Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Catheter Cardiovasc Interv ; 90(7): 1135-1144, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28799706

RESUMO

OBJECTIVES: This study aimed to report our national experience with transcatheter patent ductus arteriosus (PDA) occlusion in infants weighing <6 kg. BACKGROUND: The technique of transcatheter PDA closure has evolved in the past two decades and is increasingly used in smaller patients but data on safety and efficacy are limited. METHODS: Patients weighing < 6 kg in whom transcatheter PDA occlusion was attempted in 13 tertiary paediatric cardiology units in the United Kingdom and Ireland were retrospectively analyzed to review the outcome and complications. RESULTS: A total of 408 patients underwent attempted transcatheter PDA closure between January 2004 and December 2014. The mean weight at catheterization was 4.9 ± 1.0 kg and mean age was 5.7 ± 3.0 months. Successful device implantation was achieved in 374 (92%) patients without major complication and of these, complete occlusion was achieved in 356 (95%) patients at last available follow-up. Device embolization occurred in 20 cases (5%). The incidence of device related obstruction to the left pulmonary artery or aorta and access related peripheral vascular injury were low. There were no deaths related to the procedure. CONCLUSIONS: Transcatheter closure of PDA can be accomplished in selected infants weighing <6 kg despite the manufacturer's recommended weight limit of 6 kg for most ductal occluders. The embolization rate is higher than previously reported in larger patients. Retrievability of the occluder and duct morphology needs careful consideration before deciding whether surgical ligation or transcatheter therapy is the better treatment option.


Assuntos
Peso Corporal , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/terapia , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Tomada de Decisão Clínica , Permeabilidade do Canal Arterial/diagnóstico por imagem , Humanos , Lactente , Irlanda , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Reino Unido
2.
Cardiol Young ; 23(5): 692-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23089055

RESUMO

The presence of an atrial septal defect in pulmonary hypertension has benefits and detractions. Even in idiopathic pulmonary arterial hypertension, a significant left-to-right shunt at atrial level may increase the pulmonary arterial pressure and exacerbate the disease. However, it is well recognised that the presence of an atrial communication may be protective in subgroups with severe disease, allowing maintenance of cardiac output during times of increased pulmonary resistance. In the present paper, we present the case of a young boy with significant idiopathic pulmonary arterial hypertension and an atrial septal defect. We report our technique of septal occlusion using a device to decrease left-to-right shunting with concomitant stent insertion in that device to maintain the potential for right-to-left shunting during times of high pulmonary arterial pressure.


Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Hipertensão Pulmonar/cirurgia , Dispositivo para Oclusão Septal , Stents , Cateterismo Cardíaco/instrumentação , Criança , Hipertensão Pulmonar Primária Familiar , Comunicação Interatrial/complicações , Humanos , Hipertensão Pulmonar/complicações , Masculino , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 73(4): 576-80, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19235246

RESUMO

Despite the wide variety of occlusion devices available for closing the patent ductus arteriosus; some defects with unusual morphology still remain a challenge. The drive for increasingly user friendly and lower caliber delivery systems is also ongoing. The new amplatzer ductal occluder II may prove to be a useful additional tool in these circumstances. We describe our initial experiences with this new device in three patients with long tubular (Type C) ducts.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Desenho de Equipamento , Humanos , Lactente , Radiografia Intervencionista , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 72(1): 65-71, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18412235

RESUMO

OBJECTIVES: We describe our complete experience with covered stent implantation for aortic coarctation including short- to medium-term outcomes. BACKGROUND: Coarctation of the aorta is a heterogeneous disease process with multiple associated complications both with and without treatment. Covered stents have evolved to provide greater support to the aortic wall and a varied approach with choice of stent tailored to the anatomy of the patient is required. METHODS: We retrospectively analyzed consecutive patient data from two congenital heart centers from March 2003 to October 2007. RESULTS: We implanted 38 covered stents in 37 patients (20 female) of which three were self-expanding stents. Median age was 29.6 years (9-65) with median weight of 71.5 kg (35-95). The indications for stent placement were native coarctation (n = 13); recurrent coarctation following surgical treatment (n = 11); aneurysm associated with previous coarctation surgery (n = 7); aorto-bronchial fistula leading to acute hemoptysis (n = 2); stent fracture (n = 1); associated arterial duct (n = 2). One patient had a combination of acquired coarctation and false aneurysm. The median screening time was 10 min (3-22). The median systolic gradient of 26 mm Hg (10-60) was reduced to 4 mm Hg (0-20) postprocedure (P < 0.001). There were no deaths on median follow up of 11.5 months (1-56). One patient developed aortic rupture during the procedure and required emergency surgery. CONCLUSION: Covered stent implantation for treatment of aortic coarctation is safe and highly effective in selected patients. Self-expanding stent grafts may be preferable to balloon expandable stents when there is aneurysm formation in the setting of aortopathy.


Assuntos
Angioplastia Coronária com Balão , Aneurisma Aórtico/complicações , Coartação Aórtica/complicações , Coartação Aórtica/terapia , Materiais Revestidos Biocompatíveis , Stents , Adolescente , Adulto , Idoso , Aneurisma Aórtico/terapia , Criança , Estudos de Coortes , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres , Politetrafluoretileno , Estudos Retrospectivos , Resultado do Tratamento
5.
J Am Coll Cardiol ; 67(24): 2858-70, 2016 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-27311525

RESUMO

BACKGROUND: There are several options available for aortic valve replacement (AVR), with few comparative reports in the literature. The optimal choice for AVR in each age group is not clear. OBJECTIVES: The study sought to report and compare outcomes after AVR in the young using data from a national database. METHODS: AVR procedures were compared after advanced matching, both in pairs and in a 3-way manner, using a Bayesian dynamic survival model. RESULTS: A total of 1,501 patients who underwent AVR in the United Kingdom between 2000 and 2012 were included. Of these, 47.8% had a Ross procedure, 37.8% a mechanical AVR, 10.9% a bioprosthesis AVR, and 3.5% a homograft AVR, with Ross patients being significantly younger when compared to the other groups. Overall survival at 12 years was 94.6%. In children, the Ross procedure had a 12.7% higher event-free probability (death or any reintervention) at 10 years when compared to mechanical AVR (p = 0.05). We also compared all procedures except the homograft in a matched population of young adults, where the bioprosthesis had the lowest event-free probability of 78.8%, followed by comparable results in mechanical AVR and Ross, with 86.3% and 89.6%, respectively. Younger age was associated with mortality and pulmonary reintervention in the Ross group and with aortic reintervention in the mechanical AVR. Of all 3 options, only the patients undergoing the Ross procedure approached the survival of the general population. CONCLUSIONS: AVR in the young achieves good results, with the Ross being overall better suited for this age group, especially in children. Although freedom from aortic valve reintervention is superior after the Ross procedure, the need for homograft reinterventions is an issue to take into account. All methods have advantages and limitations, with reinterventions being an issue in the long term for all, more crucially in smaller children.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Adolescente , Adulto , Fatores Etários , Bioprótese , Criança , Pré-Escolar , Feminino , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Humanos , Lactente , Recém-Nascido , Masculino , Modelos Estatísticos , Reoperação/estatística & dados numéricos , Reino Unido/epidemiologia , Adulto Jovem
7.
Heart ; 96(15): 1212-6, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19744966

RESUMO

BACKGROUND: Stenting for aortic coarctation is known to be effective in the medium term. Aneurysm formation following stent implantation is a recognised complication. However, data regarding aortic wall injury and stent integrity following stent placement are sparse. OBJECTIVES: We report comprehensive clinical, echocardiographic and prospective CT follow-up data following stenting for aortic coarctation from a single centre. Methods Full data analysis of all patients undergoing balloon expandable stent implantation and follow-up procedures in a single tertiary congenital cardiac unit. RESULTS: Between October 2002 and April 2008, we performed 102 coarctation stent procedures on 88 patients. Median age was 20.6 years (range 8.5-65) and median weight 65 kg (range 34-101). 94 stents (26 covered) were implanted. 12 procedures were re-dilatations. Stenting resulted in a reduction of the gradient across the site of coarctation, from a median of 20 mm Hg to 4 mm Hg. There were no procedure-related deaths. Four patients had immediate complications (one requiring emergency surgery). During median follow-up of 34.5 months (range 4.2-72.8), two patients had late complications requiring additional stent procedures. Follow-up CT data are available in 84 patients with MRI in one patient (96.5%). Only one patient developed a procedure-related aortic aneurysm. All stent fractures (n=7) occurred with a single stent design. CONCLUSIONS: Stenting for aortic coarctation and re-coarctation is effective with low immediate complication rates. CT is useful in the longer term for assessment of stent integrity and post-procedural aneurysm formation. Overall incidence of post-procedural aneurysm is rare and stent fractures were not seen with newer generation stents.


Assuntos
Aneurisma Aórtico/etiologia , Coartação Aórtica/terapia , Cateterismo/métodos , Stents , Doença Aguda , Adolescente , Adulto , Idoso , Aorta/lesões , Aneurisma Aórtico/diagnóstico por imagem , Cateterismo/efeitos adversos , Criança , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Stents/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
8.
Catheter Cardiovasc Interv ; 69(1): 33-9, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17139627

RESUMO

We describe the use of a new vascular occlusion device to embolize vessels whose flow is detrimental to cardiac function in a variety of clinical situations in both adults and children with congenital cardiac disease. Our series includes four cases in which we have successfully occluded large venous vessels, to produce a beneficial effect on oxygen saturations and cardiac function. There were no adverse events because of the devices in our series, which provides evidence that the Amplatzer vascular plug is a safe and effective method of embolizing large venous vessels.


Assuntos
Oclusão com Balão/instrumentação , Circulação Colateral , Cardiopatias Congênitas/terapia , Adolescente , Adulto , Pré-Escolar , Angiografia Coronária , Feminino , Humanos , Masculino , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 68(6): 929-35, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17086539

RESUMO

OBJECTIVES: To assess the feasibility and results of trans-axillary approach for balloon aortic valvoplasty (BAV) in early infancy. BACKGROUND: Severe aortic valve stenosis (SAVS) is rare but serious condition in infancy, which may be promptly treated either by surgical aortic valvotomy or BAV. BAV is usually performed via the femoral artery route, which is associated with significant vascular complications and long procedure times. METHODS: BAV via the trans-axillary approach was performed on twenty-seven sequential infants with SAVS presenting to a single tertiary referral center over an 11-year period. Maximum inflated balloon size was less than or equal to the aortic valve diameter. RESULTS: Twenty-seven infants aged 1-77 days underwent BAV. Weight at time of procedure was 2.0-4.42 kgs. The median procedure and screening times were 82 and 7.9 minutes, respectively. Mean instantaneous Doppler gradient across the aortic valve reduced from 68 +/- 33 to 37 +/- 14 mmHg ( p < 0.0001). Three infants developed at least moderate aortic regurgitation. Right arm pulse volume was decreased in 12 infants; 5 received an intravenous heparin infusion. Longer-term follow-up demonstrated reduced or absent peripheral pulse in 5 infants. Transection of the axillary artery occurred in one infant requiring emergency microvascular repair. There was one post-procedural and one late death due to non-cardiac causes. CONCLUSIONS: In early infancy balloon aortic valvoplasty via the axillary artery approach for severe aortic stenosis is an acceptable and safe alternative to the femoral arterial approach and results in short procedure and screening times. Longer-term vascular follow-up is required. (c) 2006 Wiley-Liss, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo/métodos , Estenose da Valva Aórtica/congênito , Artéria Axilar , Humanos , Lactente , Recém-Nascido , Pulso Arterial , Estudos Retrospectivos , Resultado do Tratamento
10.
Ann Thorac Surg ; 81(3): 1127-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16488744

RESUMO

A 6-week-old infant presenting in heart failure was suspected on echocardiography of having anomalous origin of the whole coronary circulation from the pulmonary artery arising from a single ostium. This was confirmed at operation, and the child underwent successful correction. The management of cardiopulmonary bypass and myocardial protection in this abnormality is discussed.


Assuntos
Anormalidades Cardiovasculares/cirurgia , Vasos Coronários/anatomia & histologia , Vasos Coronários/cirurgia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Transposição dos Grandes Vasos/cirurgia , Aorta Torácica/cirurgia , Humanos , Lactente , Masculino , Resultado do Tratamento
11.
J Pediatr Surg ; 39(9): 1408-10, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15359400

RESUMO

Fetuses can survive with complete airway obstruction caused by placental gas exchange until birth when full ventilatory function is required. The authors present a case in which prenatal scans suggested that adequate ventilation would not be achievable because of the presence of an intrathoracic tumor. An EXIT procedure (exutero intrapartum treatment) was therefore performed, which permitted sufficient lung expansion for adequate ventilation.


Assuntos
Obstrução das Vias Respiratórias/etiologia , Cesárea , Neoplasias Cardíacas/cirurgia , Pericárdio/patologia , Rabdomioma/cirurgia , Esterno/cirurgia , Adulto , Obstrução das Vias Respiratórias/congênito , Biópsia , Baixo Débito Cardíaco/etiologia , Evolução Fatal , Feminino , Doenças Fetais/diagnóstico , Doenças Fetais/patologia , Doenças Fetais/terapia , Coração Fetal/embriologia , Idade Gestacional , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/embriologia , Neoplasias Cardíacas/terapia , Septos Cardíacos/patologia , Ventrículos do Coração/patologia , Humanos , Recém-Nascido , Intubação Intratraqueal , Terapia a Laser , Pulmão/embriologia , Masculino , Invasividade Neoplásica , Pericárdio/embriologia , Pericárdio/cirurgia , Poli-Hidrâmnios , Pré-Eclâmpsia , Gravidez , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Rabdomioma/complicações , Rabdomioma/embriologia , Rabdomioma/terapia , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa