fixed-angle locking screws intends to combine the advantages of angular stability and intramedullary stabilization in extraarticular distal femur fractures. The goal of this study was to analyze whether the locked compression distal femur nail (LCN) was biomechanically more stable than a conventional standard distal femur nail (CN). METHODS: Both nails were compared on a series of 10 matched pairs of human femora. After setting a distal femur defect fracture, the intramedullary stabilized femur was axially loaded starting from 100 N, increasing in steps of 100 N after every 200 cycles with a triangular frequency of 1 Hz, until a predefined point of failure was reached. RESULTS: The two types of nails showed no significant difference in terms of maximum tolerated load, maximum number of cycles repeated, or axial deformation of the bone-implant construct. The mean load at failure was 2,954 N for the CN and 2,483 N for the LCN. The mean axial deformation for the conventional (14.8 mm) and locked compression nail (15.3 mm) did not differ significantly. Mode of failure was a bony fracture in all specimens predominantly involving the proximal femur. CONCLUSIONS: No significant difference in stability between the two compared implants could be demonstrated. The LCN showed comparable characteristics under cyclic axial loading as the conventional distal femur nail. No migration into the articular space or implant failure was observed.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Fraturas do Fêmur/fisiopatologia , Humanos , Masculino , Teste de Materiais , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa