Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Kyobu Geka ; 77(1): 22-26, 2024 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-38459841

RESUMO

OBJECTIVE: In an effort to avoid postoperative sick sinus syndrome( SSS), we omit the ablation line to the superior vena cava( SVC) in the Cox-mazeⅢ lesion set. We report the long-term outcomes, including the freedom from SSS. METHODS: We studied 102 patients who underwent bi-atrial maze procedure for persistent atrial fibrillation (Af) from 2009 through 2023. Bipolar radio frequency ablation or cryoablation was used except for right-side atriotomy and right atriotomy. Cryoablation was used for atrioventricular annulus. The patient age was 68±9.4. Duration of Af was 3.4±6.5 years (unknown 9 cases). The amplitude of f-wave in V1 was 0.182±0.095 mV and it was<0.1 mV in 19 (18.6%). Diameter of the left atrium was 50±8.9 mm, and left atrial volume index was 89±37 ml/m2. Ninety-one (89.2%) patients underwent concomitant mitral valve surgery. RESULTS: Survival rate was 99% at 1 year and 96% at 5 years. Freedom from Af was 92% at 1 year and 88% at 5 years. Freedom from permanent pacemaker implantation (PPI) was 87% at 1 year and 83% at 5 years. CONCLUSIONS: Defibrillation rate and the incidence of PPI was comparable to those in previous reports after standard Cox-mazeⅢ. SSS after maze for persistent Af seem due to patient.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Veia Cava Superior/cirurgia , Procedimento do Labirinto , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/métodos
2.
Ann Vasc Surg ; 33: 230.e1-4, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26907373

RESUMO

In Behcet disease (BD), vascular complication such as false aneurysm formation is common after surgical treatment in the arterial lesion, and the optimal treatment method remains controversial. Concerning the innominate artery aneurysm, lack of experience due to its rarity in vasculo BD makes decision making even more difficult. We report a ruptured innominate artery aneurysm in a 70-year-old man with BD, which was successfully treated by innominate artery stent grafting through the right common carotid artery, axillo-axillary artery bypass grafting, and right subclavian artery coil embolization. The patient is doing well without any vascular complications at eighth postoperative month.


Assuntos
Aneurisma Roto/terapia , Síndrome de Behçet/complicações , Implante de Prótese Vascular , Tronco Braquiocefálico/cirurgia , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Síndrome de Behçet/diagnóstico , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Tronco Braquiocefálico/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Kyobu Geka ; 67(8): 630-5, 2014 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-25138930

RESUMO

Somatosensory evoked potential (SSEP), evoked spinal cord potential (ESCP) and motor evoked potential (MEP) have been used to detect spinal cord ischemia during aortic surgery. SSEP evaluates the sensory pathway, and is recorded from the sensory cortex by peripheral nerve stimulation. The interval from the onset of ischemia to change is relatively long(5-10 minutes). It has less frequently been used because of the high false negative and false positive rate. ESCP is recorded from the spinal cord by direct stimulation of the cord. It reflects the function of spinal tract but not that of alpha motor neurons. It is resistant to anesthesia and both the sensitivity and specificity is high, but the interval from ischemia to change is relatively long. Together with the necessity of 2 epidural electrodes, its application in aortic surgery has become infrequent. Since the introduction of train pulse transcranial electrical stimulation, myogenic MEP have gained widespread acceptance. It evaluates motor pathways from the cortex to the muscle, and therefore is influenced by non-spinal factors such as peripheral nerve ischemia. Its vulnerability to anesthesia requires special anesthetic consideration, and baseline amplitude fluctuation is common. It is highly sensitive and shows changes in the early phase of spinal cord ischemia.


Assuntos
Aorta/cirurgia , Potencial Evocado Motor , Potenciais Somatossensoriais Evocados , Potenciais Evocados , Complicações Intraoperatórias/diagnóstico , Monitorização Neurofisiológica/métodos , Isquemia do Cordão Espinal/diagnóstico , Medula Espinal/fisiologia , Anestesia Geral , Humanos , Complicações Intraoperatórias/prevenção & controle , Nervos Periféricos/fisiologia , Córtex Somatossensorial/fisiologia , Isquemia do Cordão Espinal/prevenção & controle , Estimulação Transcraniana por Corrente Contínua , Procedimentos Cirúrgicos Vasculares
4.
Gen Thorac Cardiovasc Surg ; 72(3): 202-205, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37882902

RESUMO

Stabilizing the aorto-ventricular junction is integral in aortic valve repair. We report our technique of internal circular suture annuloplasty. We used a continuous horizontal mattress suture of a single thick expanded polytetrafluoroethylene suture (CV-3). We put 4 stitches per sinus, so the suture was below the cusp attachment line at the nadirs and passed through the interleaflet triangle at the upper aorto-ventricular junction level. The suture was reinforced with pericardial pledgets on both sides of each commissure. We used this technique in 12 patients. The diameter of aorto-ventricular junction was reduced from 25 ± 2 mm to 22 ± 1 mm (n = 11) and was 22 ± 1 mm at the latest follow-up (4-74 months, median 41, n = 10). In 2 patients with large aorto-ventricular junction (27 mm or more), expected annular reduction was not achieved. Our modified technique is simple and seems durable. It may be useful for mild annular dilatation.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Valva Tricúspide/cirurgia , Suturas , Técnicas de Sutura , Resultado do Tratamento
5.
Kyobu Geka ; 66(6): 469-72, 2013 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-23917051

RESUMO

We report a case of an adult coarctation of aorta in a 46-year-old woman repaired with partial selective cerebral perfusion. Preoperative cardiac catheterization revealed that pressure gradient between the upper and lower limb was more than 60 mmHg. Under general anesthesia, we entered the left thoracic cavity through standard thoracomy, and removed the coarctation of aorta under partial selective cerebral circulation. The left common carotid artery and the descending aorta were cannulated and perfused, and the main pulmonary artery was cannulated for venous drainage. The aortic arch was cross-clamped just proximal to the left common carotid artery. Reconstruction was carried out by graft replacement using a side armed 16 mm Dacron graft between the aortic arch and the descending aorta, and the left subclavian artery was connected to the side arm of the graft. Postoperatively, there is no pressure difference between the upper and lower extremities.


Assuntos
Coartação Aórtica/cirurgia , Circulação Cerebrovascular , Circulação Extracorpórea/métodos , Implante de Prótese Vascular , Feminino , Humanos , Pessoa de Meia-Idade
6.
Ann Thorac Cardiovasc Surg ; 29(1): 1-10, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36104188

RESUMO

Single-stage extended replacement from the ascending to the distal descending aorta or beyond is a formidable operation that should be preserved for those who have no other option or those who are physically fit, and should be performed in the experienced centers. Hybrid operations combining open surgical repair with thoracic endovascular aortic repair through a median sternotomy incision are preferable because these operations are less invasive than the extended open aortic repair and the risk of spinal cord ischemia is lower compared with the frozen elephant trunk operation. However, these operations are associated with the inherent demerits of endovascular aneurysm exclusion. When the underlying aortic pathology necessitates extended open aortic repair in a single stage, approaches such as the anterolateral partial sternotomy, straight incision with rib cross, and extended thoracotomy with sternal transection may be useful to provide sufficient exposure for both aortic reconstruction and organ protection, with less surgical stress to the patients.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Dissecção da Aorta Ascendente , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Esternotomia , Toracotomia
7.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-36688718

RESUMO

OBJECTIVES: Low patency is a major concern when using separate tube grafts for intercostal artery reconstruction. Our goal was to elucidate the optimal size and length of grafts from their patency and the computational fluid dynamics (CFD). METHODS: The patency, size and length of separate tube grafts were evaluated in 41 patients. Simulation of CFD was performed in a model derived from a patient with a patent 12-mm graft that was 15 mm long, with 2 simulation models with a smaller (8-mm) or longer (30-mm) graft. RESULTS: A total of 49 grafts were used for intercostal artery reconstruction. There was 1 in-hospital death and 2 spinal cord injuries. The patency rate, which could be evaluated in 46 grafts, was 63% (29/46). It was 71% (24/34) in thoracoabdominal aortic replacement and 42% (5/12) in descending aortic replacement. Among 14 patients in whom all grafts were occluded, no patients developed spinal cord injury. All grafts longer than 25 mm were occluded (n = 5). Eight- and 10-mm grafts showed better patency than 12-mm grafts in thoracoabdominal aortic replacement (P = 0.008) when grafts were shorter than 25 mm. Simulation of CFD revealed vortical flow within the 12-mm graft, which did not reach the intercostal orifice, whereas helical flow was maintained throughout the cardiac cycle within the 8-mm graft. CONCLUSIONS: Eight- and 10-mm grafts seemed better than 12-mm grafts, and grafts should be kept shorter than 25 mm. Simulation of CFD may shed light on the issue of the optimal intercostal artery reconstruction technique.


Assuntos
Aorta , Traumatismos da Medula Espinal , Humanos , Mortalidade Hospitalar , Aorta/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos
8.
Gen Thorac Cardiovasc Surg ; 71(1): 46-50, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35879630

RESUMO

OBJECTIVES: Sternal retractors utilized during open-heart surgeries through median sternotomy can cause upper rib fractures which sometimes further leads to brachial plexus injury. We aimed to investigate the incidence of brachial plexus injury and upper rib fractures in open-heart surgeries and how these injuries are associated with each other. METHODS: We investigated 1050 cases during the past five years. The incidence of brachial plexus injury and upper rib fractures after median sternotomy was assessed in all patients and the patients who sustained were evaluated for the affected side, the level of paralysis. RESULTS: Ten cases (0.95%) exhibited brachial plexus injury after median sternotomy. Nine cases developed paralysis on left upper extremity. In all ten cases, sensory and motor nerve impairment were exhibited in the lower plexus. Rib fractures were observed in 35.0% of cases after median sternotomy and the usage of asymmetric sternal retractors to harvest left internal thoracic artery (LITA) significantly affected the side of fracture. CONCLUSION: Sternal retractors utilized during open-heart surgeries through median sternotomy may cause rib fractures and brachial plexus injury, so operators should be aware of these complications.


Assuntos
Plexo Braquial , Procedimentos Cirúrgicos Cardíacos , Fraturas das Costelas , Humanos , Fraturas das Costelas/diagnóstico por imagem , Fraturas das Costelas/etiologia , Fraturas das Costelas/cirurgia , Esternotomia/efeitos adversos , Plexo Braquial/lesões , Plexo Braquial/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Paralisia/complicações
9.
Gen Thorac Cardiovasc Surg ; 70(10): 862-870, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35469364

RESUMO

OBJECTIVE: Although the radial artery graft has an adaptive property to flow demand, its flow characteristics in aorto-coronary sequential bypass grafting are not well elucidated. We evaluated the differences between the vein and radial artery grafts in the patency and the transit time flow meter-derived parameters (flow and pulsatile index), according to the stenosis rate of terminal target vessels and the number of anastomoses, in sequential bypass grafting to the left coronary territories as a second conduit. METHODS: We analyzed 222 patients who underwent isolated on-pump beating coronary artery bypass grafting with an aorto-coronary bypass to the left coronary territory. The patients were divided into radial artery group (n = 154) and vein graft group (n = 68). Sequential bypass was performed 1n 171 patients (127 radial arteries, 44 veins). RESULTS: Flow of the radial artery grafts was lower than that of the vein grafts (40.9 ± 22.3 vs 47.5 ± 23.8 mL/min, p = 0.044), while it became higher as the number of anastomoses per graft increased (1: 28.9 ± 16.3 vs 2: 40.9 ± 19.9 vs 3: 55.8 ± 27.5, p < 0.001). The patency of radial artery grafts was better than that of vein grafts (98.0% vs 92.6%, p = 0.010; p < 0.001 after propensity score weighting). CONCLUSIONS: Although intraoperative flow rate of the radial artery graft is lower, it has sufficient flow reserve for sequential bypass grafting, and its early patency is high enough. Radial artery is suitable for sequential bypass grafting to the left coronary territories as a second arterial conduit.


Assuntos
Artéria Radial , Veia Safena , Angiografia Coronária , Ponte de Artéria Coronária , Coração , Humanos , Artéria Radial/transplante , Veia Safena/transplante , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
Innovations (Phila) ; 17(4): 339-342, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35816370

RESUMO

We created a novel ring-type knot pusher with a closed triangle tip, wherein the thread is never detached from the knot pusher head during the ligation process. This knot pusher has a small head and is suitable for complex fields, such as the subvalvular apparatus of the mitral valve, allowing the surgeons to observe the knot itself. Considering that the thread passes through the inner corner of the triangle during the tying-down process without swinging inside the triangle, this knot pusher allows for a stable and secure ligation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgiões , Humanos , Ligadura , Procedimentos Cirúrgicos Minimamente Invasivos , Técnicas de Sutura
11.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36394268

RESUMO

OBJECTIVES: 18-Fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) has been reported as useful for diagnosing aortic graft infection. However, 18F-FDG uptake may depend upon various factors including open versus endovascular repair and time from surgery. We aimed to elucidate the factors influencing its uptake and the diagnostic value of 18F-FDG PET/CT after open and endovascular repair. METHODS: Hospital database of PET/CT (N = 14 490) and our departmental database were cross-checked to identify those who underwent 18F-FDG PET/CT after aortic repair. Patient's data were retrieved from the chart. Images were reviewed by 2 nuclear medicine specialists in consensus, and the presence of increased 18F-FDG uptake was recorded. The maximum standardized uptake value (SUV max) was measured. RESULTS: Among the 1112 patients who underwent aortic repair between 2011 and 2022, 71 patients were identified. Eighteen patients underwent 18F-FDG PET/CT for suspected graft infection and the remaining 53 patients for other purposes (malignancy, etc.). Fourteen patients were treated as aortic graft infection. They had significantly higher SUV max than those without graft infection [mean 8.64 (standard deviation 2.78) vs 3.40 (standard deviation 0.84); P < 0.01]. In the non-infected grafts, SUV max was higher early after open surgical repair, while it remained low after endovascular repair. CONCLUSIONS: After endovascular aortic repair, a constant cut-off value of 'SUV max = 4.5' seems appropriate for diagnosing graft infection, since it remains low and stable from the early postoperative period. After open surgical repair, it seems acceptable to have 'stepwise cut-off value' depending on the time from surgery.


Assuntos
Procedimentos Endovasculares , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Aorta/diagnóstico por imagem , Aorta/cirurgia , Procedimentos Endovasculares/efeitos adversos , Compostos Radiofarmacêuticos
12.
Ann Thorac Surg ; 114(5): e385-e387, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35216999

RESUMO

Systolic anterior motion is occasionally encountered during mitral valve repair using neochordal reconstruction for mitral regurgitation owing to large posterior leaflet prolapse. In cases with a redundant posterior leaflet, the risk of systolic anterior motion increases if the redundant posterior leaflet is unresected to decrease the leaflet height. The posterior leaflet was fixed at the anterior annulus, cut near the posterior annulus, and resected into a spindle shape. The excised part of the posterior leaflet was subsequently closed with a continuous suture. Herein, we report our simple height reduction technique of the posterior leaflet, the "curtain technique," performed in robotic surgery.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Procedimentos Cirúrgicos Robóticos , Humanos , Anuloplastia da Valva Mitral/métodos , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 60(2): 420-422, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-33550420

RESUMO

To prevent embolic stroke during thoracic endovascular aortic repair, we have adopted the brain isolation technique since June 2014 in 9 selected high-risk patients (9/134: 6.7%) having ulcerated or protruding atheromas within the proximal aorta. Cardiopulmonary bypass was used to prevent aortic atheromas from entering the brain. We used a heparin-coated closed-loop cardiopulmonary bypass system incorporating a soft reservoir bag with 1 mg/kg heparin to minimize the disadvantages of extracorporeal circulation. The bypass graft (right axillary-left carotid-left axillary) was used as an arterial inflow in patients undergoing zone-1 landing (n = 8), while peripheral cannulation into 3 brachiocephalic arteries was employed in the remaining patient. Initial pump flow was set at 1.3 l/min/m2, and native cardiac output was reduced by adjusting the reservoir bag volume. Aortography was performed to confirm non-visualization of the arch vessels before catheter manipulation. There was no mortality and 1 solitary left cerebellar infarction.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Encéfalo , Procedimentos Endovasculares/efeitos adversos , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
14.
JTCVS Tech ; 4: 28-35, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34317958

RESUMO

OBJECTIVE: Although transesophageal motor-evoked potential elicited by monopolar cervical cord stimulation is more stable and rapid in response to ischemia than transcranial motor-evoked potential in canine experiments, direct cervical alpha motor neuron stimulation precludes clinical application. We evaluated a novel stimulation method using a bipolar esophageal electrode to enable thoracic cord stimulation. METHODS: Twenty dogs were anesthetized. For bipolar transesophageal stimulation, the interelectric pole distance was set at 4 cm. Changes in amplitude in response to incremental stimulation intensity (100-600 V) were measured to evaluate stability. Spinal cord ischemia was induced by aortic balloon occlusion at the T8 to T10 level for 10 minutes to evaluate response time or at the T3 to T5 level for 25 minutes to evaluate prognostic value. Neurological function was evaluated using the Tarlov score at 24 and 48 hours postoperatively. RESULTS: Bipolar transesophageal stimulation was successful in all animals and their forelimb waveforms were identical to those after transcranial stimulation. The minimum stimulation intensity to produce >90% of the maximum amplitude was significantly lower in both monopolar and bipolar transesophageal stimulation than in transcranial stimulation (n = 5). Time to disappearance and recovery (>75%) of the hindlimb potentials were significantly shorter by both monopolar and bipolar transesophageal stimulation than by transcranial stimulation (n = 5). Correlation with neurological outcomes was comparable among all stimulation methods (n = 10). CONCLUSIONS: Motor-evoked potential can be elicited by bipolar transesophageal thoracic cord stimulation without direct cervical alpha motor neuron stimulation, and its stability and response time are comparable to those elicited by monopolar stimulation.

15.
Eur J Cardiothorac Surg ; 57(6): 1076-1082, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32011686

RESUMO

OBJECTIVES: Canine experiments have shown that transoesophageal motor-evoked potential monitoring is feasible, safe and stable, with a quicker response to ischaemia and a better prognostic value than transcranial motor-evoked potentials. We aimed to elucidate whether or not these findings were clinically reproducible. METHODS: A bipolar oesophageal electrode mounted on a large-diameter silicon tube and a train of 5 biphasic wave stimuli were used for transoesophageal stimulation. Results of 18 patients (median age 74.5 years, 13 males) were analysed. RESULTS: There were no mortalities, spinal cord injuries or complications related with transoesophageal stimulation. Transcranial motor-evoked potential could not be monitored up to the end of surgery in 3 patients for unknown reasons, 2 of whom from the beginning. Transoesophageal motor-evoked potential became non-evocable after manipulation of a transoesophageal echo probe in 2 patients. Strenuous movement of the upper limbs during transoesophageal stimulation was observed in 3 patients. In 14 patients who successfully completed both monitoring methods up to the end of surgery (11 thoraco-abdominal and 3 descending aortic repair), the final results were judged as false positives in 6 by transcranial stimulation and in 1 by transoesophageal stimulation. The stimulation intensity was significantly lower and the upper limb amplitude was significantly higher by transoesophageal stimulation, while the lower limb amplitude was comparable. CONCLUSIONS: Transoesophageal motor-evoked potential monitoring is clinically feasible and safe with a low false positive rate. A better electrode design is required to avoid its migration by transoesophageal echo manipulation. Further studies may be warranted. CLINICAL REGISTRATION NUMBER: UMIN000022320.


Assuntos
Monitorização Intraoperatória , Traumatismos da Medula Espinal , Idoso , Animais , Cães , Esôfago , Potencial Evocado Motor , Estudos de Viabilidade , Humanos , Masculino
16.
Eur J Cardiothorac Surg ; 56(4): 778-784, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30859210

RESUMO

OBJECTIVES: Aortic valve-sparing operations have been shown to produce fewer valve-related complications than valve replacement. The aortic root is a morphological and functional unit in which the annulus plays an important role on dynamism, shape and geometry of the valve with different results in bicuspid aortic valves (BAVs) or tricuspid aortic valves (TAVs). The aim is to evaluate the differences in the size and shape of the aortic annulus between native BAVs and TAVs using ECG-gated computed tomography (CT) after a reimplantation procedure. METHODS: We selected 35 patients scheduled for aortic valve reimplantation who underwent good-quality preoperative and postoperative ECG-gated contrast-enhanced CT scan of the aortic root. Twenty-three patients had TAV, 8 patients type 1 BAV and 4 patients type 0 BAV. Major diameter and minor diameter, perimeter (P) and area (A) were measured. The shape of the aortic annulus was considered 'circular' or 'elliptic' according to the Ellipticity Index. We also selected a subgroup of 18 patients (9 TAVs and 9 BAVs) to evaluate annular shape and size variations through the cardiac cycle and to study the expansibility both in the preoperative and in the postoperative phases. RESULTS: Preoperative CT scans showed an elliptic shape of TAVs (Ellipticity Index 1.3 ± 0.1), a circular shape of type 0 BAVs (1.1 ± 0.1) and an intermediate behaviour of type 1 BAVs, suggesting a possible gradual spectrum of circularity from TAVs to type 1 BAVs to type 0 BAVs. Postoperative CT scans did not show any significant difference in annular shape among the 3 groups, which demonstated a similar roundness, obviating the preoperative differences. Analysing the expansibility of the aortic annulus during the cardiac cycle, we observed that it was completely absent in the preoperative phase in BAVs, while in the postoperative phase, both TAVs and BAVs showed a small but similar expansibility after the annular reduction. CONCLUSIONS: There is a possible gradual spectrum in terms of shape, from native TAVs, to type 1 BAVS to type 0 BAVs. These differences are eliminated in the postoperative phase, suggesting an active role of the annuloplasty on the geometry of the aortic annulus. The preoperative analysis showed a complete inelasticity of BAVs, which was partly restored in the postoperative phase.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Eletrocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca , Tomografia Computadorizada por Raios X , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/diagnóstico por imagem , Adulto , Idoso , Valva Aórtica/anatomia & histologia , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reoperação , Adulto Jovem
17.
Gen Thorac Cardiovasc Surg ; 67(1): 187-191, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28932974

RESUMO

OBJECTIVE: Operative mortality and morbidity after thoracoabdominal aortic surgery remain high. We report our strategy and outcomes, especially those of spinal cord protection. METHODS: Outcomes of 178 patients (age: 26-88 years) who underwent thoracoabdominal aortic replacement were retrospectively analyzed. 65 had aortic dissection, 14 had infected aneurysms, and 22 presented with rupture. Operations were non-elective in 24 and redo through re-thoracotomy in 21. Extent of replacement was Crawford-I in 39, II in 26, III in 78, and IV in 35. Staged repair was recently preferred, which resulted in decrease in extent II repair and increase in redo since 2009. Operations were performed under distal aortic perfusion and multi-segmental sequential repair to maximize collateral blood flow, and deep hypothermic circulatory arrest was preserved for those requiring open aortic anastomosis (n = 20). A total of 166 separate grafts were used for intercostal reconstruction in 88 patients, which was guided by preoperative feeding artery localization. Their patency was studied by postoperative MD-CT in 74 patients for 145 grafts. RESULTS: There were 3.9% hospital mortality and 5.1% spinal cord injury. Preoperative feeding artery localization resulted in reduced number of reconstruction and improved patency, and grafts connecting to the feeding artery were patent in 92%. Results of redo operations were not different (no mortality and spinal cord injury) from the de novo operations. CONCLUSIONS: Our concept of spinal cord protection, which was based on selective intercostal reconstruction while maximizing spinal cord collateral blood flow, seems justified.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Parada Circulatória Induzida por Hipotermia Profunda , Traumatismos da Medula Espinal/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica , Dissecção Aórtica/cirurgia , Circulação Colateral , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
19.
Interact Cardiovasc Thorac Surg ; 27(1): 75-80, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29529205

RESUMO

OBJECTIVES: To prevent haemodynamic stroke during cardiovascular surgery in patients with carotid stenosis, we routinely evaluated magnetic resonance angiography and selectively evaluated brain perfusion single-photon emission computed tomography with acetazolamide challenge. Off-pump surgery was preferred when cerebral blood flow reserve was impaired. This strategy's usefulness was investigated. METHODS: Among the 1059 consecutive patients who underwent preoperative carotid screening by magnetic resonance angiography, 84 (7.9%) patients had >50% stenosis; 45 of them underwent brain single-photon emission computed tomography. The severity of cerebral blood flow compromise was estimated by the proportion of Stage 2 area in the affected territory, in which both resting blood flow (<32 ml/min) and flow reserve (<10%) were reduced. RESULTS: Perioperative stroke occurred in 1.7% overall (18/1059), in 6% (5/84) of those with carotid stenosis and in 1.3% (13/975) of those without stenosis (P = 0.010). On subgroup analysis, carotid stenosis was associated with an increased risk of stroke in the on-pump surgery group [n = 949, 5/59 (9%) with stenosis vs 11/890 (1.1%) without stenosis, P = 0.002], while it was not in the off-pump group [n = 110, 0/25 (0%) with stenosis vs 2/85 (2%) without stenosis, P = 0.59]. With respect to the role of acetazolamide single-photon emission computed tomography, 2 of the 4 patients with Stage 2 area >10% undergoing on-pump surgery without preceding carotid revascularization developed stroke, while none of the 21 patients with Stage 2 area <10% undergoing on-pump surgery developed stroke (P = 0.020). CONCLUSIONS: Carotid stenosis is a risk factor for perioperative stroke in on-pump surgery. Patients with large Stage 2 area (>10%) are at increased risk of perioperative stroke when on-pump surgery is performed.


Assuntos
Estenose das Carótidas/complicações , Estenose das Carótidas/fisiopatologia , Circulação Cerebrovascular/fisiologia , Complicações Pós-Operatórias/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Acetazolamida , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa