1.
Laryngoscope ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38095278

RESUMO

OBJECTIVE: To evaluate the safety and efficacy of endoscopic treatment of subglottic stenosis with flexible bronchoscopy via laryngeal mask airway (LMA) approach. METHODS: The records of all patients who underwent endoscopic surgery for subglottic stenosis (SGS) from November 2019 to January 2023 at an academic medical center were reviewed with attention to demographics, patient comorbidities, airway stenosis characteristics, operative time details, surgical complications, and post-operative course. All patients, >18 years old, with one or more surgeries for SGS using (LMA) for intraoperative airway management were included. Surgeries with suspension microlaryngoscopy were excluded. Patients with glottic stenosis or tracheotomy were excluded. RESULTS: Thirty-five patients underwent 52 procedures meeting inclusion criteria. Mean age was 55 years (range 31-78, SD 13.3) and 33 patients (94%) were female. Mean BMI was 30.9 (range 18.4-60.5, SD 8.8). The most common etiology of stenosis was intubation injury in 17 patients (49%), followed by idiopathic in 13 patients (37%). Cotton-Meyer grade 3 (71-99% narrowing) was seen in 25 patients (71%). Mean anesthesia and surgical operative times were 75.9 min (SD 13.5 min) and 39.7 min (SD 11.0 min), respectively. Mean SpO2 nadir was 94.5% (SD 6.3%). No patients required intraoperative change to rigid laryngoscopy, intubation, or tracheotomy. There were no post-operative complications. Mean surgery-free interval was 12.2 months (SD 6.3). CONCLUSION: Endoscopic treatment of subglottic stenosis with flexible bronchoscopy and spontaneous ventilation via LMA approach is a safe and effective option, especially in patients with limitations for rigid laryngoscopy and elevated BMI. LEVEL OF EVIDENCE: Level Four (case series) Laryngoscope, 2023.

2.
Cardiovasc Intervent Radiol ; 46(2): 209-219, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36416916

RESUMO

PURPOSE: To evaluate the correlation of neutrophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), aspartate aminotransferase-to-lymphocyte ratio (ALRI), systemic inflammation index (SII), and lymphocyte count to oncologic outcomes in metastatic colorectal cancer (mCRC) patients undergoing transarterial radioembolization (TARE). MATERIALS AND METHODS: All patients undergoing TARE for mCRC were retrospectively reviewed at a single academic institution. A receiver operating characteristics (ROC) curve analysis was performed using a landmark survival point of 12 months, with an area under the curve (AUC) calculated. A cutoff point was determined by Youden's index and used to separate patients for OS and PFS analysis. Cox proportional-hazards models which included pertinent clinical factors were also created to evaluate PFS and OS. RESULTS: In total, 41 patients who underwent 66 TARE treatments were included. A correlation was seen between post-treatment ALRI < 45 (HR: 0.38 (95%CI: 0.17-0.86), p = 0.02) and PFS. Patients with a pretreatment ALRI score < 20 had a significantly longer OS (HR: 0.49 (95%CI: 0.19-0.88), p = 0.02) as did those with a post-treatment lymphocyte count > 1.1 109/L (HR: 0.27 (95%CI: 0.11-0.68), p = 0.005). In multivariate analysis of PFS, post-treatment lymphocyte count (HR: 8.46 (95%CI: 1.14-62.89), p = 0.044) was the only significantly associated inflammatory marker and presence of extrahepatic disease (HR:8.46 (95%CI: 1.14-62.89, p = 0.044) also correlated. Multivariate analysis of OS showed that pretreatment PLR (HR:1.01 (95%CI:1.-1.03), p = 0.02) and post-treatment NLR (HR:0.33 (95%CI:0.14-0.76), p = 0.009), PLR (HR:0.98 (95%CI:0.97-1), p = 0.046), SII (HR:1.04 (95%CI:1.01-1.08), p = 0.014), and lymphocyte count (HR:0.07 (95%CI:0.01-0.16), p = 0.003) were significantly associated. CONCLUSION: Inflammatory markers may be associated with OS and PFS in mCRC patients undergoing TARE.


Assuntos
Neoplasias do Colo , Neoplasias Retais , Humanos , Estudos Retrospectivos , Prognóstico , Linfócitos , Contagem de Linfócitos , Neutrófilos
3.
Diagn Interv Imaging ; 104(4): 185-191, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36604211

RESUMO

PURPOSE: To determine the accuracy and clinical significance of planar scintigraphy lung shunt fraction (PLSF) and single-photon emission computerized tomography (SPECT) computed tomography (CT) lung shunt fraction (SLSF) before Y-90 transarterial radioembolization. MATERIALS AND METHODS: Seventy patients (46 men, 24 women; mean age, 64 ± 9.5 [SD] years) who underwent 83 treatments with Y-90 transarterial radioembolization for primary or secondary malignancies of the liver with a PLSF ≥ 7.5% were retrospectively evaluated. The patients mapping technetium 99 m (Tc-99 m) macroaggregated albumin (MAA) PLSF and SLSF were calculated and compared to the post Y-90 delivery SLSF. A model using modern dose thresholds was created to identify patients who would require dose reduction due to a lung dose ≥ 30 Gy, with patients who required >50% dose reduction considered to be delivery cancelations. RESULTS: A significant difference was found between mean PLSF (14.7 ± 11.6 [SD]%; range: 7.5-84.1%) and mean SLSF (8.7 ± 8.5 [SD]%; range: 1.7-73.5) (P < 0.001). The mean realized LSF (7.1 ± 3 [SD]%; range:1.5-17.6) was significantly less than the PLSF (P <0.001) but not the SLSF (P = 0.07). PLSF significantly overestimated the realized LSF by more than the SLSF (8.5 ± 5.3 [SD] % [range: -0.1-21.7] vs. 0.8 ± 3.6 [SD] % [range: -5-13.2], respectively) (P < 0.001). Based on the clinical significance model, 20 patients (20/83, 24.1%) would have required dose reduction or cancelation when using PLSF but would not require even a dose reduction when using the SLSF. Significantly more deliveries would have been be canceled if PLSF was used as compared to SLSF (22/83 [26.5%] vs. 6/83 [7.2%], respectively) (P < 0.001). CONCLUSION: SLSF is significantly more accurate at predicting realized LSF than PLSF and this difference is of clinical significance in a number of patients with a PLSF ≥ 7.5%.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Radioisótopos de Ítrio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Estudos Retrospectivos , Relevância Clínica , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Pulmão , Embolização Terapêutica/métodos , Microesferas
4.
Med Eng Phys ; 84: 60-67, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32977923

RESUMO

Titanium implants are widely used in dental and orthopedic surgeries. Osseointegration phenomena lead to direct contact between bone tissue and the implant surface. The quality of the bone-implant interface (BII), resulting from the properties of newly formed bone, determines the implant stability. This study investigates the BII properties using a dedicated in vivo implant model consisting of a coin-shaped Ti-6Al-4V implant inserted in a rabbit femur for 10 weeks. A gap created below the implant was filled with newly formed bone tissue after healing. The properties of mature and newly formed bone tissues were compared using: i) Raman spectroscopy to assess the nanoscale compositional bone properties and ii) nanoindentation to quantify microscale elastic properties in site-matched regions. The mineral-to-matrix ratio, crystallinity (mineral size and lattice order), and the collagen cross-link ratio were significantly lower in newly formed bone tissue (e.g., a mineral-to-matrix ratio of 9.3 ± 0.5 for proline 853 cm-1) compared to mature bone (15.6 ± 1). Nanoindentation measurements gave Young's modulus of 12.8 ± 1.8 GPa for newly formed bone and 15.7 ± 2.3 GPa for mature bone. This multimodal and multiscale approach leads to a better understanding of osseointegration phenomena.


Assuntos
Interface Osso-Implante , Implantes Dentários , Animais , Osseointegração , Coelhos , Análise Espectral Raman , Propriedades de Superfície , Titânio
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa