Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Med Ultrasound ; 31(1): 29-34, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180617

RESUMO

Background: Gestational diabetes mellitus (GDM) is one of the most common medical conditions affecting pregnancy and significantly increasing the risk for maternal and perinatal complications. The aim of the present study is to study the correlation of fetal anterior abdominal wall thickness (FAAWT) and other standard fetal biometric parameters measured by ultrasound between 36 and 39 weeks of gestation with neonatal birth weight in pregnancies complicated by GDM. Methods: Prospective cohort study in a tertiary care center including 100 singleton pregnancies with GDM were subjected to ultrasound between 36 and 39 weeks of gestation. Standard fetal biometry (Biparietal diameter, Head Circumference, Abdominal circumference [AC], and Femur Length) and estimated fetal weight were calculated. FAAWT was measured at AC section and actual neonatal birth weights were recorded after delivery. Macrosomia was defined as an absolute birth weight more than 4000 g regardless of the gestational age. Statistical analysis was done and 95% confidence level was considered significant. Results: Among 100 neonates, 16 were macrosomic (16%) and third trimester mean FAAWT was significantly higher in macrosomic babies (6.36 ± 0.5 mm) as compared to nonmacrosomic babies (5.54 ± 0.61 mm) (P < 0.0001). FAAWT >6 mm (Receiver operating characteristic curve derived) provided a sensitivity of 87.5%, specificity of 75%, positive predictive value of 40%, and negative predictive value (NPV) of 96.9% for prediction of macrosomia. While other standard fetal biometric parameters did not correlate well with actual birth weight in macrosomic neonates, only FAAWT was found to have statistically significant correlation (correlation coefficient of 0.626, P = 0.009). Conclusion: The FAAWT was the only sonographic parameter to have a significant correlation with neonatal birth weight in macrosomic neonates of GDM mothers. We found a high sensitivity (87.5%), specificity (75%), and NPV (96.9%) suggesting that FAAWT < 6 mm can rule out macrosomia in pregnancies with GDM.

2.
J Med Ultrasound ; 29(1): 39-45, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34084715

RESUMO

BACKGROUND: The objective was to compare ultrasonographic findings with clinical and radiographic findings in osteoarthritis (OA)-affected knee joints. METHODS: This prospective study was conducted in Subharti Medical College, Meerut, after getting clearance from the ethical committee. Eighty-five symptomatic knees fulfilling American College of Rheumatology criteria for OA were included in the study. Patients with trauma, inflammatory, and infective conditions of the knee and with a history of intra-articular interventions and surgery were excluded. Demographic data, body mass index (BMI), visual analog scale (VAS), and Western Ontario and McMaster Universities Arthritis (WOMAC) questionnaire score were obtained. Kellgren-Lawrence (K-L) score was obtained on radiography. Ultrasonographic findings which were recorded include effusion, meniscal extrusion, femorotrochlear cartilage grading, maximum length of osteophytes at medial and lateral compartments, and presence or absence of Baker cyst. RESULTS: A total of 85 consecutive symptomatic knees were examined. The male: female ratio was 22:63, with a mean age of 54.52 ± 9.44 years, mean duration of disease of 24.24 ± 19.14 months, mean BMI of 28.91 ± 3.69 kg/m2, and mean score of VAS and WOMAC pain scale of 6.27 ± 1.45 and 62.45 ± 10.96, respectively. K-L grading of 1, 2, 3, and 4 was reported in 12.9%, 21.2%, 25.9%, and 40% of the knees, respectively. The mean VAS score and WOMAC score showed statistically significant correlation with KL grading (P < 0.05). Knees with the presence of osteophytes, medial meniscal extrusion, effusion, and medial femoral trochlear cartilage grading showed statistically significant correlation with VAS and WOMAC scores (P < 0.05). However, the correlation was not significant for lateral meniscus extrusion and lateral femoral trochlear cartilage grading. CONCLUSION: Our study found that K-L grading and few ultrasonographic criteria showed a significant positive correlation with pain scores, while few other ultrasonographic criteria did not. Both imaging modalities are complementary to each other, rather than one being superior to the other.

3.
Neurol India ; 66(2): 454-458, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29547171

RESUMO

BACKGROUND: Accurate and detailed measurements of spinal canal diameter (SCD) and transverse foraminal morphometry are essential for understanding spinal column-related diseases and for surgical planning, especially for transpedicular screw fixation. This is especially because lateral cervical radiographs do not provide accurate measurements. AIM:: This study was conducted to measure the dimensions of the transverse foramen sagittal and transverse diameters (SFD, TFD), SCD, and the distance of spinal canal from the transverse foramina (dSC-TF) at C1-C7 level in the Indian population. MATERIALS AND METHODS:: The study population comprised 84 male and 42 female subjects. The mean age of the study group was 44.63 years (range, 19-81 years). A retrospective study was conducted, and data were collected and analyzed for patients who underwent cervical spine computed tomography (CT) imaging for various reasons. RESULTS: One hundred and twenty-six patients were included in the study. Detailed readings were taken at all levels from C1-C7 for SCD, SFD, TFD, and dSc-TF. Values for male and female subjects were separately calculated and compared. For both the groups, the widest SCD were measured at the C1 level and the narrowest SCD at the C4 level. The narrowest SFD was measured at C7 for both male and female subjects on the right and left sides. The widest SFD was measured at C1 both for male and female subjects on the right and left side. The narrowest TFD on the left side was measured at C7 for male and at C1 for female subjects. The narrowest mean distance of dSC-TF was found to be at C4 for both male and female subjects on both left and right side. CONCLUSION: The computed tomographic (CT) imaging is better than conventional radiographs for the preoperative evaluation of cervical spine and for better understanding cervical spine morphometry. Care must be taken during transpedicular screw fixation, especially in female subjects, more so at the C2, C4, and C6 levels due to a decrease in the distance of dSC-TF.


Assuntos
Procedimentos Ortopédicos/métodos , Canal Medular/diagnóstico por imagem , Canal Medular/cirurgia , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/cirurgia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Vértebras Cervicais/diagnóstico por imagem , Feminino , Forame Magno , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Surg Radiol Anat ; 36(2): 199-202, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23670608

RESUMO

Supernumerary kidneys are a rare congenital anomaly with fewer than 100 cases reported over the years. A fused supernumerary kidney is a still rarer entity. We present imaging findings in two cases of supernumerary kidneys--the first case is a spectacular image of four kidneys in one patient seen in an excretory phase of intravenous urogram with only four cases described in the literature. The second case is that of three kidneys (fused supernumerary) seen in another patient.


Assuntos
Rim/anormalidades , Meios de Contraste , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Urografia/métodos
6.
Indian J Otolaryngol Head Neck Surg ; 71(Suppl 2): 1115-1122, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31750135

RESUMO

Various studies have shown variations in size and shape of different anthropometric measurements of external auditory canal. We conducted an anthropometric study of the three-dimensional anatomy of the osseous external auditory canal (OEAC) using high-resolution computed tomography the temporal bone to identify the variations in subset of Indian population from North India. A retrospective review of high-resolution computed tomography images of the temporal bones of 125 patients (250 external auditory canals) of different ages (mean 28.43 years) acquired from September 2014 to February of 2015 was performed. Using a method, as proposed by Mahboubio et al. (Otol Neurotol 33:715-720, 2012), six defined dimensions of the OEAC in the parasagittal planes were recorded at the level of annulus, midcanal and the outermost point of osseous external auditory canal at bony-cartilaginous junction. The length and shape of the OEAC were also studied and the frequency rate of each was recorded. The most prevalent shape of the OEAC was found to be conical (64%) and the mean osseous external auditory canal length was 9.61 mm. The length of the OEAC was significantly different between ages above and below 12 years while the 6 defined cross sectional dimensions were statistically significant between ages above and below 8 years. The history of chronic suppurative otitis media had a significant bearing on the inferior mid-anteroposterior dimension at the level of bony-cartilaginous junction. There was statistically significant difference in supero-inferior diameter in the posterior half at the level of mid-canal and outer bony-cartilaginous junction between males and females. The comprehensive set of standardized measurements collected in this study provides three-dimensional information on osseous external auditory canal geometry. These measurements and the methodology will contribute to the development of element models of the osseous canal for computational modeling purposes and also provide important measurements for design of in-the-canal hearing aids, specialized earplugs and for defining average sizes for canalplasty procedures, in pre- and postoperative surgical planning and assessment of canal atresia and stenosis in Indian population. No such previous study has been done in North Indian population.

11.
Indian J Radiol Imaging ; 26(3): 373-376, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27857465

RESUMO

Kawasaki disease is a systemic medium vessel vasculitis of unknown etiology affecting children under 5 years of age. There are no specific diagnostic tests, and thus, the diagnosis of the disease is primarily made on the basis of clinical criteria. Unusual presentations of Kawasaki disease have been variably reported from different parts of the world. However, presentation of the disease in the form of peripheral thromboembolism and florid non-coronary aneurysms has rarely been described This report describes the imaging findings in infantile atypical Kawasaki disease with aneurysms of multiple medium-sized arteries, including coronary arteries, emphasizing the detection of clinically silent aneurysms in the disease.

12.
J Clin Diagn Res ; 10(2): TC01-5, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27042553

RESUMO

INTRODUCTION: Clinical assessment of chronic liver disease is done by Modified Child Pugh's and Model for end-stage liver disease scoring system. Measurement of hepatic venous pressure gradient (HVPG) and Upper GI Endoscopy are considered the gold standards for measurement of portal hypertension in cirrhotics. There is a need for non-invasive evaluation of portal hypertension. Ultrasonography with colour and spectral Doppler evaluation may be an effective, rapid and inexpensive alternative. AIM: To evaluate hepatic venous waveform, damping index, splenoportal index in patients of cirrhosis on Colour Doppler ultrasound, also predict severity of portal hypertension and presence of oesophageal varices. MATERIALS AND METHODS: Thirty patients of chronic liver disease were included in the study. Ultrasound and colour Doppler was done to look hepatic venous waveform pattern, Damping Index (DI), and Splenoportal Index (SPI). Contrast-enhanced Computed Tomography scan (CT) was done if renal function tests were normal, else endoscopy when the renal function tests were deranged to look for oesophageal varices. RESULTS: Twenty two (73.3%) patients had monophasic waveform. Biphasic and triphasic waveforms were seen in 4 (13.3%) cases. Twenty two patients (73.3%) had monophasic waveforms and majority of them were in class C. This distribution of hepatic vein waveform was statistically significantly with the Child Pugh's class (p<0.05). Twenty patients (66.7%) had value of Damping index more than >0.6 where majority of patients (18) belonged to class C and 2 in class B. There was a positive correlation between Child Pugh's total score and Damping index (r=0.614; p<0.05). There was weak positive correlation between splenoportal index and Child Pugh's score (r=0.269; p=0.15). CONCLUSION: Change in triphasic to monophasic waveform and DI >0.6 suggests severe liver dysfunction and is associated with severe portal hypertension. Hepatic venous waveform pressure changes, DI and SPI have no value in predicting presence of oesophageal varices.

13.
Indian J Radiol Imaging ; 26(1): 44-51, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27081223

RESUMO

The application of magnetic resonance imaging (MRI) in pregnancy faced initial skepticism of physicians because of fetal safety concerns. The perceived fetal risk has been found to be unwarranted and of late, the modality has attained acceptability. Its role in diagnosing fetal anomalies is well recognized and following its safety certification in pregnancy, it is finding increasing utilization during pregnancy and puerperium. However, the use of MRI in maternal emergency obstetric conditions is relatively limited as it is still evolving. In early gestation, ectopic implantation is one of the major life-threatening conditions that are frequently encountered. Although ultrasound (USG) is the accepted mainstay modality, the diagnostic predicament persists in many cases. MRI has a role where USG is indeterminate, particularly in the extratubal ectopic pregnancy. Later in gestation, MRI can be a useful adjunct in placental disorders like previa, abruption, and adhesion. It is a good problem-solving tool in adnexal masses such as ovarian torsion and degenerated fibroid, which have a higher incidence during pregnancy. Catastrophic conditions like uterine rupture can also be preoperatively and timely diagnosed. MRI has a definite role to play in postpartum and post-abortion life-threatening conditions, e.g., retained products of conception, and gestational trophoblastic disease, especially when USG is inconclusive or inadequate.

14.
Indian J Radiol Imaging ; 25(4): 359-64, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26752721

RESUMO

Radiological imaging is extremely valuable as a diagnostic tool in the pediatric population, but it comes with a number of distinct challenges as compared to the imaging of adults. This is because of the following: It requires dedicated imaging protocols to acquire the images, there is need for sedation or general anesthesia for longer procedures such as MRI, specific training is required for the healthcare personnel involved, thorough knowledge and expertise should be applied for evaluating the images, and most importantly, it requires consideration for radiation exposure if ionizing radiation is being used. One of the challenges for clinical care personnel is to gain the child's trust and co-operation before and throughout the duration of an examination, which can prove to be difficult in children who may be ill and have pain. This is important to acquire quality images and prevent repeat examinations. Even with a quality examination, the accurate interpretation of images requires a thorough knowledge of the intricate and dynamic face of anatomy and specific pathological presentations in children. The increased radiation sensitivity of growing organs and children's longer expected life spans make them more susceptible to the harmful effects of radiation. Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. In order to prevent the harmful effects of ionizing radiation, As Low As Reasonably Achievable (ALARA) principle should be strictly followed. This article seeks to draw attention to various challenges of pediatric imaging and the ways to overcome them.

15.
Ann Indian Acad Neurol ; 18(1): 117-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25745329

RESUMO

Imaging alone cannot differentiate various isolated atypical lytic lesions involving the skull. Clinical and radiological correlation is mandatory in reaching to a diagnosis. Histopathology remains the gold standard. We describe few atypical cases presenting as isolated lytic lesions of skull with characteristic imaging findings and a brief clinical approach to reach towards the diagnosis.

16.
Indian J Radiol Imaging ; 25(2): 167-72, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25969640

RESUMO

PURPOSE: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA) measurements in the Indian population. MATERIALS AND METHODS: A retrospective review of multi-detector CT (MDCT) cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL) and the shortest distance between the vertebral artery and the medial (M), lateral (L), anterior (A), and posterior (P) borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h) was also analyzed. STATISTICAL ANALYSIS: The means and their standard deviations (SD) were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. RESULTS: The largest vertebral artery diameter (AL) was at level C7 on the right side (3.5 ± 0.8) and at the level of C5 on the left side (3.7 ± 0.4). Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P) at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. CONCLUSION: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7.

17.
Indian J Med Paediatr Oncol ; 35(2): 143-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25197176

RESUMO

Gastrointestinal stromal tumors (GISTs) were first described by Clark and Mazur in 1983 for smooth muscle neoplasms of the gastrointestinal tract differentiating them from leiomyoma, leiomyosarcomas and neurogenic tumors. GISTs can arise from the bowel, peritoneum, omentum or retroperitoneum. This article reviews the computed tomography imaging features of primary GISTs, response to treatment and highlights data on predicting the outcome to chemotherapeutic drugs on imaging.

18.
Indian J Radiol Imaging ; 24(2): 192-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25024532

RESUMO

Melorheostosis is an uncommon mesenchymal dysplasia that rarely affects the axial skeleton. We describe two atypical cases of melorheostosis with classical imaging findings - the first one involving the cervico-dorsal spine with encroachment of left vertebral artery canal causing attenuation of the left vertebral artery and the second one of mixed sclerosing bony dysplasia (monomelic involvement coexisting with osteopoikilosis).

19.
Avicenna J Med ; 3(4): 103-5, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24327969

RESUMO

Abdominal cocoon is an acquired benign condition in which there is encapsulation of bowel loops by a fibrous membrane. Pre-operative clinical diagnosis is usually difficult. Imaging plays a critical role in timely and accurate diagnosis. We present a brief discussion on this topic with relevant imaging findings.

20.
Indian J Radiol Imaging ; 23(3): 223-33, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24347852

RESUMO

PURPOSE: To evaluate the spectrum of celiac axis, common hepatic artery (CHA), right, left, middle hepatic artery and gastroduodenal artery variations by using spiral computed tomography (CT). MATERIALS AND METHODS: A retrospective review of Multidetector CT (MDCT) abdominal angiography scans was performed in patients sent for various liver and other abdominal pathologies between January 2012 and February 2013. A total of 600 patients were evaluated. Definitions of CHA, ambiguous celiac axis, course and division patterns of CHA, replaced hepatic artery, accessory hepatic artery and middle hepatic artery were used as proposed by Song et al., Covey et al., and Wang et al. The pattern of the aortic origin of branches of celiac axis, common hepatic artery and its branches was analyzed. RESULTS: Six types of celiac axis anatomic variations were identified in our study. A total of 546 of the 600 patients had a normal celiac axis anatomy. Anatomic variations were seen in 5.5% of patients. Ambiguous anatomy was seen in 3.5% of the patients. CHA originated from celiac axis in 95.83% of the patients. Variations in anatomic origin of CHA were seen in 8 patients. Ambiguous dual pathway was seen in 4 patients. Normal Sp-preportal course of CHA was identified in 97.78% of cases, Sp-retroportal course in 7 patients, Tp-preportal course in 2, Tp-retroportal in 1, Ip-preportal in 1 and through Ligamentum venosum in 2 patients. Normal origin of RHA from HAP was seen in 79.6% patients. Replaced origin of RHA was seen in 15.16% cases and Accessory origin of RHA was seen in 5.16% cases. LHA originated from HAP in 81.5% patients. Replaced LHA origin was seen in 10.8% cases and Accessory LHA origin seen in 7.6% cases. MHA originated from RHA in 41.3% patients, LHA in 27.83% and from CHA in 4.5% cases. Origin of MHA could not be defined in 26.3% of patients. GDA originated from CHA in 97.6% of patients, from celiac axis in 1.6%, from RHA in 0.33% in patients. Trifurcation of CHA was seen in 7.16% and quadrifurcation of CHA in 2.16%. CONCLUSION: CT Angiography is a safe and highly sensitive and accurate modality for evaluation of arterial anatomy and its variants.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa