Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Inherit Metab Dis ; 44(5): 1099-1112, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34286869

RESUMO

Wilson disease (WD) is a rare genetic condition that results from a build-up of copper in the body. It requires life-long treatment and is mainly characterized by hepatic and neurological features. Copper accumulation has been reported to be related to the occurrence of heart disease, although little is known regarding this association. We have conducted a systematic review of the literature to document the association between WD and cardiac involvement. Thirty-two articles were retained. We also described three cases of sudden death. Cardiac manifestations in WD include cardiomyopathy (mainly left ventricular (LV) remodeling, hypertrophy, and LV diastolic dysfunction, and less frequently LV systolic dysfunction), increased levels of troponin, and/or brain natriuretic peptide, electrocardiogram (ECG) abnormalities, and rhythm or conduction abnormalities, which can be life-threatening. Dysautonomia has also been reported. The mechanism of cardiac damage in WD has not been elucidated. It may be the result of copper accumulation in the heart, and/or it could be due to a toxic effect of copper, resulting in the release of free oxygen radicals. Patients with signs and/or symptoms of cardiac involvement or who have cardiovascular risk factors should be examined by a cardiologist in addition to being assessed by their interdisciplinary treating team. Furthermore, ECG, cardiac biomarkers, echocardiography, and 24-hours or more of Holter monitoring at the diagnosis and/or during the follow-up of patients with WD need to be evaluated. Cardiac magnetic resonance imaging, although not always available, could also be a useful diagnostic tool, allowing assessment of the risk of ventricular arrhythmias and further guidance of the cardiac workup.


Assuntos
Arritmias Cardíacas/etiologia , Cardiomiopatias/etiologia , Morte Súbita Cardíaca/etiologia , Degeneração Hepatolenticular/complicações , Disautonomias Primárias/etiologia , Adulto , Arritmias Cardíacas/fisiopatologia , Autopsia , Cardiomiopatias/fisiopatologia , Cobre/sangue , Cobre/metabolismo , Ecocardiografia , Eletrocardiografia Ambulatorial , Feminino , Degeneração Hepatolenticular/genética , Degeneração Hepatolenticular/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Disautonomias Primárias/fisiopatologia
2.
Europace ; 23(1): 73-81, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33257972

RESUMO

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
3.
Cardiol Res Pract ; 2020: 4348598, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32963823

RESUMO

BACKGROUND: COVID-19 interacts at multiple levels with the cardiovascular system. The prognosis of COVID-19 infection is known to be worse for patients with underlying cardiovascular diseases. Furthermore, the virus is responsible for many cardiovascular complications. Myocardial injury may affect up to 20% of the critically ill patients. However, echocardiography's impact on the management of patients affected by COVID-19 remains unknown. OBJECTIVES: To explore echocardiography's impact on the management of COVID-19 patients. METHODS: This study was conducted from March 24th to April 14th, 2020, in a single center at Adolphe de Rothschild Foundation Hospital, Paris, France. All consecutive inpatients with laboratory and/or CT COVID-19 diagnosis were included in this study. Patients' characteristics (clinical, biological, and imaging) and treatment change induced by echocardiography were collected and analyzed. Patients with and without treatment change induced by echocardiography were compared. RESULTS: A total of 56 echocardiographies in 42 patients with highly suspected or confirmed COVID-19 were included in the final analyses. The median age was 66 (IQR 60.5-74). Echocardiography induced a treatment change in 9 cases (16%). The analyzed clinical data were not associated with any treatment change induced by echocardiography. D-dimer and Troponin levels were the only biological predictors of the induced treatment change. On echocardiography, higher systolic pulmonary arterial pressure and documented cardiac thrombi were associated with treatment changes in these patients. CONCLUSIONS: Echocardiography may be useful for the management of selected COVID-19 patients, especially those with elevated D-Dimer and Troponin levels, in up to 16% of patients.

4.
Cardiol Res Pract ; 2020: 8076582, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32190384

RESUMO

BACKGROUND: Left ventricular ejection fraction (LVEF) and end diastolic volume (EDV) are measured using Simpson's biplane (SB), 3-dimensional method (3DE), and speckle tracking (STE). Comparisons between methods in routine practice are limited. Our purpose was to compare and to determine the correlations between these three methods in clinical setting. METHODS: LVEF and EDV were measured by three methods in 474 consecutive patients and compared using multiple Bland-Altman (BA) plots. The correlations (R) between methods were calculated. RESULTS: Median (IQR) LVEF_SB, LVEF_STE, and LVEF_3DE were 63.0% (60-69)%, 61% (57-65)%, and 62% (57-68)%. Median (IQR) EDV_SB, EDV_STE, and EDV_3DE were 85 ml (71-106) ml, 82 ml (69-100) ml, and 73 ml (59-89) ml. R between LVEF_SB and LVEF_3DE was 0.65 when echogenicity was good and 0.43 when poor. R for EDV_SB and EDV_3DE was 0.75 when echogenicity was good and 0.45 when poor. On BA analysis, biases were acceptable (<3.5% for LVEF) but limits of agreement (LOA) were large: 95% of the differences were between -15.4% and +18.8% for LVEF as evaluated by SB in comparison with 3DE, with a bias of 1.7%. In the comparison EDV_SB and EDV_3DE, the bias was 14 ml and the LOA were between -24 ml and +53 ml. On linear regressions, LVEF_3DE = 17.92 + 0.69 LVEF_SB and EDV_3DE = 18.94 + 0.63 EDV_SB. CONCLUSIONS: The three methods were feasible and led to acceptable bias but large LOA. Although these methods are not interchangeable, our results allow 3DE value prediction from SB, the most commonly used method.

5.
Eur J Heart Fail ; 22(8): 1357-1365, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32353213

RESUMO

Low blood pressure is common in patients with heart failure and reduced ejection fraction (HFrEF). While spontaneous hypotension predicts risk in HFrEF, there is only limited evidence regarding the relationship between hypotension observed during heart failure (HF) drug titration and outcome. Nevertheless, hypotension (especially orthostatic hypotension) is an important factor limiting the titration of HFrEF treatments in routine practice. In patients with signs of shock and/or severe congestion, hospitalization is advised. However, in the very frequent cases of non-severe and asymptomatic hypotension observed while taking drugs with a class I indication in HFrEF, European and US guidelines recommend maintaining the same drug dosage. In instances of symptomatic or severe persistent hypotension (systolic blood pressure < 90 mmHg), it is recommended to first decrease blood pressure reducing drugs not indicated in HFrEF as well as the loop diuretic dose in the absence of associated signs of congestion. Unless the management of hypotension appears urgent, a HF specialist should then be sought rather than stopping or decreasing drugs with a class I indication in HFrEF. If symptoms or severe hypotension persist, no recommendations exist. Our HF group reviewed available evidence and proposes certain steps to follow in such situations in order to improve the pharmacological management of these patients.


Assuntos
Insuficiência Cardíaca , Hipotensão , Disfunção Ventricular Esquerda , Antagonistas de Receptores de Angiotensina , Pressão Sanguínea , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Humanos , Hipotensão/tratamento farmacológico , Hipotensão/epidemiologia , Inibidores de Simportadores de Cloreto de Sódio e Potássio/uso terapêutico , Volume Sistólico
7.
Heart Rhythm ; 11(8): 1367-76, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24727582

RESUMO

BACKGROUND: Pacemaker (PM) interrogation requires correct manufacturer identification. However, an unidentified PM is a frequent occurrence, requiring time-consuming steps to identify the device. OBJECTIVE: The purpose of this study was to develop and validate a novel algorithm for PM manufacturer identification, using the ECG response to magnet application. METHODS: Data on the magnet responses of all recent PM models (≤15 years) from the 5 major manufacturers were collected. An algorithm based on the ECG response to magnet application to identify the PM manufacturer was subsequently developed. Patients undergoing ECG during magnet application in various clinical situations were prospectively recruited in 7 centers. The algorithm was applied in the analysis of every ECG by a cardiologist blinded to PM information. A second blinded cardiologist analyzed a sample of randomly selected ECGs in order to assess the reproducibility of the results. RESULTS: A total of 250 ECGs were analyzed during magnet application. The algorithm led to the correct single manufacturer choice in 242 ECGs (96.8%), whereas 7 (2.8%) could only be narrowed to either 1 of 2 manufacturer possibilities. Only 2 (0.4%) incorrect manufacturer identifications occurred. The algorithm identified Medtronic and Sorin Group PMs with 100% sensitivity and specificity, Biotronik PMs with 100% sensitivity and 99.5% specificity, and St. Jude and Boston Scientific PMs with 92% sensitivity and 100% specificity. The results were reproducible between the 2 blinded cardiologists with 92% concordant findings. CONCLUSION: Unknown PM manufacturers can be accurately identified by analyzing the ECG magnet response using this newly developed algorithm.


Assuntos
Algoritmos , Arritmias Cardíacas/terapia , Eletrocardiografia/instrumentação , Imãs , Marca-Passo Artificial , Arritmias Cardíacas/fisiopatologia , Seguimentos , Humanos , Curva ROC , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa