Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Nanotechnology ; 30(45): 455701, 2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-31362268

RESUMO

Arrays of manganese dioxide (MnO2), a pseudocapacitive material, have been deposited on the carbon fibers (CF) of a carbon woven fabric by electrodeposition from a solution containing manganese sulfate and sulfuric acid using galvanostatic square waves. The thickness of the MnO2 was varied by increasing/decreasing the time of deposition, and the electrochemical performance of the MnO2 has been analyzed. The CF serves as a substrate material with high surface area, good electrical conductivity and excellent mechanical strength. The electrochemical properties of the resultant electrode were examined by cyclic voltammogram (CV), galvanostatic charge/discharge, and electrochemical impedance spectroscopy in a three-electrode system. From the specific capacitance calculations obtained from CV and charge-discharge, a high specific capacitance of 769 F g-1 @ 5 mV s-1 (low weight electrode) has been achieved. The maximum area capacitance, estimated from the charge-discharge curves, was 790 mF cm-2 @ 5 mV s-1. The high-performance is attributed to the double layer capacitance of the CFs combined with the pseudocapacitive nature of MnO2, the large surface area, and high degree of ordering of the ultrathin MnO2.

2.
J Biochem Mol Toxicol ; 26(2): 45-53, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21308894

RESUMO

Microglia have been implicated in the pathogenesis of several neurodegenerative diseases, but their precise role remains elusive. Although neuron loss in the presence of lipopolysaccharide-stimulated microglia has been well documented, a novel coculture paradigm was developed as a new approach to assess the diffusible, soluble mediators of neurodegeneration. Isolated microglia were plated on membrane inserts that were coated with a layer of cellulose acetate. The cellulose acetate-coated membranes have nanofiltration properties, in that only molecules with masses less than 350 Da can pass through. Products released from activated microglia that were separated from primary ventral mesencephalon cells beneath the nanofiltering membrane were able to kill the dopamine neurons. Microglial cytokines cannot diffuse through this separating membrane. Addition of a nitric oxide synthase inhibitor prevented the loss of the dopamine neurons. These data describe a novel coculture system for studying diffusible factors and further support nitric oxide production as an important mediator in microglia-induced neuron death.


Assuntos
Neurônios Dopaminérgicos/fisiologia , Microglia/metabolismo , Animais , Sobrevivência Celular , Células Cultivadas , Celulose/análogos & derivados , Celulose/ultraestrutura , Técnicas de Cocultura/métodos , Neurônios Dopaminérgicos/enzimologia , Neurônios Dopaminérgicos/patologia , Lipopolissacarídeos/farmacologia , Membranas Artificiais , Mesencéfalo/citologia , Microglia/enzimologia , Microglia/imunologia , NG-Nitroarginina Metil Éster/farmacologia , Doenças Neurodegenerativas/patologia , Óxido Nítrico/metabolismo , Óxido Nítrico/fisiologia , Óxido Nítrico Sintase/antagonistas & inibidores , Óxido Nítrico Sintase/metabolismo , Ratos , Ratos Sprague-Dawley , Tirosina 3-Mono-Oxigenase/metabolismo
3.
J Clin Med ; 9(6)2020 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-32512725

RESUMO

One thousand and eighty patients, having prolonged bleeding times, frequent epistaxis, menorrhagia or easy bruising or other bleeding manifestations, and excluding those with von Willebrand's disease, were evaluated for platelet dense granule deficiency. The mean diameter of platelet dense granules was determined for all patients using image analysis. Four hundred and ninety-nine had "classic" dense (delta) granule storage pool deficiency (δ-SPD). Five hundred and eighty-one individuals (53.8%) were found to have a normal mean number of dense granules, but for some of these patients, the dense granules were smaller than for the controls. Of the patients having a normal number of dense granules, 165 (28.4%) were found to have significantly smaller granules than the platelets obtained from the control subjects. Their average granule diameter was 123.35 ± 0.86 nm, that is more than three standard deviations below the mean of the control data. Total δ-granule storage pool volumes (TDGV)/platelet were calculated using these measurements. Individuals with δ-SPD had half the number of granules (2.25 ± 0.04 DG/PL) and storage pool volume (3.88 ± 1.06 × 106 nm3) when compared to our control data (4.64 ± 0.11 DG/PL; 10.79 × 106 nm3 ± 0.42). Individuals having a bleeding history but a normal average of small dense granules had a calculated storage pool volume statistically different than controls and essentially the same storage pool volume as patients with δ-SPD. We have identified a sub-classification of δ-SPD that we have defined as micro-granular storage pool deficiency (δ-MGSPD).

4.
Biomacromolecules ; 10(1): 174-83, 2009 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-19061335

RESUMO

Local pharmacological intervention may be needed to ensure the long-term performance of neural prosthetic devices because of insertion-related neuron loss and reactive cell responses that form compact sheaths, leading to decreased device performance. We propose that local delivery of neurotrophins would enhance neuron survival and promote neuron sprouting toward device electrodes, thus providing improved electrode-neuron communication and device performance for recording and stimulating CNS activity. In this study, three different types of poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogels were developed and assessed for storage capacity and release rates of the neurotrophin, nerve growth factor (NGF). Additionally, a method was developed for routine coating of microfabricated neuroprosthetic devices with the different pHEMA hydrogels. Biological responses to hydrogel-delivered NGF from the devices were measured using primary cell cultures of dorsal root ganglion (DRG) neurons. Neuron process growth was used to assess biological responses to released NGF. When targeted media concentrations were the same, responses to bath-applied NGF and NGF released from pHEMA hydrogels were not significantly different. When NGF was released from lysine-conjugated pHEMA hydrogels, a significant increase in process growth was observed. Our studies demonstrate that pHEMA coatings can be used on neural devices consistent with the needs for local neurotrophin delivery in the brain.


Assuntos
Materiais Revestidos Biocompatíveis/química , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Metacrilatos/química , Fator de Crescimento Neural/química , Fator de Crescimento Neural/farmacologia , Neurônios/citologia , Neurônios/efeitos dos fármacos , Animais , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Estrutura Molecular , Tamanho da Partícula , Ratos , Ratos Sprague-Dawley , Propriedades de Superfície , Fatores de Tempo
5.
Cytometry A ; 73(1): 36-43, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18067123

RESUMO

Automated tracing of neuronal processes from 3D confocal microscopy images is essential for quantitative neuroanatomy and neuronal assays. Two basic approaches are described in the literature-one based on skeletonization and another based on sequential tracing along neuronal processes. This article presents algorithms for improving the rate of detection, and the accuracy of estimating the location and process angles at branching points for the latter class of algorithms. The problem of simultaneously detecting branch points and estimating their measurements is formulated as a generalized likelihood ratio test defined on a spatial neighborhood of each candidate point, in which likelihoods were computed using a ridge detection approach. The average detection rate increased from from 37 to 86%. The average error in locating the branch points decreased from 2.6 to 2.1 voxels in 3D images. The generalized hypothesis test improves the rate of detection of branching points, and the accuracy of location estimates, enabling a more complete extraction of neuroanatomy and more accurate counting of branch points in neuronal assays. More accurate branch point morphometry is valuable for image registration and change analysis.


Assuntos
Encéfalo/patologia , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Nêutrons , Algoritmos , Animais , Automação , Processamento de Imagem Assistida por Computador , Funções Verossimilhança , Modelos Neurológicos , Modelos Estatísticos , Neurônios/metabolismo , Ratos , Ratos Wistar , Reprodutibilidade dos Testes
6.
J Neurosci Methods ; 162(1-2): 255-63, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17368788

RESUMO

Biochemical surface modification has been used to direct cell attachment and growth on a biocompatible gel surface. Acrylamide-based hydrogels were photo-polymerized in the presence of an acroyl-streptavidin monomer to create planar, functionalized surfaces capable of binding biotin-labelled proteins. Soft protein lithography (microcontact printing) of proteins was used to transfer the biotinylated extracellular matrix proteins, fibronectin and laminin, and the laminin peptide biotin-IKVAV, onto modified surfaces. As a biological assay, we plated LRM55 astroglioma and primary rat hippocampal neurons on patterned hydrogels. We found both cell types to selectively adhere to areas patterned with biotin-conjugated proteins. Fluorescence and bright-field modes of microscopy were used to assess cell attachment and cell morphology on modified surfaces. LRM55 cells were found to attach to protein-stamped regions of the hydrogel only. Neurons exhibited significant neurite extension after 72h in vitro, and remained viable on protein-stamped areas for more than 4 weeks. Patterned neurons developed functionally active synapses, as measured by uptake of the dye FM1-43FX. Results from this study suggest that hydrogel surfaces can be patterned with multiple proteins to direct cell growth and attachment.


Assuntos
Divisão Celular/fisiologia , Neurônios/citologia , Proteínas/fisiologia , Animais , Materiais Biocompatíveis , Biotinilação , Técnicas de Cultura de Células/métodos , Fibronectinas , Hidrogéis , Cinética , Laminina , Neurônios/fisiologia , Compostos de Piridínio/metabolismo , Compostos de Amônio Quaternário/metabolismo , Ratos , Propriedades de Superfície
7.
J Neurosci Methods ; 160(2): 317-26, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17049614

RESUMO

Synaptic activity recorded from low-density networks of cultured rat hippocampal neurons was monitored using microelectrode arrays (MEAs). Neuronal networks were patterned with poly-l-lysine (PLL) using microcontact printing (microCP). Polydimethysiloxane (PDMS) stamps were fabricated with relief structures resulting in patterns of 2 microm-wide lines for directing process growth and 20 microm-diameter circles for cell soma attachment. These circles were aligned to electrode sites. Different densities of neurons were plated in order to assess the minimal neuron density required for development of an active network. Spontaneous activity was observed at 10-14 days in networks using neuron densities as low as 200 cells/mm(2). Immunocytochemistry demonstrated the distribution of dendrites along the lines and the location of foci of the presynaptic protein, synaptophysin, on neuron somas and dendrites. Scanning electron microscopy demonstrated that single fluorescent tracks contained multiple processes. Evoked responses of selected portions of the networks were produced by stimulation of specific electrode sites. In addition, the neuronal excitability of the network was increased by the bath application of high K(+) (10-12 mM). Application of DNQX, an AMPA antagonist, blocked all spontaneous activity, suggesting that the activity is excitatory and mediated through glutamate receptors.


Assuntos
Meios de Cultura/química , Eletrofisiologia/métodos , Hipocampo/fisiologia , Rede Nervosa/fisiologia , Neurofisiologia/métodos , Polilisina/química , Potenciais de Ação/efeitos dos fármacos , Potenciais de Ação/fisiologia , Animais , Adesão Celular/fisiologia , Contagem de Células , Técnicas de Cultura de Células/métodos , Células Cultivadas , Dendritos/efeitos dos fármacos , Dendritos/metabolismo , Dendritos/ultraestrutura , Dimetilpolisiloxanos/química , Eletrofisiologia/instrumentação , Antagonistas de Aminoácidos Excitatórios/farmacologia , Hipocampo/ultraestrutura , Microeletrodos , Microscopia Eletrônica de Varredura , Rede Nervosa/ultraestrutura , Neurofisiologia/instrumentação , Nylons/química , Potássio/metabolismo , Potássio/farmacologia , Ratos , Ratos Sprague-Dawley , Receptores de Glutamato/efeitos dos fármacos , Receptores de Glutamato/metabolismo , Transmissão Sináptica/efeitos dos fármacos , Transmissão Sináptica/fisiologia , Sinaptofisina/metabolismo
8.
J Chromatogr A ; 1162(2): 187-92, 2007 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-17628577

RESUMO

Isolation of fetal cells from maternal circulation is the subject of intense research to eliminate the need for currently used invasive prenatal diagnosis procedures. Fetal cells can be isolated using magnetic-activated cell sorting or fluorescence-activated cell sorting, however no technique to specifically isolate and use fetal cells for genetic diagnosis has reached routine clinical practice. This paper demonstrates the use of a micromachined device to separate fetal cells from maternal circulation based on differences in size and deformation characteristics. Nucleated fetal red blood cells range in diameter from 9 to 12 microm can deform and pass through a channel as small as 2.5 microm wide and 5 microm deep. Although the white blood cells range in diameter from 10 to 20 microm, they cannot deform and are retained by the 2.5 microm wide and 5 microm deep channels under our experimental conditions. Fetal cells were isolated from cord blood and DNA analysis confirmed their fetal origin with ruled out maternal contamination.


Assuntos
Separação Celular/instrumentação , Separação Celular/métodos , Desenho Assistido por Computador , Sangue Fetal/citologia , Animais , Forma Celular , Tamanho Celular , DNA/análise , DNA/genética , Eritroblastos/citologia , Eritroblastos/metabolismo , Eritrócitos Anormais/citologia , Eritrócitos Anormais/metabolismo , Feminino , Sangue Fetal/metabolismo , Doenças Fetais/sangue , Doenças Fetais/diagnóstico , Gansos , Humanos , Reação em Cadeia da Polimerase , Gravidez , Diagnóstico Pré-Natal/instrumentação , Diagnóstico Pré-Natal/métodos , Reprodutibilidade dos Testes
9.
J Biomed Mater Res A ; 81(2): 347-54, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17120223

RESUMO

Patterning of multiple proteins and enzymes onto biocompatible surfaces can provide multiple signals to control cell attachment and growth. Acrylamide-based hydrogels were photo-polymerized in the presence of streptavidin-acrylamide, resulting in planar gel surfaces functionalized with the streptavidin protein. This surface was capable of binding biotin-labeled biomolecules. The proteins fibronectin and laminin, the enzyme alkaline phosphatase, and the photo-protein R-phycoerythrin were patterned using soft lithographic techniques. Polydimethylsiloxane stamps were used to transfer biotinylated proteins onto streptavidin-conjugated hydrogel surfaces. Stamped biomolecules were spatially resolved to feature sizes of 10 mum. Fluorescence measurements were used to assess protein transfer and enzyme functionality on modified surfaces. Our results demonstrate that hydrogel surfaces can be patterned with multiple proteins and enzymes, with retention of biological and catalytic activity. These surfaces are biocompatible and provide cues for cell attachment and growth. (c) 2006 Wiley Periodicals, Inc. J Biomed Mater Res 2007.


Assuntos
Materiais Biocompatíveis/química , Proteínas/química , Animais , Biotina/química , Linhagem Celular , Enzimas/química , Humanos , Hidrogéis , Teste de Materiais , Ligação Proteica , Estreptavidina/química , Propriedades de Superfície
10.
Med Biol Eng Comput ; 45(11): 1015-21, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17684784

RESUMO

Planar microelectrode arrays (MEAs) are widely used to record electrical activity from neural networks. However, only a small number of functional recording sites frequently show electrical activity. One contributing factor may be that neurons in vitro receive insufficient synaptic input to develop into fully functional networks. In this study, electrical stimulation was applied to neurons mimicking synaptic input. Various stimulation paradigms were examined. Stimulation amplitude and frequency were tailored to prevent cell death. Two effects of stimulation were observed when 3-week-old cultures were stimulated: (1) clusters of neural cells were observed adjacent to stimulating electrodes and (2) an increase in spontaneous neuronal activity was recorded at stimulating electrodes. Immunocytochemical analysis indicates that stimulation may cause both new neuron process growth as well as astrocyte activation. These data indicate that electrical stimulation can be used as a tool to modify neural networks at specific electrode sites and promote electrical activity.


Assuntos
Estimulação Elétrica/métodos , Rede Nervosa/citologia , Animais , Agregação Celular , Células Cultivadas , Hipocampo/citologia , Microeletrodos , Ratos , Ratos Sprague-Dawley
11.
J Med Imaging (Bellingham) ; 4(1): 011003, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27921074

RESUMO

Using analytical and Monte Carlo modeling, we explored performance of a lightweight wearable helmet-shaped brain positron emission tomography (PET), or BET camera, based on thin-film digital Geiger avalanche photodiode arrays with Lutetium-yttrium oxyorthosilicate (LYSO) or [Formula: see text] scintillators for imaging in vivo human brain function of freely moving and acting subjects. We investigated a spherical cap BET and cylindrical brain PET (CYL) geometries with 250-mm diameter. We also considered a clinical whole-body (WB) LYSO PET/CT scanner. The simulated energy resolutions were 10.8% (LYSO) and 3.3% ([Formula: see text]), and the coincidence window was set at 2 ns. The brain was simulated as a water sphere of uniform F-18 activity with a radius of 100 mm. We found that BET achieved [Formula: see text] better noise equivalent count (NEC) performance relative to the CYL and [Formula: see text] than WB. For 10-mm-thick [Formula: see text] equivalent mass systems, LYSO (7-mm thick) had [Formula: see text] higher NEC than [Formula: see text]. We found that [Formula: see text] scintillator crystals achieved [Formula: see text] full-width-half-maximum spatial resolution without parallax errors. Additionally, our simulations showed that LYSO generally outperformed [Formula: see text] for NEC unless the timing resolution for [Formula: see text] was considerably smaller than that presently used for LYSO, i.e., well below 300 ps.

12.
Biomaterials ; 27(35): 5883-91, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16934867

RESUMO

Hydrogels are useful for linking proteins to solid surfaces because their hydrophilic nature and porous structure help them to maintain these labile molecules in the native functional state. We have developed a method for creating surface-patterned, biofunctionalized hydrogels on glass or silicon, using polyacrylamide and the disulfide-containing polyacrylamide crosslinker, bis(acryloyl)cystamine. Treatment with a reducing agent created reactive sulfhydryl (-SH) groups throughout these hydrogels that were readily conjugated to iodoacetyl biotin and streptavidin (SA). Immobilization efficiency was approximately 1-2% of the total potential binding capacity of the hydrogel. Porosity of the hydrogel was not a limiting factor for SA immobilization, as determined using fluorescence confocal microscopy. Rather, steric hindrance due to the binding of SA decreased the effective porosity near the surface of the hydrogel, restricting access to the rest of the gel. Using microcontact printing, we indirectly patterned SA on the surface of the hydrogel, generating well-resolved feature sizes of 2 microm in width. Through repeated rounds of microcontact printing, multiple, adjacent protein patterns were generated on the surface of the hydrogel. Biotinylated immune complexes and lipid vesicles readily bound to SA-functionalized hydrogels, demonstrating the feasibility of using this hydrogel system to generate complex biofunctionalized surfaces.


Assuntos
Resinas Acrílicas , Hidrogéis , Microscopia Confocal , Microscopia de Fluorescência , Propriedades de Superfície
13.
IEEE Trans Neural Syst Rehabil Eng ; 14(2): 138-41, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16792279

RESUMO

This paper describes the highlights of presentations and discussions during the Third International BCI Meeting in a workshop that evaluated potential brain-computer interface (BCI) signals and currently available recording methods. It defined the main potential user populations and their needs, addressed the relative advantages and disadvantages of noninvasive and implanted (i.e., invasive) methodologies, considered ethical issues, and focused on the challenges involved in translating BCI systems from the laboratory to widespread clinical use. The workshop stressed the critical importance of developing useful applications that establish the practical value of BCI technology.


Assuntos
Algoritmos , Auxiliares de Comunicação para Pessoas com Deficiência/ética , Eletroencefalografia/métodos , Armazenamento e Recuperação da Informação/métodos , Doenças Neuromusculares/reabilitação , Processamento de Sinais Assistido por Computador , Interface Usuário-Computador , Biotecnologia/métodos , Encéfalo/fisiologia , Humanos , Armazenamento e Recuperação da Informação/ética , Internacionalidade , Sistemas Homem-Máquina
14.
J Chromatogr A ; 1111(2): 214-9, 2006 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-16569580

RESUMO

In lab-on-a-chip applications, filtration is currently performed prior to sample loading or through pre-cast membranes adhered to the substrate. These membranes cannot be patterned to micrometer resolution, and their adhesion may be incompatible with the fabrication process or may introduce contaminants. We have developed an on-chip separation process using a biocompatible polymer that can be patterned and has controllable molecular rejection properties. We spun cast cellulose acetate (CA) membranes directly onto silicon wafers. Characterization of the molecular flux across the membrane showed that molecular weight and charge are major factors contributing to the membranes' rejection characteristics. Altering casting conditions such as polymer concentration in the casting solution and the quenching-bath composition and/or temperature allowed control of the molecular weight cut-off (MWCO). Three MWCOs; 300, 350, and 700 Da have been achieved for non-linear molecules. Molecular shape is also very important as much higher molecular weight single-stranded DNA was electrophoresed across the membranes while heme with a similar negative charge density was rejected. This was due to DNA's small molecular cross section. This is an important result because heme inhibits polymerase chain reactions (PCR) reducing the detection and characterization of DNA from blood samples.


Assuntos
Biopolímeros , Membranas Artificiais , Sequência de Bases , Primers do DNA , Microscopia Eletrônica de Varredura , Reação em Cadeia da Polimerase
15.
Biosens Bioelectron ; 21(5): 696-704, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16242607

RESUMO

The current study was undertaken to fabricate a small micro-electrode on-chip to rapidly detect and quantify human CD4(+) cells in a minimal volume of blood through impedance measurements made with simple electronics that could be battery operated implemented in a hand held device. The micro-electrode surface was non-covalently modified sequentially by incubation with solutions of protein G', human albumin, monoclonal mouse anti-human CD4, and mouse IgG. The anti-human CD4 antibody served as the recognition and capture molecule for CD4(+) cells present in human blood. The binding of these biomolecules to the micro-electrodes was verified by impedance and cyclic voltammetry measurements. An increase in impedance was detected for each layer of protein adsorbed onto the micro-electrode surface. This process was shown to be highly repeatable. Increased impedance was measured when CD4(+) cells were captured on the micro-electrode, and the impedance also increased as the number of captured cells increased. Fluorescence microscopy of captured cells immunolabeled with anti-human CD4, CD8, and CD19 antibodies, and the nuclear label DAPI, confirmed that only CD4(+) cells were captured. The results were highly dependent on the specimen preparation method used. We conclude that the on-chip capture system can efficiently quantify the number of CD4(+) cells.


Assuntos
Técnicas Biossensoriais/instrumentação , Contagem de Linfócito CD4/instrumentação , Separação Celular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Microscopia de Fluorescência/instrumentação , Técnicas Biossensoriais/métodos , Contagem de Linfócito CD4/métodos , Separação Celular/métodos , Células Cultivadas , Impedância Elétrica , Eletroquímica/instrumentação , Eletroquímica/métodos , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Técnicas Analíticas Microfluídicas/métodos , Microscopia de Fluorescência/métodos , Óptica e Fotônica/instrumentação
16.
IEEE Trans Neural Syst Rehabil Eng ; 11(2): 186-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12899270

RESUMO

While chronic use of indwelling micromachined neural prosthetic devices has great potential, the development of reactive responses around them results in a decrease in electrode function over time. Since the cellular events responsible for these responses may be anti-inflammatory in nature, we have tested the effectiveness of dexamethasone and cyclosporin A as potential drugs for developing intervention strategies following insertion of single-shank micromachined silicon devices. Peripheral injection of dexamethasone was effective in attenuating increased expression of glial fibrillary acidic protein and astrocyte hyperplasia observed during both initial- and sustained-reactive responses observed at one and six weeks post insertion, respectively. Peripheral injection of cyclosporin A had no positive effect. If anything, application of this drug increased the early reactive response. Effectiveness of local release of dexamethasone in rat neocortex was tested by inserting ribbons of poly (ethyl-vinyl) acetate containing 35% (w/w) dexamethasone. Initial concentrations of dexamethasone were similar to those obtained by peripheral injection. Local drug release provided continued control of cellular reactive responses during the six-week study period. These results demonstrate that peripheral delivery of dexamethasone can be used to control reactive responses and that local drug delivery by slow-release from biocompatible polymers may be a more effective method of drug intervention. Incorporating these strategies on micromachined devices may provide an intervention strategy that will insure the chronic functioning of electrodes on intracortical neuroprosthetic devices.


Assuntos
Materiais Revestidos Biocompatíveis/uso terapêutico , Ciclosporina/administração & dosagem , Dexametasona/administração & dosagem , Eletrodos/efeitos adversos , Próteses e Implantes/efeitos adversos , Infecções Relacionadas à Prótese/tratamento farmacológico , Animais , Preparações de Ação Retardada/administração & dosagem , Injeções Subcutâneas , Masculino , Doenças do Sistema Nervoso/reabilitação , Infecções Relacionadas à Prótese/prevenção & controle , Ratos
17.
IEEE Trans Nanobioscience ; 3(4): 251-6, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15631136

RESUMO

Isolating rare cells from biological fluids including whole blood or bone marrow is an interesting biological problem. Characterization of a few metastatic cells from cancer patients for further study is desirable for prognosis/diagnosis. Traditional methods have not proven adequate, due to the compositional complexity of blood, with its large numbers of cell types. To separate individual cells based on their mechanical characteristics, we have developed a series of massively parallel microfabricated sieving device. These devices were constructed with four successively narrower regions of channels numbering approximately 1800 per region. As cells traversed the device, they encountered each region and stopped at a gap width that prohibited passage due to their size. Cultured neuroblastoma cells, when mixed with whole blood and applied to the device, were retained in the 10-microm-wide by 20-microm-deep channels. All other cells migrated to the output. A derivative of the same device was utilized to characterize migration of whole blood. Adult white blood cells were retained at the 2.5-microm-wide by 5-microm-deep channels, while red blood cells passed through these channels. Devices designed to capture rare cells in peripheral circulation for downstream analysis will provide an important tool for diagnosis and treatment.


Assuntos
Separação Celular/instrumentação , Eritrócitos/citologia , Leucócitos/citologia , Técnicas Analíticas Microfluídicas/instrumentação , Nanotecnologia/instrumentação , Neuroblastoma/patologia , Ultrafiltração/instrumentação , Separação Celular/métodos , Citaferese/instrumentação , Citaferese/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas Analíticas Microfluídicas/métodos , Nanotecnologia/métodos , Neuroblastoma/sangue , Ultrafiltração/métodos
18.
IEEE Trans Biomed Eng ; 51(11): 2063-73, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15536908

RESUMO

Model silicon intracortical probes with microfluidic channels were fabricated and tested to examine the feasibility of using diffusion-mediated delivery to deliver therapeutic agents into the volume of tissue exhibiting reactive responses to implanted devices. Three-dimensional probe structures with microfluidic channels were fabricated using surface micromachining and deep reactive ion etching (DRIE) techniques. In vitro functional tests of devices were performed using fluorescence microscopy to record the transient release of Texas Red labeled transferrin (TR-transferrin) and dextran (TR-dextran) from the microchannels into 1% w/v agarose gel. In vivo performance was characterized by inserting devices loaded with TR-transferrin into the premotor cortex of adult male rats. Brain sections were imaged using confocal microscopy. Diffusion of TR-transferrin into the extracellular space and uptake by cells up to 400 microm from the implantation site was observed in brain slices taken 1 h postinsertion. The reactive tissue volume, as indicated by the presence of phosphorylated mitogen-activated protein kinases (MAPKs), was characterized using immunohistochemistry and confocal microscopy. The reactive tissue volume extended 600, 800, and 400 microm radially from the implantation site at 1 h, 24 h, and 6 weeks following insertion, respectively. These results indicate that diffusion-mediated delivery can be part of an effective intervention strategy for the treatment of reactive tissue responses around chronically implanted intracortical probes.


Assuntos
Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Eletrodos Implantados/efeitos adversos , Reação a Corpo Estranho/patologia , Reação a Corpo Estranho/prevenção & controle , Bombas de Infusão Implantáveis , Microfluídica/instrumentação , Animais , Desenho de Equipamento , Falha de Equipamento , Estudos de Viabilidade , Microeletrodos/efeitos adversos , Microfluídica/métodos , Ratos , Transferrina/administração & dosagem
19.
IEEE Trans Biomed Eng ; 51(9): 1640-8, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15376512

RESUMO

Neuronal cell networks have been reconstructed on planar microelectrode arrays (MEAs) from dissociated hippocampal pyramidal neurons. Microcontact printing (microCP) and a photoresist-liftoff method were used to selectively localize poly-L-lysine (PLL) on the surface of MEAs. Haptotaxis led to the organization of the neurons into networks localized adjacent to microelectrodes. Various grids of PLL with 2-25-microm-wide lines spaced by 50-200 microm with 15-25-microm nodes at intersection points were used to guide cell body attachment and neurite outgrowth. Bursting activity with spike amplitude attenuation was observed, and multichannel recordings detected instances of coincident firing activity. Finally, we present here an extracellular recording from a approximately 2 microm bundle of guided neurites.


Assuntos
Potenciais de Ação/fisiologia , Técnicas de Cultura de Células/instrumentação , Eletrofisiologia/instrumentação , Microeletrodos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Animais , Materiais Biocompatíveis/química , Técnicas de Cultura de Células/métodos , Células Cultivadas , Eletrofisiologia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Espaço Extracelular/fisiologia , Hipocampo/citologia , Hipocampo/embriologia , Hipocampo/fisiologia , Rede Nervosa/citologia , Rede Nervosa/embriologia , Neurônios/citologia , Ratos , Ratos Sprague-Dawley
20.
IEEE Trans Inf Technol Biomed ; 6(2): 171-87, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12075671

RESUMO

Algorithms are presented for fully automatic three-dimensional (3-D) tracing of neurons that are imaged by fluorescence confocal microscopy. Unlike previous voxel-based skeletonization methods, the present approach works by recursively following the neuronal topology, using a set of 4 x N2 directional kernels (e.g., N = 32), guided by a generalized 3-D cylinder model. This method extends our prior work on exploratory tracing of retinal vasculature to 3-D space. Since the centerlines are of primary interest, the 3-D extension can be accomplished by four rather than six sets of kernels. Additional modifications, such as dynamic adaptation of the correlation kernels, and adaptive step size estimation, were introduced for achieving robustness to photon noise, varying contrast, and apparent discontinuity and/or hollowness of structures. The end product is a labeling of all somas present, graph-theoretic representations of all dendritic/axonal structures, and image statistics such as soma volume and centroid, soma interconnectivity, the longest branch, and lengths of all graph branches originating from a soma. This method is able to work directly with unprocessed confocal images, without expensive deconvolution or other preprocessing. It is much faster that skeletonization, typically consuming less than a minute to trace a 70-MB image on a 500-MHz computer. These properties make it attractive for large-scale automated tissue studies that require rapid on-line image analysis, such as high-throughput neurobiology/angiogenesis assays, and initiatives such as the Human Brain Project.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Modelos Neurológicos , Neurônios/ultraestrutura , Animais , Estudos de Viabilidade , Neurônios/citologia , Ratos , Ratos Wistar , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa