Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Pacing Clin Electrophysiol ; 34(1): 72-5, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20946303

RESUMO

INTRODUCTION: The incidence, mechanisms, clinical associations, and outcomes in patients with late-onset (>3 months) atrioventricular (AV) block following heart transplantation are not well known. This study will characterize late-onset AV block following cardiac transplantation. METHODS: We retrospectively reviewed our databases to identify patients who required pacemakers for late-onset AV block postheart and heart-lung transplantation from January 1990 to December 2007. Orthotopic heart and heart-lung transplantation were separately analyzed. RESULTS: This study included 588 adults who received cardiac transplants over a 17-year period at our center (519 orthotopic, 64 heart-lung transplants, and five heterotopic heart transplants). Of the 519 patients with orthotopic heart transplant, 39 required pacing (7.5%), 17 (3.3%) within 3 months posttransplant, 11 (2.1%) for late-onset sinus node dysfunction (SND), 11 (2.1%) for late-onset AV block. Also, five patients (7.8%) out of 64 heart-lung transplants required pacemakers, two (3.1%) for late-onset SND, three (4.7%) for late-onset AV block. None of the five patients who underwent heterotopic transplant required cardiac pacing prior to or posttransplant. CONCLUSIONS: Late-onset AV block occurs in 2.4% of patients with orthotopic heart transplant or heart-lung transplant. AV block is predominantly intermittent and, often, does not progress to permanent AV block. There are no predictable factors for its onset.


Assuntos
Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/prevenção & controle , Estimulação Cardíaca Artificial/estatística & dados numéricos , Transplante de Coração/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Austrália/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 32(7): 879-87, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19572863

RESUMO

BACKGROUND: Nonpulsatile left ventricular assist devices (LVADs) are increasingly used for treatment of refractory heart failure. A majority of such patients have implanted cardiac devices, namely implantable cardioverter-defibrillators (ICDs) or cardiac resynchronization therapy-pacemaker (CRT-P) or cardiac resynchronization therapy-defibrillator (CRT-D) devices. However, potential interactions between LVADs and cardiac devices in this category of patients remain unknown. METHODS: We reviewed case records and device logs of 15 patients with ICDs or CRT-P or CRT-D devices who subsequently had implantation of a VentrAssist LVAD (Ventracor Ltd., Chatswood, Australia) as destination therapy or bridge to heart transplantation. Pacemaker and ICD lead parameters before and after LVAD implant were compared. In addition, ventricular tachyarrhythmia event logs and potential electromagnetic interference reports were evaluated. RESULTS: Right ventricular (RV) sensing decreased in the first 6 months post-LVAD. Mean R-wave amplitude preimplant was 10.9 +/- 5.25 mV compared with 7.2 +/- 3.4 mV during follow-up (P = 0.02). RV impedance also decreased from 642 +/- 240 ohms at baseline to 580 +/- 212 ohms at follow-up (P = 0.007). There was a significant increase in RV stimulation threshold following implantation of the LVAD from 0.8 +/- 0.6 V at baseline to 1.4 +/- 1.0 V in the first 6 months postimplant (P = 0.01). A marked increase in ventricular tachyarrhythmia burden was observed in three patients. One patient displayed electromagnetic interference between the LVAD and defibrillator, resulting in inappropriate defibrillation therapy. CONCLUSIONS: LVADs have a definite impact on cardiac devices in respect with alteration of lead parameters, ventricular tachyarrhythmias, and electromagnetic interference.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Adolescente , Adulto , Idoso , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
4.
J Am Coll Cardiol ; 49(5): 578-86, 2007 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-17276182

RESUMO

OBJECTIVES: This study sought to evaluate mutations in genes encoding the slow component of the cardiac delayed rectifier K+ current (I(Ks)) channel in familial atrial fibrillation (AF). BACKGROUND: Although AF can have a genetic etiology, links between inherited gene defects and acquired factors such as atrial stretch have not been explored. METHODS: Mutation screening of the KCNQ1, KCNE1, KCNE2, and KCNE3 genes was performed in 50 families with AF. The effects of mutant protein on cardiac I(Ks) activation were evaluated using electrophysiological studies and human atrial action potential modeling. RESULTS: One missense KCNQ1 mutation, R14C, was identified in 1 family with a high prevalence of hypertension. Atrial fibrillation was present only in older individuals who had developed atrial dilation and who were genotype positive. Patch-clamp studies of wild-type or R14C KCNQ1 expressed with KCNE1 in CHO cells showed no statistically significant differences between wild-type and mutant channel kinetics at baseline, or after activation of adenylate cyclase with forskolin. After exposure to hypotonic solution to elicit cell swelling/stretch, mutant channels showed a marked increase in current, a leftward shift in the voltage dependence of activation, altered channel kinetics, and shortening of the modeled atrial action potential duration. CONCLUSIONS: These data suggest that the R14C KCNQ1 mutation alone is insufficient to cause AF. Rather, we suggest a model in which a "second hit", such as an environmental factor like hypertension, which promotes atrial stretch and thereby unmasks an inherited defect in ion channel kinetics (the "first hit"), is required for AF to be manifested. Such a model would also account for the age-related increase in AF development.


Assuntos
Fibrilação Atrial/genética , Canal de Potássio KCNQ1/genética , Mutação de Sentido Incorreto/genética , Canais de Potássio de Abertura Dependente da Tensão da Membrana/fisiologia , Potenciais de Ação/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem
5.
Med J Aust ; 176(9): 429-30, 2002 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-12056995

RESUMO

This report describes ventricular tachycardia, likely to have been torsade de pointes, following ingestion of the non-sedating antihistamine loratadine. Documentation of the arrhythmia was made possible by the automatic electrogram storage facility of an implanted defibrillator in a patient with no prior history of cardiac arrhythmia.


Assuntos
Antagonistas dos Receptores Histamínicos H1/efeitos adversos , Loratadina/efeitos adversos , Taquicardia Ventricular/induzido quimicamente , Adulto , Desfibriladores Implantáveis , Feminino , Humanos , Torsades de Pointes/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa