Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Sep Sci ; 47(19): e202400277, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39385440

RESUMO

Nitrosamine-related impurities (N-nitrosomethylamino butyric acid [NMBA], N-nitrosodiethylamine [NDEA], N-nitrosodiisopropylamine [NDIPA], N-nitrosomethylphenylamine [NMPA], N-nitrosodibutylamine [NDBA], N-nitrosodimethylamine [NDMA], and N-nitrosoethylisopropylamine [NEIPA]) and 5-[4'-(azidomethyl)-[1,1'-biphenyl]-2-yl]-2H-tetrazole (AZBT) formed during the manufacture of sartan medicines have been classified into human mutagens and carcinogens after long-term treatment. The study developed a simple, economical but highly sensitive procedure for the simultaneous quantification of seven nitrosamines and AZBT impurities in sartan pharmaceuticals. After extraction with methanol (MeOH) 50%, the compounds were analyzed with a reversed-phase liquid chromatography-tandem mass spectroscopy with atmospheric-pressure chemical ionization (APCI) mode (APCI[+] for nitrosamines and APCI[-] for AZBT), selected reaction monitoring, C18 column, gradient elution with 0.1% formic acid in water and in MeOH, respectively. The validated procedure obtained high extraction efficiency (>90%), wide linear range (0.2-50.0 ng/mL NMBA, NDEA, NDIPA, NMPA, and NDBA; 0.5-50.0 ng/mL NDMA and NEIPA; 2.0-100 ng/mL AZBT), limit of quantification < 10% of the acceptance level, recovery range of 85%-115% with relative standard deviation < 15% and minimum matrix effects for all impurities. The procedure was applied to test 16 commercial losartan samples. As a result, eight samples contained AZBT within the current regulatory limits, but no nitrosamine impurities were detected in all samples.


Assuntos
Contaminação de Medicamentos , Losartan , Nitrosaminas , Espectrometria de Massas em Tandem , Tetrazóis , Nitrosaminas/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Losartan/análise , Tetrazóis/análise
2.
Food Sci Anim Resour ; 43(4): 563-579, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37484005

RESUMO

Myogenesis and adipogenesis are the important processes determining the muscle growth and fat accumulation livestock, which ultimately affecting their meat quality. Hanwoo is a popular breed and its meat has been exported to other countries. The objective of this study was to compare the myogenesis and adipogenesis properties in satellite cells, and meat quality between Hanwoo and Vietnamese yellow cattle (VYC). Same 28-months old Hanwoo (body weight: 728±45 kg) and VYC (body weight: 285±36 kg) steers (n=10 per breed) were used. Immediately after slaughter, tissue samples were collected from longissimus lumborum (LL) muscles for satellite cells isolation and assays. After 24 h post-mortem, LL muscles from left carcass sides were collected for meat quality analysis. Under the same in vitro culture condition, the proliferation rate was higher in Hanwoo compared to VYC (p<0.05). Fusion index was almost 3 times greater in Hanwoo (42.17%), compared with VYC (14.93%; p<0.05). The expressions of myogenesis (myogenic factor 5, myogenic differentiation 1, myogenin, and myogenic factor 6)- and adipogenesis (peroxisome proliferator-activated receptor gamma)-regulating genes, and triglyceride content were higher in Hanwoo, compared with VYC (p<0.05). Hanwoo beef had a higher intramuscular fat and total monounsaturated fatty acids contents than VYC beef (p<0.05). Whilst, VYC meat had a higher CIE a* and total polyunsaturated fatty acids content (p<0.05). Overall, there was a significant difference in the in vitro culture characteristics and genes expression of satellite cells, and meat quality between the Hanwoo and VYC.

3.
Pharmaceutics ; 13(11)2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34834212

RESUMO

The development of new drugs that combine active ingredients for the treatment hypertension is critically essential owing to its offering advantages for both patients and manufacturers. In this study, for the first time, detailed development of a scalable process of film-coated bi-layer tablets containing sustained-release metoprolol succinate and immediate-release amlodipine besylate in a batch size of 10,000 tablets is reported. The processing parameters of the manufacturing process during dry mixing-, drying-, dry mixing- completion stages were systematically investigated, and the evaluation of the film-coated bi-layer tablet properties was well established. The optimal preparation conditions for metoprolol succinate layer were 6 min- dry mixing with a high-speed mixer (120 rpm and 1400 rpm), 30-min drying with a fluid bed dryer, and 5-min- mixing completion at 25 rpm. For the preparation of amlodipine besylate layer, the optimal dry-mixing time using a cube mixer (25 rpm) was found to be 5 min. The average weight of metoprolol succinate layers and bi-layer tablets were controlled at 240-260 mg and 384-416 mg, respectively. Shewhart R chart and X¯ charts of all three sampling lots were satisfactory, confirming that the present scalable process was stable and successful. This study confirms that the manufacturing process is reproducible, robust; and it yields a consistent product that meets specifications.

4.
Biomed Res Int ; 2021: 5516344, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34368349

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a pandemic of pneumonia spreading around the world, leading to serious threats to public health and attracting enormous attention. There is an urgent need for sensitive diagnostic testing implementation to control and manage SARS-CoV-2 in public health laboratories. The quantitative reverse transcription PCR (RT-qPCR) assay is the gold standard method, but the sensitivity and specificity of SARS-CoV-2 testing are dependent on a number of factors. METHODS: We synthesized RNA based on the genes published to estimate the concentration of inactivated virus samples in a biosafety level 3 laboratory. The limit of detection (LOD), linearity, accuracy, and precision were evaluated according to the bioanalytical method validation guidelines. RESULTS: We found that the LOD reached around 3 copies/reaction. Furthermore, intra-assay precision, accuracy, and linearity met the accepted criterion with an RSD for copies of less than 25%, and linear regression met the accepted R 2 of 0.98. CONCLUSIONS: We suggest that synthesized RNA based on the database of the NCBI gene bank for estimating the concentration of inactivated virus samples provides a potential opportunity for reliable testing to diagnose coronavirus disease 2019 (COVID-19) as well as limit the spread of the disease. This method may be relatively quick and inexpensive, and it may be useful for developing countries during the pandemic era. In the long term, it is also applicable for evaluation, verification, validation, and external quality assessment.


Assuntos
COVID-19/virologia , Técnicas de Diagnóstico Molecular/normas , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/genética , Países em Desenvolvimento/estatística & dados numéricos , Humanos , Técnicas de Diagnóstico Molecular/métodos , Pandemias , RNA Viral/análise , SARS-CoV-2/isolamento & purificação , Estudos de Validação como Assunto
5.
J Chromatogr A ; 982(1): 153-61, 2002 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-12489864

RESUMO

In the present investigation, a co-electroosmotic capillary zone electrophoretic method is shown for the simultaneous separation of protease inhibitors and reverse transcriptase inhibitors, which are used as antiretroviral therapy drags against the human immunodeficiency virus (HIV). The investigated drugs carry basic amino groups, thus the electrophoretic system takes advantage of an acidic buffer electrolyte. In order to establish a strong cathodic electroosmotic flow (EOF), a poly-anionic surfactant is added to the background electrolyte. Thus, fast migration times due to a co-directional migration of analytes and EOF (co-electroosmotic CE) are obtained. The developed separation system exhibits good selectivities for the investigated compounds and sufficient sensitivity to monitor drug levels in the low ppm range in HIV positive patients who are treated by highly active anitiretroviral therapy.


Assuntos
Eletroforese Capilar/métodos , Infecções por HIV/tratamento farmacológico , Inibidores da Protease de HIV/isolamento & purificação , Inibidores da Transcriptase Reversa/isolamento & purificação , Inibidores da Protease de HIV/uso terapêutico , Inibidores da Transcriptase Reversa/uso terapêutico
6.
Electrophoresis ; 24(4): 662-70, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12601735

RESUMO

In the present investigation, a novel approach towards a complete separation of all 15 protease and reverse transcriptase inhibitors which are currently approved for use in highly active antiretroviral therapy in a single analytical run is presented. The developed method employs an acidic background electrolyte with sodium polyanethol sulfonate (SPAS) as polyanionic electroosmotic flow (EOF) modifier to establish a strong cathodic EOF, sodium dodecyl sulfate (SDS) as pseudostationary selector, and acetonitrile and ethanol as organic modifiers. Separation of the analytes is based on two different mechanisms. The more basic analytes are protonated at the prevailing pH conditions and thus migrate in front of the cathodic EOF, whereas the less basic and neutral analytes interact with the SDS and are retained after the EOF. By optimizing electrolyte pH, the amount of solvents and SDS concentrations in the background electrolyte it is possible to completely separate all compounds of interest.


Assuntos
Eletroforese Capilar/métodos , Inibidores da Protease de HIV/isolamento & purificação , Inibidores da Transcriptase Reversa/isolamento & purificação , Infecções por HIV/tratamento farmacológico , Inibidores da Protease de HIV/sangue , Humanos , Inibidores da Transcriptase Reversa/sangue
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa