RESUMO
A new high-performance liquid chromatographic method with triple quadrupole mass spectrometry detection was developed and validated for the quantification of zopiclone enantiomers in rat brain samples. Zopiclone enantiomers were resolved on a CHIRALPAK AD column with a mobile phase consisting of acetonitrile/ethanol/methanol (60:20:20, v/v/v) at a flow rate of 1.3 mL min(-1). Moclobemide was used as internal standard. The sample treatment procedure was carried out employing solid-phase extraction, yielding mean absolute recoveries of 89.6 and 91.7% for each zopiclone enantiomer. The validated method showed linearity in the range of 0.29-344.8 ng g(-1), with quantification limits of 0.29 ng g(-1) for both enantiomers. Precision and accuracy were within acceptable levels of confidence (<15%). The method was applied in a pilot study of zopiclone kinetic disposition in rats. It could be observed that the levels of (+)-(S)-zopiclone were always higher than those of (-)-(R)-zopiclone, confirming the stereoselective disposition of zopiclone.
Assuntos
Compostos Azabicíclicos/análise , Compostos Azabicíclicos/farmacologia , Encéfalo/efeitos dos fármacos , Cromatografia Líquida/métodos , Piperazinas/análise , Piperazinas/farmacologia , Espectrometria de Massas em Tandem/métodos , Acetonitrilas/química , Animais , Técnicas de Química Analítica , Etanol/química , Hipnóticos e Sedativos/análise , Hipnóticos e Sedativos/farmacologia , Cinética , Masculino , Metanol/química , Modelos Químicos , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , EstereoisomerismoRESUMO
A capillary electrophoretic enantioselective method with UV detection was developed and validated for the simultaneous quantification of zopiclone enantiomers and its impurities, zopiclone-N-oxide enantiomers, and 2-amino-5-chloropyridine, in tablets. The analytes were extracted from the tablets using ACN and were separated in an uncoated fused-silica capillary (50 µm, 42 cm effective length, 50 cm total length) using 80 mM sodium phosphate buffer pH 2.5 and 5 mM carboxymethyl-ß-cyclodextrin as running buffer. The analytes and the internal standard (trimethoprim) were detected at 305 and 200 nm, respectively. A voltage of 27 kV was applied and the capillary temperature was maintained at 25°C. All enantiomers were analyzed within 8 min and linear calibration curves over the concentration range of 0.4-0.8 mg mL⻹ for each zopiclone enantiomer, 0.8-1.6 µg mL⻹ for 2-amino-5-chloropyridine and 0.4-0.8 µg mL⻹ for each zopiclone-N-oxide enantiomer were obtained. The coefficients of correlation obtained for the linear curves were greater than 0.99. The intra-day and inter-day accuracy and precision were lower than 2% for all analytes. This validated method was employed to study the degradation and racemization of zopiclone under stress conditions. This application demonstrated the importance of a stability-indicating assay method for this drug.
Assuntos
Compostos Azabicíclicos/análise , Eletroforese Capilar/métodos , Piperazinas/análise , Piridinas/análise , Compostos Azabicíclicos/química , Contaminação de Medicamentos , Estabilidade de Medicamentos , Análise dos Mínimos Quadrados , Limite de Detecção , Piperazinas/química , Piridinas/química , Reprodutibilidade dos Testes , Estereoisomerismo , Comprimidos/químicaRESUMO
A high-performance liquid chromatographic method with triple-quadrupole mass spectrometry detection (LC-MS-MS) was developed and validated for the first time for the simultaneous quantification of zopiclone and its metabolites in rat plasma samples. The analytes were isolated from rat plasma by liquid-liquid extraction and separated using a chiral stationary phase based on an amylose derivative, Chiralpak ADR-H column, and ethanol-methanol-acetonitrile (50:45:5, v/v/v) plus 0.025% diethylamine as the mobile phase, at a flow-rate of 1.0 mL min(-1). Moclobemide was used as the internal standard. The developed method was linear over the concentration range of 7.5-500 ng mL(-1). The mean absolute recoveries were 74.6 and 75.7; 61.6 and 56.9; 72.5, and 70.7 for zopiclone enantiomers, for N-desmethyl zopiclone enantiomers and for zopiclone-N-oxide enantiomers, respectively, and 75.9 for the internal standard. Precision and accuracy were within acceptable levels of confidence (<15%). The method application in a pilot study of zopiclone kinetic disposition in rats showed that the levels of (+)-(S)-zopiclone were always higher than those of (-)-R-zopiclone. Higher concentrations were also observed for (+)-(S)-N-desmethyl zopiclone and (+)-(S)-N-oxide zopiclone, confirming the stereoselective disposition of zopiclone.
Assuntos
Compostos Azabicíclicos/sangue , Piperazinas/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Compostos Azabicíclicos/química , Compostos Azabicíclicos/farmacocinética , Cromatografia Líquida de Alta Pressão , Hipnóticos e Sedativos , Piperazinas/química , Piperazinas/farmacocinética , Ratos , Padrões de Referência , Reprodutibilidade dos Testes , Estereoisomerismo , Espectrometria de Massas em Tandem/normasRESUMO
Zopiclone, zolpidem and zaleplon (Z-drugs) are nonbenzodiazepine hypnotic drugs that are used for the treatment of insomnia. These drugs were developed with the intent to overcome some disadvantages of benzodiazepines, such as dependence and next day sedation. In general, the nonbenzodiazepine hypnotic drugs are administered in oral doses daily and are widely biotransformed in the body. A large number of analytical methods based on chromatographic and electrophoretic techniques for the quantification of Z-drugs and their metabolites in biological matrices have been reported. In this review, the bioanalytical methods for Z-drugs were reviewed with the focus placed on sample preparation procedures and the separation techniques used. Furthermore, as these drugs are also reported as drugs of abuse or in drug-facilitated crime, screening methods that simultaneously cover these drugs and also other drugs of abuse were included in this review.