Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 144(10)2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35274123

RESUMO

Fiber structures and pathological features, e.g., inflammation and glycosaminoglycan (GAG) deposition, are the primary determinants of aortic mechanical properties which are associated with the development of an aneurysm. This study is designed to quantify the association of tissue ultimate strength and extensibility with the structural percentage of different components, in particular, GAG, and local fiber orientation. Thoracic aortic aneurysm (TAA) tissues from eight patients were collected. Ninety-six tissue strips of thickened intima, media, and adventitia were prepared for uni-extension tests and histopathological examination. Area ratios of collagen, elastin, macrophage and GAG, and collagen fiber dispersion were quantified. Collagen, elastin, and GAG were layer-dependent and the inflammatory burden in all layers was low. The local GAG ratio was negatively associated with the collagen ratio (r2 = 0.173, p < 0.05), but positively with elastin (r2 = 0.037, p < 0.05). Higher GAG deposition resulted in larger local collagen fiber dispersion in the media and adventitia, but not in the intima. The ultimate stretch in both axial and circumferential directions was exclusively associated with elastin ratio (axial: r2 = 0.186, p = 0.04; circumferential: r2 = 0.175, p = 0.04). Multivariate analysis showed that collagen and GAG contents were both associated with ultimate strength in the circumferential direction, but not with the axial direction (collagen: slope = 27.3, GAG: slope = -18.4, r2 = 0.438, p = 0.002). GAG may play important roles in TAA material strength. Their deposition was found to be associated positively with the local collagen fiber dispersion and negatively with ultimate strength in the circumferential direction.


Assuntos
Aneurisma da Aorta Torácica , Elastina , Fenômenos Biomecânicos , Colágeno , Glicosaminoglicanos , Humanos , Macrófagos
2.
Atherosclerosis ; 320: 38-46, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33524908

RESUMO

BACKGROUND AND AIMS: Artery is subject to wall shear stress (WSS) and vessel structural stress (VSS) simultaneously. This study is designed to explore the role of VSS in development of atherosclerosis. METHODS: Silastic collars were deployed on the carotid to create two constrictions on 13 rabbits for a distinct mechanical environment at the constriction. MRI was performed to visualize arteries' configuration. Animals with high fat (n = 9; Model-group) and normal diet (n = 4; Control-group) were sacrificed after 16 weeks. 3D fluid-structure interaction analysis was performed to quantify WSS and VSS simultaneously. RESULTS: Twenty plaques were found in Model-group and 3 in Control-group. In Model-group, 8 plaques located proximally to the first constriction (Region-1, close to the heart) and 7 distally to the second (Region-2, close to the head) and 5 plaques were found on the contralateral side of 3 rabbits. Plaques at Region-1 tended to be bigger than those at Region-2 and the macrophage density at these locations was comparable. Minimum time-averaged WSS (TAWSS) in Region-1 was significantly higher than that in Region-2, and both maximum oscillatory shear index (OSI) and particle relative residence time (RRT) were significantly lower. Peak and mean VSS in Region-1 were significantly higher than those in Region-2. Correlation analyses indicated that low TAWSS, high OSI and RRT were only associated with plaque in Region-2, while lesions in Region-1 were only associated with high VSS. Moreover, only VSS was associated with wall thickness of plaque-free regions in both regions. CONCLUSIONS: VSS might contribute to the initialization and development of atherosclerosis solely or in combination with WSS.


Assuntos
Aterosclerose , Placa Aterosclerótica , Animais , Artérias Carótidas/diagnóstico por imagem , Constrição Patológica , Hemodinâmica , Modelos Cardiovasculares , Coelhos , Resistência ao Cisalhamento , Estresse Mecânico
3.
IEEE Trans Biomed Eng ; 66(8): 2269-2278, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30703001

RESUMO

OBJECTIVE: Mechanical properties of healthy, aneurysmal, and atherosclerotic arterial tissues are essential for assessing the risk of lesion development and rupture. Strain energy density function (SEDF) has been widely used to describe these properties, where material constants of the SEDF are traditionally determined using the ordinary least square (OLS) method. However, the material constants derived using OLS are usually dependent on initial guesses. METHODS: To avoid such dependencies, Bayesian inference-based estimation was used to fit experimental stress-stretch curves of 312 tissue strips from 8 normal aortas, 19 aortic aneurysms, and 21 carotid atherosclerotic plaques to determine the constants, C1, D1, and D2 of the modified Mooney-Rivlin SEDF. RESULTS: Compared with OLS, material constants varied much less with prior in the Bayesian inference-based estimation. Moreover, fitted material constants differed amongst distinct tissue types. Atherosclerotic tissues associated with the biggest D2, an indicator of the rate of increase in stress during stretching, followed by aneurysmal tissues and those from normal aortas. Histological analyses showed that C1 and D2 were associated with elastin content and details of the collagen configuration, specifically, waviness and dispersion, in the structure. CONCLUSION: Bayesian inference-based estimation robustly determines material constants in the modified Mooney-Rivlin SEDF and these constants can reflect the inherent physiological and pathological features of the tissue structure. SIGNIFICANCE: This study suggested a robust procedure to determine the material constants in SEDF and demonstrated that the obtained constants can be used to characterize tissues from different types of lesions, while associating with their inherent microstructures.


Assuntos
Aorta , Aneurisma Aórtico/fisiopatologia , Aterosclerose/fisiopatologia , Modelos Cardiovasculares , Idoso , Aorta/fisiologia , Aorta/fisiopatologia , Teorema de Bayes , Fenômenos Biomecânicos/fisiologia , Artérias Carótidas/fisiologia , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/fisiopatologia , Feminino , Humanos , Análise dos Mínimos Quadrados , Masculino , Teste de Materiais , Pessoa de Meia-Idade
4.
J Biomech ; 60: 188-196, 2017 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-28712543

RESUMO

BACKGROUND: Multiple overlapping uncovered stents (MOUS) system has shown potentials in managing complex aortic aneurysms with side branches involvement. It promotes the development of thrombus by modulating local flow pattern that reduces the wall tension, while maintaining patency of side branches. However the modulation of local hemodynamic parameters depends on various factors that have not been assessed comprehensively. METHODS: Aneurysm 3D geometry was reconstructed based on CT images. One-way fluid-structure interaction analysis was performed to quantify structural stress concentration in the wall, and changes of blood velocity, wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT) and pressure in the sac due to the stent deployment. RESULTS: High structural stress concentration due to stent deployment was found in the landing zone and it increased linearly with the number of stents deployed. The wall tension in the sac was unaffected by the stent deployment. Stress within the wall was insensitive to the different overlapping pattern. After one stent was deployed, the mean flow velocity in the sac reduced by 36.4%. The deployment of the 2nd stent further reduced the mean sac velocity by 10%. WSS decreased while both OSI and RRT increased after stent deployment, however pressure in the sac remained nearly unchanged. Except for the cases with complete stents struts alignment, different overlapping pattern had little effect on flow parameters. CONCLUSIONS: Mechanical parameters modulated by the MOUS are insensitive to different overlapping pattern suggesting that endovascular procedure can be performed with less attention to the overlapping pattern.


Assuntos
Aneurisma da Aorta Torácica/fisiopatologia , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/terapia , Procedimentos Endovasculares , Hemodinâmica , Humanos , Masculino , Estresse Mecânico , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa