Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38747022

RESUMO

PURPOSE: The purpose of this study was to investigate if patient's gender significantly affected the long-term outcome of patients undergoing total knee arthroplasty (TKA) and to provide a cross-gender comparison of a large patient sample from a single regional register. METHODS: The Registry of Prosthetic Orthopedic Implant of Emilia Romagna (RIPO) investigated all primary TKAs performed from July 2000 to December 2020 by collecting data of men and women separately. Primary bicompartmental and tricompartmental TKAs were included. The survival rates and the reasons for revision were assessed to check if any other factor could have influenced implant failure. RESULTS: In total, 66,032 TKAs were included and analysed, comprising 46,774 women and 19,258 men. The 15-year Kaplan-Meier survival percentage was 93.6% for women and 92.5% for men (p = 0.001). Men exhibited a higher revision risk following primary TKA (p = 0.012), particularly when the primary diagnosis was arthritis resulting from rheumatic disorders (p = 0.018) and arthritis following high-tibial osteotomy (p = 0.024). Failure risk was also higher for men below the age of 60 years (p = 0.038). CONCLUSION: The long-term outcome in TKA showed significant differences between men and women, with a significantly lower survival rate in men at 15 years, especially when they are under 60 years old or with a diagnosis of rheumatic disorders or arthritis following high-tibial osteotomy. It is necessary to design specific studies to have relevant data concerning gender differences in prosthetic surgery and to customise treatments to improve outcome and patient satisfaction. LEVEL OF EVIDENCE: Level III.

2.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 685-692, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38415872

RESUMO

PURPOSE: It was hypothesized that robotic arm-assisted total knee arthroplasty (RA-TKA) using additionally a gap-balancing instrumentation will show high accuracy in executing the planning in femoral and tibial component placement throughout the range of knee motion (ROM) during TKA surgery. METHODS: Prospectively collected data were analysed for patients undergoing RA-TKA. A cruciate retaining cemented design was implanted using the MAKO® robotic system. Lower limb alignment at 0°, 30°, 45°, 60° and 90° of flexion was recorded at the beginning of surgery and finally after implantation of the components. A ligament tensioner was inserted after tibial precut to measure the extension and flexion gap, and final component placement was planned based on 3D CT images. Femoral and tibial component placement was measured in all three planes. RESULTS: A total of 104 patients were included (mean age 69.4 ± 9 years; 44 male, 60 female). The difference in component placement after planning and final implantation showed less valgus of 0.7° ± 1.4° (p < 0.001), less external rotation of 0.6° ± 1.9° (p = 0.001) and less flexion of 0.9° ± 1.8° (p < 0.001) for the femoral component. The tibial component was placed in more varus of 0.2° ± 0.9° (p = 0.056) and more posterior slope of 0.5° ± 0.9° (p < 0.001). The lower limb alignment in extension was 4.4° ± 5.2° of varus of the native knee and changed to 1.2° ± 1.9° of varus after TKA (p < 0.01). CONCLUSION: Robotic-assisted TKA helps to achieve the target of alignment and component placement very close to the planning. It allows optimal component placement of off-the-shelf implants respecting patient's specific anatomy. LEVEL OF EVIDENCE: Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
3.
Int J Mol Sci ; 25(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38338653

RESUMO

Peripheral inflammation and gait speed alterations are common in several neurological disorders and in the aging process, but the association between the two is not well established. The aim of this systematic literary review is to determine whether proinflammatory markers are a positive predictor for gait impairments and their complications, such as falls in older adults, and may represent a risk factor for slow gait speed and its complications. The systematic review was performed in line with the Preferred Report Items for Systematic Review and Meta-Analyses (PRISMA). A protocol for literature searches was structured a priori and designed according to the International Perspective Register of Systemic Review (PROSPERO: CRD42023451108). Peer-reviewed original articles were identified by searching seven electronic databases: Excerpta Medica Database (EMBASE), SciVerse (ScienceDirect), Scopus, PubMed, Medline, Web of Science, and the Cochrane Library. The search strategy was formulated based on a combination of controlled descriptors and/or keywords related to the topic and a manual search was conducted of the reference lists from the initially selected studies to identify other eligible studies. The studies were thoroughly screened using the following inclusion criteria: older adults, spatiotemporal gait characteristics, and proinflammatory markers. A meta-analysis was not performed due to the heterogeneity of the studies, and the results were narratively synthesized. Due to the clinical and methodological heterogeneity, the studies were combined in a narrative synthesis, grouped by the type of biomarkers evaluated. A standardized data extraction form was used to collect the following methodological outcome variables from each of the included studies: author, year, population, age, sample size, spatiotemporal gait parameters such as gait velocity, and proinflammatory markers such as TNF-α, high sensitivity C-reactive (CRP) proteins, and IL-6. We included 21 out of 51 studies in our review, which examined the association between inflammatory biomarkers and gait impairment. This review highlights the role of TNF-α, CRP, and IL-6 in gait impairment. Biomarkers play an important role in the decision-making process, and IL-6 can be an effective biomarker in establishing the diagnosis of slow gait speed. Further longitudinal research is needed to establish the use of molecular biomarkers in monitoring gait impairment.


Assuntos
Interleucina-6 , Fator de Necrose Tumoral alfa , Biomarcadores , Marcha , Fatores de Risco
4.
J Environ Manage ; 351: 119836, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38141345

RESUMO

The present study investigated the combined production of reclaimed water for reuse purposes and polyhydroxyalkanoates (PHA) from an agro-food industrial wastewater. A pilot plant implementing a two-stage process for PHA production was studied. It consisted of a mainstream sequencing batch membrane bioreactor (SBMBR) in which selection of PHA-accumulating organisms and wastewater treatment were carried out in, and a side-stream fed-batch reactor (FBR) where the excess sludge from the SBMBR was used for PHA accumulation. The performance of the SBMBR was compared with that of a conventional sequencing batch reactor (SBR) treating the same wastewater under different food to microorganisms' ratios (F/M) ranging between 0.125 and 0.650 kgCOD kgTSS-3 d-1. The SBMBR enabled to obtain very high-quality effluent in compliance with the relevant national (Italy) and European regulations (Italian DM 185/03 and EU, 2020/741) in the field of wastewater reclamation, whereas the performances in the SBR collapsed at F/M higher than 0.50 kgCOD kgTSS-1d-1. A maximum intracellular storage of 45% (w/w) and a production yield of 0.63 gPHA L-1h-1 were achieved when the SBMBR system was operated with a F/M ratio close to 0.50 kgCOD kgTSS-1d-1. This resulted approximately 35% higher than those observed in the SBR, since the ultrafiltration membrane avoided the washout of dispersed and filamentous bacteria capable of storing PHA. Furthermore, while maximizing PHA productivity in conventional SBR systems led to process dysfunctions, in the SBMBR system it helped mitigate these issues by reducing membrane fouling behaviour. The results of this study supported the possibility to achieve combined recovery of reclaimed water and high-value added bioproducts using membrane technology, leading the way for agro-food industrial wastewater valorization in the frame of a circular economy model.


Assuntos
Poli-Hidroxialcanoatos , Águas Residuárias , Reatores Biológicos/microbiologia , Esgotos , Bactérias
5.
Arch Orthop Trauma Surg ; 144(3): 1423-1435, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112778

RESUMO

INTRODUCTION: The purpose of this retrospective registry-based study is to assess survival and causes of failure of cementless stem implants used in total hip arthroplasty (THAs), to ascertain if there are differences when these are categorized according to the six types described by Mont. METHODS: Data collected from the regional registry regarding all primary THAs performed from 2000 to 2019 were analyzed. Femoral prosthetic stems were divided into the six types of Mont classification. For each stem type, number of implants, survival and causes of failure were evaluated and compared. RESULTS: The most frequently implanted stem type was the 3c type (53.4%). Type 1 had the lowest stem failure rate (1.6%), and type 6 showed the highest (3.9%). Periprosthetic fracture was the most frequent complication in type 6, accounting for 34.5% of failures. Aseptic loosening was the main complication in type 2 stems, accounting for 36.4% of failures. Pairwise comparisons showed significant higher survival of type 1 compared to type 3c (p = 0.000026) and type 6 (p = 0.000076), and between type 3a compared to type 3c (p = 0.03) and type 6 (p = 0.026). CONCLUSION: Significant variations in implant survival rates were found among the six Mont-types of cementless stems. These findings emphasize the paramount importance of stem design and fixation area in determining long-term survival, providing a guidance for orthopedic surgeons in the selection of the most appropriate stem for primary THA, contributing to our understanding of cementless stem performance, presenting invaluable insights to further improve patient outcomes in THA surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Reoperação , Sistema de Registros , Falha de Prótese
6.
Arch Orthop Trauma Surg ; 144(4): 1821-1833, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472450

RESUMO

The hip-spine relationship is a critical consideration in total hip arthroplasty (THA) procedures. While THA is generally successful in patient, complications such as instability and dislocation can arise. These issues are significantly influenced by the alignment of implant components and the overall balance of the spine and pelvis, known as spinopelvic balance. Patients with alteration of those parameters, in particular rigid spines, often due to fusion surgery, face a higher risk of THA complications, with an emphasis on complications in instability, impingement and dislocation. For these reasons, over the years, computer modelling and simulation techniques have been developed to support clinicians in the different steps of surgery. The aim of the current review is to present current knowledge on hip-spine relationship to serve as a common platform of discussion among clinicians and engineers. The offered overview aims to update the reader on the main critical aspects of the issue, from both a theoretical and practical perspective, and to be a valuable introductory tool for those approaching this problem for the first time.


Assuntos
Artroplastia de Quadril , Luxações Articulares , Humanos , Coluna Vertebral/cirurgia , Artroplastia de Quadril/efeitos adversos , Luxações Articulares/cirurgia , Pelve/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
7.
Medicina (Kaunas) ; 60(1)2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38256376

RESUMO

Background and Objectives: total hip arthroplasty (THA) for Crowe IV hip dysplasia poses challenges due to severe leg shortening, muscle retraction and bone stock issues, leading to an increased neurological complication, and revision rate. The direct anterior approach (DAA) is used for minimally invasive THA but its role in Crowe IV dysplasia is unclear. This retrospective study examines if DAA effectively restores hip biomechanics in Crowe IV dysplasia patients with <4 cm leg length discrepancy, managing soft tissue and yielding functional improvement, limb length correction, and limited complications. Materials and Methods: 19 patients with unilateral Crowe IV hip osteoarthritis and <4 cm leg length discrepancy undergoing DAA THA were reviewed. Surgery involved gradual soft tissue release, precise acetabular cup positioning, and stem placement without femoral osteotomy. Results: results were evaluated clinically and radiographically, with complications recorded. Follow-up revealed significant Harris Hip Score and limb length discrepancy improvements. Abductor muscle insufficiency was present in 21%. The acetabular component was accurately placed, centralizing the prosthetic joint's rotation. Complications occurred in 16% of cases, including fractures, nerve issues, and infection. DAA in THA showcased positive outcomes for hip function, limb length, and biomechanics in Crowe IV dysplasia. Conclusions: the technique enabled accurate cup positioning and rotation center adjustment. Complications were managed well without implant revisions. DAA is a viable option for Crowe IV dysplasia, restoring hip function, biomechanics, and reducing limb length discrepancy. Larger, longer studies are needed for validation.


Assuntos
Artroplastia de Quadril , Humanos , Estudos Retrospectivos , Radiografia , Acetábulo , Músculo Esquelético
8.
Eur J Orthop Surg Traumatol ; 34(4): 1901-1910, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38456943

RESUMO

The aim of the present review is to systematically analyse the current literature about gender differences in hip or knee cartilage composition and degeneration, to help explaining how and why osteoarthritis affects women more often and more severely than men. A systematic review of the literature in English was performed. Eleven studies on 1962 patients (905 females and 787 males) that reported differences on cartilage composition between males and females were included. Nine evaluated the knee, one the hip, and one both. They were heterogeneous in their methods: one conducted histological analyses, and all the others evaluated cartilage characteristics (volume, width, and composition) through magnetic resonance imaging. All authors reported gender differences in both volume and morphology of the cartilage, from infancy to menopause. In fact, a study on 92 healthy children statistically showed significant gender differences in cartilage thickness at all sites, even after adjustment for age, body, and bone size. Gender differences become more evident after menopause, when women have a lower cartilage volume and a higher cartilage loss. Men show significantly higher knee and hip cartilage volumes than women, and women carry a significantly greater risk to develop osteoarthritis. This is in part due to body and bone size, but also depends on qualitative and quantitative differences in the composition of cartilage and its degeneration rate after menopause. Structural changes in cartilage that occur between genders during ageing have significance in the development of osteoarthritis.


Assuntos
Cartilagem Articular , Osteoartrite do Quadril , Osteoartrite do Joelho , Humanos , Cartilagem Articular/patologia , Cartilagem Articular/diagnóstico por imagem , Feminino , Masculino , Osteoartrite do Quadril/patologia , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/diagnóstico por imagem , Fatores Sexuais , Imageamento por Ressonância Magnética , Articulação do Joelho/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Pessoa de Meia-Idade , Adulto , Idoso , Criança
9.
Calcif Tissue Int ; 112(6): 666-674, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36949181

RESUMO

Over the last decade, evidence has mounted for a prominent etiologic role of femoroacetabular impingement (FAI) in the development of early hip osteoarthritis (OA). The aim of this study was to compare the ultrastructure and tissue composition of the hip labrum in healthy and pathological conditions, as FAI and OA, to provide understanding of structural changes which might be helpful in the future to design targeted therapies and improve treatment indications. We analyzed labral tissue samples from five healthy multi-organ donors (MCDs) (median age, 38 years), five FAI patients (median age, 37 years) and five late-stage OA patients undergoing total hip replacement (median age, 56 years). We evaluated morpho-functional by histology and transmission electron microscopy. Extracellular matrix (ECM) structure changes were similar in specimens from FAI compared to those from patients with OA (more severe in the latter) showing disorganization of collagen fibers and increased proteoglycan content. In FAI and in OA nuclei the chromatin was condensed, organelle degenerated and cytoplasm vacuolized. Areas of calcification were mainly observed in FAI and OA labrum, as well as apoptotic-like features. We showed that labral tissue of patients with FAI had similar pathological alterations of tissue obtained from OA patients, suggesting that FAI patients might have high susceptibility to develop OA.


Assuntos
Artroplastia de Quadril , Calcinose , Impacto Femoroacetabular , Osteoartrite do Quadril , Humanos , Adulto , Pessoa de Meia-Idade , Impacto Femoroacetabular/patologia , Impacto Femoroacetabular/cirurgia , Osteoartrite do Quadril/patologia , Artroplastia de Quadril/efeitos adversos , Calcinose/complicações , Matriz Extracelular/patologia , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia
10.
J Arthroplasty ; 38(6): 1184-1193.e2, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36592824

RESUMO

BACKGROUND: Much debate continues regarding the risk of postoperative infection after intra-articular corticosteroid injection prior to total joint arthroplasty. The aim of this study was to evaluate the risk of periprosthetic joint infection (PJI) or other complications after joint arthroplasty in patients who received preoperative corticosteroids injections. METHODS: A literature search was performed on PubMed, Web of Science, and Cochrane Library through January 4, 2022. Of 4,596 studies, 28 studies on 480,532 patients were selected for qualitative analysis. Studies describing patients receiving corticosteroids injections before joint arthroplasty (hip, knee) were included in the systematic review. A meta-analysis was performed of studies focusing on corticosteroids injections and PJI. Assessment of risk of bias and quality of evidence was based on the "Downs and Black's Checklist for Measuring Quality". RESULTS: A significant association (odds ratio: 1.55, P = .001, 95% confidence interval: 1.357-1.772) between PJI and corticosteroids injections was found for total hip arthroplasty (THA). No association was found for knee arthroplasty procedures. The risk of PJI is statistically higher (odds ratio: 1.20, P = .045, 95% confidence interval: 1.058-1.347) if the injections are performed within 3 months preoperatively in THA patients. CONCLUSION: Patients undergoing THA who previously received intra-articular injections of corticosteroids may expect a statistically higher risk of developing PJI. On the contrary, no association between corticosteroids injections and PJI could be seen in total knee arthroplasty patients. In addition, injection timing plays an important role: surgeons should refrain from administering corticosteroids injections within 3 months before hip arthroplasty, as it appears to be less safe than waiting a 3-month interval.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/complicações , Estudos Retrospectivos , Corticosteroides/efeitos adversos , Injeções Intra-Articulares/efeitos adversos , Artrite Infecciosa/etiologia
11.
J Arthroplasty ; 38(8): 1578-1583, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36764407

RESUMO

BACKGROUND: Five- to 10-year outcomes of a modular head-neck adapter system with ceramic heads in revision hip arthroplasty on large populations are still lacking. A registry study about modular adapter system with Delta ceramic head in revisions was designed, aiming to assess (1) the survival rates of the device, (2) the reasons for re-revisions of the device, and (3) a comparison to factory assembled titanium sleeve and Delta head cohort in revision hips. METHODS: Using a regional arthroplasty registry, we investigated the modular adapter system with a ceramic head in revision hips. Demographics, implant features, and reasons for revision were recorded. Survival rates and reasons for re-revision were assessed. The modular adapter system with the ceramic ball was compared to a factory-assembled ceramic titanium-sleeved head in revisions, acting as a control group. There were 354 revisions included at a mean follow-up of 5 years (range, 0 to 13). RESULTS: The 5- and 7-year survival rates were 87.9% and 86.9%, respectively. Dislocations (2.8%) and cup aseptic loosening (4.2%) were the 2 most frequent reasons for re-revision. No breakage of the adapter system or the ceramic head occurred. A femoral neck failed (0.3%). No implant features, offset (P = .088) or skirted (P = .870) tapers, impacted on failures. No differences between the 2 cohorts were found regarding survival rates (P = .696) and reasons for re-revision (dislocations, P = .983; cup aseptic loosening, P = .296). CONCLUSION: The modular head neck adapter system with a ceramic head seems to be a valid option in revisions at 5 and 7 years, without additional risk of implant breakage in this registry.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Titânio , Falha de Prótese , Desenho de Prótese , Reoperação , Sistema de Registros , Cerâmica
12.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36772674

RESUMO

BACKGROUND: Dynamic balance plays a key role in high-impact sports, such as CrossFit, where athletes are required to maintain balance in various weightlifting exercises. The loss of balance in these sport-specific movements may not only affect athlete performance, but also increase the risk of injuries. OBJECTIVES: The aim of the study is to achieve greater insight into the balance and athlete position during the CrossFit training by means of inertial sensors, with a particular focus on the role of different custom foot orthoses (CFOs) in order to detect correlations with the role of the cavus foot. METHODS: A total of 42 CrossFit® athletes, aged 25 to 42 years, were enrolled in this study. One-way ANOVA tests with post-hoc analysis of variance were used to compare foot posture groups and effects of different types of customized foot orthoses. RESULTS: When comparing the effects of CFOs with the respective balance basal level during the pistol squat exercise, we observed a significant (p = 0.0001) decrease in the sway area, antero-posterior displacement (APD) and medio-lateral displacement (MLD) compared to the basal using both types of CFOs. CONCLUSION: No significant positive effects of CFOs were observed in some static tests. On the contrary, positive effects of CFOs and, in particular, postural insoles, are relevant to dynamic balance.


Assuntos
Órtoses do Pé , Dispositivos Eletrônicos Vestíveis , Humanos , Equilíbrio Postural , , Movimento
13.
Int Orthop ; 47(3): 641-645, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36637462

RESUMO

PURPOSE: Computer-assisted arthroplasty supports the surgeons in planning, simulating, and performing the replacement procedure, using robotic or navigation technologies. However, the safety of the technology has not been widely ascertained. Food and Drug Administration (FDA) database was interrogated about software-related recalls in computer-assisted arthroplasty, aiming to assess: (1) the incidence, (2) the root causes, and (3) the actions taken due to recalls. METHODS: The Medical Device Recalls database was investigated about software-related recalls in computer-assisted hip and knee arthroplasty surgery, between 2017 and 2022. The incidence of the software-related recalls, the root causes according to FDA and manufacturers, and the corrective actions taken by firms were determined. RESULTS: Eighteen recall numbers could be identified (1.6%), corresponding to 11 recall events. A total of 4634 units were involved. The FDA determined root causes were: software design (66.6%), design change (22.2%), manufacturing deployment (1, 5.6%), and design manufacturing process (5.6%). Among the manufacturers' reasons for recalls, a specific error was declared in 16 cases (88.9%). In seven cases (43.8%), a coding error about lower limb alignment assessment was identified. Seventeen software-related recalls (94.4%) were classified as class 2; only one case was class 3 (5.6%). Return of the device was the main action taken by firms (8, 44.4%), followed by software update (7, 38.9%). CONCLUSION: Software-related recalls in computer-assisted hip and knee arthroplasty were quite uncommon among all the recalls, deemed non-life threatening and usually due to software design errors. The main actions taken by manufacturers were the return of the device or the software update.


Assuntos
Artroplastia do Joelho , Robótica , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/efeitos adversos , Software , Recall de Dispositivo Médico , Computadores
14.
Arch Orthop Trauma Surg ; 143(9): 5909-5918, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36764965

RESUMO

INTRODUCTION: The current strategy for modular neck failures in total hip arthroplasty (THA) is calibrated on CrCo neck failures. Stem revision is usually required, but the procedure is challenging and achieves modest outcomes (up to 20% of re-revisions at short-term). No study reports revision strategies and outcomes after Ti neck failures. Aims of the study were to evaluate: (1) demographic and implant features of the cohort to be revised, (2) intra-operative findings and surgical revision strategies and (3) clinical and radiological post-revision outcomes. MATERIALS AND METHODS: Hospital database was enquired about revisions due to Ti neck failures in primary THAs. Sixty-five revisions were enrolled (all with the same modular system). Neck exchange was attempted as the first-line treatment. Patients were clinically and radiographically evaluated after revision. RESULTS: The revision cohort encompassed fatigue neck fractures occurred 4.4 ± 2.6 years after THA: patients < 65 years and/or > 80 kg (98.5%) were predominant. Fifty-three neck exchanges were performed (81.5%). Eleven failures required stem revisions (16.9%), generally due to demanding neck extraction. Six complications occurred after neck exchange (11.3%), among them 2 acute infections requiring surgery (3.8%). Among stem revisions, one aseptic loosening and one neck re-fracture (18.5%) required re-revisions. At a mean follow-up of 7.1 ± 4 years, the neck exchange cohort achieved a mean HHS of 89.1 ± 6.3 (stem revisions: 84.1 ± 10.9). CONCLUSIONS: Revisions for Ti neck failures were predominantly performed due to fatigue fractures. In case of failures, neck exchange is a feasible procedure in most of the cases, with good outcomes at 7 years. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Titânio , Estudos Retrospectivos , Desenho de Prótese , Reoperação , Falha de Prótese , Resultado do Tratamento , Seguimentos
15.
Arch Orthop Trauma Surg ; 143(10): 6315-6321, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37261480

RESUMO

INTRODUCTION: The role of secondary patellar resurfacing (SPR) in anterior knee pain (AKP) is still debated in literature. A regional arthroplasty registry was investigated, aiming to: (1) assess the survival rate of SPR; and (2) compare SPR to tricompartmental TKA. MATERIALS AND METHODS: The regional arthroplasty registry RIPO was investigated about all SPRs performed after bicompartmental arthroplasty. The survival rates and the reasons for revision were assessed as any other factor that could have influenced implants failure. SPR survivorship was compared to tricompartmental TKAs. RESULTS: 406 SPRs performed after bicompartmental arthroplasty were analyzed. The survival rates were 80.6% (CI 95% 75.9-84.5) at 5 years and 77.6% (CI 95% 72.4-82) at 7 years. Half of the SPRs was performed 0.9-2.4 years after the index bicompartmental arthroplasty. SPR achieved lower survival than tricompartmental TKA (80.6% vs 96.7%, p < 0.001), with an adjusted hazard ratio for failure of 5.5 (CI 95% 4.2-7.1, p < 0.001). SPRs performed within 2 years after primary implant had a significantly higher rates of failure when compared to tricompartmental TKA (HR: 6.4, CI 95% 4.8-8.4, p < 0.001). CONCLUSION: SPR after bicompartmental knee arthroplasty showed modest 5- and 7-year survival rates, worse than primary tricompartmental TKA. When SPRs are performed within 2 years after primary arthroplasty, a significant higher risk of failure should be expected, highlighting than appropriate pre-operative work-up and patient selection is crucial for SPR successful outcome. LEVEL OF EVIDENCE: III, therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Resultado do Tratamento , Articulação do Joelho/cirurgia , Patela/cirurgia , Reoperação , Osteoartrite do Joelho/cirurgia
16.
Med Princ Pract ; 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37729888

RESUMO

OBJECTIVE: The purpose of this systematic review is to assess clinical and radiographic outcomes, complications rates, rates and reasons of re-revision of isolated femoral or tibial component revisions, comparing them with total knee revisions. METHODS: A review of the published literature was performed using Medline, Embase and Cochrane libraries. The terms "isolate" and "revision" and "knee arthroplasty" or "knee replacement" were together used as MESH terms. Partial knee replacement, non-English literature, case reports and papers published before 2000 were excluded. RESULTS: Out of 911 papers, six papers met the inclusion criteria. Mean MINORS scores achieved quite low values (13.33 and 13.67). No study encompassed revisions for septic loosening or infection. Total revisions performed for instability and wear achieved better clinical outcomes: in the other cases, partial and total revisions showed no differences in clinical outcomes. Both the cohorts showed similar radiographic features. Lesser bleeding and shorter operative times were observed in partial revisions compared to total revisions. The re-revision rates were similar in most of comparative studies: only one study noticed a significant difference in the failure rate between partial (25% at 3 years) and full (7% at 3.5 years) revisions. CONCLUSIONS: The poor quality of the studies precluded sound conclusions. Isolated tibial or femoral component revision is an option when the other component is well-fixed and positioned and in absence of chronic periprosthetic infection; nevertheless, it should be carefully evaluated when the reasons for revision are wear or instability.

17.
J Orthop Traumatol ; 24(1): 5, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725766

RESUMO

BACKGROUND: In total hip arthroplasty (THA), the outcomes of single taper (ST) and dual taper (DT) versions of the same stem design have been scarcely studied. A registry study comparing ST and DT versions of the same stem design was designed, aiming to assess: (1) the survival rates and the hazard ratios for failure; (2) the survival rates and the hazard ratios for failure using stem-focused endpoints. MATERIAL AND METHODS: A regional arthroplasty registry was interrogated about stem designs with ST and DT versions in cementless THAs performed for primary osteoarthritis. Only the same cup and ceramic-on-ceramic bearings were included: the DT stems had a titanium-on-titanium modularity. Demographic and implant features were recorded. Survival rates and hazard ratios were evaluated and compared. Stem-focused endpoints were also investigated. RESULTS: A total of 5359 THAs were included, with three stem designs. The two versions of every stem showed different demographics and implant-related features: ST versions were preferentially implanted in heavier young men. For each stem, the two versions had similar survival rates at 5 years (p = 0.076; p = 0.319; p = 0.616) and similar adjusted hazard ratios for failures (p = 0.084; p = 0.308; p = 0.729). When stem-focused endpoints were adopted, the ST and DT versions of the three stems achieved similar survival rates (p = 0.710; p = 0.784; p = 0.983) and similar adjusted hazard ratios (p = 0.647; p = 0.858; p = 0.787). Three neck breakages occurred (0.0007% of all the modular implants). CONCLUSIONS: ST and DT versions of the same stem design did not show any differences in terms of survival rates and hazard ratios for failures at 5 years. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite , Masculino , Humanos , Titânio , Falha de Prótese , Desenho de Prótese , Reoperação
18.
Arch Orthop Trauma Surg ; 142(12): 3965-3973, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35083520

RESUMO

INTRODUCTION: Condylar constrained knee arthroplasties (CCKAs) and rotating hinge knee arthroplasties (RHKAs) achieved good outcomes in complex primary total knee arthroplasties (TKAs); however, long-term comparative studies are few. Using an arthroplasty registry, we sought to assess and compare in CCKAs and RHKAs: (1) the intra-operative rates of complications, (2) the survival rates, (3) the reasons for revision, and (4) the adjusted hazard ratios for failure. MATERIALS AND METHODS: 1432 constrained implants in primary TKAs performed for non-oncological indications were included: 703 RHKAs, 729 CCKAs. The two groups were comparable regarding age and gender. Kaplan-Meier curves were used to compare survival rates, multivariate analyses to assess the hazard ratios for failures. RESULTS: The mean follow-up was 4.1 years (range 0-16.3) for CCKAs and 6.8 years (0-18.1) for RHKAs. The intra/peri-operative complications were similar in both the cohorts, with similar rates of femoral and tibial fractures. 10-year implant survival rates were similar in both the cohorts (91.9%, CI 95% 89.2-93.9% in RHKAs; 93.4%, CI 95% 90.3-95.6% in CCKAs). Periprosthetic infection was the most common reason for revision in the two cohorts, followed by aseptic loosening. Breakage occurred in 3 RHKAs (0.4%). CCKAs and RHKAs had a similar distribution of revision causes. Males aged less than 60 had significantly more failures, regardless the constraint degree. Unstemmed CCKAs significantly failed more than RHKAs and stemmed CCKAs. CONCLUSIONS: Both modern CCKAs and RHKAs are viable long-term solutions in complex primary TKAs. More failures should be expected in males aged less than 60. LEVEL OF EVIDENCE: IV, Therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Masculino , Humanos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Desenho de Prótese , Reoperação/efeitos adversos , Falha de Prótese , Resultado do Tratamento , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Seguimentos
19.
J Orthop Traumatol ; 23(1): 33, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35840842

RESUMO

BACKGROUND: Stem choice in total hip arthroplasty (THA) for hip dysplasia is still controversial. The aims of the study were to evaluate (1) which stem design provided the highest percentage of adequate reconstructions in THA for dysplasia and (2) any correlation between the reconstructions provided by the stems and the native femoral morphology. MATERIALS AND METHODS: 150 CT scans including 200 adult dysplastic hips were randomly selected. Using the 3D CT-based software Hip-Op for surgical planning, the native hip anatomy was studied. Then, a single wedge tapered stem, an anatomical stem and a conical tapered stem were simulated in every hip. An adequate reconstruction of hip biomechanics was obtained when combined anteversion, offset restoration, coronal and sagittal tilt, canal filling and leg lengthening were inside the normal ranges. RESULTS: Conical stems achieved the highest percentage of adequate reconstructions (87%, p < 0.0001). The anatomical stem was the worst performer. Single wedge and anatomical stem acceptability was mainly influenced by the combined anteversion. Stem anteversion was correlated with the femoral anteversion (fair correlation), the calcar femorale (fair) and the mediolateral femoral diameter at isthmus (poor). When the femoral anteversion was ≥ 25°, combined anteversion was very acceptable for the conical stem (99.2%), whereas the rate of acceptable combined anteversion for the single wedge tapered stem was 71.4%, and that for the anatomical stem was 51.6% (p < 0.0001). CONCLUSIONS: Stem choice in developmental hip dysplasia is mainly driven by appropriate combined anteversion, which is dependent on the coronal and axial femoral morphologies. As a rule of thumb, tapered stems are adequate when femoral anteversion is < 25°; conical stems should be adopted for higher anteversions. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Adulto , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Humanos , Estudos Retrospectivos , Software , Tomografia Computadorizada por Raios X
20.
Skeletal Radiol ; 50(9): 1775-1779, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33532940

RESUMO

OBJECTIVE: Stem anteversion in total hip arthroplasty (THA) has been measured using two different distal references, the posterior condyle (PC) or the transepicondylar axis (TEA). The reliability, the difference in value between these two techniques, and the possible confounding factors are scarcely known. Aims of this work were to assess (1) the intraclass correlation and the difference between the two measurement techniques and (2) the possible influence of condylar dysmorphisms on the anteversion value discrepancy. MATERIALS AND METHODS: A consecutive series of post-THA CT scans were selected, excluding hip dysplasia, end-stage knee osteoarthritis, and replaced knees. Using a surgical planning software, stem anteversion was measured using the PC or the TEA reference. The intraclass reliability was assessed. The anteroposterior femoral condyle diameters were measured: the difference and the ratio were measured and correlated with the stem anteversion values. RESULTS: 91 CT scans were included. Inter/intra-observer TEA measurements were more reliable than PC. The intraclass correlation between PC and TEA anteversion measurements was good, 0.954 (CI 95% 0.922-0965). The mean difference between PC and TEA anteversion was 5.27 ± 2.41°. The difference and the ratio between the two anteroposterior condyle diameters did not influence the anteversion difference (respectively, p 0.797 and p 0.901). CONCLUSIONS: TEA and PC demonstrated to achieve a good correlation, not dependent from the condyle morphology. However, the difference between the two measurements (5°) can severely influence the combined anteversion (10-20%): due to clinical applicability and better inter/intra-observer agreement, TEA should be preferred for measuring stem anteversion.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Osteoartrite do Joelho/cirurgia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa