J Clin Pathol ; 34(5): 486-94, 1981 May.
Artigo em Inglês | MEDLINE | ID: mdl-7251891

RESUMO

A patient with angioimmunoblastic lymphadenopathy, immunoblastic leukaemia, pulmonary immunoblastic infiltration, and multiple antihaemocytic antibodies in his serum deteriorated rapidly after chemotherapy due to severe progressive respiratory of dysfunction. The haematological and immunological changes that accompanied this are described and discussed in the light of the pulmonary changes observed at necropsy of pulmonary oedema, fibrinous thrombi within venules, and immunoblastic infiltration of these thrombi and the venule walls. A pathophysiological mechanism is postulated in an attempt to rationalise these findings, and to act as a guide for the future assessment and management of similar cases.


Assuntos
Células Sanguíneas/imunologia , Linfadenopatia Imunoblástica/complicações , Leucemia/complicações , Insuficiência Respiratória/etiologia , Humanos , Linfadenopatia Imunoblástica/tratamento farmacológico , Linfadenopatia Imunoblástica/imunologia , Leucemia/imunologia , Masculino , Pessoa de Meia-Idade
2.
Thromb Res ; 51(4): 425-37, 1988 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-3187965

RESUMO

This preliminary study documents two new functional relationships for platelets obtained from normal subjects, whose individual blood platelet concentrations (IBPCs) are in the normal range. Firstly, platelets from subjects (or donors) with high-normal IBPCs are the least sensitive to collagen-induced aggregation (a significant inverse correlation). This may be of importance in determining the likely efficacy of fresh platelet transfusions obtained from donors with different IBPCs within the normal range. Secondly, platelets from subjects/donors with high-normal IBPCs deteriorate less rapidly during storage (a significant inverse correlation), perhaps due to differences in platelet biochemical activity between individuals. Such measurements of platelet deterioration rate were based upon the development of a new experimental technique, in which sterile test-PRP was incubated at 37 degrees C with continuous (quarter-hourly) indirect measurements of changes in platelet morphology. This tube-based method is described in detail. The functional relationships observed do have a theoretical basis within the work of others, which is appopriately outlined. Particular discussion pivots around the possibility of using the deterioration rate relationship to predict how therapeutic platelet concentrates prepared from a given donor of know IBPC, may retain their morphological integrity during routine blood bank storage.


Assuntos
Colágeno/farmacologia , Agregação Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Adolescente , Adulto , Preservação de Sangue , Humanos , Técnicas In Vitro , Masculino
3.
Clin Chim Acta ; 65(1): 139-42, 1975 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-1192604

RESUMO

Plasma glucose responses to 50 g oral glucose loads were measured in 17 young healthy males during the morning and the afternoon after 4-h and 12-h fasts. After 4-h fasts certain glucose response values correlated significantly with the basal glucose values (P less than 0.014) in both the morning and the afternoon tests, and are described as "fast-dependent" relationships. No significant correlations were found after 12 -h fasts either in the morning or the afternoon. The "fast-dependent" relationships are also "time-modified", as demonstrated by markedly different morning and afternoon regression equations.


Assuntos
Glicemia/análise , Glucose/administração & dosagem , Administração Oral , Adulto , Glicemia/metabolismo , Jejum , Humanos , Cinética , Masculino , Fatores de Tempo
4.
Blood Coagul Fibrinolysis ; 3(5): 621-3, 1992 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1450328

RESUMO

The clinical demand for platelet concentrates has increased dramatically in the last decade, and poses logistical problems for regional transfusion centres. Pietersz et al. (Vox Sang 1989; 56: 145-150) have shown that it is possible to prepare clinically effective platelet concentrates with substantially reduced white cell contamination, whilst maintaining satisfactory levels of factor VIII:C after holding whole blood at 20 degrees C overnight. This approach offers a method of production that will allow platelet concentrates to be prepared from potentially all donations collected, without resorting to extensive out-of-hours working. Following laboratory evaluation of the procedure we were able to reproduce Pietersz's findings, although hypotonic shock response results were less favourable than observed in our routine platelet concentrates.


Assuntos
Temperatura Baixa , Plaquetoferese/métodos , Humanos , Manejo de Espécimes , Tempo
5.
Ultrasound Med Biol ; 13(4): 183-95, 1987 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3590365

RESUMO

Discoid platelet suspensions were subjected to ultrasonic fields, in the 1-10 MHz frequency range and at estimated acoustic pressures in the range of 0.05-7.6 X 10(4) Pa. Absolute definition of the acoustic field/pressures was precluded by the small dimensions, and internal reflective surfaces, of the experimental configurations employed. Direct microscopy revealed platelet flow, in patterns consistent with theory for ultrasonically induced streaming. This ultrasonic effect was presumed to be accompanied by platelet orientation since it could be quantitated by simultaneous light transmission measurements. The preliminary characterisation of this phenomenon, defined as ultrasound induced light transmission change (USILTC) is reported, and indicates that it may be readily quantitated in a reproducible manner, but which shows a complex relationship both to pressure and frequency. In addition, qualitative characteristics of the response traces are apparent under certain conditions, particularly 5 MHz above 1 X 10(4) Pa, and may relate to platelet viability. Preliminary evidence is provided and discussed, which suggests that USILTC may be a useful model for studying certain ultrasound bioeffects, and may be a useful tool for indirectly assessing platelet morphology and viability for quality assurance purposes.


Assuntos
Plaquetas/fisiologia , Luz , Ultrassom , Fenômenos Biofísicos , Biofísica , Preservação de Sangue , Calibragem , Sobrevivência Celular , Humanos , Métodos , Suspensões , Temperatura , Transdutores , Ultrassom/instrumentação
6.
Ultrasound Med Biol ; 13(4): 197-208, 1987 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3590366

RESUMO

Discoid platelets were directionally orientated using stirring or ultrasound, and the change from random orientation was measured by light transmission. Stirring-induced light transmission change (SILTC), already well established as a good indirect indicator of platelet morphology, was compared with ultrasound-induced light transmission change (USILTC) in order to determine whether USILTC may be a similarly good indicator of platelet morphology. Numerous direct comparisons were made between SILTC and USILTC at various static temperatures, and during the dynamic thermal transitions of warming and cooling. Good correlation exists between quantitated SILTC and USILTC values, but the relationship is not exact. Furthermore, single stirring events may considerably distort the relationship under certain conditions. At the ultrasound frequency of 5 MHz and at an estimated peak positive pressure of 2.03 X 10(4) Pa, the USILTC response patterns exhibit a qualitative "spike" pattern for unfixed platelets, which disappears following glutaraldehyde fixation. These preliminary findings are described and discussed in detail, since they suggest that USILTC is a better index of platelet viability than SILTC, although much research is still required in this area.


Assuntos
Plaquetas/fisiologia , Luz , Ultrassom , Fenômenos Biofísicos , Biofísica , Plaquetas/citologia , Preservação de Sangue , Sobrevivência Celular , Humanos , Métodos , Suspensões , Temperatura , Ultrassom/instrumentação
7.
Qual Manag Health Care ; 5(4): 43-52, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-10169784

RESUMO

As clinical transfusion practice works towards achieving cost-effectiveness, prescribers of blood and its derivatives must be certain that the prices of such products are based on real manufacturing costs and not market forces. Using clinical cost-benefit analysis as the context for the costing and pricing of blood products, this article identifies the following two principles: (1) the product price must equal the product cost (the "price = cost" rule) and (2) the product cost must equal the real cost of product manufacture. In addition, the article describes a new method of blood product costing, quality-associated costing (QAC), that will enable valid cost-benefit analysis of blood products.


Assuntos
Transfusão de Sangue/economia , Alocação de Custos/métodos , Administração de Linha de Produção/economia , Garantia da Qualidade dos Cuidados de Saúde/economia , Contabilidade/métodos , Transfusão de Sangue/normas , Análise Custo-Benefício , Inglaterra , Humanos , Modelos Econométricos , País de Gales
8.
Qual Manag Health Care ; 5(4): 53-65, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-10169785

RESUMO

This article applies the new method of quality-associated costing (QAC) to the mixture of processes that create red cell and plasma products from whole blood donations. The article compares QAC with two commonly encountered but arbitrary models and illustrates the invalidity of clinical cost-benefit analysis based on these models. The first, an "isolated" cost model, seeks to allocate each whole process cost to only one product class. The other is a "shared" cost model, and it seeks to allocate an approximately equal share of all process costs to all associated products.


Assuntos
Transfusão de Sangue/economia , Alocação de Custos/métodos , Administração de Linha de Produção/economia , Garantia da Qualidade dos Cuidados de Saúde/economia , Contabilidade/métodos , Transfusão de Sangue/normas , Análise Custo-Benefício , Eritrócitos , Humanos , Indústrias/economia , Modelos Econométricos , Plasma , Reino Unido
9.
Qual Manag Health Care ; 8(1): 64-74, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10662105

RESUMO

Realistic estimates about the potential misallocation of health service resources, in relation to the cost-beneficial use of blood products, is enabled by tracing manufacturing costs, through product specification elements to corresponding post-transfusion outcomes. This quality-associated costing (QAC) philosophy is completed in this article by understanding the issues that surround the manufacture of platelets, and by its comparison with the generally used but arbitrary methods for blood product costing. Without QAC, cost-beneficial platelet therapy will not be realized, due to an estimated Western underfunding of approximately one quarter of a billion pounds per annum by arbitrary methods. A reciprocal consequence of such platelet QAC is a significant reduction in the currently perceived cost of source plasma. Western estimates, based upon this, demonstrate that the not-for-profit fractionation of source plasma into purified proteins is probably underfunded by approximately one fifth of a billion pounds per annum through the use of arbitrary costing methods.


Assuntos
Análise Custo-Benefício/métodos , Alocação de Recursos para a Atenção à Saúde/métodos , Transfusão de Plaquetas/economia , Plaquetoferese/economia , Administração de Linha de Produção/economia , Bancos de Sangue/economia , Bancos de Sangue/normas , Doadores de Sangue , Alocação de Recursos para a Atenção à Saúde/economia , Pesquisa sobre Serviços de Saúde , Humanos , Administração de Linha de Produção/normas , Controle de Qualidade , Resultado do Tratamento , Estados Unidos
10.
J Med Eng Technol ; 12(2): 47-53, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3398027

RESUMO

This methodological report documents the electro-mechanical modifications that were applied to a commercially available aggregometer, in order to achieve direct platelet aggregation measurement at sub-ambient temperatures. This development provides a facility, not previously available, for examining certain aspects of platelet physiology at any desired temperature. This innovation was primarily developed for investigating optimum storage parameters for platelets, as they apply to clinical blood transfusion practice. However, a wider scope of application is envisaged, including its use as both a general research tool, and eventually as an additional component of clinical measurement in the routine coagulation laboratory. Some illustrative data is briefly provided.


Assuntos
Agregação Plaquetária , Temperatura Baixa , Desenho de Equipamento , Humanos , Técnicas In Vitro , Óptica e Fotônica , Agregação Plaquetária/efeitos dos fármacos , Manejo de Espécimes
11.
J Med Eng Technol ; 16(6): 250-8, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1300379

RESUMO

A cylindrical device is described for placement within a domestic microwave oven, in order to achieve rapid thawing of biological materials, including plasma, located within the cylinder. The device is economical to fabricate within standard workshop facilities. It secures uniform microwave exposure and continuous mixing of material by rotation of the cylinder in two planes, entraining the motion of the oven drive spindle by a very simple system of frictional gears. Data are presented on the accuracy of this system, and on some important points relating to its use both as a calibration model and a research tool. Such research may eventually enable this system to provide a cheap and reliable option for thawing therapeutic materials for clinical use.


Assuntos
Micro-Ondas , Modelos Biológicos , Preservação de Tecido/métodos , Calibragem , Criopreservação , Desenho de Equipamento
12.
Transfus Sci ; 14(3): 309-17, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10146343

RESUMO

For mixed apheresis procedures {plasma (PMA) and platelets (PLTs) as products}, six cost-accounting methods are described for apportioning the unit procedure cost ($156.02; representative example) to the two products. The methods are derived from clinical/scientific apheresis principles, but provide a wide range of unit PLT costs ($14.10, 19.71, 34.37, 42.06, 43.82 and 52.00) which relate inversely to the corresponding unit PMA costs ($73.84, 63.01, 34.36, 19.37, 15.94 and 0.00). Two of the methods appear particularly appropriate, depending upon whether the procedure is driven by PLTs predominantly or by PMA+PLTs equally. The paper encourages apheresis physicians and scientists to debate the relative attributes of the methods, develop refinements of the same, and determine through dialogue that mixed apheresis costing models properly account for the clinical science of the service provided.


Assuntos
Plasmaferese/economia , Plaquetoferese/economia , Contabilidade , Custos e Análise de Custo , Humanos , Plasmaferese/métodos , Plaquetoferese/métodos , Métodos de Controle de Pagamentos
13.
Vox Sang ; 51(3): 185-91, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3811317

RESUMO

A commercially available aggregometer was mechanically and electronically modified to enable automatic repeated measurements of platelet morphology for platelet suspensions undergoing prolonged storage within a sealed perspex cuvette, at any temperature. The modifications are described in sufficient detail to enable others to readily produce the same or similar apparatus. Representative experiments with such apparatus are described, and indicate its potential usefulness in defining the rate of change of platelet morphology occurring during storage at any given temperature, e.g. progressive alteration of shear-induced light transmission change values.


Assuntos
Plaquetas/citologia , Preservação de Sangue , Plaquetas/fisiologia , Humanos , Métodos , Monitorização Fisiológica , Agregação Plaquetária , Temperatura
14.
Haemostasis ; 16(5): 352-61, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3781350

RESUMO

A specifically modified commercially available aggregometer, referred to as a sub-ambient aggregometer, was used to measure certain parameters of platelet function throughout the temperature range of 4-37 degrees C. Platelet aggregation responses to ADP and stirring (spontaneous aggregation) were found to be maximal at room temperature. The possible relevance of this to routine platelet storage is discussed. Shear-induced light transmission change (SILTC) as a quick, repeatable, non-invasive index of platelet morphology was used to monitor small-sample platelet storage at 4 degrees C and during its subsequent resuscitation at 37 degrees C. This confirmed the combined usefulness of the sub-ambient aggregometer and SILTC measurements for monitoring platelets during storage. Further application of this approach should enable the optimum temperature for the liquid storage of platelets to be defined, which may not necessarily be 22 degrees C as usually employed.


Assuntos
Preservação de Sangue , Agregação Plaquetária , Difosfato de Adenosina/farmacologia , Adolescente , Adulto , Humanos , Técnicas In Vitro , Agregação Plaquetária/efeitos dos fármacos , Temperatura
15.
Health Care Manage Rev ; 21(2): 7-15, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8860036

RESUMO

This study examines the nature of the problems caused by costing activities which focus on isolated treatments. The possible misallocation of resources is identified and a solution which accounts for full treatment until cure is postulated.


Assuntos
Alocação de Custos/métodos , Cuidado Periódico , Modelos Econômicos , Avaliação de Processos e Resultados em Cuidados de Saúde/economia , Custos de Cuidados de Saúde , Alocação de Recursos para a Atenção à Saúde , Humanos , Qualidade da Assistência à Saúde/economia , Reprodutibilidade dos Testes , Falha de Tratamento , Resultado do Tratamento
16.
Clin Phys Physiol Meas ; 10(1): 65-74, 1989 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2714061

RESUMO

Studies of platelet aggregation are normally performed at 37 degrees C. However, in hypothermia during certain surgical procedures (for example, cardiopulmonary bypass) efficient aggregation may be needed at temperatures below 37 degrees C: therefore, assessment of platelet aggregation at temperatures below 37 degrees C may be relevant. This paper describes a sub-ambient aggregometry system developed for this purpose. The effect of temperature (range of 4.5 degrees-37.0 degrees C) upon ADP-induced and spontaneous aggregation of platelets from normal subjects was studied. Platelet aggregation was found to be maximal at room temperature, and may represent 'pure' aggregation. At higher temperatures platelet disaggregation becomes measurable, and at lower temperatures, cold-induced platelet shape-change predominates. These parameters are briefly discussed in terms of their relevance to future research into the physiology of platelet storage and clinical haemostasis.


Assuntos
Plaquetas/fisiologia , Hipotermia Induzida , Agregação Plaquetária , Difosfato de Adenosina/farmacologia , Plaquetas/efeitos dos fármacos , Humanos , Métodos , Temperatura
17.
Transfus Med ; 5(3): 231-40, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8593529

RESUMO

Detailed information is provided about primary product costing and price issues as they affect transfusion manufacturing practice and clinical transfusion practice. Product price is shown to have a crucial influence upon clinical practice and associated research. By focusing particularly upon cost-benefit analysis of blood product transfusion therapy a substantive conclusion is drawn that price should equal the associated manufacturing cost. Clinical outcome studies relate clinical efficacy to the manufacturing specification of the product, which should therefore determine the product cost. Thus, the true manufacturing cost is the sum of all the process activity costs that create the final product specification, e.g. red cell number+volume reduction+leucocyte reduction+microbiological safety, for processed red cells. Sometimes different product specifications may compete for a single activity cost, e.g. one-spin processing achieves volume reduction and leucocyte reduction for processed red cells but also plasma removal for protein fractionation. A method for understanding the relative clinical importance of different products is described, which guides the cost allocation process. Furthermore, for some products there is uncertainty about the clinical benefits of some components of the specification, e.g. leucocyte load and immunomodulation, and a method is described for ranking this quality-uncertainty level objectively. The optimal costing model must ensure that the product with the highest uncertainty ranking is assured a high degree of cost stability. These concepts prepare the way for a Quality Associated Costing model for blood products that correlates with clinical efficacy.


Assuntos
Transfusão de Sangue/economia , Análise Custo-Benefício , Custos e Análise de Custo , Transfusão de Eritrócitos/economia , Humanos , Plasma , Transfusão de Plaquetas/economia , Controle de Qualidade
18.
Br Med J ; 2(5920): 640-2, 1974 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-4835442

RESUMO

In a group of healthy young male volunteers a worsened tolerance to oral glucose in the afternoon after a four-hour fast was reversed by a 12-hour fast. The latter also produced consistent mild hypoglycaemia from two and a half to four hours after the glucose loading irrespective of the time of day.


Assuntos
Glicemia/análise , Ritmo Circadiano , Jejum , Adulto , Teste de Tolerância a Glucose , Humanos , Masculino , Fatores de Tempo
19.
Vox Sang ; 48(2): 65-71, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-3934842

RESUMO

A microwave oven has been used to obtain rapid and controlled thawing of frozen plasma packs for cryoprecipitate production. The resulting factor VIII yields were higher than the average of 77.8 IU (in a volume of 17.2 ml) obtained by the slow overnight thaw procedures in routine use. Assays on 10 individual packs showed mean results of 142 +/- 24.5 IU factor VIII procoagulant activity, 188.6 +/- 51.68 IU factor VIII-related antigen, 0.152 +/- 0.05 g fibrinogen and 218.9 +/- 66.5 IU fibronectin in a volume of 23.2 +/- 6.6 ml. The results of this preliminary study indicate that microwave thawing of plasma is worthy of further investigation and should be reconsidered for routine production of cryoprecipitate and high yield fibronectin.


Assuntos
Fator VIII/isolamento & purificação , Fibrinogênio/isolamento & purificação , Micro-Ondas , Plasma/análise , Antígenos/análise , Precipitação Química , Fator VIII/análise , Fator VIII/imunologia , Fibrinogênio/análise , Fibronectinas/análise , Congelamento , Humanos , Plasma/efeitos da radiação , Fator de von Willebrand
20.
Postgrad Med J ; 53(621): 391-3, 1977 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-882480

RESUMO

Leuco-erythroblastosis has many known associations (Burkett, Cox and Fields, 1965; Weick, Hagedorn and Linman, 1974; Retief, 1964), but the only ones related to drug therapy are the well established response to haematinics (Burkett et al., 1965) and one possible case following anti-epileptic therapy (Retief, 1964). The case described below is of leuco-erythroblastosis following steroid withdrawal in a young man with primary polymyositis.


Assuntos
Anemia Mielopática/etiologia , Dexametasona , Síndrome de Abstinência a Substâncias/complicações , Adulto , Dexametasona/uso terapêutico , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS