RESUMO
Biotransformation leading to single residue modifications (e.g., deamidation, oxidation) can contribute to decreased efficacy/potency, poor pharmacokinetics, and/or toxicity/immunogenicity for protein therapeutics. Identifying and characterizing such liabilities in vivo are emerging needs for biologics drug discovery. In vitro stress assays involving PBS for deamidation or AAPH for oxidation are commonly used for predicting liabilities in manufacturing and storage and are sometimes considered a predictive tool for in vivo liabilities. However, reports discussing their in vivo translatability are limited. Herein, we introduce a mass spectrometry workflow that characterizes in vivo oxidation and deamidation in pharmacokinetically relevant compartments for diverse protein therapeutic modalities. The workflow has low bias of <10% in quantitating degradation in the relevant pharmacokinetic concentration range for monkey and rabbit serum/plasma (1-100 µg/mL) and allows for high sequence coverage (â¼85%) for discovery/monitoring of amino acid modifications. For oxidation and deamidation, the assay was precise, with percent coefficient of variation of <8% at 1-100 µg/mL and ≤6% method-induced artifacts. A high degree of in vitro and in vivo correlation was observed for deamidation on the six diverse protein therapeutics (seven liability sites) tested. In vivo translatability for oxidation liabilities were not observed for the 11 molecules tested using in vitro AAPH stress. One of the molecules dosed in eyes resulted in a false positive and a false negative prediction for in vivo oxidation following AAPH stress. Finally, peroxide stress was also tested but resulted in limited success (1 out of 4 molecules) in predicting oxidation liabilities.
Assuntos
Oxirredução , Animais , Coelhos , BiotransformaçãoRESUMO
Intact protein mass spectrometry (MS) coupled with liquid chromatography was applied to characterize the pharmacokinetics and stability profiles of therapeutic proteins. However, limitations from chromatography, including throughput and carryover, result in challenges with handling large sample numbers. Here, we combined intact protein MS with multiple front-end separations, including affinity capture, SampleStream, and high-field asymmetric waveform ion mobility spectrometry (FAIMS), to perform high-throughput and specific mass measurements of a multivalent antibody with one antigen-binding fragment (Fab) fused to an immunoglobulin G1 (IgG1) antibody. Generic affinity capture ensures the retention of both intact species 1Fab-IgG1 and the tentative degradation product IgG1. Subsequently, the analytes were directly loaded into SampleStream, where each injection occurs within â¼30 s. By separating ions prior to MS detection, FAIMS further offered improvement in signal-overnoise by â¼30% for denatured protein MS via employing compensation voltages that were optimized for different antibody species. When enhanced FAIMS transmission of 1Fab-IgG1 was employed, a qualified assay was established for spiked-in serum samples between 0.1 and 25 µg/mL, resulting in â¼10% accuracy bias and precision coefficient of variation. Selective FAIMS transmission of IgG1 as the degradation surrogate product enabled more sensitive detection of clipped species for intact 1Fab-IgG1 at 5 µg/mL in serum, generating an assay to measure 1Fab-IgG1 truncation between 2.5 and 50% with accuracy and precision below 20% bias and coefficient of variation. Our results revealed that the SampleStream-FAIMS-MS platform affords high throughput, selectivity, and sensitivity for characterizing therapeutic antibodies from complex biomatrices qualitatively and quantitatively.
Assuntos
Imunoglobulina G , Espectrometria de Mobilidade Iônica , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Cromatografia Líquida , Íons/químicaRESUMO
The growing opportunities recognized for covalent drug inhibitors, like KRAS G12C inhibitors, are driving the need for mass spectrometry methods that can quickly and robustly measure therapeutic drug activity in vivo for drug discovery research and development. Effective front-end sample preparation is critical for proteins extracted from tumors but is generally labor intensive and impractical for large sample numbers typical in pharmacodynamic (PD) studies. Herein, we describe an automated and integrated sample preparation method for the measurement of activity levels of KRAS G12C drug inhibitor alkylation from complex tumor samples involving high throughput detergent removal and preconcentration followed by quantitation using mass spectrometry. We introduce a robust assay with an average intra-assay coefficient of variation (CV) of 4% and an interassay CV of 6% obtained from seven studies, enabling us to understand the relationship between KRAS G12C target occupancy and the therapeutic PD effect from mouse tumor samples. Further, the data demonstrated that the drug candidate GDC-6036, a KRAS G12C covalent inhibitor, shows dose-dependent target inhibition (KRAS G12C alkylation) and MAPK pathway inhibition, which correlate with high antitumor potency in the MIA PaCa-2 pancreatic xenograft model.
Assuntos
Antineoplásicos , Proteínas Proto-Oncogênicas p21(ras) , Humanos , Animais , Camundongos , Proteínas Proto-Oncogênicas p21(ras)/genética , Linhagem Celular Tumoral , Mutação , Antineoplásicos/farmacologia , Modelos Animais de DoençasRESUMO
Toward the goal of increasing the throughput of high-resolution mass characterization of intact antibodies, we developed a RapidFire-mass spectrometry (MS) assay using electrospray ionization. We achieved unprecedented screening throughput as fast as 15 s/sample, which is an order of magnitude improvement over conventional liquid chromatography (LC)-MS approaches. The screening enabled intact mass determination as accurate as 7 ppm with baseline resolution at the glycoform level for intact antibodies. We utilized this assay to characterize and perform relative quantitation of antibody species from 248 samples of 62 different cell line clones at four time points in 2 h using RapidFire-time-of-flight MS screening. The screening enabled selection of clones with the highest purity of bispecific antibody production and the results significantly correlated with conventional LC-MS results. In addition, analyzing antibodies from a complex plasma sample using affinity-RapidFire-MS was also demonstrated and qualified. In summary, the platform affords high-throughput analyses of antibodies, including bispecific antibodies and potential mispaired side products, in cell culture media, or other complex matrices.
Assuntos
Anticorpos Biespecíficos/sangue , Anticorpos/sangue , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Anticorpos/isolamento & purificação , Anticorpos Biespecíficos/isolamento & purificação , Linhagem Celular , Cromatografia Líquida/métodos , HumanosRESUMO
KRAS is one of the most frequently mutated oncogenes, with KRAS G12C recently becoming an actionable target for small molecule intervention. GDC-6036 is an investigational KRAS G12C inhibitor that acts by irreversibly binding to the switch II pocket of KRAS G12C when in the inactive GDP-bound state, thereby blocking GTP binding and activation. Assessing target engagement is an essential component of clinical drug development, helping to demonstrate mechanistic activity, guide dose selection, understand pharmacodynamics as it relates to clinical response, and explore resistance. Here, we report the development of an ultra-sensitive approach for assessing KRAS G12C engagement. Immunoaffinity enrichment with a commercially available anti-RAS antibody was combined with a targeted 2D-LC-MS/MS technique to quantify both free and GDC-6036-bound KRAS G12C proteins. A KRAS G12C-positive non-small cell lung cancer xenograft model was dosed with GDC-6036 to assess the feasibility of this assay for analyzing small core needle biopsies. As predicted, dose-dependent KRAS G12C engagement was observed. To date, a sensitivity of 0.08 fmol/µg of total protein has been achieved for both free and GDC-6036-bound KRAS G12C with as little as 4 µg of total protein extracted from human tumor samples. This sub-fmol/µg level of sensitivity provides a powerful potential approach to assess covalent inhibitor target engagement at the site of action using core needle tumor biopsies from clinical studies.
Assuntos
Antineoplásicos , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Animais , Antineoplásicos/química , Biópsia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Cromatografia Líquida , Guanosina Trifosfato , Humanos , Neoplasias Pulmonares/patologia , Mutação , Proteínas Proto-Oncogênicas p21(ras)/genética , Proteínas Proto-Oncogênicas p21(ras)/metabolismo , Espectrometria de Massas em TandemRESUMO
Unlike with new chemical entities, the biotransformation of therapeutic proteins (TPs) has not been routinely investigated or included in regulatory filings. Nevertheless, there is an expanding pool of evidence suggesting that a more in-depth understanding of biotransformation could better aid the discovery and development of increasingly diverse modalities. For instance, such biotransformation analysis of TPs affords important information on molecular stability, which in turn may shed light on any potential impact on binding affinity, potency, pharmacokinetics, efficacy, safety, or bioanalysis. This perspective summarizes the current practices in studying biotransformation of TPs and related findings in the biopharmaceutical industry. Various TP case studies are discussed, and a fit-for-purpose approach is recommended when investigating their biotransformation. In addition, we provide a decision tree to guide the biotransformation characterization for selected modalities. By raising the awareness of this important topic, which remains relatively underexplored in the development of TPs (Bolleddula et al., 2022), we hope that current and developing practices can pave the way for establishing a consensus on the biotransformation assessment of TPs. SIGNIFICANCE STATEMENT: This article provides a comprehensive perspective of the current practices for exploring the biotransformation of therapeutic proteins across the drug development industry. We, the participants of the Innovation and Quality therapeutic protein absorption distribution metabolism excretion working group, recommend and summarize appropriate approaches for conducting biotransformation studies to support internal decision making based on the data generated in discovery and development.
Assuntos
Produtos Biológicos , Indústria Farmacêutica , Biotransformação , HumanosRESUMO
Proteases are critical proteins involved in cleaving substrates that may impact biological pathways, cellular processes, or disease progression. In the biopharmaceutical industry, modulating the levels of protease activity is an important strategy for mitigating many types of diseases. While a variety of analytical tools exist for characterizing substrate cleavages, in vitro functional screening for antibody inhibitors of protease activity using physiologically relevant intact protein substrates remains challenging. In addition, detecting such large protein substrates with high heterogeneity using high-throughput mass spectrometry screening has rarely been reported in the literature with concerns for assay robustness and sensitivity. In this study, we established a peptide-based in vitro functional screening assay for antibody inhibitors of mouse bone morphogenic protein 1 (mBMP1) metalloprotease using a heterogeneous recombinant 66-kDa mouse Procollagen I alpha 1 chain (mProcollagen) substrate. We compared several analytical tools including capillary gel electrophoresis Western blot (CE-Western blot), as well as both intact protein and peptide-based mass spectrometry (MS) to quantitate the mBMP1 proteolytic activity and its inhibition by antibodies using this heterogeneous mProcollagen substrate. We concluded that the peptide-based mass spectrometry screening assay was the most suitable approach in terms of throughput, sensitivity, and assay robustness. We then optimized our mBMP1 proteolysis reaction after characterizing the enzyme kinetics using the peptide-based MS assay. This assay resulted in Z' values ranging from 0.6 to 0.8 from the screening campaign. Among over 1200 antibodies screened, IC50 characterization was performed on the top candidate hits, which showed partial or complete inhibitory activities against mBMP1.
Assuntos
Peptídeos , Pró-Colágeno , Animais , Espectrometria de Massas , Camundongos , Peptídeo Hidrolases/metabolismo , Peptídeos/metabolismo , Pró-Colágeno/metabolismo , Proteínas/metabolismo , Proteólise , Especificidade por SubstratoRESUMO
There are many pharmacokinetic challenges associated with administering protein therapeutics, including biotransformation via clipping, deamidation, isomerization, oxidation, etc. In the case of engineered multivalent tethered antibody formats, proteolysis or deconjugation at the fusion or conjugation site present further issues. Unlike degradations associated with antibody drug conjugates, such biotransformations of tethered antibody formats usually result in degraded products with large mass differences. These large differences can result in processing or mass spectrometry response bias among the resulting product species that can lead to inaccurate stability quantitation. Herein, we describe an assay strategy for characterizing and quantitating degradations accurately for multivalent antibodies by incorporating response bias corrections. For the multivalent tethered antibody molecules selected, an â¼30-80% difference in response, compared to the cleaved product, was observed. To correct for the response bias, selected tethered multivalent antibodies and an IgG antibody (representing the stable intact and the degraded product species, respectively) were spiked in serum at known ratios for analysis. Following affinity capture, we generated calibration curves (five-parameter logistic fit p < 0.05) by plotting the measured ratios of the MS ion responses against the known spiked-in ratios (CVs < 8% for calibration standards). The qualified calibration curve (accuracy within 8% and 2% for measuring degradations of 5% and 15% product, respectively) was then used, through interpolation, to determine stability profiles for the same multivalent tethered antibody formats from both in vitro serum and pharmacokinetic study samples.
Assuntos
Anticorpos/análise , Imunoconjugados/análise , Cromatografia Líquida , Espectrometria de MassasRESUMO
With the rapid rise of therapeutic antibodies and antibody-drug conjugates, significant investments have been made in developing workflows that utilize mass spectrometry to detect these intact molecules, the large fragments generated by their selective digestion, and the peptides generated by traditional proteomics workflows. The resultant data is used to gain insight into a wide range of parameters, including primary sequence, disulfide bonding, glycosylation patterns, biotransformation, and more. However, many of the technologies utilized to couple these workflows to mass spectrometers have significant limitations that force nonoptimal modifications to upstream sample preparation steps, limit the throughput of high-volume workflows, and prevent the harmonization of diverse experiments onto a single hardware platform. Here, we describe a new analytical platform that enables direct and high-throughput coupling to electrospray ionization mass spectrometry. The SampleStream platform is compatible with both native and denaturing electrospray, operates with a throughput of up to 15 s/sample, provides extensive concentration of dilute samples, and affords similar sensitivity to comparable liquid chromatographic methods.
Assuntos
Anticorpos Monoclonais/análise , Ensaios de Triagem em Larga Escala , Imunoconjugados/análise , Ensaios de Triagem em Larga Escala/instrumentação , Software , Espectrometria de Massas por Ionização por Electrospray/instrumentaçãoRESUMO
A full description of the human proteome relies on the challenging task of detecting mature and changing forms of protein molecules in the body. Large-scale proteome analysis has routinely involved digesting intact proteins followed by inferred protein identification using mass spectrometry. This 'bottom-up' process affords a high number of identifications (not always unique to a single gene). However, complications arise from incomplete or ambiguous characterization of alternative splice forms, diverse modifications (for example, acetylation and methylation) and endogenous protein cleavages, especially when combinations of these create complex patterns of intact protein isoforms and species. 'Top-down' interrogation of whole proteins can overcome these problems for individual proteins, but has not been achieved on a proteome scale owing to the lack of intact protein fractionation methods that are well integrated with tandem mass spectrometry. Here we show, using a new four-dimensional separation system, identification of 1,043 gene products from human cells that are dispersed into more than 3,000 protein species created by post-translational modification (PTM), RNA splicing and proteolysis. The overall system produced greater than 20-fold increases in both separation power and proteome coverage, enabling the identification of proteins up to 105 kDa and those with up to 11 transmembrane helices. Many previously undetected isoforms of endogenous human proteins were mapped, including changes in multiply modified species in response to accelerated cellular ageing (senescence) induced by DNA damage. Integrated with the latest version of the Swiss-Prot database, the data provide precise correlations to individual genes and proof-of-concept for large-scale interrogation of whole protein molecules. The technology promises to improve the link between proteomics data and complex phenotypes in basic biology and disease research.
Assuntos
Isoformas de Proteínas/análise , Isoformas de Proteínas/química , Proteoma/análise , Proteoma/química , Proteômica/métodos , Processamento Alternativo , Linhagem Celular , Senescência Celular/genética , Dano ao DNA , Bases de Dados de Proteínas , Proteína HMGA1a/análise , Proteína HMGA1b/análise , Células HeLa , Humanos , Fenótipo , Processamento de Proteína Pós-Traducional , Proteólise , Proteômica/instrumentaçãoRESUMO
Deamidation of therapeutic antibodies may result in decreased drug activity and undesirable changes in pharmacokinetics and immunogenicity. Therefore, it is necessary to monitor the deamidation levels [during storage] and after in vivo administration. Because of the complexity of in vivo samples, immuno-affinity capture is widely used for specific enrichment of the target antibody prior to LC-MS. However, the conventional use of bead-based methods requires large sample volumes and extensive processing steps. Furthermore, with automation difficulties and extended sample preparation time, bead-based approaches may increase artificial deamidation. To overcome these challenges, we developed an automated platform to perform tip-based affinity capture of antibodies from complex matrixes with rapid digestion and peptide elution into 96-well microtiter plates followed by LC-MS analysis. Detailed analyses showed that the new method presents high repeatability and reproducibility with both intra and inter assay CVs < 8%. Using the automated platform, we successfully quantified the levels of deamidation of a humanized monoclonal antibody in cynomolgus monkeys over a time period of 12 weeks after administration. Moreover, we found that deamidation kinetics between in vivo samples and samples stressed in vitro at neutral pH were consistent, suggesting that the in vitro stress test may be used as a method to predict the liability to deamidation of therapeutic antibodies in vivo.
Assuntos
Anticorpos/isolamento & purificação , Anticorpos/metabolismo , Desaminação , Animais , Anticorpos/sangue , Anticorpos/uso terapêutico , Automação , Células CHO , Cromatografia Líquida , Cricetulus , Eritrócitos , Feminino , Citometria de Fluxo , Humanos , Macaca fascicularis , Espectrometria de MassasRESUMO
A fractionation method called gel-eluted liquid fraction entrapment electrophoresis (GELFrEE) has been used to dramatically increase the number of proteins identified in top-down proteomic workflows; however, the technique involves the use of sodium dodecyl sulfate (SDS), a surfactant that interferes with electrospray ionization. Therefore, an efficient removal of SDS is absolutely required prior to mass analysis. Traditionally, methanol/chloroform precipitation and spin columns have been used, but they lack reproducibility and are difficult to automate. Therefore, we developed an in-line matrix removal platform to enable the direct analysis of samples containing SDS and salts. Only small molecules like SDS permeate a porous membrane and are removed in a manner similar to cross-flow filtration. With this device, near-complete removal of SDS is accomplished within 5 min and proteins are subsequently mobilized into a mass spectrometer. The new platform was optimized for the analysis of GELFrEE fractions enriched for histones extracted from human HeLa cells. All four core histones and their proteoforms were detected in a single spectrum by high-resolution mass spectrometry. The new method versus protein precipitation/resuspension showed 2- to 10-fold improved signal intensities, offering a clear path forward to improve proteome coverage and the efficiency of top-down proteomics.
Assuntos
Eletroforese/instrumentação , Histonas/isolamento & purificação , Dodecilsulfato de Sódio/isolamento & purificação , Espectrometria de Massas por Ionização por Electrospray/métodos , Calibragem , Eletroforese/métodos , Células HeLa , Humanos , Membranas Artificiais , Porosidade , Isoformas de Proteínas/isolamento & purificação , Padrões de Referência , Dodecilsulfato de Sódio/químicaRESUMO
Structures similar to blood vessels in location, morphology, flexibility, and transparency have been recovered after demineralization of multiple dinosaur cortical bone fragments from multiple specimens, some of which are as old as 80 Ma. These structures were hypothesized to be either endogenous to the bone (i.e., of vascular origin) or the result of biofilm colonizing the empty osteonal network after degradation of original organic components. Here, we test the hypothesis that these structures are endogenous and thus retain proteins in common with extant archosaur blood vessels that can be detected with high-resolution mass spectrometry and confirmed by immunofluorescence. Two lines of evidence support this hypothesis. First, peptide sequencing of Brachylophosaurus canadensis blood vessel extracts is consistent with peptides comprising extant archosaurian blood vessels and is not consistent with a bacterial, cellular slime mold, or fungal origin. Second, proteins identified by mass spectrometry can be localized to the tissues using antibodies specific to these proteins, validating their identity. Data are available via ProteomeXchange with identifier PXD001738.
Assuntos
Vasos Sanguíneos/anatomia & histologia , Vasos Sanguíneos/metabolismo , Dinossauros/anatomia & histologia , Dinossauros/metabolismo , Fósseis/anatomia & histologia , Actinas/genética , Actinas/isolamento & purificação , Sequência de Aminoácidos , Animais , Vasos Sanguíneos/microbiologia , Osso e Ossos/irrigação sanguínea , Galinhas , Dinossauros/genética , Imunofluorescência/métodos , Espectrometria de Massas , Modelos Biológicos , Dados de Sequência Molecular , Miosinas/genética , Miosinas/isolamento & purificação , Filogenia , Proteômica/métodos , Alinhamento de Sequência , Especificidade da Espécie , Struthioniformes , Tropomiosina/genética , Tropomiosina/isolamento & purificação , Tubulina (Proteína)/genética , Tubulina (Proteína)/isolamento & purificaçãoRESUMO
We developed a method for restricted enzymatic proteolysis using the outer membrane protease T (OmpT) to produce large peptides (>6.3 kDa on average) for mass spectrometry-based proteomics. Using this approach to analyze prefractionated high-mass HeLa proteins, we identified 3,697 unique peptides from 1,038 proteins. We demonstrated the ability of large OmpT peptides to differentiate closely related protein isoforms and to enable the detection of many post-translational modifications.
Assuntos
Peptídeos/análise , Peptídeos/metabolismo , Proteólise , Proteômica/métodos , Serina Endopeptidases/metabolismo , Células HeLa , Humanos , Espectrometria de Massas , Peptídeos/química , Isoformas de Proteínas/química , Isoformas de Proteínas/metabolismo , Processamento de Proteína Pós-Traducional , Serina Endopeptidases/químicaRESUMO
Top-down proteomics is emerging as a viable method for the routine identification of hundreds to thousands of proteins. In this work we report the largest top-down study to date, with the identification of 1,220 proteins from the transformed human cell line H1299 at a false discovery rate of 1%. Multiple separation strategies were utilized, including the focused isolation of mitochondria, resulting in significantly improved proteome coverage relative to previous work. In all, 347 mitochondrial proteins were identified, including ~50% of the mitochondrial proteome below 30 kDa and over 75% of the subunits constituting the large complexes of oxidative phosphorylation. Three hundred of the identified proteins were found to be integral membrane proteins containing between 1 and 12 transmembrane helices, requiring no specific enrichment or modified LC-MS parameters. Over 5,000 proteoforms were observed, many harboring post-translational modifications, including over a dozen proteins containing lipid anchors (some previously unknown) and many others with phosphorylation and methylation modifications. Comparison between untreated and senescent H1299 cells revealed several changes to the proteome, including the hyperphosphorylation of HMGA2. This work illustrates the burgeoning ability of top-down proteomics to characterize large numbers of intact proteoforms in a high-throughput fashion.
Assuntos
Senescência Celular/genética , Células Epiteliais/metabolismo , Proteínas de Membrana/isolamento & purificação , Proteínas Mitocondriais/isolamento & purificação , Processamento de Proteína Pós-Traducional , Camptotecina/farmacologia , Fracionamento Celular , Linhagem Celular Transformada , Senescência Celular/efeitos dos fármacos , Cromatografia Líquida , Células Epiteliais/citologia , Células Epiteliais/efeitos dos fármacos , Regulação da Expressão Gênica , Ensaios de Triagem em Larga Escala , Humanos , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Metilação , Mitocôndrias/química , Mitocôndrias/metabolismo , Proteínas Mitocondriais/genética , Proteínas Mitocondriais/metabolismo , Anotação de Sequência Molecular , Complexos Multienzimáticos/genética , Complexos Multienzimáticos/metabolismo , Fosforilação , Proteômica/métodos , Transdução de Sinais , Espectrometria de Massas em TandemRESUMO
The direct analysis of intact proteins via MS offers compelling advantages in comparison to alternative methods due to the direct and unambiguous identification and characterization of protein sequences it provides. The inability to efficiently analyze proteins in the "middle mass range," defined here as proteins from 30 to 80 kDa, in a robust fashion has limited the adoption of these "top-down" methods. Largely, a result of poor liquid chromatographic performance, the limitations in this mass range may be addressed by alternative separations that replace chromatography. Herein, the short migration times of CZE-ESI-MS/MS have been extended to size-sorted whole proteins in complex mixtures from Pseudomonas aeruginosa PA01. An electrokinetically pumped nanospray interface, a coated capillary, and a stacking method for on-column sample concentration were developed to achieve high-loading capacity and separation resolution. We achieved full width at half maximum of 8-16 s for model proteins up to 29 kDa and identified 30 proteins in the mass range of 30-80 kDa from P. aeruginosa PA01 whole cell lysate. These results suggest that CZE-ESI-MS/MS is capable of identifying proteins in the middle mass range in top-down proteomics.
Assuntos
Eletroforese Capilar/métodos , Proteínas/análise , Proteínas/química , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Dados de Sequência Molecular , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodosRESUMO
The interrogation of intact integral membrane proteins has long been a challenge for biological mass spectrometry. Here, we demonstrate the application of top down mass spectrometry to whole membrane proteins below 60 kDa with up to 8 transmembrane helices. Analysis of enriched mitochondrial membrane preparations from human cells yielded identification of 83 integral membrane proteins, along with 163 membrane-associated or soluble proteins, with a median q value of 3 × 10(-10). An analysis of matching fragment ions demonstrated that significantly more fragment ions were found within transmembrane domains than would be expected based upon the observed protein sequence. In total, 46 proteins from the complexes of oxidative phosphorylation were identified which exemplifies the increasing ability of top down proteomics to provide extensive coverage in a biological network.
Assuntos
Proteínas de Membrana/genética , Mitocôndrias/genética , Proteômica/métodos , Sequência de Aminoácidos , Células HeLa , Humanos , Proteínas de Membrana/análise , Mitocôndrias/química , Dados de Sequência MolecularRESUMO
Protein tyrosine phosphatase SHP2 mediates RAS-driven MAPK signaling and has emerged in recent years as a target of interest in oncology, both for treating with a single agent and in combination with a KRAS inhibitor. We were drawn to the pharmacological potential of SHP2 inhibition, especially following the initial observation that drug-like compounds could bind an allosteric site and enforce a closed, inactive state of the enzyme. Here, we describe the identification and characterization of GDC-1971 (formerly RLY-1971), a SHP2 inhibitor currently in clinical trials in combination with KRAS G12C inhibitor divarasib (GDC-6036) for the treatment of solid tumors driven by a KRAS G12C mutation.
RESUMO
Mass spectrometry based proteomics generally seeks to identify and fully characterize protein species with high accuracy and throughput. Recent improvements in protein separation have greatly expanded the capacity of top-down proteomics (TDP) to identify a large number of intact proteins. To date, TDP has been most tightly associated with Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. Here, we couple the improved separations to a Fourier-transform instrument based not on ICR but using the Orbitrap Elite mass analyzer. Application of this platform to H1299 human lung cancer cells resulted in the unambiguous identification of 690 unique proteins and over 2000 proteoforms identified from proteins with intact masses<50 kDa. This is an early demonstration of high throughput TDP (>500 identifications) in an Orbitrap mass spectrometer and exemplifies an accessible platform for whole protein mass spectrometry.
Assuntos
Análise de Fourier , Proteoma/química , Espectrometria de Massas em Tandem/normas , Sequência de Aminoácidos , Camptotecina/farmacologia , Pontos de Checagem do Ciclo Celular , Linhagem Celular Tumoral , Senescência Celular , Dano ao DNA , Humanos , Dados de Sequência Molecular , Fragmentos de Peptídeos/química , Mapeamento de Peptídeos , Proteoma/isolamento & purificação , Proteômica , Padrões de Referência , Inibidores da Topoisomerase/farmacologiaRESUMO
The diverse proteome of an organism arises from such events as single nucleotide substitutions at the DNA level, different RNA processing, and dynamic enzymatic post-translational modifications. This minireview focuses on the measurement of intact proteins to describe the diversity found in proteomes. The field of biological mass spectrometry has steadily advanced, enabling improvements in the characterization of single proteins to proteins derived from cells or tissues. In this minireview, we discuss the basic technology for "top-down" intact protein analysis. Furthermore, examples of studies involved with the qualitative and quantitative analysis of full-length polypeptides are provided.