Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 148: 106220, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37944227

RESUMO

The present work aims to investigate whether it is possible to identify and quantify the contributions of the interstitial fluid and the solid skeleton to the overall time-dependent behavior of tendons based on a single mechanical test. For this purpose, the capabilities of three different time-dependent models (a viscoelastic, a poroelastic and a poroviscoelastic) were investigated in the modeling of the experimental behavior obtained from semi-confined compression with stress relaxation tests transverse to collagen fibers. The main achieved result points out that the poroviscoelastic model was the only one capable to characterize both the experimental responses of the force and volume changes of the tissue samples. Moreover, further analysis of this model shows that while the kinematics of the sample are mainly governed by the fluid flow (pore pressure contribution of the model), the behavior intrinsically associated with the viscoelastic solid skeleton makes a significant contribution to the experimental force response. This study reinforces the importance of taking both the experimental kinematics and kinetics of tendon tissues into account during the constitutive characterization procedure.


Assuntos
Modelos Biológicos , Tendões , Elasticidade , Estresse Mecânico , Viscosidade
2.
J Mech Behav Biomed Mater ; 140: 105703, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36764169

RESUMO

The mass density of highly hydrated soft tissues is generally assumed to be very close to that of the water, resulting that the fluid mass fraction (water content) being equal to the fluid volume fraction. Within this context, the present study aims to investigate whether such an assumption actually holds for tendon tissues and to what extent it may affect the constitutive characterizations based on biphasic (poroelastic) models. Once the water content was assessed by a classical drying assay, the fluid volume fraction was obtained based on an image segmentation approach. The main achieved results point out that the fluid volume fraction is ∼20% higher than the water content in the studied tendons (flexor digitorum profundus bovine tendons). Based on this, it is shown that the use of the water content instead of the fluid volume fraction may considerably bias the results drawn by biphasic modeling of tendons. Accordingly, a proper measurement of the fluid volume fraction is then required.


Assuntos
Mãos , Tendões , Animais , Bovinos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa