Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
J Ultrasound Med ; 43(1): 109-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772458

RESUMO

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Masculino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária , Estudos Prospectivos , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Mama/patologia , Sensibilidade e Especificidade , Diagnóstico Diferencial
2.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
3.
Ultraschall Med ; 44(2): 162-168, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34425600

RESUMO

PURPOSE: In this prospective, multicenter trial we evaluated whether additional shear wave elastography (SWE) for patients with BI-RADS 3 or 4 lesions on breast ultrasound could further refine the assessment with B-mode breast ultrasound for breast cancer diagnosis. MATERIALS AND METHODS: We analyzed prospective, multicenter, international data from 1288 women with breast lesions rated by conventional 2 D B-mode ultrasound as BI-RADS 3 to 4c and undergoing 2D-SWE. After reclassification with SWE the proportion of undetected malignancies should be < 2 %. All patients underwent histopathologic evaluation (reference standard). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 lesions (28.6 %). The assessment with B-mode breast ultrasound resulted in 1.39 % (6 of 431) undetected malignancies (malignant lesions in BI-RADS 3) and 53.80 % (495 of 920) unnecessary biopsies (biopsies in benign lesions). Re-classifying BI-RADS 4a patients with a SWE cutoff of 2.55 m/s resulted in 1.98 % (11 of 556) undetected malignancies and a reduction of 24.24 % (375 vs. 495) of unnecessary biopsies. CONCLUSION: A SWE value below 2.55 m/s for BI-RADS 4a lesions could be used to downstage these lesions to follow-up, and therefore reduce the number of unnecessary biopsies by 24.24 %. However, this would come at the expense of some additionally missed cancers compared to B-mode breast ultrasound (rate of undetected malignancies 1.98 %, 11 of 556, versus 1.39 %, 6 of 431) which would, however, still be in line with the ACR BI-RADS 3 definition (< 2 % of undetected malignancies).


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos , Biópsia
4.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35175381

RESUMO

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Algoritmos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imagem Multimodal
5.
Acta Radiol ; 58(6): 652-659, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27664278

RESUMO

Background Because of its small size, a focus in breast magnetic resonance imaging (MRI) must be evaluated on the basis of characteristics other than morphologic features. Patient-related factors including patient age, in conjunction with lesion-related factors, could be useful for decision-making. Purpose To assess the probability of malignant foci based on both lesion- and patient-related factors, and to propose a relevant decision-making method. Material and Methods Foci in our breast MRI database dating from April 2006 to June 2013 were retrospectively identified and analyzed. A Fisher's exact test or a Mann-Whitney U test were performed for univariate analyses, and factors that showed a significant association with outcome in the univariate analyses were subjected to multivariate analysis using a logistic regression model. A decision tree was then drawn using the significant predictors confirmed by multivariate analysis. Results In total, 184 foci (168 benign, 16 malignant) in 184 patients were analyzed in our study. The presence of a washout pattern and older age were found to be significant predictors of malignancy ( P < 0.0001; odds ratio [OR], 17.8; P = 0.021; OR, 1.1, respectively). The main decisive node on the decision tree was the presence of a washout pattern, followed by whether the patient's age was >63 years. Conclusion An enhancing focus showing a washout pattern, especially in older patients, may warrant immediate biopsy rather than short-interval follow-up.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Fatores Etários , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Cinética , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos
6.
Radiology ; 276(3): 686-94, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25875971

RESUMO

PURPOSE: To compare positive predictive values (PPVs) of linearly distributed nonmass enhancement (NME) with linear and branching patterns and to identify imaging characteristics of NME that would enable classification as Breast Imaging Reporting and Data System category 3 lesions. MATERIALS AND METHODS: The institutional review board approved this retrospective study and waived the requirement to obtain informed consent. Reports of breast magnetic resonance (MR) examinations (n = 9453) that described NME were reviewed from examinations performed at the study institution from January 2008 to December 2011. NME with linear distribution was allocated to one of two subtypes: linear pattern (arrayed in a line) or branching pattern (with branches). The χ(2) test, Fisher exact test, or Student t test was performed for univariate analyses. Factors that showed a significant association with outcome at univariate analyses were assessed with multivariate analyses by using a logistic regression model. Interobserver agreement of the two subtypes between initial interpretation and the interpretation by two additional radiologists who were blinded to any clinical or pathologic information was evaluated with κ analysis. RESULTS: Within the 156 linearly distributed NME lesions, the PPV of the branching pattern (71 of 95 lesions [75%]; 95% confidence interval [CI]: 66%, 84%) was significantly higher than that of the linear pattern (five of 61 lesions [8%]; 95% CI: 1%, 15%) (P < .0001). The PPV of linear pattern lesions smaller than 1 cm was 0% (0 of 30 lesions; 95% CI: 0%, 0%). At multivariate analysis, branching pattern and NME lesion size of 1 cm or greater were significant predictors of malignancy (P < .0001 [odds ratio: 21.6; 95% CI: 7.5, 62.2] and P = .015 [odds ratio: 5.8; 95% CI: 1.4, 24.0], respectively). Substantial interobserver agreement was obtained for differentiating the two subtypes, with κ values of 0.64 (95% CI: 0.51, 0.76), 0.70 (95% CI: 0.59, 0.82), and 0.64 (95% CI: 0.51, 0.76) between the initial interpreter and reviewer 1, the initial interpreter and reviewer 2, and reviewer 1 and reviewer 2, respectively. CONCLUSION: The branching pattern was a significantly stronger predictor of malignancy than was the linear pattern. NME lesions with a linear pattern that are smaller than 1 cm can be managed with follow-up.


Assuntos
Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/classificação , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
7.
J Magn Reson Imaging ; 41(2): 404-13, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24692302

RESUMO

PURPOSE: To demonstrate the noninferiority of gadobutrol-enhanced magnetic resonance imaging (MRI) compared with gadopentetate dimeglumine-enhanced MRI in Asian patients referred for contrast-enhanced imaging of the body or extremities. MATERIALS AND METHODS: A multicenter, parallel-group comparison study of Asian adults referred for contrast-enhanced MRI were randomized (1:1) to either gadobutrol or gadopentetate dimeglumine. Lesions were assessed for three primary visualization variables: degree of contrast enhancement, border delineation, and internal morphology. Secondary efficacy variables included number of lesions detected, match of MRI diagnosis with final clinical diagnosis, and sensitivity and specificity for malignant lesion detection. Safety was monitored for 24 ± 4 hours after contrast agent administration. RESULTS: A total of 363 patients received either gadobutrol (n = 168) or gadopentetate dimeglumine (n = 178). Mean total scores for three primary visualization variables were 9.39 and 9.34 for gadobutrol and gadopentetate dimeglumine, respectively. The proportion of patients with matched MRI and final diagnosis and sensitivity for malignant lesion detection was greater for unenhanced versus combined images (gadobutrol: 72.2% vs. 81.7%; gadopentetate dimeglumine: 76.2% vs. 82.2%, respectively). Both contrast agents were well tolerated. CONCLUSION: Gadobutrol (0.1 mmol/kg BW) was well tolerated and effective in Asian patients referred for contrast-enhanced MRI of the body or extremities.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos/administração & dosagem , China , Meios de Contraste/efeitos adversos , Feminino , Gadolínio DTPA/efeitos adversos , Humanos , Injeções , Japão , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/efeitos adversos , República da Coreia , Sensibilidade e Especificidade , Método Simples-Cego
8.
Magn Reson Med Sci ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38522915

RESUMO

PURPOSE: To investigate the characteristics of suspicious MRI-only visible lesions and to explore the validity of subcategorizing these lesions into the following two groups: lesions that would require immediate biopsy (4Bi) and lesions for which careful clinical follow-up could be recommended (4Fo). METHODS: A retrospective review of 108 MRI-only visible lesions in 106 patients who were diagnosed as Breast Imaging Reporting and Data System (BI-RADS) category 4 between June 2018 and June 2022 at our institution was performed by two radiologists. The breast MR images were evaluated according to BI-RADS and additional MRI descriptors (linear ductal, branching, and apparent diffusion coefficient values). The lesions were categorized by previously reported classification systems, and the positive predictive values (PPVs) for the different categories were determined and compared. Subsequently, a new classification system was developed in this study. RESULTS: The total malignancy rate was 31% (34/108). No significant differences between benign and malignant lesions were identified for focus and mass lesions. For non-mass lesions, linear ductal and heterogeneous internal enhancement suggested a benign lesion (P = 0.0013 and P = 0.023, respectively), and branching internal enhancement suggested malignancy (P = 0.0066). Segmental distribution suggested malignancy (P = 0.0097). However, the PPV of segmental distribution with heterogeneous enhancement was significantly lower than that of category 4 segmental lesions with other enhancement patterns (11% vs. 59%; P = 0.0198).As a new classification, the distribution of focal, linear, and segmental was given a score of 0, 1, or 2, and the internal enhancement of heterogeneous, linear-ductal, clumped, branching, and clustered-ring enhancement was given a score of 0, 1, 2, 3, and 4, respectively. When categorized using a scoring system, a statistically significant difference in PPV was observed between 4Fo (n = 27) and 4Bi (n = 33) (7% vs. 61%, P = 0.000029). CONCLUSION: The new classification system was found to be highly capable of subcategorizing BI-RADS category 4 MRI-only visible non-mass lesions into 4Fo and 4Bi.

9.
Jpn J Radiol ; 42(7): 720-730, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38503998

RESUMO

PURPOSE: This study aimed to enhance the diagnostic accuracy of contrast-enhanced breast magnetic resonance imaging (MRI) using gadobutrol for differentiating benign breast lesions from malignant ones. Moreover, this study sought to address the limitations of current imaging techniques and criteria based on the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS: In a multicenter retrospective study conducted in Japan, 200 women were included, comprising 100 with benign lesions and 100 with malignant lesions, all classified under BI-RADS categories 3 and 4. The MRI protocol included 3D fast gradient echo T1- weighted images with fat suppression, with gadobutrol as the contrast agent. The analysis involved evaluating patient and lesion characteristics, including age, size, location, fibroglandular tissue, background parenchymal enhancement (BPE), signal intensity, and the findings of mass and non-mass enhancement. In this study, univariate and multivariate logistic regression analyses were performed, along with decision tree analysis, to identify significant predictors for the classification of lesions. RESULTS: Differences in lesion characteristics were identified, which may influence malignancy risk. The multivariate logistic regression model revealed age, lesion location, shape, and signal intensity as significant predictors of malignancy. Decision tree analysis identified additional diagnostic factors, including lesion margin and BPE level. The decision tree models demonstrated high diagnostic accuracy, with the logistic regression model showing an area under the curve of 0.925 for masses and 0.829 for non-mass enhancements. CONCLUSION: This study underscores the importance of integrating patient age, lesion location, and BPE level into the BI-RADS criteria to improve the differentiation between benign and malignant breast lesions. This approach could minimize unnecessary biopsies and enhance clinical decision-making in breast cancer diagnostics, highlighting the effectiveness of gadobutrol in breast MRI evaluations.


Assuntos
Neoplasias da Mama , Meios de Contraste , Imageamento por Ressonância Magnética , Compostos Organometálicos , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Idoso , Diagnóstico Diferencial , Mama/diagnóstico por imagem , Japão , Idoso de 80 Anos ou mais , Aumento da Imagem/métodos , Sensibilidade e Especificidade , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
10.
Breast Cancer Res Treat ; 136(3): 919-26, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23143284

RESUMO

Data reviewed at the Kyoto Breast Cancer Consensus Conference (KBCCC) showed that preoperative systemic therapy (PST) could optimize surgery through the utilization of information relating to pre- and post-PST tumor stage, therapeutic sensitivity, and treatment-induced changes in the biological characteristics of the tumor. As such, it was noted that the biological characteristics of the tumor, such as hormone receptors, human epidermal growth factor receptor-2, histological grade, cell proliferative activity, mainly defined by the Ki67 labeling index, and the tumor's multi-gene signature, should be considered in the planning of both systemic and local therapy. Furthermore, the timing of axillary sentinel lymph node diagnosis (i.e., before or after the PST) was also noted to be critical in that it may influence the likelihood of axillary preservation, even in node positive cases. In addition, axillary diagnosis with ultrasound and concomitant fine needle aspiration cytology or core needle biopsy (CNB) was reported to contribute to the construction of a treatment algorithm for patient-specific or individualized axillary surgery. Following PST, planning for breast surgery should therefore be based on tumor subtype, tumor volume and extent, therapeutic response to PST, and patient preference. Nomograms for predicting nodal status and drug sensitivity were also recognized as a tool to support decision-making in the selection of surgical treatment. Overall, review of data at the KBCCC showed that PST increases the likelihood of patients receiving localized surgery and individualized treatment regimens.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/terapia , Cuidados Pré-Operatórios , Algoritmos , Axila/cirurgia , Neoplasias da Mama/metabolismo , Feminino , Humanos , Metástase Linfática/patologia , Terapia Neoadjuvante , Nomogramas , Biópsia de Linfonodo Sentinela , Carga Tumoral
11.
Magn Reson Med Sci ; 21(3): 485-498, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34176860

RESUMO

PURPOSE: We evaluated the diagnostic performance of the texture features of dynamic contrast-enhanced (DCE) MRI for breast cancer diagnosis in which the discriminator was optimized, so that the specificity was maximized via the restriction of the negative predictive value (NPV) to greater than 98%. METHODS: Histologically proven benign and malignant mass lesions of DCE MRI were enrolled retrospectively. Training and testing sets consist of 166 masses (49 benign, 117 malignant) and 50 masses (15 benign, 35 malignant), respectively. Lesions were classified via MRI review by a radiologist into 4 shape types: smooth (S-type, 34 masses in training set and 8 masses in testing set), irregular without rim-enhancement (I-type, 60 in training and 14 in testing), irregular with rim-enhancement (R-type, 56 in training and 22 in testing), and spicula (16 in training and 6 in testing). Spicula were immediately classified as malignant. For the remaining masses, 298 texture features were calculated using a parametric map of DCE MRI in 3D mass regions. Masses were classified into malignant or benign using two thresholds on a feature pair. On the training set, several feature pairs and their thresholds were selected and optimized for each mass shape type to maximize specificity with the restriction of NPV > 98%. NPV and specificity were computed using the testing set by comparison with histopathologic results and averaged on the selected feature pairs. RESULTS: In the training set, 27, 12, and 15 texture feature pairs are selected for S-type, I-type, and R-type masses, respectively, and thresholds are determined. In the testing set, average NPV and specificity using the selected texture features were 99.0% and 45.2%, respectively, compared to the NPV (85.7%) and specificity (40.0%) in visually assessed MRI category-based diagnosis. CONCLUSION: We, therefore, suggest that the NPV of our texture-based features method described performs similarly to or greater than the NPV of the MRI category-based diagnosis.


Assuntos
Neoplasias da Mama , Meios de Contraste , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
Eur J Cancer ; 161: 1-9, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34879299

RESUMO

BACKGROUND: Shear wave elastography (SWE) and strain elastography (SE) have shown promising potential in breast cancer diagnostics by evaluating the stiffness of a lesion. Combining these two techniques could further improve the diagnostic performance. We aimed to exploratorily define the cut-offs at which adding combined SWE and SE to B-mode breast ultrasound could help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3-4 lesions to reduce the number of unnecessary breast biopsies. METHODS: We report the secondary results of a prospective, multicentre, international trial (NCT02638935). The trial enrolled 1288 women with BI-RADS 3 to 4c breast masses on conventional B-mode breast ultrasound. All patients underwent SWE and SE (index test) and histopathologic evaluation (reference standard). Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after recategorising with SWE and SE were the outcome measures. RESULTS: On performing histopathologic evaluation, 368 of 1288 breast masses were malignant. Following the routine B-mode breast ultrasound assessment, 53.80% (495 of 920 patients) underwent an unnecessary biopsy. After recategorising BI-RADS 4a lesions (SWE cut-off ≥3.70 m/s, SE cut-off ≥1.0), 34.78% (320 of 920 patients) underwent an unnecessary biopsy corresponding to a 35.35% (320 versus 495) reduction of unnecessary biopsies. Malignancies in the new BI-RADS 3 cohort were missed in 1.96% (12 of 612 patients). CONCLUSION: Adding combined SWE and SE to routine B-mode breast ultrasound to recategorise BI-RADS 4a patients could help reduce the number of unnecessary biopsies in breast diagnostics by about 35% while keeping the rate of undetected malignancies below the 2% ACR BI-RADS 3 definition.


Assuntos
Biópsia/métodos , Neoplasias da Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Pessoa de Meia-Idade
13.
Eur J Cancer ; 177: 1-14, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36283244

RESUMO

BACKGROUND: Breast ultrasound identifies additional carcinomas not detected in mammography but has a higher rate of false-positive findings. We evaluated whether use of intelligent multi-modal shear wave elastography (SWE) can reduce the number of unnecessary biopsies without impairing the breast cancer detection rate. METHODS: We trained, tested, and validated machine learning algorithms using SWE, clinical, and patient information to classify breast masses. We used data from 857 women who underwent B-mode breast ultrasound, SWE, and subsequent histopathologic evaluation at 12 study sites in seven countries from 2016 to 2019. Algorithms were trained and tested on data from 11 of the 12 sites and externally validated using the additional site's data. We compared findings to the histopathologic evaluation and compared the diagnostic performance between B-mode breast ultrasound, traditional SWE, and intelligent multi-modal SWE. RESULTS: In the external validation set (n = 285), intelligent multi-modal SWE showed a sensitivity of 100% (95% CI, 97.1-100%, 126 of 126), a specificity of 50.3% (95% CI, 42.3-58.3%, 80 of 159), and an area under the curve of 0.93 (95% CI, 0.90-0.96). Diagnostic performance was significantly higher compared to traditional SWE and B-mode breast ultrasound (P < 0.001). Unlike traditional SWE, positive-predictive values of intelligent multi-modal SWE were significantly higher compared to B-mode breast ultrasound. Unnecessary biopsies were reduced by 50.3% (79 versus 159, P < 0.001) without missing cancer compared to B-mode ultrasound. CONCLUSION: The majority of unnecessary breast biopsies might be safely avoided by using intelligent multi-modal SWE. These results may be helpful to reduce diagnostic burden for patients, providers, and healthcare systems.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos Retrospectivos , Ultrassonografia Mamária , Biópsia , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial
14.
Acta Radiol ; 52(7): 706-10, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21596798

RESUMO

BACKGROUND: Power Doppler ultrasonography (US) is used in addition to B-mode US as a tool for the differential diagnosis between benign and malignant lesions. However, there are few data showing how useful power Doppler US is for BI-RADS category assessment. PURPOSE: To assess how much power Doppler US contributed to increasing the category diagnosis from Breast Imaging Reporting and Data System (ACR BI-RADS(®)-US) category 3 to category 4. MATERIAL AND METHODS: A total of 2426 patients (age range 16-91 years, mean 52 years) who underwent B-mode and power Doppler breast US using a linear 10-MHz transducer were analyzed. We devised integrated US category classification (BI-RADS-Integral) based on BI-RADS descriptors and vascularity. Masses with a circumscribed margin, parallel orientation, and negative vascularity on power Doppler US were defined as category 3. Irregular-shaped masses with a spiculated margin or echogenic halo were defined as category 5. Masses with one of the four suspicious findings (no circumscribed margin, no parallel orientation, microcalcifications, and positive vascularity) were defined as category 4a, and masses with two or more suspicious findings were defined as category 4b. RESULTS: There were 98 breast cancer cases, and the average sizes of invasive and non-invasive cancers were 15 mm and 18 mm, respectively. The frequency of breast cancer according to category was: 0.4% (3/714) of the category 3 cases, 2.7% (7/256) in category 4a, 64% (47/73) in category 4b, and 100% (41/41) in category 5. Among the cases with a category 4a mass lesion, there were 183 lesions whose category diagnosis had been raised from category 3 to category 4a based on the Doppler blood flow findings alone, and 3 (1.6%) of those lesions were breast cancer. All three of them were ductal carcinoma in situ (DCIS) cases. When the cut-off point was placed between category 3 and category 4, BI-RADS-Integral and BI-RADS-US without power Doppler had a sensitivity of 96.9% and 93.9%, respectively, specificity of 72.1% and 90.4%, respectively, and accuracy of 74.4% and 90.7%, respectively. CONCLUSION: The presence of Doppler blood flow increases the malignancy pick-up rate, but at the expense of a significant decrease in specificity and diagnostic accuracy and an increase in biopsy rate.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Doppler , Ultrassonografia Mamária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Acta Radiol ; 52(10): 1069-75, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22013011

RESUMO

BACKGROUND: ShearWave™ Elastography (SWE) provides a quantitative measurement of tissue stiffness and may improve characterization of breast masses. However, the significance of Young's modulus measurements and appropriate SWE evaluation criteria has not been established yet. PURPOSE: To assess the usefulness of the pattern classification and Young's modulus measurements in the differential diagnosis between benign and malignant solid breast masses. MATERIAL AND METHODS: Ninety-six patients (age range 18-84 years, mean 54 years) with 100 solid breast masses who underwent tissue sampling after a US examination were analyzed. We tried to create a visual pattern classification based on the SWE images. After classifying the visual patterns, the Young's modulus of the lesions was measured in every case. RESULTS: It was possible to classify the images into four patterns by the visual evaluation: no findings (coded blue homogeneously; Pattern 1), vertical stripe pattern artifacts (Pattern 2), a localized colored area at the margin of the lesion (Pattern 3), and heterogeneously colored areas in the interior of the lesion (Pattern 4). There were 17 Pattern 1 lesions, 14 Pattern 2 lesions, 20 Pattern 3 lesions, and 49 Pattern 4 lesions. When Patterns 1 and 2 were assumed to be benign, and Patterns 3 and 4 were assumed to be malignant, the sensitivity and specificity were 91.3% (63/69) and 80.6% (25/31), respectively. The mean Young's modulus measurements of the benign and the malignant lesions were 42 kPa and 146 kPa, respectively (P < 0.0001). No significant differences were found between benign and malignant lesions in Pattern 3. In Pattern 4, however, the Young's modulus of the benign lesions (50 kPa) was lower than the smallest Young's modulus of malignant lesions (61 kPa). CONCLUSION: The visual pattern classification and adding Young's modulus measurements may improve characterization of solid breast masses.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Mamárias/diagnóstico por imagem , Diagnóstico Diferencial , Módulo de Elasticidade , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem
16.
Breast Cancer ; 28(6): 1181-1187, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32627143

RESUMO

Overseas, the importance for breast MRI screening for high-risk groups has been shown. However, the evidence among Japanese population was lacking. Therefore, we collaborated with the "Study on clinical and genetic characterization of hereditary breast and ovarian cancer and improvement in prognosis using genetic information in Japan" group, as part of the Comprehensive Research Project on the Promotion of Cancer Control, Health and Labour Sciences Research, and have been conducting the study entitled, "Study of the usefulness of MRI surveillance of BRCA1/2 mutation carriers" since 2014. In addition, we found that in the Japanese population also, the pathological and imaging characteristics differ between BRCA1 and BRCA2 mutation carriers, like in non-Japanese populations by the several reports. In high-risk females, risk categories such as BRCA1 or BRCA2 mutation carriers are very important. Furthermore, in the future, the optimal surveillance modalities and examination intervals would also vary according to the age, thinness of the breast (constitution), breast density (individual differences on mammography), etc.; this would be "personalized surveillance", and quality-assured MRI examination is of the essence. This review will present clinical trial data of prospective MRI surveillance in Japan, and summarize the current status of breast cancer screening in high-risk Japanese women.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Adulto , Proteína BRCA1 , Proteína BRCA2 , Neoplasias da Mama/genética , Feminino , Humanos , Japão , Imageamento por Ressonância Magnética/normas , Programas de Rastreamento , Pessoa de Meia-Idade , Fatores de Risco
17.
Breast Cancer ; 28(6): 1188-1194, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32632846

RESUMO

In April 2018, the national health insurance coverage of MRI-guided vacuum-assisted breast biopsy (VAB) was instituted with the application of the Japan Breast Cancer Society. Although MRI-guided VAB has been considered as a special procedure for a long time, having an access to this procedure should be recommended for facilities performing breast MRI as in Western countries. From now on, relevant societies should make efforts in data collection and quality control of MRI-guided VAB in Japan. We must avoid the following. To delay the early diagnosis of breast cancer in the judgment of an inaccurate indication, perform unnecessary biopsy due to overestimation of diagnosis, and reduce the success rate of MRI-guided VAB with immature techniques. This review explains the current status of MRI-guided VAB in Japan and shares procedure and biopsy data as a future reference from an experienced facility.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Proteína BRCA1 , Proteína BRCA2 , Feminino , Humanos , Cobertura do Seguro , Japão , Pessoa de Meia-Idade , Programas Nacionais de Saúde
18.
Breast Cancer ; 28(4): 927-936, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33625722

RESUMO

BACKGROUND: The high concentration of gadolinium in gadobutrol, which is widely used in Japan, helps visualize signal enhancement of neoplastic lesions, however, there was concern that high T1 relaxivity could decrease the contrast between the lesion and the background mammary gland. We evaluate the effect of gadobutrol on background parenchymal enhancement (BPE) and differential diagnosis between benign and malignant lesions in dynamic MRI of the breast. METHODS: Ninety-nine patients were enrolled prospectively. Measurements of the following signal intensities (SIs) were obtained: breast tissue on a pre-contrast image (SIpre) and an early-phase image (SIearly); and the SIs of breast cancer on a pre-contrast image (SIpre-cancer) and an early-phase image (SIearly-cancer). We calculated the BPE ratio, i.e., (SIearly - SIpre)/SIpre and the cancer/BPE ratio, i.e., (SIearly-cancer - SIpre-cancer)/(SIearly on the affected side - SIpre on the affected side). These quantitative assessments were compared with the data from the recently published multicenter study (reference study without use of gadobutrol). In addition, two radiologists reinterpreted each of the MR images, and a third radiologist set the ROIs in the lesions and performed kinetic analysis as a Reader 3. RESULTS: While there was no significant difference in the SI of breast cancer in the premenopausal patients between the two studies, that in postmenopausal patients was significantly higher in the present study than in the reference study (p = 0.002). Although there was no significant difference in the cancer/BPE ratio in the postmenopausal patients between the two studies, the cancer/BPE ratio in the premenopausal patients was significantly higher in the reference study than in the present study (p = 0.028). For differentiation between benign and malignant masses, the mass margin was found to be the most important term (p < 0.001). According to the data of Reader 3, visual washout was observed in all 18 patients in whom the interpretation was changed from "plateau" to "washout". CONCLUSIONS: Gadobutrol may decrease the contrast between breast cancer and background parenchyma in premenopausal patients, and it may have a characteristic that "washout" does not easily occur, leading to "plateau" in patients with breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Compostos Organometálicos/administração & dosagem , Tecido Parenquimatoso/patologia , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Estudos Prospectivos
19.
J Magn Reson Imaging ; 31(4): 895-902, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373434

RESUMO

PURPOSE: To assess the efficacy of quantitative (1)H MR spectroscopy (MRS) using the external standard method to predict the pathological response to neoadjuvant chemotherapy with an anthracycline-based regimen in breast cancer patients. MATERIALS AND METHODS: Sixteen patients with breast cancer were included. Tumor response to chemotherapy was evaluated after the second cycle using MRI and MRS. Final histopathology following surgery after four cycles of chemotherapy served as reference. RESULTS: The average normalized choline (Cho) signal was 1.2 (range, 0.40 to 2.8). There were no significant differences in the baseline tumor size and normalized Cho signals between the pathological responders (n = 8) and nonresponders (n = 8). The reduction rates of the normalized Cho signal were statistically significantly different between the pathological responders and nonresponders (P = 0.004), whereas the reduction rates of the lesion size were not significantly different between the two groups. When 40-50% of the reduction rates of the normalized Cho was chosen as the cutoff value, the positive and negative predictive values of MRS were 89% (8/9) and 100% (7/7), respectively. CONCLUSION: The changes in Cho after the second cycle of chemotherapy as determined by quantitative MRS may be more sensitive than changes in the tumor size to predict the pathological response.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Espectroscopia de Ressonância Magnética/métodos , Terapia Neoadjuvante/métodos , Adulto , Algoritmos , Antraciclinas/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/terapia , Colina/química , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
20.
AJR Am J Roentgenol ; 194(5): 1384-90, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20410429

RESUMO

OBJECTIVE: The purpose of this article is to assess the histologic prognostic relevance of choline levels obtained using (1)H MR spectroscopy with a 1.5-T MR unit in patients with invasive breast cancer and to compare the observed choline levels with the standardized uptake value obtained using FDG PET. MATERIALS AND METHODS: Single-voxel (1)H MR spectroscopy and PET/CT were performed for 50 patients with invasive ductal carcinoma (1.5-3 cm in size). The normalized choline signal was calculated using an external standard method. RESULTS: Proton MR spectroscopy detected the presence of choline in 44 cases. The average normalized choline signal was 1.1 (range, 0-3.9). The average standardized uptake value was 6.5 (range, 1.1-23). The correlation (r) between the normalized choline signal and the standardized uptake value was 0.52 (p < 0.0001). The normalized choline signal was significantly correlated with nuclear grade (p = 0.0002), triple-negative breast cancer status (p = 0.0009), and estrogen receptor negativity (p = 0.007). The standardized uptake value was significantly correlated with nuclear grade (p = 0.0002), estrogen receptor negativity (p = 0.002), and triple-negative breast cancer status (p = 0.009). No significant differences were found between the progesterone receptor-positive and negative groups or between the human epidermal growth factor receptor 2-positive and negative groups. CONCLUSION: The choline levels obtained using (1)H MR spectroscopy with a 1.5-T unit were well correlated with the standardized uptake value obtained using PET/CT and with the histologic prognostic parameters (nuclear grade, estrogen receptor status, and triple-negative lesion status).


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/epidemiologia , Fluordesoxiglucose F18 , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Feminino , Humanos , Japão/epidemiologia , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Prevalência , Prognóstico , Prótons , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa