1.
Clin Lab ; 70(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38213197

RESUMO

BACKGROUND: Several nations around the world have utilized autologous immune enhancement therapy in the treatment of cancer, with initial positive outcomes. This study describes our experience with autologous gamma delta T cell immunotherapy for the treatment of non-small cell lung cancer patients in Vietnam, a developing nation. METHODS: Five patients with non-small cell lung cancer at stages III - IV were enrolled in the study. Each patient received six infusions of autologous γδT cells, separated by two weeks. Before, during, at the end of treatment, and three and six months after treatment, a comprehensive evaluation of clinical, laboratory, quality of life, and adverse events related to the method was conducted. RESULTS: At the time of culture seeding, the total number of cells ranged from 2.9 to 18.2 x 106, with γδT cells ranging in number from 10.7 to 19.6 x 104. On day 14 of the culture, the number of γδT cells ranged from 3.1 to 8.3 x 108. Regarding the safety of therapy in a total of 30 infusions, two (fever), one (myalgia), and one (joint pain) were graded as 1 by CTCAE criteria. After the course, no toxicity was observed in the hematopoietic system, kidney function, or liver function. Evaluation of the patient's response in accordance with the RECIST 1.1 criteria: 20% of patients (one patient) had partial response disease, and 80% of patients (four patients) had stable disease at the end of treatment. During the follow-up period of the study, three patients were still alive, and the disease remained stable. The patient's quality of life improved after treatment in most functional measures (activity, cognitive, and social), but physical and emotional scores decreased slightly. Two patients' fatigue symptoms increased, but after six months of treatment, the average value dropped from 25.3 to 8.3. Dyspnea symptoms decreased gradually from 33.3 at the start of treatment to 8.3 six months later. CONCLUSIONS: The initial results we obtained regarding the efficacy and safety of autologous γδT cell immunotherapy for patients with non-small cell lung cancer are extremely encouraging and comparable to those of previous studies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Ácido Zoledrônico/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Qualidade de Vida , Imunoterapia/métodos , Linfócitos T
2.
Public Health Nutr ; 27(1): e150, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639132

RESUMO

OBJECTIVE: To assess the nutritional status, growth parameters and lifestyle behaviours of children between 0·5 and 12 years in nationally representative samples in Malaysia, Indonesia, Thailand and Vietnam. DESIGN: A cross-sectional study was conducted in the four countries, between May 2019 and April 2021. Data collected can be categorised into four categories: (1) Growth - anthropometry, body composition, development disorder, (2) nutrient intake and dietary habits - 24-h dietary recall, child food habits, breast-feeding and complementary feeding, (3) socio-economic status - food insecurity and child health status/environmental and (4) lifestyle behaviours - physical activity patterns, fitness, sunlight exposure, sleep patterns, body image and behavioural problems. Blood samples were also collected for biochemical and metabolomic analyses. With the pandemic emerging during the study, a COVID-19 questionnaire was developed and implemented. SETTING: Both rural and urban areas in Malaysia, Indonesia, Thailand and Vietnam. PARTICIPANTS: Children who were well, with no physical disability or serious infections/injuries and between the age of 0·5 and 12 years old, were recruited. RESULTS: The South East Asian Nutrition Surveys II recruited 13 933 children. Depending on the country, data collection from children was conducted in schools and commune health centres, or temples, or sub-district administrative organisations. CONCLUSIONS: The results will provide up-to-date insights into nutritional status and lifestyle behaviours of children in the four countries. Subsequently, these data will facilitate exploration of potential gaps in dietary intake among Southeast Asian children and enable local authorities to plan future nutrition and lifestyle intervention strategies.


Assuntos
COVID-19 , Estilo de Vida , Inquéritos Nutricionais , Estado Nutricional , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Sudeste Asiático , Fenômenos Fisiológicos da Nutrição Infantil , COVID-19/epidemiologia , Estudos Transversais , Dieta/estatística & dados numéricos , Comportamento Alimentar , Indonésia/epidemiologia , Malásia/epidemiologia , Tailândia/epidemiologia , Vietnã/epidemiologia
3.
Arterioscler Thromb Vasc Biol ; 42(1): 19-34, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34789002

RESUMO

OBJECTIVE: Fluid shear stress (FSS) is known to mediate multiple phenotypic changes in the endothelium. Laminar FSS (undisturbed flow) is known to promote endothelial alignment to flow, which is key to stabilizing the endothelium and rendering it resistant to atherosclerosis and thrombosis. The molecular pathways responsible for endothelial responses to FSS are only partially understood. In this study, we determine the role of PGC1α (peroxisome proliferator gamma coactivator-1α)-TERT (telomerase reverse transcriptase)-HMOX1 (heme oxygenase-1) during shear stress in vitro and in vivo. Approach and Results: Here, we have identified PGC1α as a flow-responsive gene required for endothelial flow alignment in vitro and in vivo. Compared with oscillatory FSS (disturbed flow) or static conditions, laminar FSS (undisturbed flow) showed increased PGC1α expression and its transcriptional coactivation. PGC1α was required for laminar FSS-induced expression of TERT in vitro and in vivo via its association with ERRα(estrogen-related receptor alpha) and KLF (Kruppel-like factor)-4 on the TERT promoter. We found that TERT inhibition attenuated endothelial flow alignment, elongation, and nuclear polarization in response to laminar FSS in vitro and in vivo. Among the flow-responsive genes sensitive to TERT status, HMOX1 was required for endothelial alignment to laminar FSS. CONCLUSIONS: These data suggest an important role for a PGC1α-TERT-HMOX1 axis in the endothelial stabilization response to laminar FSS.


Assuntos
Células Endoteliais/enzimologia , Heme Oxigenase-1/metabolismo , Mecanotransdução Celular , Proteínas de Membrana/metabolismo , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo , Telomerase/metabolismo , Animais , Células Cultivadas , Células Endoteliais/patologia , Transição Epitelial-Mesenquimal , Feminino , Regulação Enzimológica da Expressão Gênica , Heme Oxigenase-1/genética , Células Endoteliais da Veia Umbilical Humana/enzimologia , Células Endoteliais da Veia Umbilical Humana/patologia , Humanos , Masculino , Proteínas de Membrana/genética , Camundongos Endogâmicos C57BL , Camundongos Knockout , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/genética , Fluxo Sanguíneo Regional , Estresse Mecânico , Telomerase/genética
4.
Echocardiography ; 37(6): 832-840, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32437588

RESUMO

AIMS: Despite three decades of study, it is still challenging to discriminate acute apical variant stress cardiomyopathy (AVSCM) from acute left anterior descending-myocardial infarction (LAD-MI) at the time of presentation. A biomarker or practical imaging modality that can differentiate these two entities is highly desirable. Our objective was to characterize left ventricular (LV) mechanical deformation using 2-dimensional (2D) echocardiographic strain imaging in an attempt to discriminate AVSCM from LAD-MI at presentation. METHODS AND RESULTS: We studied 108 women (60 AVSCM, 48 ST segment elevation LAD-MI). All underwent echocardiography within 48 hours of presentation. 2D longitudinal strain (LS) from an 18-segment LV model was performed, with global LS (GLS) taken as the average of all 18 segments. GLS was abnormal, but did not differentiate AVSCM from LAD-MI. Mean LS of the basal and mid-anterior, basal, and mid-anteroseptum segments were significantly lower in LAD-MI vs AVSCM group (-14 ± 9% vs -20 ± 8%; -11 ± 7% vs -14 ± 6%; -9 ± 8% vs -14 ± 8%; -9 ± 7% vs -13 ± 5%, respectively, all P ≤ .05). Mean LS of the basal inferior and inferolateral segments was significantly higher in the LAD-MI vs. AVSCM group (-19 ± 9% vs -13 ± 7%; -23 ± 11% vs -18 ± 7%, respectively, all P ≤ .05). Using ROC curve analysis, segmental strain ratio of average basal inferior and inferolateral segments LS to average mid- and basal anterior and anteroseptum segments LS of ≥1.58 was 90% specific for LAD-MI [area under the curve (AUC) 0.87; P < .001]. CONCLUSION: Longitudinal strain patterns are useful in discriminating AVSCM from LAD-MI patients at presentation and may be valuable in stratifying patients for invasive evaluation.


Assuntos
Infarto Miocárdico de Parede Anterior , Cardiomiopatias , Cardiomiopatia de Takotsubo , Disfunção Ventricular Esquerda , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Cardiomiopatia de Takotsubo/diagnóstico por imagem
5.
IEEE Trans Biomed Eng ; 71(2): 456-466, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37682653

RESUMO

OBJECTIVE: We propose an efficient approach based on a convolutional denoising autoencoder (CDA) network to reduce motion and noise artifacts (MNA) from corrupted atrial fibrillation (AF) and non-AF photoplethysmography (PPG) data segments so that an accurate PPG-signal-derived heart rate can be obtained. Our method's main innovation is the optimization of the CDA performance for both rhythms using more AF than non-AF data for training the AF-specific CDA model and vice versa for the non-AF CDA network. METHODS: To evaluate this unconventional training scheme, our proposed network was trained and tested on 25-sec PPG data segments from 48 subjects from two different databases-the Pulsewatch dataset and Stanford University's publicly available PPG dataset. In total, our dataset contains 10,773 data segments: 7,001 segments for training and 3,772 independent segments from out-of-sample subjects for testing. RESULTS: Using real-life corrupted PPG segments, our approach significantly reduced the average heart rate root mean square error (RMSE) of the reconstructed PPG segments by 45.74% and 23% compared to the corrupted non-AF and AF data, respectively. Further, our approach exhibited lower RMSE, and higher sensitivity and PPV for detected peaks compared to the reconstructed data produced by the alternative methods. CONCLUSION: These results show the promise of our approach as a reliable denoising method, which should be used prior to AF detection algorithms for an accurate cardiac health monitoring involving wearable devices. SIGNIFICANCE: PPG signals collected from wearables are vulnerable to MNA, which limits their use as a reliable measurement, particularly in uncontrolled real-life environments.


Assuntos
Fibrilação Atrial , Fotopletismografia , Humanos , Fotopletismografia/métodos , Fibrilação Atrial/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Movimento (Física) , Algoritmos , Processamento de Sinais Assistido por Computador , Artefatos
6.
J Geriatr Cardiol ; 21(3): 323-330, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38665288

RESUMO

BACKGROUND: Smartwatches have become readily accessible tools for detecting atrial fibrillation (AF). There remains limited data on how they affect psychosocial outcomes and engagement in older adults. We examine the health behavior outcomes of stroke survivors prescribed smartwatches for AF detection stratified by age. METHODS: We analyzed data from the Pulsewatch study, a randomized controlled trial that enrolled patients (≥ 50 years) with a history of stroke or transient ischemic attack and CHA2DS2-VASc ≥ 2. Intervention participants were equipped with a cardiac patch monitor and a smartwatch-app dyad, while control participants wore the cardiac patch monitor for up to 44 days. We evaluated health behavior parameters using standardized tools, including the Consumer Health Activation Index, the Generalized Anxiety Disorder questionnaire, the 12-Item Short Form Health Survey, and wear time of participants categorized into three age groups: Group 1 (ages 50-60), Group 2 (ages 61-69), and Group 3 (ages 70-87). We performed statistical analysis using a mixed-effects repeated measures linear regression model to examine differences amongst age groups. RESULTS: Comparative analysis between Groups 1, 2 and 3 revealed no significant differences in anxiety, patient activation, perception of physical health and wear time. The use of smartwatch technology was associated with a decrease in perception of mental health for Group 2 compared to Group 1 (ß = -3.29, P = 0.046). CONCLUSION: Stroke survivors demonstrated a willingness to use smartwatches for AF monitoring. Importantly, among these study participants, the majority did not experience negative health behavior outcomes or decreased engagement as age increased.

7.
JMIR Cardio ; 7: e41691, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36780211

RESUMO

BACKGROUND: The prevalence of atrial fibrillation (AF) increases with age and can lead to stroke. Therefore, older adults may benefit the most from AF screening. However, older adult populations tend to lag more than younger groups in the adoption of, and comfort with, the use of mobile health (mHealth) apps. Furthermore, although mobile apps that can detect AF are available to the public, most are designed for intermittent AF detection and for younger users. No app designed for long-term AF monitoring has released detailed system design specifications that can handle large data collections, especially in this age group. OBJECTIVE: This study aimed to design an innovative smartwatch-based AF monitoring mHealth solution in collaboration with older adult participants and clinicians. METHODS: The Pulsewatch system is designed to link smartwatches and smartphone apps, a website for data verification, and user data organization on a cloud server. The smartwatch in the Pulsewatch system is designed to continuously monitor the pulse rate with embedded AF detection algorithms, and the smartphone in the Pulsewatch system is designed to serve as the data-transferring hub to the cloud storage server. RESULTS: We implemented the Pulsewatch system based on the functionality that patients and caregivers recommended. The user interfaces of the smartwatch and smartphone apps were specifically designed for older adults at risk for AF. We improved our Pulsewatch system based on feedback from focus groups consisting of patients with stroke and clinicians. The Pulsewatch system was used by the intervention group for up to 6 weeks in the 2 phases of our randomized clinical trial. At the conclusion of phase 1, 90 trial participants who had used the Pulsewatch app and smartwatch for 14 days completed a System Usability Scale to assess the usability of the Pulsewatch system; of 88 participants, 56 (64%) endorsed that the smartwatch app is "easy to use." For phases 1 and 2 of the study, we collected 9224.4 hours of smartwatch recordings from the participants. The longest recording streak in phase 2 was 21 days of consecutive recordings out of the 30 days of data collection. CONCLUSIONS: This is one of the first studies to provide a detailed design for a smartphone-smartwatch dyad for ambulatory AF monitoring. In this paper, we report on the system's usability and opportunities to increase the acceptability of mHealth solutions among older patients with cognitive impairment. TRIAL REGISTRATION: ClinicalTrials.gov NCT03761394; https://www.clinicaltrials.gov/ct2/show/NCT03761394. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1016/j.cvdhj.2021.07.002.

8.
Cardiovasc Digit Health J ; 4(4): 118-125, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37600446

RESUMO

Background: The detection of atrial fibrillation (AF) in stroke survivors is critical to decreasing the risk of recurrent stroke. Smartwatches have emerged as a convenient and accurate means of AF diagnosis; however, the impact on critical patient-reported outcomes, including anxiety, engagement, and quality of life, remains ill defined. Objectives: To examine the association between smartwatch prescription for AF detection and the patient-reported outcomes of anxiety, patient activation, and self-reported health. Methods: We used data from the Pulsewatch trial, a 2-phase randomized controlled trial that included participants aged 50 years or older with a history of ischemic stroke. Participants were randomized to use either a proprietary smartphone-smartwatch app for 30 days of AF monitoring or no cardiac rhythm monitoring. Validated surveys were deployed before and after the 30-day study period to assess anxiety, patient activation, and self-rated physical and mental health. Logistic regression and generalized estimation equations were used to examine the association between smartwatch prescription for AF monitoring and changes in the patient-reported outcomes. Results: A total of 110 participants (mean age 64 years, 41% female, 91% non-Hispanic White) were studied. Seventy percent of intervention participants were novice smartwatch users, as opposed to 84% of controls, and there was no significant difference in baseline rates of anxiety, activation, or self-rated health between the 2 groups. The incidence of new AF among smartwatch users was 6%. Participants who were prescribed smartwatches did not have a statistically significant change in anxiety, activation, or self-reported health as compared to those who were not prescribed smartwatches. The results held even after removing participants who received an AF alert on the watch. Conclusion: The prescription of smartwatches to stroke survivors for AF monitoring does not adversely affect key patient-reported outcomes. Further research is needed to better inform the successful deployment of smartwatches in clinical practice.

9.
Cardiol Cardiovasc Med ; 7(2): 97-107, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476150

RESUMO

Wrist-based wearables have been FDA approved for AF detection. However, the health behavior impact of false AF alerts from wearables on older patients at high risk for AF are not known. In this work, we analyzed data from the Pulsewatch (NCT03761394) study, which randomized patients (≥50 years) with history of stroke or transient ischemic attack to wear a patch monitor and a smartwatch linked to a smartphone running the Pulsewatch application vs to only the cardiac patch monitor over 14 days. At baseline and 14 days, participants completed validated instruments to assess for anxiety, patient activation, perceived mental and physical health, chronic symptom management self-efficacy, and medicine adherence. We employed linear regression to examine associations between false AF alerts with change in patient-reported outcomes. Receipt of false AF alerts was related to a dose-dependent decline in self-perceived physical health and levels of disease self-management. We developed a novel convolutional denoising autoencoder (CDA) to remove motion and noise artifacts in photoplethysmography (PPG) segments to optimize AF detection, which substantially reduced the number of false alerts. A promising approach to avoid negative impact of false alerts is to employ artificial intelligence driven algorithms to improve accuracy.

10.
Ann Med ; 55(1): 526-532, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36724401

RESUMO

BACKGROUND: Early detection of AF is critical for stroke prevention. Several commercially available smartwatches are FDA cleared for AF detection. However, little is known about how patient-physician relationships affect patients' anxiety, activation, and health-related quality of life when prescribed smartwatch for AF detection. METHODS: Data were used from the Pulsewatch study (NCT03761394), which randomized adults (>50 years) with no contraindication to anticoagulation and a CHA2DS2-VASc risk score ≥2 to receive a smartwatch-smartphone app dyad for AF monitoring vs. conventional monitoring with an ECG patch (Cardea SoloTM) and monitored participants for up to 45 days. The Perceived Efficacy in Patient-Physician Interactions survey was used to assess patient confidence in physician interaction at baseline with scores ≥45 indicating high perceived efficacy in patient-provider interactions. Generalized Anxiety Disorder-7 Scale, Consumer Health Activation Index, and Short-Form Health Survey were utilized to examine anxiety, patient activation, and physical and mental health status, at baseline, 14, and 44 days, respectively. We used mixed-effects repeated measures linear regression models to assess changes in psychosocial outcomes among smartwatch users in relation to self-reported efficacy in physician interaction over the study period. RESULTS: A total of 93 participants (average age 64.1 ± 8.9 years; 43.0% female; 88.2% non-Hispanic white) were included in this analysis. At baseline, fifty-six (60%) participants reported high perceived efficacy in patient-physician interaction. In the fully adjusted models, high perceived efficacy (vs. low) at baseline was associated with greater patient activation and perceived mental health (ß 12.0, p-value <0.001; ß 3.39, p-value <0.05, respectively). High perceived self-efficacy was not associated with anxiety or physical health status (ß - 0.61, p-value 0.46; ß 0.64, p-value 0.77) among study participants. CONCLUSIONS: Higher self-efficacy in patient-physician interaction was associated with higher patient activation and mental health status among stroke survivors using smartwatches. Furthermore, we found no association between anxiety and smartwatch prescription for AF in participants with high self-efficacy in patient-physician interaction. Efforts to improve self-efficacy in patient-physician interaction may improve patient activation and self-rated health and subsequently may lead to better clinical outcomes.KEY MESSAGESHigher self-efficacy in patient-physician interaction was associated with higher patient activation and mental health status among stroke survivors using smartwatches.No association between anxiety and smartwatch prescription for AF in participants with high self-efficacy in patient-physician interaction.Efforts to improve self-efficacy in patient-physician interaction may improve patient activation and self-rated health and subsequently may lead to better clinical outcomes.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ansiedade/etiologia , Transtornos de Ansiedade/complicações , Fibrilação Atrial/complicações , Participação do Paciente , Qualidade de Vida , Autorrelato , Acidente Vascular Cerebral/prevenção & controle
11.
JMIR Cardio ; 7: e45137, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38015598

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. OBJECTIVE: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. METHODS: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. RESULTS: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. CONCLUSIONS: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. TRIAL REGISTRATION: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1016/j.cvdhj.2021.07.002.

12.
Front Digit Health ; 5: 1243959, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125757

RESUMO

Background: Increasing ownership of smartphones among Americans provides an opportunity to use these technologies to manage medical conditions. We examine the influence of baseline smartwatch ownership on changes in self-reported anxiety, patient engagement, and health-related quality of life when prescribed smartwatch for AF detection. Method: We performed a post-hoc secondary analysis of the Pulsewatch study (NCT03761394), a clinical trial in which 120 participants were randomized to receive a smartwatch-smartphone app dyad and ECG patch monitor compared to an ECG patch monitor alone to establish the accuracy of the smartwatch-smartphone app dyad for detection of AF. At baseline, 14 days, and 44 days, participants completed the Generalized Anxiety Disorder-7 survey, the Health Survey SF-12, and the Consumer Health Activation Index. Mixed-effects linear regression models using repeated measures with anxiety, patient activation, physical and mental health status as outcomes were used to examine their association with smartwatch ownership at baseline. Results: Ninety-six participants, primarily White with high income and tertiary education, were randomized to receive a study smartwatch-smartphone dyad. Twenty-four (25%) participants previously owned a smartwatch. Compared to those who did not previously own a smartwatch, smartwatch owners reported significant greater increase in their self-reported physical health (ß = 5.07, P < 0.05), no differences in anxiety (ß = 0.92, P = 0.33), mental health (ß = -2.42, P = 0.16), or patient activation (ß = 1.86, P = 0.54). Conclusions: Participants who own a smartwatch at baseline reported a greater positive change in self-reported physical health, but not in anxiety, patient activation, or self-reported mental health over the study period.

13.
Cardiovasc Digit Health J ; 3(3): 126-135, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35720675

RESUMO

Background: Smartwatches can be used for atrial fibrillation (AF) detection, but little is known about how older adults at risk for AF perceive their usability. Methods: We employed a mixed-methods study design using data from the ongoing Pulsewatch study, a randomized clinical trial (NCT03761394) examining the accuracy of a smartwatch-smartphone app dyad (Samsung/Android) compared to usual care with a patch monitor (Cardea SOLO™ ECG System) for detection of AF among older stroke survivors. To be eligible to participate in Pulsewatch, participants needed to be at least 50 years of age, have had an ischemic stroke, and have no major contraindications to anticoagulation therapy should AF be detected. After 14 days of use, usability was measured by the System Usability Scale (SUS) and investigator-generated questions. Qualitative interviews were conducted, transcribed, and coded via thematic analysis. Results: Ninety participants in the Pulsewatch trial were randomized to use a smartwatch-smartphone app dyad for 14 days (average age: 65 years, 41% female, 87% White), and 46% found it to be highly usable (SUS ≥68). In quantitative surveys, participants who used an assistive device (eg, wheelchair) and those with history of anxiety or depression were more likely to report anxiety associated with watch use. In qualitative interviews, study participants reported wanting a streamlined system that was more focused on rhythm monitoring and a smartwatch with a longer battery life. In-person training and support greatly improved their experience, and participants overwhelmingly preferred use of a smartwatch over traditional cardiac monitoring owing to its comfort, appearance, and convenience. Conclusion: Older adults at high risk for AF who were randomized to use a smartwatch-app dyad for AF monitoring over 14 days found it to be usable for AF detection and preferred their use to the use of a patch monitor. However, participants reported that a simpler device interface and longer smartwatch battery life would increase the system's usability.

14.
Am J Cardiol ; 181: 32-37, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-35985871

RESUMO

Current guidelines encourage regular physical activity (PA) to gain cardiovascular health benefit. However, little is known about whether older adults with atrial fibrillation (AF) who engage in the guideline-recommended level of PA are less likely to experience clinically relevant outcomes. We did a retrospective study based on the data from Systemic Assessment of Geriatric Elements in AF (SAGE-AF) prospective cohort study. The study population consisted of older participants with AF (≥65 years) and a congestive heart failure, hypertension, age, diabetes, stroke vascular disease, age 65 to 75 and sex(CHA2DS2-VASc) score ≥2. PA was quantified by self-reported Minnesota Leisure Time PA questionnaire. Competing risk models were used to examine the association between PA level and clinical outcomes over 2 years while controlling for several potentially confounding variables. A total of 1,244 participants (average age 76 years; 51% men; 85% non-Hispanic White) were studied. A total of 50.5% of participants engaged in regular PA. Meeting the recommended level of PA was associated with lower mortality over 2 years (adjusted hazard ratio 0.60, 95% confidence interval 0.38 to 0.95) but was not associated with rates of stroke or major bleeding. In conclusion, older adults with AF who engaged in guideline-recommended PA are more likely to survive in the long term. Healthcare providers should promote and encourage engagement in PA and tailor interventions to address barriers of engagement.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Anticoagulantes , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Exercício Físico , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Autorrelato , Acidente Vascular Cerebral/epidemiologia
15.
IEEE Trans Biomed Eng ; 69(9): 2982-2993, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35275809

RESUMO

OBJECTIVE: With the increasing use of wearable healthcare devices for remote patient monitoring, reliable signal quality assessment (SQA) is required to ensure the high accuracy of interpretation and diagnosis on the recorded data from patients. Photoplethysmographic (PPG) signals non-invasively measured by wearable devices are extensively used to provide information about the cardiovascular system and its associated diseases. In this study, we propose an approach to optimize the quality assessment of the PPG signals. METHODS: We used an ensemble-based feature selection scheme to enhance the prediction performance of the classification model to assess the quality of the PPG signals. Our approach for feature and subset size selection yielded the best-suited feature subset, which was optimized to differentiate between the clean and artifact corrupted PPG segments. CONCLUSION: A high discriminatory power was achieved between two classes on the test data by the proposed feature selection approach, which led to strong performance on all dependent and independent test datasets. We achieved accuracy, sensitivity, and specificity rates of higher than 0.93, 0.89, and 0.97, respectively, for dependent test datasets, independent of heartbeat type, i.e., atrial fibrillation (AF) or non-AF data including normal sinus rhythm (NSR), premature atrial contraction (PAC), and premature ventricular contraction (PVC). For independent test datasets, accuracy, sensitivity, and specificity rates were greater than 0.93, 0.89, and 0.97, respectively, on PPG data recorded from AF and non-AF subjects. These results were found to be more accurate than those of all of the contemporary methods cited in this work. SIGNIFICANCE: As the results illustrate, the advantage of our proposed scheme is its robustness against dynamic variations in the PPG signal during long-term 14-day recordings accompanied with different types of physical activities and a diverse range of fluctuations and waveforms caused by different individual hemodynamic characteristics, and various types of recording devices. This robustness instills confidence in the application of the algorithm to various kinds of wearable devices as a reliable PPG signal quality assessment approach.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Algoritmos , Artefatos , Eletrocardiografia/métodos , Frequência Cardíaca , Humanos , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
16.
Cardiovasc Digit Health J ; 3(3): 118-125, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35720678

RESUMO

Background: Little is known about online health information-seeking behavior among older adults with atrial fibrillation (AF) and its association with self-reported outcomes. Objective: To examine patient characteristics associated with online health information seeking and the association between information seeking and low AF-related quality of life and high perceived efficacy in patient-physician interaction. Methods: We used data from the SAGE-AF (Systematic Assessment of Geriatric Elements in AF) study, which includes older participants aged ≥65 years with AF and a CHA2DS2-VASc risk score ≥2. To assess online health information seeking, participants who reported using the Internet were asked at baseline if they used the Internet to search for advice or information about their health in the past 4 weeks (not at all vs at least once). Atrial Fibrillation Effect on Quality of Life and Perceived Efficacy in Patient-Physician Interactions questionnaires were used to examine AF-related quality of life (QOL) and patient-reported confidence in physicians. Logistic regression models were used to examine demographic and clinical factors associated with online health information seeking and associations between information seeking and low AF-related QOL (AFEQT <80) and high perceived efficacy for patient-physician interactions (PEPPI ≥45). Results: A total of 874 online participants (mean age 74.5 years, 51% male, 91% non-Hispanic White) were studied. Approximately 60% of participants sought health information online. Participants aged 74 years or older and those on anticoagulation were less likely, while those with a college degree were more likely, to seek online health information after adjusting for potential confounders. Participants who sought health information online, compared to those who did not, were significantly more likely to have a low AF-related QOL, but less likely to self-report confidence in patient-physician interaction (aOR = 1.56, 95% CI: 1.15-2.13; aOR = 0.68, 95% CI: 0.49-0.93, respectively). Conclusion: Clinicians should consider barriers to patient-physician interaction in older adults who seek health information online, encourage shared decision-making, and provide patients with a list of online resources for AF in addition to disease education plans to help patients manage their health.

17.
PLoS One ; 15(8): e0236960, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32813736

RESUMO

BACKGROUND: Circulating microRNAs may reflect or influence pathological cardiac remodeling and contribute to atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to identify candidate plasma microRNAs that are associated with echocardiographic phenotypes of atrial remodeling, and incident and prevalent AF in a community-based cohort. METHODS: We analyzed left atrial function index (LAFI) of 1788 Framingham Offspring 8 participants. We quantified expression of 339 plasma microRNAs. We examined associations between microRNA levels with LAFI and prevalent and incident AF. We constructed pathway analysis of microRNAs' predicted gene targets to identify molecular processes involved in adverse atrial remodeling in AF. RESULTS: The mean age of the participants was 66 ± 9 years, and 54% were women. Five percent of participants had prevalent AF at the initial examination and 9% (n = 157) developed AF over a median 8.6 years of follow-up (IQR 8.1-9.2 years). Plasma microRNAs were associated with LAFI (N = 73, p<0.0001). Six of these plasma microRNAs were significantly associated with incident AF, including 4 also associated with prevalent AF (microRNAs 106b, 26a-5p, 484, 20a-5p). These microRNAs are predicted to regulate genes involved in cardiac hypertrophy, inflammation, and myocardial fibrosis. CONCLUSIONS: Circulating microRNAs 106b, 26a-5p, 484, 20a-5p are associated with atrial remodeling and AF.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/genética , Remodelamento Atrial/genética , MicroRNAs/sangue , MicroRNAs/genética , Idoso , Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo/genética , Função do Átrio Esquerdo/fisiologia , Remodelamento Atrial/fisiologia , Biomarcadores/sangue , Estudos de Coortes , Ecocardiografia , Feminino , Marcadores Genéticos , Predisposição Genética para Doença , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
18.
Nat Metab ; 2(5): 397-412, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32440655

RESUMO

Human thermogenic adipose tissue mitigates metabolic disease, raising much interest in understanding its development and function. Here, we show that human thermogenic adipocytes specifically express a primate-specific long non-coding RNA, LINC00473 which is highly correlated with UCP1 expression and decreased in obesity and type-2 diabetes. LINC00473 is detected in progenitor cells, and increases upon differentiation and in response to cAMP. In contrast to other known adipocyte LincRNAs, LINC00473 shuttles out of the nucleus, colocalizes and can be crosslinked to mitochondrial and lipid droplet proteins. Up- or down- regulation of LINC00473 results in reciprocal alterations in lipolysis, respiration and transcription of genes associated with mitochondrial oxidative metabolism. Depletion of PLIN1 results in impaired cAMP-responsive LINC00473 expression and lipolysis, indicating bidirectional interactions between PLIN1, LINC00473 and mitochondrial oxidative functions. Thus, we suggest that LINC00473 is a key regulator of human thermogenic adipocyte function, and reveals a role for a LincRNA in inter-organelle communication and human energy metabolism.


Assuntos
Adipócitos/fisiologia , RNA Longo não Codificante/genética , RNA Longo não Codificante/fisiologia , Termogênese/genética , Termogênese/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Comunicação Celular/genética , Comunicação Celular/fisiologia , Núcleo Celular/metabolismo , Células Cultivadas , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/metabolismo , Metabolismo Energético/genética , Metabolismo Energético/fisiologia , Ácidos Graxos não Esterificados/metabolismo , Feminino , Regulação da Expressão Gênica , Humanos , Gotículas Lipídicas , Masculino , Pessoa de Meia-Idade , Obesidade/genética , Obesidade/metabolismo , Consumo de Oxigênio/genética , Consumo de Oxigênio/fisiologia , Perilipina-1/deficiência , Perilipina-1/genética , Proteína Desacopladora 1/biossíntese , Proteína Desacopladora 1/genética , Adulto Jovem
20.
JCI Insight ; 4(20)2019 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-31513547

RESUMO

Epicardial adipose tissue (EAT) is the visceral fat depot of the heart. Inflammation of EAT is thought to contribute to coronary artery disease (CAD). Therefore, we hypothesized that the EAT of patients with CAD would have increased inflammatory gene expression compared with controls without CAD. Cardiac surgery patients with (n = 13) or without CAD (n = 13) were consented, and samples of EAT and subcutaneous adipose tissue (SAT) were obtained. Transcriptomic analysis was performed using Affymetrix Human Gene 1.0 ST arrays. Differential expression was defined as a 1.5-fold change (ANOVA P < 0.05). Six hundred ninety-three genes were differentially expressed between SAT and EAT in controls and 805 in cases. Expression of 326 genes was different between EAT of cases and controls; expression of 14 genes was increased in cases, while 312 were increased in controls. Quantitative reverse transcription PCR confirmed that there was no difference in expression of CCL2, CCR2, TNF-α, IL-6, IL-8, and PAI1 between groups. Immunohistochemistry showed more macrophages in EAT than SAT, but there was no difference in their number or activation state between groups. In contrast to prior studies, we did not find increased inflammatory gene expression in the EAT of patients with CAD. We conclude that the specific adipose tissue depot, rather than CAD status, is responsible for the majority of differential gene expression.


Assuntos
Doença da Artéria Coronariana/imunologia , Mediadores da Inflamação/metabolismo , Gordura Intra-Abdominal/patologia , Pericárdio/patologia , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Feminino , Perfilação da Expressão Gênica , Humanos , Gordura Intra-Abdominal/imunologia , Gordura Intra-Abdominal/cirurgia , Masculino , Pessoa de Meia-Idade , Análise de Sequência com Séries de Oligonucleotídeos , Pericárdio/imunologia , Pericárdio/cirurgia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Gordura Subcutânea/imunologia , Gordura Subcutânea/metabolismo