1.
J Med Internet Res ; 24(4): e30236, 2022 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-35468091

RESUMO

BACKGROUND: Smartphone compatible wearables have been released on the consumers market, enabling remote monitoring. Remote monitoring is often named as a tool to reduce the cost of care. OBJECTIVE: The primary purpose of this paper is to describe a cost-utility analysis of an eHealth intervention compared to regular follow-up in patients with acute myocardial infarction (AMI). METHODS: In this trial, of which clinical results have been published previously, patients with an AMI were randomized in a 1:1 fashion between an eHealth intervention and regular follow-up. The remote monitoring intervention consisted of a blood pressure monitor, weight scale, electrocardiogram device, and step counter. Furthermore, two in-office outpatient clinic visits were replaced by e-visits. The control group received regular care. The differences in mean costs and quality of life per patient between both groups during one-year follow-up were calculated. RESULTS: Mean costs per patient were €2417±2043 (US $2657±2246) for the intervention and €2888±2961 (US $3175±3255) for the control group. This yielded a cost reduction of €471 (US $518) per patient. This difference was not statistically significant (95% CI -€275 to €1217; P=.22, US $-302 to $1338). The average quality-adjusted life years in the first year of follow-up was 0.74 for the intervention group and 0.69 for the control (difference -0.05, 95% CI -0.09 to -0.01; P=.01). CONCLUSIONS: eHealth in the outpatient clinic setting for patients who suffered from AMI is likely to be cost-effective compared to regular follow-up. Further research should be done to corroborate these findings in other patient populations and different care settings. TRIAL REGISTRATION: ClinicalTrials.gov NCT02976376; https://clinicaltrials.gov/ct2/show/NCT02976376. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/resprot.8038.


Assuntos
Infarto do Miocárdio , Telemedicina , Instituições de Assistência Ambulatorial , Análise Custo-Benefício , Seguimentos , Humanos , Infarto do Miocárdio/terapia , Qualidade de Vida
2.
Eur Heart J Digit Health ; 4(4): 347-356, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37538141

RESUMO

Aims: Lowering low-density lipoprotein (LDL-C) and blood pressure (BP) levels to guideline recommended values reduces the risk of major adverse cardiac events in patients who underwent coronary artery bypass grafting (CABG). To improve cardiovascular risk management, this study evaluated the effects of mobile health (mHealth) on BP and cholesterol levels in patients after standalone CABG. Methods and results: This study is a post hoc analysis of an observational cohort study among 228 adult patients who underwent standalone CABG surgery at a tertiary care hospital in The Netherlands. A total of 117 patients received standard care, and 111 patients underwent an mHealth intervention. This consisted of frequent BP and weight monitoring with regimen adjustment in case of high BP. Primary outcome was difference in systolic BP and LDL-C between baseline and value after three months of follow-up. Mean age in the intervention group was 62.7 years, 98 (88.3%) patients were male. A total of 26 449 mHealth measurements were recorded. At three months, systolic BP decreased by 7.0 mmHg [standard deviation (SD): 15.1] in the intervention group vs. -0.3 mmHg (SD: 17.6; P < 0.00001) in controls; body weight decreased by 1.76 kg (SD: 3.23) in the intervention group vs. -0.31 kg (SD: 2.55; P = 0.002) in controls. Serum LDL-C was significantly lower in the intervention group vs. controls (median: 1.8 vs. 2.0 mmol/L; P = 0.0002). Conclusion: This study showed an association between home monitoring after CABG and a reduction in systolic BP, body weight, and serum LDL-C. The causality of the association between the observed weight loss and decreased LDL-C in intervention group patients remains to be investigated.

3.
JMIR Cardio ; 5(2): e26072, 2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34642159

RESUMO

BACKGROUND: Mobile health (mHealth) is an emerging field of scientific interest worldwide. Potential benefits include increased patient engagement, improved clinical outcomes, and reduced health care costs. However, mHealth is often studied in projects or trials, and structural implantation in clinical practice is less common. OBJECTIVE: The purpose of this paper is to outline the design of the Box and its implementation and use in an outpatient clinic setting. The impact on logistical outcomes and patient and provider satisfaction is discussed. METHODS: In 2016, an mHealth care track including smartphone-compatible devices, named the Box, was implemented in the cardiology department of a tertiary medical center in the Netherlands. Patients with myocardial infarction, rhythm disorders, cardiac surgery, heart failure, and congenital heart disease received devices to measure daily weight, blood pressure, heart rate, temperature, and oxygen saturation. In addition, professional and patient user comments on the experience with the care track were obtained via structured interviews. RESULTS: From 2016 to April 2020, a total of 1140 patients were connected to the mHealth care track. On average, a Box cost €350 (US $375), not including extra staff costs. The median patient age was 60.8 (IQR 52.9-69.3) years, and 73.59% (839/1140) were male. A median of 260 (IQR 105-641) measurements was taken on a median of 189 (IQR 98-372) days. Patients praised the ease of use of the devices and felt more involved with their illness and care. Professionals reported more productive outpatient consultations as well as improved insight into health parameters such as blood pressure and weight. A feedback loop from the hospital to patient to focus on measurements was commented as an important improvement by both patients and professionals. CONCLUSIONS: In this study, the design and implementation of an mHealth care track for outpatient follow-up of patients with various cardiovascular diseases is described. Data from these 4 years indicate that mHealth is feasible to incorporate in outpatient management and is generally well-accepted by patients and providers. Limitations include the need for manual measurement data checks and the risk of data overload. Moreover, the tertiary care setting in which the Box was introduced may limit the external validity of logistical and financial end points to other medical centers. More evidence is needed to show the effects of mHealth on clinical outcomes and on cost-effectiveness.

4.
JMIR Cardio ; 3(1): e9894, 2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-31758786

RESUMO

BACKGROUND: Polysomnography is the gold standard for detection of central sleep apnea in patients with stable heart failure. However, this procedure is costly, time consuming, and a burden to the patient and therefore unsuitable as a screening method. An electronic health (eHealth) app to measure overnight oximetry may be an acceptable screening alternative, as it can be automatically analyzed and is less burdensome to patients. OBJECTIVE: This study aimed to assess whether overnight pulse oximetry using a smartphone-compatible oximeter can be used to detect central sleep apnea in a population with stable heart failure. METHODS: A total of 26 patients with stable heart failure underwent one night of both a polygraph examination and overnight saturation using a smartphone-compatible oximeter. The primary endpoint was agreement between the oxygen desaturation index (ODI) above or below 15 on the smartphone-compatible oximeter and the diagnosis of the polygraph. RESULTS: The median age of patients was 66.4 (interquartile range, 62-71) years and 92% were men. The median body mass index was 27.1 (interquartile range, 24.4-30.8) kg/m2. Two patients were excluded due to incomplete data, and two other patients were excluded because they could not use a smartphone. Seven patients had central sleep apnea, and 6 patients had obstructive sleep apnea. Of the 7 (of 22, 32%) patients with central sleep apnea that were included in the analysis, 3 (13%) had an ODI≥15. Of all patients without central sleep apnea, 8 (36%) had an ODI<15. The McNemar test yielded a P value of .55. CONCLUSIONS: Oxygen desaturation measured by this smartphone-compatible oximeter is a weak predictor of central sleep apnea in patients with stable heart failure.

5.
JMIR Res Protoc ; 6(9): e186, 2017 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-28939546

RESUMO

BACKGROUND: Recent evidence suggests that frequent monitoring using smartphone-compatible wearable technologies might improve clinical effectiveness and patient satisfaction of care. OBJECTIVE: The aim of this study is to investigate the clinical effectiveness and patient satisfaction of a smart technology intervention in patients admitted with a ST elevation myocardial infarction (STEMI) or non-ST acute coronary syndrome (NST-ACS). METHODS: In this single center, open, randomized controlled trial patients who suffered from STEMI or NST-ACS will be randomized 1:1 to an intervention group or control group. Both groups will be followed up to one year after the index event. The intervention group will take daily measurements with a smartphone-compatible electrocardiogram device, blood pressure (BP) monitor, weight scale, and activity tracker. Furthermore, two of four outpatient clinic visits will be replaced by electronic visits (1 and 6 months after index event). The control group will receive regular care, consisting of four outpatient clinic visits (1, 3, 6, and 12 months after index event). All patients will be asked to fill in validated questionnaires about patient satisfaction, quality of life, propensity of medication adherence, and physical activity. RESULTS: The primary outcome of this trial will be percentage of patients with controlled BP. Secondary outcomes include patient satisfaction, health care utilization, major adverse cardiac events, medication adherence, physical activity, quality of life, and percentage of patients in which a sustained arrhythmia is detected. CONCLUSIONS: Smart technology could potentially improve care in postmyocardial infarction patients. This trial will investigate whether usage of smart technology can improve clinical- and cost-effectiveness of care. TRIAL REGISTRATION: Clinicaltrials.gov NCT02976376; https://clinicaltrials.gov/ct2/show/NCT02976376 (Archived by WebCite at http://www.webcitation.org/6tcvAdbdH).

6.
Expert Rev Med Devices ; 13(9): 823-30, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27477584

RESUMO

INTRODUCTION: Recent developments in implantable cardioverter-defibrillators (ICDs) and smartphone technology have increased the possibilities for remote monitoring. It is the purpose of this review to give an overview of these new possibilities. AREAS COVERED: Remote monitoring in ICD allows for early detection of lead fractures and remote follow-up of patients. Possible limitations are the lack of standardization and the possible unsafety of the data stored on the ICD. Secondly, remote monitoring of health parameters using smartphone compatible wearables and smartphone medical apps is addressed. Possible limitations include the fact that the majority of smartphone apps are unregulated by the regulatory authorities and privacy issues such as selling of app-generated data to third parties. Lastly, clinical studies with smartphone apps are discussed. Expert commentary: New technologies in ICDs and smartphones have the potential to be used for remote monitoring. However, unreliability of smartphone technology, inadequate legislation and lack of reimbursement impede implementation.


Assuntos
Cardiologia/instrumentação , Aplicativos Móveis , Monitorização Fisiológica/instrumentação , Telemedicina/instrumentação , Humanos , Legislação como Assunto