Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
BMC Pediatr ; 24(1): 509, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118070

RESUMO

OBJECTIVE: To determine the effectiveness of phase-change-material mattress (PCM) during transportation of newborns with hypoxic ischemic encephalopathy (HIE). STUDY DESIGN: Randomized controlled trial of newborns with HIE from June 2016 to December 2019. Patients were randomized to transport with PCM or without PCM (control) when transferred to a cooling center in northern Vietnam. Primary outcome measure was mortality rate, secondary outcomes including temperature control and adverse effects. RESULT: Fifty-Two patients in PCM-group and 61 in control group. Median rectal temperature upon arrival was 34.5 °C (IQR 33.5-34.8) in PCM-group and 35.1 °C (IQR 34.5-35.9) in control group (p = 0.023). Median time from birth to reach target temperature was 5.0 ± 1.4 h and 5.5 ± 1.2 h in the respective groups (p = 0.065). 81% of those transported with PCM versus 62% of infants transported without (p = 0.049) had reached target temperature within the 6-h timeframe. There was no record of overcooling (< 32 °C) in any of the groups. The was no difference in mortality rate between the two groups (33% and 34% respectively (p > 0.05)). CONCLUSION: Phase-change-material can be used as a safe and effective cooling method during transportation of newborns with HIE in low-resource settings. TRIAL REGISTRATION: The study was retro-prospectively registered in Clinical Trials (04/05/2022, NCT05361473).


Assuntos
Leitos , Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Transporte de Pacientes , Humanos , Hipóxia-Isquemia Encefálica/terapia , Hipóxia-Isquemia Encefálica/mortalidade , Recém-Nascido , Vietnã , Hipotermia Induzida/métodos , Feminino , Transporte de Pacientes/métodos , Masculino , Temperatura Corporal
2.
J Environ Manage ; 329: 117078, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36571949

RESUMO

Membrane capacitive deionization (MCDI) has shown many advances, however, its performance in combination with other treatment technologies has not been widely reported. In this study, a pilot-scale low-pressure reverse osmosis (LPRO) (FilmTec™ XLE-2540) with MCDI (CapDI© C17, Voltea) was developed and tested as a promising modular desalination system. The systems were evaluated individually at different salinities and tested together as a modular system. The study focused in the comparison to conventional seawater reverse osmosis (SWRO) (FilmTec™ SW30-2540) at pilot-scale and in theory using the software Water Application Value Engine (WAVE, DuPont™), including a cost evaluation of the systems. Pilot tests were carried out in Can Gio, a riverine estuary region in South Vietnam, which is affected by progressive salinization (TDS ≈ 1-25 g/L). Drinking water quality (TDS < 600 mg/L) was achieved with a specific energy consumption (SEC) of 5.2 kWh/m³. Additionally, fouling mitigation was investigated for the ultrafiltration (UF) pre-treatment by periodic hydraulic and chemical enhanced backwashing. While the SWRO had a slightly lower SEC of 5.0 kWh/m³, WAVE calculations showed that lowering the SEC to 3.6 kWh/m³ is possible by improving the LPRO pump design and an optimization of the MCDI operation.


Assuntos
Purificação da Água , Vietnã , Osmose , Membranas Artificiais , Água do Mar
3.
BMC Cancer ; 22(1): 702, 2022 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-35752785

RESUMO

BACKGROUND: Axillary lymph node (LN) metastasis is one of the most important predictors of recurrence and survival in breast cancer, and accurate assessment of LN involvement is crucial. Determining extent of residual disease is key for surgical planning after neoadjuvant therapy. The aim of the study was to evaluate the diagnostic reliability of MRI for nodal disease in locally advanced breast cancer patients treated with neoadjuvant endocrine therapy (NET). METHODS: Thirty-three clinically node-positive locally advanced breast cancer patients who underwent NET and surgery were prospectively enrolled. Two radiologists reviewed the axillary nodes at 3 separate time points MRI examinations at baseline (before the first treatment regimen), interim (following at least 2 months after the first cycle and prior to crossing-over), and preoperative (after the final administration of therapy and immediately before surgery). According to LN status after surgery, imaging features and diagnostic performance were analyzed. RESULTS: All 33 patients had a target LN reduction, the greatest treatment benefit from week 8 to week 16. There was a positive correlation between the maximal diameter of the most suspicious LN measured by MRI and pathology during and after NET, being highest at therapy completion (r = 0.6, P ≤ .001). Mean and median differences of maximal diameter of the most suspicious LN were higher with MRI than with pathology. Seven of 33 patients demonstrated normal posttreatment MRI nodal status (yrN0). Of these 7 yrN0, 3 exhibited no metastasis on final pathology (ypN0), 2 ypN1 and 2 ypN2. Reciprocally, MRI diagnosed 3 cases of ypN0 as yrN + . Diffusion -weighted imaging (DWI) was the only axillary node characteristic significant when associated with pathological node status (χ2(4) = 8.118, P = .072). CONCLUSION: Performance characteristics of MRI were not completely sufficient to preclude surgical axillary staging. To our knowledge, this is the first study on MRI LN assessment following NET in locally advanced breast cancer, and further studies with larger sample sizes are required to consolidate the results of this preliminary study. TRIAL REGISTRATION: Institutional Review Board approval was obtained (this current manuscript is from a prospective, open-label, randomized single-center cohort substudy of the NEOLETEXE trial). NEOLETEXE, a phase 2 clinical trial, was registered on March 23rd, 2015 in the National trial database of Norway and approved by the Regional Ethical Committee of the South-Eastern Health Region in Norway; registration number: REK-SØ-84-2015 .


Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Axila/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Efeitos Psicossociais da Doença , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/patologia , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Estudos Prospectivos , Reprodutibilidade dos Testes , Biópsia de Linfonodo Sentinela
4.
Acta Paediatr ; 110(1): 85-93, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32347576

RESUMO

AIM: To evaluate whether phase-changing material can be used for therapeutic hypothermia of asphyxiated newborns in low-resource settings. METHODS: Prospective interventional study of asphyxiated term infants fulfilling criteria for hypothermia treatment at Vietnam National Children's Hospital from September 2014 to September 2016. Hypothermia was induced within 6 hours after birth and maintained for 72 hours by a phase-changing material mattress with melting point of 32°C. Rectal temperature was continuously measured, and deviations from target temperature range 33.5-34.5°C were recorded. RESULTS: In total 52 infants (mean gestational age 39.3 ± 1.1 weeks) included and cooled, the median temperature at initiation of cooling was 35.3 (IQR 34.5-35.9)°C. The median time to reach target temperature was 2.5 (IQR 2-3) hours. The mean temperature during the cooling phase was 33.95 ± 0.2°C. Throughout the cooling phase, the target temperature range (33.5-34.5°C) was maintained more than 80% of the time. Rate of rewarming was 0.5 ± 0.14°C/hour. CONCLUSION: Phase-changing material can be used as an effective cooling method. Though not a servo-controlled system, it is easy to induce hypothermia, maintain target temperature and rewarm infants in a slow and controlled manner without need for frequent changes and minimum risk of skin injury.


Assuntos
Asfixia Neonatal , Hipotermia Induzida , Hipotermia , Hipóxia-Isquemia Encefálica , Asfixia , Asfixia Neonatal/terapia , Temperatura Corporal , Criança , Humanos , Hipóxia-Isquemia Encefálica/terapia , Lactente , Recém-Nascido , Estudos Prospectivos , Vietnã
5.
J Air Waste Manag Assoc ; 74(7): 478-489, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38916528

RESUMO

This study partially replaced the clay with sewer sludge (SS) and rice husk (RH-SS) to make fired bricks. The brick samples were examed in terms of shrinkage, water absorption, and compressive strength. Besides, they were analyzed via XRD and metal extraction to determine the heavy metal residuals in the products. The results showed that it was possible to fabricate fired bricks using sewer sludge or rice husk-blended sludge with up to 30% by weight. These brick samples complied with the technical standard for clay brick production, in which the compressive strength was more than 7.5 MPa, water absorption was from 11-16%, and the linear shrinkage was all less than 5%. The rice husk addition helped mitigate the heavy metal residuals in the bricks and leaching liquid, in which all the values were lower than the US-EPA maximum concentration of contaminants for toxicity characteristics.Implications: Previous studies have proved the possibility of mixing sewage sludge from different origins (sewage sludge, river sediment, canal sediment, sewer sediment, etc.) with clay and some wastes to make bricks. In which, mostof the studies used sewage sludge from wastewater treatment plants, very fewdealt with lake/river or sewer sediment. This study shall be the first to study the possibility of employing sewer sediments with the addition of rice husk powder to achieve two targets, including (1) the reuse of biowaste and sludge for brick fabrication and (2) the reduction of heavy metals in final calcined bricks. Different ratios of the rice-husk blended sewer sludge (RH-SS) - clay mixture shall be tested to find the optimized compositions. The results showed that it was possible to fabricate fired bricks using sewer sludge or rice husk-blended sludge with up to 30% by weight, which meant reduce 30% of clay in the brick production. The final products were proved to meet the quality standard in terms of compressive strength (more than 10 MPa), water absorption(from 11-16%), and the linear shrinkage (less than 5%). Larger scale of this study can be an evident to recommend for policy change in the waste reuse in construction field.


Assuntos
Materiais de Construção , Esgotos , Esgotos/análise , Esgotos/química , Materiais de Construção/análise , Metais Pesados/análise , Reciclagem/métodos , Oryza
6.
Int J Stroke ; 19(3): 305-313, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37807200

RESUMO

INTRODUCTION: Endovascular treatment for acute ischemic stroke patients with large vessel occlusion (LVO) has been established as a promising clinical intervention within a late time window of 6-24 h after symptom onset. Patients with slow progression, however, may still benefit from endovascular treatment beyond the 24-h time window (very late window). AIM: The aim of this study is to report insight into the potential clinical benefits of endovascular treatment for acute ischemic stroke beyond 24 h from symptom onset. METHODS: A retrospective analysis was performed on consecutive patients undergoing endovascular treatment for acute anterior circulation LVO ischemic stroke beyond 24 h. Participants were recruited between July 2019 and November 2020. Patients were selected based on the DAWN/DEFUSE 3 criteria (Perfusion-RAPID, iSchemaView) and patients receiving treatment beyond 24 h were compared to a group of patients receiving endovascular treatment between 6 and 24 h after symptom onset. The primary outcome was the proportion of patients with functional independence at 90 days (modified Rankin Scale score of 0-2). The secondary outcomes were shift modified Rankin Scale (mRS) analysis and successful reperfusion was defined by thrombolysis in cerebral infarction (TICI) 2b-3 on the final procedure. Safety outcomes were symptomatic intracranial hemorrhage and death at the 90-day follow-up. Propensity score (PS)-matched analyses were employed to rectify the imbalanced baseline characteristics between the two groups. RESULTS: A total of 166 patients were recruited with a median age of 63.0 (56.0-69.0) and 28.9% of all patients were females. Patients in the beyond 24-h group had a longer onset-to-groin time (median = 27.2 vs 14.3 h, p < 0.001) than those in the 6- to 24-h group. There were no statistically significant differences between the two groups in National Institutes of Health Stroke Scale (NIHSS) (median = 12.0 vs 15.0, p = 0.37), perfusion imaging characteristics (core: median = 11.0 vs 9.0 mL, p = 0.86; mismatch volume: median = 106.0 vs 96.0, p = 0.44; mismatch ratio = 6.46 vs 7.24, p = 0.91), and perfusion-to-groin time (median = 72.5 vs 76.0 min, p = 0.77). No significant differences were noted among patients between the two groups in the primary endpoint functional independence analysis (50.0% vs 46.6%, p = 0.77) and in the safety endpoint analysis: mortality (15.0% vs 11.0%, p = 0.71) or symptomatic hemorrhage (0% vs 3.42%, p > 0.999). In PS-matched analyses, there were no significant differences among patients between the two groups in functional independence (50.0% vs 54.8%, p = 0.74), mortality (16.7% vs 9.68%, p = 0.50), or symptomatic hemorrhage (0% vs 6.45%, p = 0.53). CONCLUSION: Endovascular treatment can be performed safely and effectively in LVO patients beyond 24 h from symptom onset when selected by target mismatch profile. The clinical outcome of these patients was comparable to those treated in the 6- to 24-h window. Larger studies are needed to confirm these findings.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Feminino , Humanos , Masculino , AVC Isquêmico/etiologia , Acidente Vascular Cerebral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Hemorragias Intracranianas/etiologia , Trombectomia/métodos , Isquemia Encefálica/cirurgia , Isquemia Encefálica/etiologia
7.
Mycobiology ; 51(4): 246-255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37711987

RESUMO

Genus Penicillium comprising the most important and extensively studied fungi has been well-known as a rich source of secondary metabolites. Our study aimed to analyze and investigate biological activities, including in vitro anti-cancer, anti-inflammatory and anti-diabetic properties, of metabolites from a marine-derived fungus belonging to P. levitum. The chemical compounds in the culture broth of P. levitum strain N33.2 were extracted with ethyl acetate. Followingly, chemical analysis of the extract leaded to the isolation of three ergostane-type steroid components, namely cerevisterol (1), ergosterol peroxide (2), and (3ß,5α,22E)-ergosta-6,8(14),22-triene-3,5-diol (3). Among these, (3) was the most potent cytotoxic against human cancer cell lines Hep-G2, A549 and MCF-7 with IC50 values of 2.89, 18.51, and 16.47 µg/mL, respectively, while the compound (1) showed no significant effect against tested cancer cells. Anti-inflammatory properties of purified compounds were evaluated based on NO-production in LPS-induced murine RAW264.7 macrophages. As a result, tested compounds performed diverse inhibitory effects on NO production by the macrophages, with the most significant inhibition rate of 81.37 ± 1.35% at 25 µg/mL by the compound (2). Interestingly, compounds (2) and (3) exhibited inhibitory activities against pancreatic lipase and α-glucosidase enzymes in vitro assays. Our study brought out new data concerning the chemical properties and biological activities of isolated steroids from a P. levitum fungus.

8.
PLoS One ; 15(1): e0227837, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31940415

RESUMO

INTRODUCTION: Snus is an oral tobacco product that originated in Sweden. Snus products are available as fine-cut loose tobacco or in pre-portioned porous "pouches." Some snus products undergo tobacco pasteurization during manufacturing, a process that removes or reduces nitrite-forming microbes, resulting in less tobacco-specific nitrosamine content in the product. Some tobacco companies and researchers have suggested that snus is potentially less harmful than traditional tobacco and thus a potential smoking cessation aid or an alternative to continued cigarette consumption. Although snus is available in various countries, limited information exists on snus variants from different manufacturers. METHODS: Moisture, pH, nicotine, and tobacco-specific N'-nitrosamines (TSNAs) were quantified in 64 snus products made by 10 manufacturers in the United States and Northern Europe (NE). Reported means, standard errors, and differences are least-square (LS) estimates from bootstrapped mixed effects models, which accounted for correlation among repeated measurements. Minor alkaloids and select flavors were also measured. RESULTS: Among all product types, moisture (27.4%-59.5%), pH (pH 5.87-9.10), total nicotine (6.81-20.6 mg/g, wet), unprotonated nicotine (0.083-15.7 mg/g), and total TSNAs (390-4,910 ng/g) varied widely. The LS-mean unprotonated nicotine concentration of NE portion (7.72 mg/g, SE = 0.963) and NE loose (5.06 mg/g, SE = 1.26) snus were each significantly higher than US portion snus (1.00 mg/g, SE = 1.56). Concentrations of minor alkaloids varied most among products with the highest total nicotine levels. The LS-mean NNN+NNK were higher in snus sold in the US (1360 ng/g, SE = 207) than in NE (836 ng/g, SE = 132) countries. The most abundant flavor compounds detected were pulegone, eucalyptol, and menthol. CONCLUSION: Physical and chemical characteristics of US and NE products labeled as snus can vary considerably and should not be considered "equivalent". Our findings could inform public health and policy decisions pertaining to snus exposure and potential adverse health effects associated with snus.


Assuntos
Tabaco sem Fumaça/análise , Alcaloides/análise , Europa (Continente) , Aromatizantes/análise , Humanos , Concentração de Íons de Hidrogênio , Nicotina/análise , Nitrosaminas/análise , Estados Unidos
9.
Biomed Res Int ; 2019: 9757625, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31179337

RESUMO

Carbapenemase-producing Enterobacteriaceae (CPE) are well known to cause many serious infections resulting in increasing mortality rate, treatment cost, and prolonged hospitalization. Among the widely recognized types of carbapenemases, New Delhi ß-lactamase (NDM) and Klebsiella pneumoniae carbapenemase (KPC) are the most important enzymes. However, in Vietnam, there are only scattered reports of CPE due to the lack of simple and affordable methods that are suitable to laboratory conditions. This study aims to survey the characteristics of carbapenem-resistant E. coli and K. pneumoniae (CR-E/K) at two hospitals in Southern Vietnam and perform some simple methods to detect the two enzymes. A total of 100 CR-E/K strains were collected from clinical isolates of Gia Dinh People's Hospital and Dong Nai General Hospital, Vietnam, from November 2017 to May 2018. The patient-related information was also included in the analysis. We conducted real-time polymerase chain reaction (PCR), Modified Hodge Test (MHT), and combined disk test (CDT) on all isolates. Carbapenemase-encoding genes were detected in 47 isolates (36 NDM, 10 KPC, and one isolate harboring both genes). The E. coli strain carrying simultaneously these two genes was the first case reported here. Most of isolates were collected from patients in ICU, Infectious Disease Department, and Department of Urologic Surgery. Urine and sputum were two common specimens. The true positive rate (sensitivity, TPR) and specificity (SPC) of the imipenem-EDTA (ethylen diamine tetra acetic acid) for NDM detection and the imipenem-PBA (phenylboronic acid) for KPC detection on E. coli were 93.8%, 97.1% and 66.7%, 95.7%, respectively. Meanwhile, the imipenem-EDTA for NDM detection and the imipenem-PBA for KPC detection among K. pneumonia achieved 90.5%, 100% and 100%, 92.9% TPR and SPC, respectively. However, MHT showed low sensitivity and specificity. Our findings showed that CP-E/K were detected with high prevalence in the two hospitals. We suggest that CDT can be used as a low-priced and accurate method of detection.


Assuntos
Proteínas de Bactérias/genética , Infecções por Escherichia coli/genética , Escherichia coli , Infecções por Klebsiella/genética , Klebsiella pneumoniae , Reação em Cadeia da Polimerase , beta-Lactamases/genética , Estudos Transversais , Escherichia coli/enzimologia , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Infecções por Escherichia coli/enzimologia , Infecções por Escherichia coli/epidemiologia , Feminino , Humanos , Infecções por Klebsiella/enzimologia , Infecções por Klebsiella/epidemiologia , Klebsiella pneumoniae/enzimologia , Klebsiella pneumoniae/genética , Klebsiella pneumoniae/isolamento & purificação , Masculino , Vietnã/epidemiologia , beta-Lactamases/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa