RESUMO
The R3DR2 instrument performed measurements in the European Space Agency (ESA) EXPOSE-R2 platform outside the Russian "Zvezda" module of the International Space Station (ISS) in the period 24 October 2014-11 January 2016. It is the Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2015a). Took place in November 2014, this was the first attempt to monitor a small solar energetic particle (SEP) event outside ISS using the Liulin-type DES (Dachev et al., 2015d). In this study, we describe the dosimetric characteristics of the largest SEP event, observed on 22 June 2015 with the R3DR2 instrument outside ISS. The main finding of this study is that SEP protons with a minimum energy of approximately 7MeV at the surface of the R3DR2 detector produced high dose rates, reaching >5000µGyh(-1), while the inner radiation belt maximum dose was at the level of 2200µGyh(-1). If a virtual external vehicle activity (EVA) was performed in the same period of the SEP maximum on 22 June 2015, the doses obtained in the skin of cosmonauts/astronauts can reach 2.84mGy after 6.5h, which is similar to the average absorbed dose inside ISS for 15days (Reitz et al., 2005). A comparison with other extreme events measured with Liulin-type instruments shows that SEPs similar to that observed on 22 June 2015 could be one of the most dangerous events for the cosmonauts/astronauts involved in EVA.
Assuntos
Radiação Cósmica , Monitoramento de Radiação/instrumentação , Atividade Solar , Voo Espacial/instrumentação , Doses de Radiação , Proteção Radiológica , Fatores de TempoRESUMO
Ionizing radiation is recognized to be one of the main health concerns for humans in the space radiation environment. Estimation of space radiation effects on health requires the accurate knowledge of the accumulated absorbed dose, which depends on the global space radiation distribution, solar cycle and local shielding generated by the 3D mass distribution of the space vehicle. This paper presents an overview of the spectrometer-dosimeters of the Liulin type, which were developed in the late 1980s and have been in use since then. Two major measurement systems have been developed by our team. The first one is based on one silicon detector and is known as a Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2002, 2003), while the second one is a dosimetric telescope (DT) with two or three silicon detectors. The Liulin-type instruments were calibrated using a number of radioactive sources and particle accelerators. The main results of the calibrations are presented in the paper. In the last section of the paper some of the most significant scientific results obtained in space and on aircraft, balloon and rocket flights since 1989 are presented.
Assuntos
Radiação Cósmica , Doses de Radiação , Monitoramento de Radiação/instrumentação , Radiometria/instrumentação , Meio Ambiente Extraterreno , Humanos , Monitoramento de Radiação/métodos , Radiação Ionizante , Radiometria/métodos , Atividade Solar , Voo Espacial , AstronaveRESUMO
The LIULIN-3M instrument is a further development of the LIULIN dosimeter-radiometer, used on the MIR spacestation during the 1988-1994 time period. The LIULIN-3M is designed for continuous monitoring of the radiation environment during the BION-12 satellite flight in 1999. A semiconductor detector with 1 mm thickness and cm2 area is contained in the instrument. Pulse high analysis technique is used to determine the energy losses in the detector. The final data from the instrument are the flux and the dose rate for the exposure time and 256 channels of absorbed dose spectra based on the assumption that the particle flux is normal to the detector. The LIULIN-3M instrument was calibrated by proton fluxes with different energies at the Indiana University Cyclotron Facility in June 1997 and had been used for radiation measurements during commercial aircraft flights. The calibration procedure and some flight results are presented in this paper.
Assuntos
Aeronaves/instrumentação , Aviação/instrumentação , Ciclotrons , Monitoramento de Radiação/instrumentação , Altitude , Calibragem , SemicondutoresRESUMO
Measurements on board the Mir space station have been used to study the dose rate and the particle flux distribution in the inner magnetosphere. The measurements have been performed with the Bulgarian-Russian dosimeter-radiometer Liulin. The paper concentrates on the dynamics of the observed "new" and "second" maxima which were created after Solar Proton Events (SPE) in the 1989-1994 time. The "second" belt was first observed after the SPE on October 20, 1989, and the last observation was after the SPE on February 20, 1994. The creation of the "new" belt is a unique phenomena seen in the Liulin data set after the SPE on March 23, 1991 and relates to the magnetic storm on March 24. The new belt fully disappears in the middle of 1993.
Assuntos
Elétrons , Magnetismo , Prótons , Atividade Solar , Voo Espacial/instrumentação , Meio Ambiente Extraterreno , Doses de Radiação , Monitoramento de Radiação , Astronave/instrumentação , Ausência de PesoRESUMO
Using data from dosimetry-radiometry system "Liulin" on board of "Mir"-space station the particle flux and doserate during September-October, 1989 has been studied. The orbit of the station was 379 km perigee, 410 km apogee and 51.6 degrees inclination. Special attention has been paid to the flux and doserate changes inside the station after intensive solar proton events (SPE) on 29 of September, 1989. The comparison between the doses before and after the solar flares shows increase of the calculated mean dose per day by factor of 10 to 200. During the SPE on the 29 of September the additional dose was 310 mrad. The results of the experiment are compared with the data for the solar proton fluxes obtained on the GOES-7 satellite.
Assuntos
Radiação Cósmica , Prótons , Monitoramento de Radiação , Sistema Solar , Voo Espacial/instrumentação , Bulgária , Desenho de Equipamento , Doses de Radiação , Proteção Radiológica , Radiometria/instrumentação , Astronave/instrumentação , U.R.S.S.RESUMO
Measurements on board the MIR space station by the Bulgarian-Russian dosimeter LIULIN have been used to study the solar cycle variations of the radiation environment. The fixed locations of the instrument in the MIR manned compartment behind 6-15 g/cm2 of shielding have given homogeneous series of particle fluxes and doses measurements to be collected during the declining phase of 22nd solar cycle between September 1989 and April 1994. During the declining phase of 22nd solar cycle the GCR (Galactic Cosmic Rays) flux observed at L>4 (where L is the McIlwain parameter) has enhanced from 0.6-0.7 cm-2 s-1 up to 1.4-1.6 cm-2 s-1. The long-term observations of the trapped radiation can be summarized as follows: the main maximum of the flux and dose rate is located at the southeast side of the geomagnetic field minimum of South Atlantic Anomaly (SAA) at L=1.3-1.4. Protons depositing few (nGy cm2)/particle in the detector predominantly populate this region. At practically the same spatial location and for similar conditions the dose rate rises up from 480 to 1470 microGy/h dose in silicon in the 1990-1994 time interval, during the declining phase of the solar cycle. On the other hand the flux rises from 35 up to 115 cm-2 s-1 for the same period of time. A power law dependence was extracted which predicts that when the total neutral density at the altitude of the station decreases from 8x10(-15) to 6x10(-16) g/cm3 the dose increase from about 200 microGy/h up to 1200 microGy/h. At the same time the flux increase from about 30 cm-2 s-1 up to 120 cm-2 s-1. The AP8 model predictions give only 5.8% increase of the flux for the same conditions.
Assuntos
Radiação Cósmica , Monitoramento de Radiação/instrumentação , Atividade Solar , Voo Espacial/instrumentação , Astronave/instrumentação , Oceano Atlântico , Atmosfera/química , Modelos Teóricos , Doses de Radiação , Radiometria , América do Sul , Ausência de PesoRESUMO
Since 1988 high sensitivity semiconductor dosimeter-radiometer "Liulin" worked on board of MIR space station. Device measured the absorbed dose rate and the flux of penetrating particles. The analysis of the data shows the following new results: In October 1989 and after March 24, 1991, two additional stable maximums in flux channel were observed in the southern-eastern part of South Atlantic Anomaly (SAA). These two maximums existed at least several months and seem to be due to trapped high energy electron and proton fluxes. In April 1991 additional maximums were localized in the following geographical coordinates regions: latitude = (-35 degrees)-(-50 degrees) longitude = 332 degrees-l6 degrees and lat.(-46 degrees)-(-52 degrees) long. 360 degrees-60 degrees. Additional maximums diffusion occurs inside radiation belt. Appearance of these maximums seems to be closely connected with preceding powerful solar proton events and associated geomagnetic dynamics of new belt disturbances. Alter the series of solar proton events in June 1991 we observed significant enhancement of this new radiation belt formation. To achieve sufficient accuracy of dose rate predictions in low Earth orbits the structure and dynamics of new belt should be carefully analyzed to be included in a new environment model. From the inter comparison of the data from "Liulin" and French developed tissue equivalent LET spectrometer NAUSICAA in the time period August-November 1992 we come to the following conclusions: Mainly there is good agreement between both data sets for absorbed dose in the region of SAA; Different situation of the instruments on the station can explain the cases when differences up to 2 times are observed; At high latitudes usually the tissue equivalent absorbed dose observations are 2 times larger than "Liulin" doses.
Assuntos
Prótons , Monitoramento de Radiação/instrumentação , Atividade Solar , Astronave/instrumentação , Oceano Atlântico , Transferência Linear de Energia , Doses de Radiação , América do SulRESUMO
Radiation risk on a future long-duration manned space mission appears to be one of the basic factors in planning and designing the mission. Since 1988 different active dosimetric investigations has been performed on board the MIR space station by the Bulgarian-Russian dosimeter-radiometer LIULIN and French tissue-equivalent proportional counters CIRCE and NAUSICAA. A joint French-Bulgarian-Russian dosimetry experiment and the dosimetry-radiometry system RADIUS-MD have been developed for the future MARS-96 mission. On the base of the results and experience of these investigations a conception for a new radiation dose control system for the future orbital stations, lunar bases and interplanetary space ships is proposed. The proposed system which consists of different instruments will allow personal radiation control for crew members, radiation monitoring inside and outside each habitat, analysis and forecasting of the situation and will suggest procedures to minimize the radiation risk.